AFE2000 SERIES Single output • Approved to EN61000, IEC-1000, UL1950, CSA 22.2 No. 950-95 • Operating ambient temperature of 0°C to +50°C • Complies with ETS300 132-1 and EN61000-3-2 • Hot-swap capability • 11.5 x 6.75 x 4.9 inch size • N+1 redundancy capability • Extensive features available • Compatible with AFS standard shelves for configuring rack-mounted power systems The AFE2000 power module is a rack mountable single phase AC to DC power supply, designed to be a cost-competitive front-end power supply for distributed power systems. It is particularly suitable for use in data processing, datacom and telecom applications. The outputs are floating so the end user can ground the plus, minus or neither depending on the end use application. The AFE2000 power modules are designed for hot-swap operation and can be mounted into AFS4000/6000 power shelves for redundant-mode operation. [ 2 YEAR WARRANTY ] SPECIFICATION All specifications are typical at nominal input, full load at 25°C unless otherwise stated EMC CHARACTERISTICS OUTPUT SPECIFICATIONS Output voltage Main: 48/54.5/56.2VDC Auxiliary: 12VDC ±1.0% ±1.0% Conducted emissions FCC-CFR, part 15, subpart B Class B CISPR 22 Class B Output power Main Auxiliary 2000W 12W Radiated emissions Regulation Line, load, IT, ageing ±3.0% Turn-on Output rise time 100 to 400ms Turn-on (AC applied) 4s max. Turn-on (inhibit removed) 1.5s max. FCC-CFR, part 15, subpart B (Note 7) CISPR 22 (Note 7) IEC1000-6 Level 2 IEC1000-3 Level 3 IEC1000-2 Level 3 per EN61000-3-2 Compliant Ripple and noise (<50MHz) Transmission noise 480mV pk-pk 100 to 3kHz 35dBrnC Overvoltage protection 60VDC max. Undervoltage protection >44.5VDC <42VDC for >5s Short circuit protection Current sharing <30s >30s Automatic recovery Latch-off ±10% Hold-up time (See Note 1) Efficiency Isolation voltage 200/240VAC nom. Input/output Input/chassis Output/chassis Switching frequency Approvals and standards Input frequency range 50/60Hz nom. Input surge current 25°C cold start Safety ground leakage current 254VAC @ 60Hz Input current 220VAC, 2000W 47Hz to 63Hz 22A 1.5mA max. 0.5mA typ. 10.5A rms 0.99 min. MTBF 3000VAC 1500VAC 100VAC 200kHz EN60950, IEC950, UL1950 CSA C22.2 No. 950 Electrolytic zinc coated CRS, ASTM A591, light beige paint Weight 170 to 264VAC 500ms 20ms 86% 1.0V max. distribution line loss Input voltage range 5.0kg (11Ibs) MIL-HDBK-217E Demonstrated 150,000 hours 300,000 hours ENVIRONMENTAL SPECIFICATIONS Thermal performance Operating ambient Non-operating Cooling 0°C to +50°C -40°C to +100°C Forced air Relative humidity Operating 5% to 95% RH Altitude Operating 13,000 feet max. Vibration 5Hz to 500Hz Shock PAGE 1 150 to 170VAC 0 to 150VAC Case material INPUT SPECIFICATIONS Power factor GENERAL SPECIFICATIONS Delivers full power Latch-off Active current share (50% to 100% loading) Remote sense Immunity - conducted Immunity - radiated Immunity - ESD Line harmonics 0.75G rms peak 15G, 1/2 Sine, 11ms DISTRIBUTED POWER FRONT END AC/DC POWER SUPPLIES | 2000W AC/DC 2000 Watt AC/DC PFC front-end for distributed power architectures OUTPUT OUTPUT CURRENT TOTAL REMOTE PARALLEL REGULATION ENABLE/INHIBIT INTERFACES RIPPLE MODEL NUMBER VOLTAGE MIN MAX 48VDC 0A 41.7A 480mV ±3.0% Inhibit All AFE2000-26S48NA 54.5VDC 0A 36.7A 545mV ±3.0% Inhibit All AFE2000-26S54NA 56.2VDC 0A 35.6A 562mV ±3.0% Inhibit All AFE2000-26S56NA Parallel interface specifications. All signals are referenced to ISO_GND unless otherwise indicated. Isolated signal ground (ISO_GND) May be connected to any voltage in the range from +Vout+5VDC to -Vout5VDC. Overtemperature (OTW) Output bi-level signal. Bi-level signals are open-collector (drain) with a 5mA sink capability and maximum voltage stand-off of 60VDC. Logic 0 : Signal precedes OT shutdown by 5ms. Logic 1 : Normal operation. Remote Inhibit (INHIBIT) Input bi-level signals. Bi-level input signals shall be no greater than 5VDC. Logic 0 : Normal operation. Logic 1 : Output inhibit. Voltage margin down (DOWN) Input bi-level signals. Bi-level input signals shall be no greater than 5VDC. Logic 0 : Nominal output voltage. Logic 1 : 44.5 to 45.5VDC output. Power good signal (PWR_GOOD) Output bi-level signal. Bi-level signals are open-collector (drain) with a 5mA sink capability and maximum voltage stand-off of 60VDC. Logic 0 : Output undervoltage. Logic 1 : Output voltage normal. Fault fail signal (F/F ±) Differential relay contact, isolated from all outputs and returns within the power module. Relay closed : Power supply failure Relay open : Normal operation. Power fail warning signal (PFW) Output bi-level signal. Bi-level signals are open-collector (drain) with a 5mA sink capability and maximum voltage stand-off of 60VDC. Logic 0 : Signal precedes loss of output power by 5ms. Logic 1 : Normal operation. Module Missing Pin (MM) Provision for detection of unseated or removed module. MM pins are common internal to the power supply. Internal pull-up resistor to +5VDC logic bias, referenced to RS-. Auxiliary Output (AUX ±) 12VDC auxiliary output. Isolated from both the main output and the isolated signal ground. May be utilized for external housekeeping supply and connected to either main output or isolated signal ground. Reset (RESET) Input bi-level signal. Bi-level input signal shall be no greater than 5VDC. Logic 0 : Resets fault indicators without unit shut-down. Logic 1 : Normal operation. AC Good (AC OK) Output bi-level signal. Bi-level output signal is open-collector (drain) with a 5mA sink capability and maximum voltage stand-off of 60VDC. Logic 0 : AC input below normal operating range. Logic 1 : AC input within steady-state operating range (170 to 264VAC). Voltage monitoring (VMARG) Input analog signal referenced to RS-. Adjusts output up to 4VDC higher than the nominal set point. Features Live insertion and removal OR-ing diodes provided on output. Voltage monitoring jacks Located on front panel. LED’s (located on front panel) Power Good Power Fail AC Good - Green Red Green Protection Thermal protection - automatic shut-off for fan failure or internal overtemperature. Output Overload and Short Circuit - automatic shut-down after 30 seconds. Current regulated output down to less than 1VDC. Output Overvoltage - automatic shut-down for both main (60VDC max.) and auxiliary (15.6VDC max.) outputs. Output Undervoltage - automatic shut-down below 42VDC. Current Share Active current sharing for up to 9 AFE2000 power modules. Short Pin Short pin located in the output connector initiates shut-down of the power supply output when the power supply is removed from the host power shelf. Current Monitor (IMON) Current source which mirrors magnitude of the output current. Signal return is referenced to RS-. Current Limit (CL) Output bi-level signal. Bi-level output signal is open-collector (drain) with a 5mA sink capability and maximum voltage stand-off of 60VDC. Logic 0 : Output is in current mode control and is current limiting. Logic 1 : Normal operation. Remote Enable (ENABLE) Input bi-level signal. Bi-level input signal shall be no greater than 5VDC. Logic 0 : Output inhibited. Logic 1 : Normal operation. International Safety Standard Approvals EN60950/IEC950 File No. E9972397 UL1950 File No. E135734 Please consult our website for the following items: ✔ Application Note http://www.artesyn.com PAGE 2 2000W AC/DC | DISTRIBUTED POWER FRONT END AC/DC POWER SUPPLIES 2000 Watt AC/DC PFC front-end for distributed power architectures PIN CONNECTIONS PIN NO. FUNCTION PIN NO. FUNCTION PIN NO. FUNCTION PIN NO. FUNCTION A1 Short Pin B1 DOWN C1 RS+ D1 +Vout A2 AUX+ B2 VMARG C2 RS- D2 +Vout A3 AUX- B3 MM C3 MM D3 PWR RTN A4 RS- B4 I SHR C4 F/F- D4 PWR RTN A5 Not Used B5 RESET C5 F/F+ D5 CGND A6 Not Used B6 IMON C6 INHIBIT/ENABLE A7 AC OK B7 Power Good C7 CL B8 (3) C8 OTW A8 PFW ISO GND (2) Notes 1 2 3 4 5 6 PFW signal warning issued 5 msec prior to shutdown. Chassis or safety ground. Isolated signal ground. Output ground - referenced to RS-. Refer to Application Note 106 for installation of the AFE2000 power modules into the AFS4000 power shelf. Refer to Application Note 110 for description of outputs and signals available with AFE2000 power modules installed in Artesyn standard frontend power shelf. 7 8 Class A for power module, Class B when installed in AFS4000 shelf (subject to cable/system configuration). NOTICE: Some models do not support all options. Please contact your local Artesyn representative or use the on-line model number search tool at http://www.artesyn.com/powergroup/products.htm to find a suitable alternative. SHORT SIGNAL PIN A1 B1 C1 A8 B8 C8 D5 D4 D3 D2 D1 6.44 (163.58) AIR FLOW NORMAL 0.074 (1.879) 11.46 (291.08) AC INPUT POWER DYNAMICS 42R08-1122 MATE - POWER DYNAMICS 43R06-2114 0.25 (6.35) 1.30 (33.02) 6.75 (171.45) 5.725 (145.415) 0.800 (20.32) 4.23 (107.44) 4.83 (122.68) 0.050 (1.270) TAPERED GUIDE PIN HOLE 0.0875 (2.2225) 2.063 (52.400) AC GOOD PWR FAIL PWR GOOD V OUT 0.625 (15.875) REF 0.475 (12.065) TAPERED GUIDE PIN HOLE 0.462 (11.735) 0.375 (9.525) INSERTION/EJECTOR HANDLE WITH 6-32 CAPTIVE SCREW MAIN DC OUTPUT/SIGNALS ELCON 279-0468-00100 MATE - ELCON 278-0468-00200 (J2) DC connector (J2) DC mating connector Elcon 279-0468-00100 or equivalent. Elcon 278-0468-00200 or equivalent. (J1) AC connector (J1) AC mating connector Power Dynamics 42R08-1122 or equivalent. Power Dynamics 43R06-2114 or equivalent. PAGE 3 ds_afe2000_20050824.PDF Datasheet © Artesyn Technologies® 2005 The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.