DPF600 SERIES Dual output • • • • • • • The DPF600 is a 600W universal input AC/DC front end power supply in a fully enclosed hot pluggable case with built-in fan, front panel with handle, IEC input connector, on/off switch and DIN output signal connector. Providing dual 49V and 5V outputs with a full set of status signals, the DPF600 is designed as a slot-in front end for distributed power systems. The DPF600 provides 600W of output power and is fully compliant with EN61000-3-2. Standard features include current sharing and full protection against overvoltage, overload and short circuit. Remote or local system monitoring is possible via a full set of status signals that include fan fail, DC good, remote inhibit and current monitoring. The DPF600, with full international safety approval and the CE mark, meets conducted emissions EN55022 level B. The DPF600 is designed for use as a front end in medium power communication applications adopting distributed power architecture. The DPF600 can be used in conjunction with our complete range of 3 to 200W DC/DC converters to fully configure a distributed power system. Patent No. 5446366 [ 2 YEAR WARRANTY ] SPECIFICATION 600W front end EN61000-3-2 compliant Hot pluggable N+1 redundancy Full set of status signals EN55022, EN55011 conducted emissions level B UL, TÜV, CSA and BABT approvals All specifications are typical at nominal input, full load at 25°C unless otherwise stated EMC CHARACTERISTICS OUTPUT SPECIFICATIONS Voltage set point -49VDC ±245mVDC with 2A load applied Total regulation Main output Full load to no load ±5.0% Rise time At turn-on Transient response Main output 50% to 100% step at 1.0A/µs 5.0% max. dev., 1ms recovery to 1.0% Ripple and noise (0Hz to 30MHz) Main output Auxiliary output 750mV pk-pk, 100mV pk-pk Overvoltage protection Latching main output Latching 0.5s, max. -55V to -60V 5.7V to 6.5V Output power limit Short circuit protection 750W Non-latching Auto-recovery Current sharing ±10%, 3V droop from 15% to 100% Radiated emissions Conducted emissions Harmonic current emm. Electrical fast transients/bursts Surge susceptibility EN55022/11, FCC part 15 EN55022/11, FCC part 15 EN61000-3-2 EN61000-4-4 EN61000-4-5 Level 3 GENERAL SPECIFICATIONS Hold-up time 120VAC, 60Hz FL Efficiency 100Vin, load >66% rated 82% min. Isolation voltage Input/output Input/chassis 3000VAC 1500VAC Switching frequency Approvals and standards EN60950, UL1950, BABT CSA C22.2 No. 950 Weight 6.9kg (15Ibs) MTBF 500,000 hours demonstrated Input voltage range 85 to 264VAC ENVIRONMENTAL SPECIFICATIONS Input frequency range 47Hz to 63Hz Thermal performance 230VAC, cold start @ 25°C Input surge 300VAC Safety ground leakage current 120VAC, 60Hz 230VAC, 50Hz 0.2mA 0.4mA Input current 90VAC, 600W 220VAC 7.35A rms max. 2.84A rms max. Input fuse Non-replaceable Power factor 35A max. 20ms 15A 0.99 120Vin, >66% load Operating ambient 0°C to +50°C Non-operating -40°C to +85°C 50°C to 70°C ambient Derate to 50% Cooling Built-in fan Relative humidity Non-condensing Altitude Operating Non-operating Vibration 5Hz to 500Hz International Safety Standard Approvals TÜV VDE0805/EN60950/IEC950 UL1950 File No. E136005 CSA C22.2 No. 950 File No. LR41062C PAGE 1 Certificate No. 606090 20ms @ 600W 50kHz INPUT SPECIFICATIONS Input surge current Level A Level B Compliant Level 3 5% to 85% RH 10,000 feet max. 40,000 feet max. 2.4G rms peak DISTRIBUTED POWER FRONT END AC/DC POWER SUPPLIES | 600W AC/DC 600 Watt AC/DC PFC front-end for distributed power architectures OUTPUT CURRENT OUTPUT -49V TOTAL RIPPLE VOLTAGE MIN (3) MAX (4) 12A 750mV ±5.0% 0.2A 10A 50mV ±5.0% 0A MODEL NUMBER REGULATION DPF600-9617 +5V Notes 1 2 3 4 STATUS AND CONTROL SIGNALS Fan fail and power good are open collector signals. All signals are referenced to earth ground, as is the 5V output. The main output is floating. 49.5V at minimum current. Fan fail H (1,2) Asserted in event of a failure Power good L Asserted when the output voltage is within specification Inhibit L Inhibits the main output when this pin is open or low Current monitor Provides an analog voltage reflection of the main output current 1.25 (31.75) 11.94 (303.28) AIR FLOW 6.73 (170.94) 1.619 (REF.) (41.12) 2.18 ± .02 (55.37 ± 0.51) 2.18 (REF.) (55.37) 2.105 ± .015 (53.467 ± 0.381) 1.47 ± .02 (37.34 ± 0.51) 1.47 (REF.) (37.34) .22 (2PL) (5.59) .985 REF (25.019) PIN NUMBER Pin C6 Pin C8 Pin C4 Pin B6 Pins B1, C1 Pins A1-2 .806 ± .01 (20.47 ± 0.25) 3.340 (84.84) 1.015 ± .01 (25.78 ± 0.25) OUTPUT PIN CONNECTIONS FUNCTION PIN NUMBER Power Good H Pins A10-12 Inhibit L Pins B9-12 Current Monitor Pins C9-12 Fan Fail H Pins A-C, 13-16 -48V Fan Pin A9 -48V Fan Return Pin B8 ALL DIMENSIONS IN INCHES (mm) Mating connectors FUNCTION 5V Output 5V Output 5V Output Ground +5V Sense Ground Sense Signal 48-pin female DIN connector Main output ICON connectors (ELCON P/N: 259-28-00100) Input IEC http://www.artesyn.com PAGE 2 DS_DPF600_19980401.PDF Data Sheet © Artesyn Technologies® 2000 The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.