SFP Bi-Directional Transceiver SPS-34-GB-EBX-CxC Features • Compliant with IEEE 802.3ah, 1000Base-BX10 • Simplex SC Connector • Digital Diagnostic SFF-8472 Compliant • SFP MSA SFF-8074i Compliant • 13dB Minimum Power Budget • 20 km Minimum Reach • Commercial temperature available • Single 3.3V Supply • 1310nm FP Laser • Telcordia GR-468 Compliant • Color coded bail latch tube: Blue • RoHS compliant General Operation Parameter Symbol Min. Typ. Max. Supply Voltage Vcc 3.135 3.3 3.465 V Total Current ICC - - 300 mA Power Supply Noise Rejection Unit 100 - - mVp-p Operating Temperature (-CxC) Topr -5 - 70 ºC Storage Temperature Tstg -40 - 85 ºC Data Rate DR - 1250 - Mbps Transmitter Specifications (Optical) Parameter Symbol Min Typical Max Unit Optical Power Pop -7 -4 0 dBm Optical Crosstalk XT - -45 -40 dB Average Launch Power (Tx:Off) Poff - - -45 dBm Extinction Ratio ER 6 - - dB Optical Rise Time (20% to 80% values) tr - - Optical Fall Time (20% to 80% values) tf - - 260 ps Mean Wavelength λ 1260 1310 1360 nm Spectral Width (RMS) σ - - 3 nm Eye Mask IEEE 802.3ah 260 ps Relative Intensity Noise RIN - - -120 dB/Hz Transmitter Reflectance - - - -12 dB Reflection Tolerance rp - - 12 dB LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 1 LUMNDS1939-Aug2608 Rev A.0 SFP Bi-Directional Transceiver SPS-34-GB-EBX-CxC Transmitter Specifications (Electrical) Parameter Symbol Min Typical Rin 80 100 120 Ω Vin, p-p 250 - 1200 mV Vfault 2 - Vcc V - Vee + 0.5 V TxDisable_Disable Vnormal Vd Vee 2 - Vcc V TxDisable_Enable Ven Vee - Vee + 0.8 V Parameter Symbol Min Typical Max Unit Receiver Power Lowa - -22 -20 dBm Receiver Power Higha Rsens,low Rsens,high -3 - - dBm Damage Threshold for Receiver dBm Input Differential Impedence PECL Single-Ended Data Input Swing TxFault_Fault TxFault_Normal Max Unit Receiver Specifications (Optical) Pin, damage 0 - - Wavelength λ 1480 - 1580 nm LOS Assert - -45 - - dBm LOS De-Assert - - - -20 dBm LOS Hysteresis - 0.5 - - dB Receiver Reflectance a) Measured at 10-12 BER, PRBS 27-1, 6dB ER - - - -12 dB Parameter Symbol Min Typical Max Unit PECL Single-Ended Data Output Swing Vout,p-p 185 - 800 mV Data Output Rise Time tr - - 260 ps Data Output Fall Time tf - - 260 ps Receiver Specifications (Electrical) Timing and Electrical Parameter Symbol Min Typical Max Unit Tx Disable Negate Time t_on - - 1 ms Tx Disable Assert Time t_off - - 10 µs t_init - - 300 ms Tx Fault Assert Time Time to Initialize, Including Reset of Tx Fault t_fault - - 100 µs Tx Disable to Reset t_reset 10 - - µs t_loss_on - - 100 µs t_loss_off f_serial_clock Rx_LOSH 2 - 100 100 - µs KHz V LOS Assert Time LOS De-Assert Time Serial ID Clock Rate RX_LOS Voltage (High) RX_LOS Voltage (Low) RX_LOSL - - 0.8 V LOS Output Voltage-Fault VLOS fault 2 - Vcc V VLOS normal Vee - Vee + 0.5 V MOD_DEF (0:2)-High Vh 2 - V MOD_DEF (0:2)-Low VI Vee - Vcc Vee + 0.5 LOS Output Voltage-Normal LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 2 V LUMNDS1939-Aug2608 Rev A.0 SFP Bi-Directional Transceiver SPS-34-GB-EBX-CxC Diagnostics Parameter Range Temperature(-CDC) -5 to 70 Accuracy Unit Calibration Bit Value ±3 Voltage 0 to Vcc 0.1 Bias Current 0 to 120 5 ºC Formula External 1/256 C Tc(C) = Tslope*Tad(16 bit signed twos complement value) + Toffset V External 100µV mA External - I(mA) = Islope * Iad(16 bit unsigned integer)+Ioffset V(Volts) = Vslope*Vad (16 bit unsigned integer) + Voffset Tx Power -7 to 0 ±3 dBm External - Tx_PWR(µW) = Tx_PWRslope*Tx_PWRad(16 bit unsigned integer)+Tx_PWRoffset Rx Power -20 to -3 ±3 dBm External - Rx_PWR(µW) = A0+A1*x+A2*x^2+A3*x^3+A4*x^4 Pinout Definitions Pin Function Notes 1 VeeT TX GND 2 TX_FAULT Open Collector 3 TX_DISABLE Internally Pulled High 4 MOD_DEF2 Serial Data Input 5 MOD_DEF1 Serial Clock Input 6 MOD_DEF0 Internally Grounded 7 NC Not Connected 8 LOS Open Collector 9 VeeR RX Ground 10 VeeR RX Ground 11 VeeR RX Ground 12 RXD- RX Data Negative 13 RXD+ RX Data Positive 14 VeeR RX GND 15 VCCR RX Power 16 VCCT TX Power 17 VeeT TX GND 18 TXD+ TX Data Positive 19 TXD- TX Data Negative 20 VeeT TX GND LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 3 LUMNDS1939-Aug2608 Rev A.0 SFP Bi-Directional Transceiver SPS-34-GB-EBX-CxC EEPROM Serial ID Name of Field Vendor Name Vendor OUI Vendor P/N LUMINENTOIC.COM Discription of Field SFP Vendor name (ASCII) IEEE vendor OUI code for Luminent Inc. Part number in ASCII, e.g. SPS34GBEBXCDC Address Hex 20 4C L 21 55 U 22 4D M 23 49 I 24 4E N 25 45 E 26 4E N 27 54 T 28 4F O 29 49 I 30 43 C 37 00 38 06 39 B5 40 53 S 41 50 P 42 53 S 43 33 3 44 34 4 45 47 G 46 42 B 47 45 E 48 42 B 49 58 X 50 43 C 51 44 D 52 43 C 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 4 ASCII LUMNDS1939-Aug2608 Rev A.0 SFP Bi-Directional Transceiver SPS-34-GB-EBX-CxC Suggested Transceiver Interface Mechanicals Units in mm(inches) LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 5 LUMNDS1939-Aug2608 Rev A.0 SFP Bi-Directional Transceiver SPS-34-GB-EBX-CxC Suggested Transceiver Interface 1�H Vcc 10�F 1�H 0.1�F VCCT .01�F Protocol IC R1 LuminentOIC SFP 10K� TX_DISABLE TX_DISABLE TX_FAULT TX_FAULT TD + SerDes Laser Driver .01�F 100� TD VEET .01�F VCCR 10�F 0.1�F RD + Receiver Amplifier .01�F 100� RD - RX_LOS RX_LOS Vcc R VEER 1 R1 R1 .01�F EEPROM R1 MOD_DEF 2 MOD_DEF 1 MOD_DEF 0 R1=4.7K to 10K� LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 6 LUMNDS1939-Aug2608 Rev A.0 SFP Bi-Directional Transceiver SPS-34-GB-EBX-CxC Ordering Information Available Options: SPS-34-GB-EBX-CNC SPS-34-GB-EBX-CDC Part numbering Definition: SPS - 34 - GB - EBX - Temperature Diagnostic Revision • SPS = SC connector • Wavelength 34 = Tx 1310nm/Rx 1490nm • Data Rate GB = Gigabit Ethernet • Standard EBX = 20 km reach • Operating Temperature C = Commercial temperature (-5 to 70ºC) • D = Digital Diagnostic N = No Digital Diagnostic • Revision C = RoHS compliant Warnings: Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow guidelines according to proper ESD procedures. Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation. Legal Notes: IMPORTANT NOTICE! All information contained in this document is subject to change without notice, at Luminent’s sole and absolute discretion. Luminent warrants performance of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are given to describe components only, and Luminent expressly disclaims any and all warranties for said products, including express, implied, and statutory warranties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of Sale for further warranty information. Luminent assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and Luminent makes no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. Luminent customers using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify Luminent for any damages resulting from such use or sale. THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that Luminent is not liable for any actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact Luminent to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current. © Luminent, Inc. 2003 All rights reserved LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 7 LUMNDS1939-Aug2608 Rev A.0