ARTESYN M4000-86-9

M3000 and M4000 SERIES
Single output
•
•
•
•
•
•
•
•
The M series is a range of single output, high current power supplies ideally suited to a
broad range of applications. Robust performance and field proven reliability are
hallmarks of this series. Field reliability in excess of 100,000 hours has been
documented. The M series will provide stable power for any large electronic system
including telecommunication, data processing and industrial. Typical applications
include broadcast systems, ATM systems and RISC processors and systems.
Semiconductor test equipment, semiconductor and wafer processing equipment and
functional board level testers are other possible applications. Industrial uses include
applications such as laser cutting, water purification, battery charging, machine control,
large scale data logging and optical inspection equipment. Current sharing, built-in
current monitoring, voltage margining and remote adjustment capability are standard
features. Other system interface features include AC and DC good, OVP, OCP, over
temperature protection and remote enable. Worldwide safety certifications are included.
[ 2 YEAR WARRANTY ]
SPECIFICATION
Load currents up to 800A
3 phase or single phase input
Shutdown on phase loss
3 phase power factor correction
Single wire current share to 5%
Ideal for N+1 applications
Current monitor output included
UL, CSA and TÜV safety approvals
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
EMC CHARACTERISTICS
OUTPUT SPECIFICATIONS
Voltage adjustability
Accessible at front panel
Remote sense
Open/reverse sense lead protection
Compensates for voltage drop
of up to 0.5V to the load
Regulation, line or load All outputs, NL to FL
at nominal line or all
line variations at FL
Overshoot/undershoot
Transient response
±0.2%; 10mV
≤5.0% max. dev.,
≤200µs recovery
to 1.0%
Main output
25% step load
change at 1A/µs
0Hz to 20MHz
Overvoltage protection
Reset by cycling AC
Overload protection
115% to 130%
of nominal
105% to 115% full load
Thermal protection
Auto recovery
Auto shutdown, AC reset
Current sharing
±5.0%
Current monitor (V1)
5VDC at full load
50% to 100% load
±0.5V
INPUT SPECIFICATIONS
3 phase
1 phase (optional)
Input frequency range
EN61000-4-5
Level 3
Efficiency
208VAC, 3 phase
Isolation voltage
Input/output
Input/chassis
Output/output
180 to 264VAC
180 to 264VAC
Meets IEEE std. 587.1980;
3KV ring wave
Input current
208VAC, 3 phase
208VAC, 1 phase
12A
27A
Power factor
3 phase
1 phase
0.94
0.65
Power up time
Full load
1.0s max.
25ms min.
83%
3000VAC
1500VAC
500VAC
Switching frequency
100kHz
Approvals and
standards
TÜV EN60950, UL1950,
CSA C22.2 No. 950
Weight
13kg (29Ibs)
Size
5 x 8 x 13.5 inches
127 x 203.2 x 342.9 mm
MTBF
>100,000 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating ambient
Non-operating
Cooling
50CFM
Relative humidity
Non-condensing
Altitude
Operating
Non-operating
Vibration
5Hz to 500Hz
47Hz to 63Hz
Input surge current
PAGE 1
Level A
Level A
Level 3
Level 3
Level 3
230VAC, 3KW load
100mV pk-pk or 1.0%
90% of rated load
EN55022/11, FCC part 15
EN55022/11, FCC part 15
EN61000-4-2
EN61000-4-3
EN61000-4-4
Hold-up time
0.02%/°C
Ripple and noise
Input voltage range
Radiated emissions
Conducted emissions
Electrostatic discharge
RF field susceptibility
Electrical fast
transients/bursts
Surge susceptibility
GENERAL SPECIFICATIONS
None at turn on/off
Temperature coefficient
Short circuit protection
±10%
0°C to +50°C
-15°C to +85°C
Internal DC
ball bearing fans
0% to 95% RH
6,000 feet max.
55,000 feet max.
2.4G rms peak
MEDIUM TO HIGH POWER AC/DC POWER SUPPLIES
|
3000-4000W AC/DC
3000 and 4000 Watt
AC/DC high current power supplies with PFC
MAX. OUTPUT
INPUT
POWER
VOLTAGE
(3)
OUTPUT
OUTPUT
VOLTAGE
CURRENT
MODEL
NUMBER
(3)
3000W
Single Phase
2V
600A
M3000-26-0
3000W
Single Phase
3.3V
600A
M3000-26-9
3000W
Single Phase
5V
600A
M3000-26-1
3000W
Single Phase
12V
250A
M3000-26-2
3000W
Single Phase
15V
200A
M3000-26-3
3000W
Single Phase
24V
125A
M3000-26-4
3000W
Single Phase
28V
107A
M3000-26-5
3000W
Single Phase
48V
63A
M3000-26-6
3000W
Three Phase
2V
600A
M3000-86-0
3000W
Three Phase
3.3V
600A
M3000-86-9
3000W
Three Phase
5V
600A
M3000-86-1
3000W
Three Phase
12V
250A
M3000-86-2
3000W
Three Phase
15V
200A
M3000-86-3
3000W
Three Phase
24V
125A
M3000-86-4
3000W
Three Phase
28V
107A
M3000-86-5
3000W
Three Phase
48V
63A
M3000-86-6
4000W
Three Phase
2V
800A
M4000-86-0
4000W
Three Phase
3.3V
800A
M4000-86-9
Notes
STANDARD CONTROL SIGNALS
1
Remote Enable
See Figure 1A
2
DC OK
(See Figures 2, 5)
Signal remains "Hi" as long as
output is ±5.0% of nominal
3
AC Good
(See Figures 2, 5)
Signal "Hi" when AC >175VAC
and "Lo" when <175VAC
Margin Hi/Lo (V1)
(See Figure 3)
Switch closure allows ±5.0% change
in output for system margin checking
Units available with 4.5V, 5.2V, 10V, 13V, 20V, 30V and 32V. Please consult
factory for further details.
Consult factory for any output voltage requirement up to 60VDC which is
not listed.
Models with ‘-26’ are single phase input; ‘-86’ indicates 3 phase input.
FIG. 5
Remote Adjust
(See Figure 4)
AC Power Fail Signal/DC
OK Timing
AC Input Voltage
180Vrms
0V
> 10ms
The outputs may be remotely
adjusted linearly ±10% for
system margin checking
Power Fail
Current Monitor
Analog signal indicates load current in
single or parallel operation. 5±0.5VDC
represents FL, resistive load 103kΩ
Supply Fault
> 5msec
DC Outputs
Overvoltage, overtemperature
indicated by 'low' signal
FIG. 1A
FIG. 1B
5V
5V
FIG. 2 (Ref. FIG. 5)
5V
FIG. 3
5V
3
FIG. 4
5V
Close to
Margin High
3
6
5V = -10%
5K
5K
7
>10K
2.5V Nominal
10K
(optional)
10
10
Close to
Enable
DC Good Flag
Close to
Inhibit
(optional)
http://www.artesyn.com
13
Return = +10%
Close to
Margin Low
PAGE 2
3000-4000W AC/DC
|
MEDIUM TO HIGH POWER AC/DC POWER SUPPLIES
3000 and 4000 Watt
AC/DC high current power supplies with PFC
PIN NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Mechanical notes
OUTPUT PIN CONNECTIONS
J1
REFERENCE
+ Remote Sense
Note 1
- Remote Sense
Note 1
Enable
Notes 2 & 4, Fig. 1
DC OK Inverse (Optional)
Notes 3 & 4, Fig. 2
AC Good Inverse
Notes 3 & 4, Fig. 2
Margin High
Fig. 3
Remote Adjust
Fig. 4
Current Monitor
Note 6
Current Share
Note 6
Inhibit (Optional)
Notes 2 & 4, Fig. 1
DC OK
Notes 3 & 4, Fig. 2 & 5
AC Good
Notes 3 & 4, Fig. 2 & 5
Margin Low
Note 3
Supply Fault
Notes 5 & 6
- Remote Sense
A AC connector is 4 position terminal block (#8 screws included), mating to
#8 ring tongue terminal.
B DC output is 5/16-18 studs mating to 5/16 terminal lugs.
C J-1 signal connector is Molex 39-30-1140 or equivalent. Mating
connector is Molex 39-01-2140 or equivalent.
D J-2 signal connector is Molex 39-01-1120 or equivalent. Mating
connector is 39-01-2120 or equivalent.
E Signal connector contacts are Molex 39-00-0039 or equivalent.
F Auxiliary DC output(s) are 6 position terminal block (#8 screws included)
mating to #8 ring tongue terminal.
G TB1 and J2 are not installed on single output models.
Output pin connector notes
1
2
3
4
5
6
Use 20AWG or larger twisted pair.
Switch on voltage must be <0.5V @ 5mA.
Figure 2 transistor on when signal TRUE. On voltage is <0.5V @ 5mA.
VCC in figures 1 and 2 is supplied internally; ground is pin 15.
Overvoltage and overtemperature will force fault TRUE. On voltage is
<0.5V @ 5mA.
All I/O signals are referenced to pin 15.
8.00
(203.20)
Output Bus 0.31 X 1.00 (2)
(7.87 X 25.4 )
0.91
(23.11)
0.38
(9.65)
3Ø INPUT
VOLTAGE ADJ
OUTPUT GOOD
1.69
(42.93)
5.00
(127.0)
Pin 1
J1
2.69
(68.33)
Mounting
Surface
AC Input
Terminal Block
(# 8 Screws)
0.90
(22.86)
Signal Connector
15 Position D-SUB, Socket Contacts
13.50
(342.9)
0.25 Max.
(6.35)
0.75
(19.05)
6.75
(171.45)
0.35
(8.89)
1.13
(28.70)
Ø 0.257
(6.53)
x2
Ø 0.316
(8.03)
x2
5.75
(146.05)
AIRFLOW
8-32 X 0.19 (4.83) Deep Max.
ALL DIMENSIONS IN INCHES (mm)
PAGE 3
MEDIUM TO HIGH POWER AC/DC POWER SUPPLIES
|
3000-4000W AC/DC
3000 and 4000 Watt
AC/DC high current power supplies with PFC
TRANSIENT RESPONSE
EFFICIENCY V'S OUTPUT CURRENT
85
20
84
16
82
81
Overshoot (%)
% Efficiency (3Ø)
18
M-CASE
83
80
79
L-CASE
78
77
76
14
12
10
8
6
75
4
74
2
73
0
200
400
0
600
Output Current (AMPS) @ 5VDC
0
100
200
300
400
Output Current Step (AMPS)
POWER FACTOR V'S OUTPUT CURRENT
.96
.95
L-CASE
Power Factor (3Ø)
.94
.93
M-CASE
.92
.91
.90
.89
.88
.87
.86
.85
100
200
300
400
500
600
Output Current (AMPS) @ 5VDC
DS_M3000/M4000_19980401.PDF
International Safety Standard Approvals
TÜV VDE0805/EN60950/IEC950 File No. R9373263
UL1950 File No. E135734
CSA C22.2 No. 950 Bulletin No. 1402C
http://www.artesyn.com
PAGE 4