60 Watts LPS60 Series Total Power: 60-80 Watts Input Voltage: 85-264 VAC 120-300 VDC # of Outputs: Single Medical Electrical Specs Input Input range 85-264 VAC 120-300 VDC 47-440 Hz <18 A peak @ 115 VAC; <36 A peak @ 230 VAC, cold start @ 25°C 1.5 A max. (RMS) @ 115 VAC 70% typical at full load FCC Class A conducted CISPR 22 Class A conducted EN55022 class A conducted VDE 0878 PT3 class A conducted Frequency Inrush current Input current Efficiency EMI filter Special Features • • • • • • • • • • • Medical safety approvals Universal input 3” x 5” footprint Remote sense Built-in EMI filter Low output ripple Adjustable output Overvoltage protection Overload protection 110 KHz switching frequency LPX60 enclosure kit available Safety ground leakage current <75 µA @ 50/60 Hz, 264 VAC input Output Maximum power Adjustment range Hold-up time Overload protection Overvoltage protection Remote sense 60 W for convection; 80 W with 30 CFM forced air -5, +10% minimum 20 ms @ 60 W load, 115 VAC nominal line Short circuit protection on all outputs. Case overload protected @ 110-145% above peak rating 5 V output: 5.7-6.7 VDC. Other outputs 10% to 25% above nominal output Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. Environmental Operating temperature: 0° to 50°C ambient derate each output at 2.5% per degree from 50° to 70°C Electromagnetic susceptibility: designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Humidity: Operating; non-condensing 5% to 95% Safety VDE UL CSA CE 0750/EN60601-1 (IEC601) UL2601 CSA 22.2 No. 601.1 Mark (LVD) 21310-3336-0015 E182560 LR109492 Vibration: Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75 G peak 5 Hz to 500 Hz, operational Storage temperature: -40° to 85°C Temperature coefficient: ±.04% per °C MTBF demonstrated: >550,000 hours at full load and 25°C ambient conditions rev 08.11.04 94 Technical Support: (888) 41-ASTEC or (407) 241-2752 Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211 Asia (HK) 852-2437-9662 AMERICAS EUROPE ASIA 5810 Van Allen Way Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698 Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 44 (1384) 842-211 Facsimile: 44(1384) 843-355 Units 2111-2116, Level 21 Tower1, Metroplaza 223, Hing Fong Road Fwai Fong, New Territories Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426 Model Number Output Voltage Minimum Load Maximum Load with Convection Cooling Maximum Load with 30 CFM Forced Air Peak Load1 Regulation2 Ripple P/P (PARD)3 LPS63-M LPS64-M LPS65-M 12 V 15 V 24 V 0A 0A 0A 5A 4A 2.5 A 6.7 A 5.3 A 3.3 A 7.5 A 6A 3.8 A ±2% ±2% ±2% 120 mV 150 mV 240 mV 1. Peak current lasting <30 seconds with a maximum 10% duty cycle. 2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. LPS60 Medical Series Ordering Information Pin Assignments Connector LPS63-M LPS64-M LPS65-M SK1-1 SK1-3 Neutral Line Neutral Line Neutral Line SK2-1 SK2-2 SK2-3 SK2-4 SK2-5 SK2-6 SK201-1 SK201-2 +12 V +12 V +12 V Common Common Common +Sense -Sense +15 V +15 V +15 V Common Common Common +Sense -Sense +24 V +24 V +24 V Common Common Common +Sense -Sense Power Derating Curve 80W 30 CFM Forced Air Cooling 60W Output Power (Watts) 40W 20W Natural Convection Cooling 40W 30W 0W 0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C Mating Connectors AC Input: Molex 09-50-8031 (USA) 09-91-0300 (UK) PINS: 08-58-0111 DC Outputs: Molex 09-50-8061 (USA) 09-91-0600 (UK) PINS: 08-58-0111 Remote Sense: Molex 22-01-2025 PINS: 08-50-0114 TA – Ambient Temperature – °C 0.22" (5.6) M1 + SK201 _ 3.00" (76.2) 1 2 3 4 5 6 2.55" (64.8) SK 1 Astec Connector Kit #70-841-006, includes all of the above. Notes: 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is ±.02”. 3. Mounting holes M1 and M2 should be grounded for EMI purposes. 4. Mounting hole M1 is safety ground connection. 5. Specifications are for convection rating at factory settings at 115 VAC input, 25°C unless otherwise stated. 6. Warranty: 1 year 7. Weight: 0.75 lb. / 0.34 kg M2 GND 1 N 3 L 4.56" (115.8) 0.22" (5.6) Remote Sense Connector Voltage Adj. Pot SK 2 0.15" (4) DIA (4 places) 5.00" (127) 1.65" (41.9) 0.12" (3) www.astecpower.com 95