RSG RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany Tel. +49 69 984047-0 Fax +49 69 984047-77 [email protected] www.rsg-electronic.de ■ ■ ELECTRONIC COMPONENTS ■ ■ ■ ■ Änderungen vorbehalten / subject to change without notice QP-100 100W Quad Output with PFC Function series Features : Universal AC input / Full range Built-in active PFC function, PF>0.95 Protections:Short circuit/Over load/Over voltage Free air cooling convection CH4: Polarity is selectable Fixed switching frequency at 100KHz 3 years warranty .. SPECIFICATION MODEL OUTPUT QP-100-3A QP-100-3C CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 DC VOLTAGE 5V 3.3V 12V -5V 5V 3.3V 12V -12V 5V 3.3V 15V -15V RATED CURRENT 8A 8A 2.5A 0.6A 8A 8A 2.2A 0.6A 8A 8A 1.7A 0.6A CURRENT RANGE 2 ~ 10A 0 ~ 10A 0.3 ~ 3A 0 ~ 1A 2 ~ 10A 0 ~ 10A 0.3 ~ 3A 0 ~ 1A 2 ~ 10A 0 ~ 10A 0.3 ~ 2A 0 ~ 1A RATED POWER (max.) 99.4W 100W 100.9W RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p CH1: 4.75 ~ 5.5V VOLTAGE ADJ. RANGE CH2: 3.14 ~ 3.63V CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V VOLTAGE TOLERANCE Note.3 3.0% 3.0% 6.0% 5.0% 3.0% 3.0% 6.0% 5.0% 3.0% 3.0% +8,-6% LINE REGULATION 1.0% 1.0% 2.0% 1.0% 1.0% 1.0% 2.0% 1.0% 1.0% 1.0% 2.0% 1.0% LOAD REGULATION 2.0% 2.0% 6.0% 2.0% 2.0% 2.0% 6.0% 2.0% 2.0% 2.0% 6.0% 2.0% SETUP, RISE TIME 800ms, 50ms/230VAC HOLD TIME (Typ.) 24ms/230VAC VOLTAGE RANGE INPUT QP-100-3B OUTPUT NUMBER 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.95/230VAC EFFICIENCY (Typ.) 74% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.5A/115VAC COLD START 800ms, 50ms/115VAC at full load 24ms/115VAC at full load Note.5 90 ~ 264VAC FREQUENCY RANGE 127 ~ 370VDC PF>0.98/115VAC at full load 74% <3.5mA / 240VAC OVER LOAD 105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed OVER TEMPERATURE(OPTION) WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE 75% 0.75A/230VAC 40A/230V LEAKAGE CURRENT PROTECTION OVER VOLTAGE 5.0% CH1:5.75 ~ 6.75V CH2:3.8 ~ 4.4V Protection type : Shut down o/p voltage, re-power on to recover 95 5 (TSW1) Protection type : Shut down o/p voltage, recovers automatically after temperature goes down -10 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0~50 ) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC SAFETY & ISOLATION RESISTANCE EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B EMC (Note 4) OTHERS HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A MTBF 139.9K hrs min. MIL-HDBK-217F (25 199*99*50mm (L*W*H) 0.87Kg; 20pcs/18.4Kg/1.28CUFT DIMENSION PACKING NOTE ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. File Name:QP-100-SPEC 2006-08-22 QP-100 100W Quad Output with PFC Function series Features : Universal AC input / Full range Built-in active PFC function, PF>0.95 Protections:Short circuit/Over load/Over voltage Free air cooling convection CH4: Polarity is selectable Fixed switching frequency at 100KHz 3 years warranty .. SPECIFICATION MODEL OUTPUT QP-100-3D QP-100F CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 DC VOLTAGE 5V 3.3V 24V -12V 5V 12V 24V -12V 5V 15V 24V -15V RATED CURRENT 8A 8A 1.3A 0.6A 8A 2.4A 1A 0.6A 8A 2A 1A 0.6A CURRENT RANGE 2 ~ 10A 0 ~ 10A 0.3 ~ 2A 0 ~ 1A 2 ~ 10A 0 ~ 3A 0.3 ~ 2A 0 ~ 1A 2 ~ 10A 0 ~ 3A 0.3 ~ 2A 0 ~ 1A RATED POWER (max.) 104.8W 100W 103W RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 150mVp-p 150mVp-p 120mVp-p 150mVp-p 200mVp-p 150mVp-p 120mVp-p 180mVp-p 200mVp-p 150mVp-p CH1: 4.75 ~ 5.5V VOLTAGE ADJ. RANGE CH2: 3.14 ~ 3.63V CH1: 4.75 ~ 5.5V CH2: 11.4 ~ 13.2V CH1: 4.75 ~ 5.5V CH2: 14.3 ~ 16.5V VOLTAGE TOLERANCE Note.3 3.0% 3.0% 6.0% 5.0% 3.0% 3.0% 6.0% 5.0% 3.0% 3.0% 6.0% LINE REGULATION 1.0% 1.0% 2.0% 1.0% 1.0% 1.0% 2.0% 1.0% 1.0% 1.0% 2.0% 1.0% LOAD REGULATION 2.0% 2.0% 6.0% 2.0% 2.0% 2.0% 6.0% 2.0% 2.0% 2.0% 6.0% 2.0% SETUP, RISE TIME 800ms, 50ms/230VAC HOLD TIME (Typ.) 24ms/230VAC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.95/230VAC EFFICIENCY (Typ.) 75% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.5A/115VAC COLD START 5.0% 800ms, 50ms/115VAC at full load 24ms/115VAC at full load Note.5 90 ~ 264VAC VOLTAGE RANGE INPUT QP-100D OUTPUT NUMBER 127 ~ 370VDC PF>0.98/115VAC at full load 78% 78% 0.75A/230VAC 40A/230V <3.5mA / 240VAC LEAKAGE CURRENT 105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1:5.75 ~ 6.75V CH2:3.8 ~ 4.4V CH1:5.75 ~ 6.75V CH2:13.8 ~ 16.2V CH1:5.75 ~ 6.75V Protection type : Shut down o/p voltage, re-power on to recover OVER LOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE(OPTION) WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE CH2:17.25 ~ 20.25V 95 5 (TSW1) Protection type : Shut down o/p voltage, recovers automatically after temperature goes down -10 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0~50 ) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC SAFETY & ISOLATION RESISTANCE EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B EMC (Note 4) OTHERS HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A MTBF 139.9K hrs min. MIL-HDBK-217F (25 199*99*50mm (L*W*H) 0.87Kg; 20pcs/18.4Kg/1.28CUFT DIMENSION PACKING NOTE ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. File Name:QP-100-SPEC 2006-08-22 RSG RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany Tel. +49 69 984047-0 Fax +49 69 984047-77 [email protected] www.rsg-electronic.de ■ ■ ELECTRONIC COMPONENTS ■ Änderungen vorbehalten / subject to change without notice ■ ■ ■ UQSPP- -1 0202 s5e r i e ss e r i e 100W Quad Output with PFC Function Mechanical Specification Case No. 916A Unit:mm 199 20 168 15 55 65 LED +V ADJ.2 +V ADJ.1 5-M3 L=6mm 10 38 4 3 2 1 99 79 51 2-M4 49.5 6.15 7.62 10 9 8 7 6 5 Terminal Pin No. Assignment : Assignment Assignment Pin No. Pin No. AC/L DC OUTPUT V3 1 5 AC/N DC OUTPUT V1 2 6,7 FG DC OUTPUT COM 3 8,9 DC OUTPUT V4 DC OUTPUT V2 4 10 25 12.5 25 50 25 117 4-M4 L=6mm Block Diagram fosc : 100KHz EMI FILTER & RECTIFIERS I/P POWER SWITCHING PFC CIRCUIT PWM & PFC CONTROL FG RECTIFIERS & FILTER RECTIFIERS & FILTER MA & CONTROL RECTIFIERS & FILTER V4 REGULATOR V3 RECTIFIERS & FILTER V2 +5V COM DETECTION CIRCUT O.V.P. Derating Curve Output Derating VS Input Voltage 100 100 90 80 80 70 70 LOAD (%) LOAD (%) 60 40 20 -10 -10 0 0 10 20 30 40 AMBIENT TEMPERATURE ( 50 60 50 40 60 (HORIZONTAL) 90 110 115 135 155 230 264 INPUT VOLTAGE (VAC) 60Hz ) File Name:QP-100-SPEC 2006-08-22 RSG RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany Tel. +49 69 984047-0 Fax +49 69 984047-77 [email protected] www.rsg-electronic.de ■ ■ ELECTRONIC COMPONENTS ■ Änderungen vorbehalten / subject to change without notice ■ ■ ■ RSG RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany Tel. +49 69 984047-0 Fax +49 69 984047-77 [email protected] www.rsg-electronic.de ■ ■ ELECTRONIC COMPONENTS ■ ■ ■ ■ Änderungen vorbehalten / subject to change without notice QP-100B,C 100W Quad Output with PFC Function series Features : Universal AC input / Full range Built-in active PFC function, PF>0.95 Protections:Short circuit/Over load/Over voltage Free air cooling convection Fixed switching frequency at 100KHz 3 years warranty .. SPECIFICATION MODEL OUTPUT QP-100B CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 DC VOLTAGE 5V 12V -12V -5V 5V 15V -15V -5V RATED CURRENT 10A 3A 1A 0.6A 10A 2.2A 1A 0.6A CURRENT RANGE 2 ~ 10A 0.3 ~ 4A 0.15 ~ 1A 0 ~ 1A 2 ~ 10A 0.3 ~ 3A 0.15 ~ 1A 0 ~ 1A RATED POWER (max.) 101W 150mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 101W RIPPLE & NOISE (max.) Note.2 100mVp-p CH1:4.75 ~ 5.5V VOLTAGE ADJ. RANGE CH1:4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 3.0% 6.0% +10,-6% 5.0% 3.0% +6,-10% 8.0% LINE REGULATION 1.0% 2.0% 2.0% 1.0% 1.0% 2.0% 2.0% 1.0% LOAD REGULATION 2.0% 6.0% 6.0% 2.0% 2.0% 2.0% 6.0% 2.0% 24ms at full load HOLD TIME (Typ.) VOLTAGE RANGE Note.5 90 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.95/230VAC EFFICIENCY (Typ.) 76% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.5A/115VAC 0.75A/230VAC COLD START 40A PF>0.98/115VAC at full load 77% LEAKAGE CURRENT <3.5mA / 240VAC OVER LOAD 105 ~ 135% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed PROTECTION OVER VOLTAGE OVER TEMPERATURE(OPTION) WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE 5.0% 1000ms, 50ms at full load SETUP, RISE TIME INPUT QP-100C OUTPUT NUMBER CH1:5.75 ~ 6.75V Protection type : Shut down o/p voltage, re-power on to recover 95 5 (TSW1) Protection type : Shut down o/p voltage, recovers automatically after temperature goes down -10 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0~50 ) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC SAFETY & ISOLATION RESISTANCE EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B EMC (Note 4) Compliance to EN61000-3-2,-3 HARMONIC CURRENT OTHERS EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A MTBF 139.9K hrs min. DIMENSION 199*99*50mm (L*W*H) 1.1Kg; 20pcs/22Kg/1.28CUFT PACKING NOTE MIL-HDBK-217F (25 ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. File Name:QP-100B,C-SPEC 2006-08-22 QP-100B,C 100W Quad Output with PFC Function Mechanical Specification Case No. 916A series Unit:mm 199 20 168 15 55 65 LED 51 99 79 5-M3 L=6mm 10 38 4 3 2 1 2-M4 49.5 6.15 7.62 10 +V ADJ.1 9 8 7 6 5 Terminal Pin No. Assignment : Assignment Assignment Pin No. Pin No. AC/L DC OUTPUT V3 1 5 AC/N DC OUTPUT V1 2 6,7 FG DC OUTPUT COM 3 8,9 DC OUTPUT V4 DC OUTPUT V2 4 10 25 12.5 25 50 25 117 4-M4 L=6mm Block Diagram fosc : 100KHz EMI FILTER & RECTIFIERS I/P POWER SWITCHING PFC CIRCUIT PWM & PFC CONTROL FG RECTIFIERS & FILTER RECTIFIERS & FILTER MA & CONTROL RECTIFIERS & FILTER V4 REGULATOR V3 RECTIFIERS & FILTER V2 +5V COM DETECTION CIRCUT O.V.P. Derating Curve Output Derating VS Input Voltage 100 100 90 80 80 70 70 LOAD (%) LOAD (%) 60 40 20 -10 -10 0 0 10 20 30 40 AMBIENT TEMPERATURE ( 50 60 50 40 60 (HORIZONTAL) 90 110 115 135 155 230 264 INPUT VOLTAGE (VAC) 60Hz ) File Name:QP-100B,C-SPEC 2006-08-22 RSG RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany Tel. +49 69 984047-0 Fax +49 69 984047-77 [email protected] www.rsg-electronic.de ■ ■ ELECTRONIC COMPONENTS ■ Änderungen vorbehalten / subject to change without notice ■ ■ ■