SFP Bi-Directional Transceiver SPS-43-GB-BX Features • Compliant with IEEE 802.3ah, 1000BaseBX • Simplex SC Connector • Digital Diagnostic SFF-8472 Compliant • 11dB Minimum Power Budget • 10km Minimum Reach • Commercial Temperature Operation • Single 3.3V Supply • 1490nm DFB Laser • Telcordia GR-468 Compliant • Color Coded Bail Latch: Purple • RoHS-5/6 compliant product (lead exemption) (-xxA) • RoHS compliant product (-xxC) General Operation Parameter Symbol Min. Typ. Max. Supply Voltage Vcc 3.135 3.3 3.465 V Total Current ICC - - 300 mA Power Supply Noise Rejection Unit 100 - - mVp-p Operating Case Temperature (-Cxx) Topr -5 - 70 ºC Operating Case Temperature (-Txx) Topr -40 - 85 ºC Storage Temperature Tstg -40 - 85 ºC Data Rate DR - 1250 - Mbps Transmitter Specifications (Optical) Parameter Symbol Min Typical Max Unit Optical Power Pop -9 -6 -3 dBm Optical Crosstalk XT - -45 -40 dB Average Launch Power (Tx:Off) Poff - - -45 dBm Extinction Ratio ER 6 - - dB Eye Mask IEEE 802.3ah Compliant Optical Rise time (20% to 80% values) tr - - 260 ps Optical Fall time (20% to 80% values) tf - - 260 ps Mean Wavelength λ 1480 1490 1500 nm Maximum RMS Width σ - - 0.88 nm Relative Intensity Noise RIN - - -120 dB/Hz - - - -12 dB ORLT - - 12 dB Transmitter Reflectance Optical Return Loss Tolerance LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 1 LUMNDS107-Dec1106 Rev A.4 SFP Bi-Directional Transceiver SPS-43-GB-BX Transmitter Specifications (Electrical) Parameter Symbol Input Differential Impedence PECL Single Ended data input swing TxFault_Fault Min Typical Max Unit Rin 80 100 120 Ω Vin, p-p 250 - 1200 mV Vfault 2 - Vcc V Vee - Vee + 0.5 V TxDisable_Disable Vnormal Vd 2 - Vcc V TxDisable_Enable Ven Vee - Vee + 0.8 V Parameter Symbol Min Typical Max Unit Receiver Power Lowa Rsens,low - -22 -20 dBm Receiver Power High Rsens,high -3 - - dBm Damage Threshold for Receiver Pin, damage 0 - - dBm Wavelength λ 1260 - 1360 nm LOS Assert - -45 - - dBm LOS De-Assert - - - -20 dBm LOS Hysteresis - 0.5 - - dB Receiver Reflectance - - - -12 dB Parameter Symbol Min Typical Max Unit PECL Single-Ended Data Output Swing Vout,p-p 185 - 800 mV Data Output Rise Time tr - - 500 ps Data Output Fall Time tf - - 500 ps TxFault_Normal Receiver Specifications (Optical) a a) Measured at 10-12 BER, PRBS 27-1, 6dB ER Receiver Specifications (Electrical) LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 2 LUMNDS107-Dec1106 Rev A.4 SFP Bi-Directional Transceiver SPS-43-GB-BX Timing and Electrical Parameter Symbol Min Typical Max Unit t_on - - 1 ms Tx Disable Assert Time t_off - - 10 µs Time to Initialize, Including Reset of Tx Fault t_init - - 300 ms Tx Disable Negate Time Tx Fault Assert Time t_fault - - 100 µs Tx Disable to Reset t_reset 10 - - µs t_loss_on - - 100 µs t_loss_off f_serial_clock Rx_LOSH 2 - 100 100 - µs KHz V LOS Assert Time LOS De-Assert Time Serial ID Clock Rate RX_LOS Voltage (high) RX_LOS Voltage (low) RX_LOSL - - 0.8 V LOS Output Voltage-Fault VLOS fault 2 - Vcc V VLOS normal Vee - Vee + 0.5 V Vcc Vee + 0.5 V LOS Output Voltage-Normal MOD_DEF (0:2)-High Vh 2 - MOD_DEF (0:2)-Low VI Vee - Calibration Bit Value V Diagnostics Parameter Range Accuracy Unit Temperature (-CDx) -5 to 70 ±3 ºC Internal 1/256 C Tc(C) = Tad(16 bit signed twos complement)/256 Formula Temperature (-TDx) -40 to 85 ±3 ºC Internal 1/256 C Tc(C) = Tad(16 bit signed twos complement)/256 Voltage 0 to Vcc 0.1 V Internal 100µV V(Volts) = Vad(16 bit unsigned integer)*0.1 Bias Current 0 to 120 5 mA External - I(mA) = Islope * Iad(16 bit unsigned integer)+Ioffset Tx Power -9 to -3 ±3dB mW External - Tx_PWR(µW) = Tx_PWRslope*Tx_PWRad(16 bit unsigned integer)+Tx_PWRoffset Rx Power -20 to -3 ±3dB mW External - Rx_PWR(µW) = A0+A1*x+A2*x^2+A3*x^3+A4*x^4 LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 3 LUMNDS107-Dec1106 Rev A.4 SFP Bi-Directional Transceiver SPS-43-GB-BX EEPROM Serial ID Name of Field Vendor Name Vendor OUI Vendor P/N LUMINENTOIC.COM Discription of Field SFP Vendor name (ASCII) IEEE vendor OUI code for Luminent Inc. Part number in ASCII, e.g. SPS-43-GB-BX-CDA Address Hex 20 4C L 21 55 U 22 4D M 23 49 I 24 4E N 25 45 E 26 4E N 27 54 T 28 4F O 29 49 I 30 43 C 37 00 38 06 39 B5 40 53 S 41 50 P 42 53 S 43 34 4 44 33 3 45 47 G 46 42 B 47 42 48 58 B X 49 43 C 50 44 D 51 41 A 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 4 ASCII LUMNDS107-Dec1106 Rev A.4 SFP Bi-Directional Transceiver SPS-43-GB-BX Pinout Definitions Pin Function Notes 1 VeeT TX GND 2 TX_FAULT Open Collector 3 TX_DISABLE Internally Pulled High 4 MOD_DEF2 Serial Data Input 5 MOD_DEF1 Serial Clock Input 6 MOD_DEF0 Internally Grounded 7 NC Not Connected 8 LOS Open Collector 9 VeeR RX Ground 10 VeeR RX Ground 11 VeeR RX Ground 12 RXD- RX Data Negative 13 RXD+ RX Data Positive 14 VeeR RX GND 15 VCCR RX Power 16 VCCT TX Power 17 VeeT TX GND 18 TXD+ TX Data Positive 19 TXD- TX Data Negative 20 VeeT TX GND LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 5 LUMNDS107-Dec1106 Rev A.4 SFP Bi-Directional Transceiver SPS-43-GB-BX Mechanicals Units in mm(inches) LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 6 LUMNDS107-Dec1106 Rev A.4 SFP Bi-Directional Transceiver SPS-43-GB-BX Suggested Transceiver Interface Diagnostics 1�H Vcc 10�F 1�H 0.1�F VCCT .01�F Protocol IC LuminentOIC SFP 10K� R1 TX_DISABLE TX_DISABLE TX_FAULT TX_FAULT TD + SerDes Laser Driver .01�F 100� TD VEET .01�F VCCR 10�F 0.1�F RD + Receiver Amplifier .01�F 100� RD - RX_LOS RX_LOS Vcc R VEER 1 R1 R1 .01�F EEPROM R1 MOD_DEF 2 MOD_DEF 1 MOD_DEF 0 R1=4.7K to 10K� LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 7 LUMNDS107-Dec1106 Rev A.4 SFP Bi-Directional Transceiver SPS-43-GB-BX Ordering Information Available Options: SPS-43-GB-BX-CNA SPS-43-GB-BX-CDA SPS-43-GB-BX-TNA SPS-43-GB-BX-TDA SPS-43-GB-BX-CNC SPS-43-GB-BX-CDC SPS-43-GB-BX-TNC SPS-43-GB-BX-TDC Part Numbering Definition: SPS - 43 - GB - BX - Temperature Diagnostic Revision • SPS = SC connector • Wavelength 43 = Tx 1490nm/Rx 1310nm • Data Rate GB = Gigabit Ethernet • Standard BX = 1000BASE-BX • Operatating Temperature C= Commercial temperature (-5 to 70ºC) T= Industrial temperature (-40 to 85ºC) • Diagnostic D = Digital Diagnostic N = No Diagnostic • Ordering Information A=RoHS 5/6-compliant product (lead exemption) C=RoHS 6/6-compliant (no exemption) LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 8 LUMNDS107-Dec1106 Rev A.4 SFP Bi-Directional Transceiver SPS-43-GB-BX Warnings: Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow guidelines according to proper ESD procedures. Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation. Legal Notes: IMPORTANT NOTICE! All information contained in this document is subject to change without notice, at LuminentOIC’s sole and absolute discretion. LuminentOIC warrants performance of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warranties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of Sale for further warranty information. LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from such use or sale. THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that LuminentOIC is not liable for any actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current. © LuminentOIC, Inc. 2003 All rights reserved LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 9 LUMNDS107-Dec1106 Rev A.4