BB TMP102

 TMP102
SBOS397 – AUGUST 2007
Low Power Digital Temperature Sensor
With SMBus™/Two-Wire Serial Interface in SOT563
FEATURES
•
•
•
•
•
•
TINY SOT563 PACKAGE
ACCURACY: 0.5°C (–25°C to +85°C)
LOW QUIESCENT CURRENT:
10μA Active (max)
1μA Shutdown (max)
SUPPLY RANGE: 1.4V to 3.6V
RESOLUTION: 12 Bits
DIGITAL OUTPUT: Two-Wire Serial Interface
APPLICATIONS
•
•
•
•
•
•
•
•
•
PORTABLE AND BATTERY-POWERED
APPLICATIONS
POWER-SUPPLY TEMPERATURE
MONITORING
COMPUTER PERIPHERAL THERMAL
PROTECTION
NOTEBOOK COMPUTERS
BATTERY MANAGEMENT
OFFICE MACHINES
THERMOSTAT CONTROLS
ELECTROMECHANICAL DEVICE
TEMPERATURES
GENERAL TEMPERATURE MEASUREMENTS:
Industrial Controls
Test Equipment
Medical Instrumentations
DESCRIPTION
The TMP102 is a two-wire, serial output temperature
sensor available in a tiny SOT563 package.
Requiring no external components, the TMP102 is
capable of reading temperatures to a resolution of
0.0625°C.
The TMP102 features SMBus and two-wire interface
compatibility, and allows up to four devices on one
bus. It also features an SMB alert function.
The TMP102 is ideal for extended temperature
measurement in a variety of communication,
computer, consumer, environmental, industrial, and
instrumentation applications. The device is specified
for operation over a temperature range of –40°C to
+125°C.
Temperature
SCL
GND
ALERT
1
2
3
Diode
Temp.
Sensor
Control
Logic
6
DS
A/D
Converter
Serial
Interface
5
OSC
Config.
and Temp.
Register
4
SDA
V+
ADD0
TMP102
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas
Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
SMBus is a trademark of Intel, Inc.
All other trademarks are the property of their respective owners.
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of the Texas
Instruments standard warranty. Production processing does not
necessarily include testing of all parameters.
Copyright © 2007, Texas Instruments Incorporated
TMP102
www.ti.com
SBOS397 – AUGUST 2007
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be
more susceptible to damage because very small parametric changes could cause the device not to meet its published
specifications.
ORDERING INFORMATION (1)
(1)
PRODUCT
PACKAGE-LEAD
PACKAGE DESIGNATOR
PACKAGE MARKING
TMP102
SOT563
DRL
CBZ
For the most current package and ordering information, see the Package Option Addendum at the end of this document, or see the TI
web site at www.ti.com.
ABSOLUTE MAXIMUM RATINGS (1)
PARAMETER
TMP102
UNIT
Supply Voltage
3.6
V
Input Voltage (2)
–0.5 to +3.6
V
Operating Temperature
–55 to +150
°C
Storage Temperature
–60 to +150
°C
Junction Temperature
+150
°C
Human Body Model (HBM)
2000
V
Charged Device Model (CDM)
1000
V
Machine Model (MM)
200
V
ESD Rating
(1)
(2)
Stresses above these ratings may cause permanent damage. Exposure to absolute maximum conditions for extended periods may
degrade device reliability. These are stress ratings only, and functional operation of the device at these or any other conditions beyond
those specified is not supported.
Input voltage rating applies to all TMP102 input voltages.
PIN CONFIGURATION
DRL Package
SOT563
Top View
1
GND
2
ALERT
3
CBZ
2
SCL
6
SDA
5
V+
4
ADD0
Submit Documentation Feedback
TMP102
www.ti.com
SBOS397 – AUGUST 2007
ELECTRICAL CHARACTERISTICS
At TA = +25°C and VS = +1.4V to +3.6V, unless otherwise noted.
TMP102
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNIT
TEMPERATURE INPUT
+125
°C
–25°C to +85°C
0.5
2
°C
–40°C to +125°C
1
3
°C
0.2
0.5
°C/V
Range
–40
Accuracy (Temperature Error)
vs Supply
Resolution
°C
0.0625
DIGITAL INPUT/OUTPUT
Input Logic Levels:
VIH
0.7 (V+)
3.6
VIL
–0.5
0.3 (V+)
V
1
μA
Input Current
IIN
0 < VIN < 3.6V
V
Output Logic Levels:
VOL SDA
VOL ALERT
V+ > 2V, IOL = 3mA
0
0.4
V
V+ < 2V, IOL = 3mA
0
0.2 (V+)
V
V+ > 2V, IOL = 3mA
0
0.4
V
V+ < 2V, IOL = 3mA
0
0.2 (V+)
Resolution
12
Conversion Time
26
Conversion Modes
V
Bit
35
ms
CR1 = 0, CR0 = 0
0.25
Conv/s
CR1 = 0, CR0 = 1
1
Conv/s
CR1 = 1, CR0 = 0 (default)
4
Conv/s
CR1 = 1, CR0 = 1
8
Timeout Time
30
Conv/s
40
ms
POWER SUPPLY
Operating Supply Range
Quiescent Current
Shutdown Current
+1.4
IQ
ISD
Serial Bus Inactive, CR1 = 1, CR0 = 0 (default)
7
+3.6
V
10
μA
μA
Serial Bus Active, SCL Frequency = 400kHz
15
Serial Bus Active, SCL Frequency = 3.4MHz
85
Serial Bus Inactive
0.5
Serial Bus Active, SCL Frequency = 400kHz
10
μA
Serial Bus Active, SCL Frequency = 3.4MHz
80
μA
μA
1
μA
TEMPERATURE RANGE
Specified Range
–40
+125
Operating Range
–55
+150
Thermal Resistance, SOT563
θJA
142
Submit Documentation Feedback
°C
°C
°C/W
3
TMP102
www.ti.com
SBOS397 – AUGUST 2007
TYPICAL CHARACTERISTICS
At TA = +25°C and V+ = 3.3V, unless otherwise noted.
SHUTDOWN CURRENT vs TEMPERATURE
20
10
18
9
16
8
14
7
12
6
10
ISD (mA)
IQ (mA)
QUIESCENT CURRENT vs TEMPERATURE
(4 Conversions per Second)
3.6V Supply
8
6
3.6V Supply
4
3
4
1.4V Supply
2
1.4V Supply
2
1
0
0
-60 -40 -20
0
20
40
60
80
100 120 140 160
40
60
80
100 120 140 160
Figure 1.
Figure 2.
CONVERSION TIME vs TEMPERATURE
QUIESCENT CURRENT vs BUS FREQUENCY
(Temperature at 3.3V Supply)
100
38
90
36
80
34
70
1.4V Supply
30
20
Temperature (°C)
40
32
0
-60 -40 -20
Temperature (°C)
IQ (mA)
Conversion Time (ms)
5
60
50
28
40
26
30
3.6V Supply
24
20
22
10
+125°C
+25°C
-55°C
0
20
-60 -40 -20
0
20
40
60
80
1k
100 120 140 160
10k
100k
1M
10M
Temperature (°C)
Bus Frequency (Hz)
Figure 3.
Figure 4.
TEMPERATURE ERROR vs TEMPERATURE
TEMPERATURE ERROR AT +25°C
2.0
1.0
Population
Temperature Error (°C)
1.5
0.5
0
-0.5
-1.0
-1.5
Temperature Error (°C)
Figure 5.
4
Figure 6.
Submit Documentation Feedback
0.45
0.35
0.25
100 120 140 160
0.15
80
0.05
60
-0.05
40
Temperature (°C)
-0.15
20
-0.25
0
-0.35
-60 -40 -20
-0.45
-2.0
TMP102
www.ti.com
SBOS397 – AUGUST 2007
APPLICATION INFORMATION
The TMP102 is a digital temperature sensor that is
optimal for thermal-management and thermalprotection applications. The TMP102 is two-wire- and
SMBus interface-compatible, and is specified over a
temperature range of –40°C to +125°C.
Pull-up resistors are required on SCL, SDA, and
ALERT. A 0.01μF bypass capacitor is recommended,
as shown in Figure 7.
V+
0.01mF
POINTER REGISTER
Figure 8 shows the internal register structure of the
TMP102. The 8-bit Pointer Register of the device is
used to address a given data register. The Pointer
Register uses the two LSBs (see Table 11) to
identify which of the data registers should respond to
a read or write command. Table 1 identifies the bits
of the Pointer Register byte. During a write
command, P2 through P7 must always be '0'.
Table 2 describes the pointer address of the
registers available in the TMP102. Power-up reset
value of P1/P0 is '00'. By default, the TMP102 reads
the temperature on power-up.
5
To
Two-Wire
Controller
SCL
SDA
4
1
6
TMP102
3
Pointer
Register
ADD0
ALERT
(Output)
2
Temperature
Register
NOTE: SCL, SDA, and ALERT
pins require pull-up resistors.
SCL
Configuration
Register
GND
I/O
Control
Interface
Figure 7. Typical Connections
TLOW
Register
The temperature sensor in the TMP102 is the chip
itself. Thermal paths run through the package leads,
as well as the plastic package. The lower thermal
resistance of metal causes the leads to provide the
primary thermal path.
To maintain accuracy in applications requiring air or
surface temperature measurement, care should be
taken to isolate the package and leads from ambient
air temperature. A thermally-conductive adhesive is
helpful in achieving accurate surface temperature
measurement.
SDA
THIGH
Register
Figure 8. Internal Register Structure
Table 1. Pointer Register Byte
P7
P6
P5
P4
P3
P2
0
0
0
0
0
0
P1
P0
Register Bits
Table 2. Pointer Addresses
P1
P0
REGISTER
0
0
Temperature Register (Read Only)
0
1
Configuration Register (Read/Write)
1
0
TLOW Register (Read/Write)
1
1
THIGH Register (Read/Write)
Submit Documentation Feedback
5
TMP102
www.ti.com
SBOS397 – AUGUST 2007
TEMPERATURE REGISTER
The Temperature Register of the TMP102 is
configured as a 12-bit, read-only register
(Configuration Register EM bit = '0', see the
Extended Mode section), or as a 13-bit, read-only
register (Configuration Register EM bit = '1') that
stores the output of the most recent conversion. Two
bytes must be read to obtain data, and are described
in Table 3 and Table 4. Note that byte 1 is the most
significant byte, followed by byte 2, the least
significant byte. The first 12 bits (13 bits in Extended
mode) are used to indicate temperature. The least
significant byte does not have to be read if that
information is not needed. The data format for
temperature is summarized in Table 5 and Table 6.
One LSB equals 0.0625°C. Negative numbers are
represented in binary two's complement format.
Following power-up or reset, the Temperature
Register will read 0°C until the first conversion is
complete. Bit D0 of byte 2 indicates Normal mode
(EM bit = '0') or Extended mode (EM bit = '1') and
can be used to distinguish between the two
temperature register data formats. The unused bits in
the Temperature Register always read '0'.
Table 3. Byte 1 of Temperature Register(1)
D7
D6
D5
D4
D3
D2
D1
D0
T11
T10
T9
T8
T7
T6
T5
T4
(T12)
(T11)
(T10)
(T9)
(T8)
(T7)
(T6)
(T5)
(1) Extended mode 13-bit configuration shown in parenthesis.
Table 4. Byte 2 of Temperature Register(1)
D7
D6
D5
D4
D3
D2
D1
D0
T3
T2
T1
T0
0
0
0
0
(T4)
(T3)
(T2)
(T1)
(T0)
(0)
(0)
(1)
(1) Extended mode 13-bit configuration shown in parenthesis.
Table 5. 12-Bit Temperature Data Format (1)
(1)
TEMPERATURE (°C)
DIGITAL OUTPUT (BINARY)
HEX
128
0111 1111 1111
7FF
127.9375
0111 1111 1111
7FF
100
0110 0100 0000
640
80
0101 0000 0000
500
75
0100 1011 0000
4B0
50
0011 0010 0000
320
25
0001 1001 0000
190
0.25
0000 0000 0100
004
0
0000 0000 0000
000
–0.25
1111 1111 1100
FFC
–25
1110 0111 0000
E70
–55
1100 1001 0000
C90
The resolution for the Temp ADC in Internal Temperature mode is 0.0625°C/count.
For positive temperatures (for example, +50°C):
Two's complement is not performed on positive numbers. Therefore, simply convert the number to binary
code with the 12-bit, left-justified format, and MSB = 0 to denote a positive sign.
Example: (+50°C)/(0.0625°C/count) = 800 = 320h = 0011 0010 0000
For negative temperatures (for example, –25°C):
Generate the Two's Complement of a negative number by complementing the absolute value binary number
and adding 1. Denote a negative number with MSB = 1.
Example: (|–25°C|)/(0.0625°C/count) = 400 = 190h = 0001 1001 0000
Two's complement format: 1110 0110 1111 + 1 = 1110 0111 0000
6
Submit Documentation Feedback
TMP102
www.ti.com
SBOS397 – AUGUST 2007
Table 6. 13-Bit Temperature Data Format
TEMPERATURE (°C)
DIGITAL OUTPUT (BINARY)
HEX
150
0 1001 0110 0000
0960
128
0 1000 0000 0000
0800
127.9375
0 0111 1111 1111
07FF
100
0 0110 0100 0000
0640
80
0 0101 0000 0000
0500
75
0 0100 1011 0000
04B0
50
0 0011 0010 0000
0320
25
0 0001 1001 0000
0190
0.25
0 0000 0000 0100
0004
0
0 0000 0000 0000
0000
–0.25
1 1111 1111 1100
1FFC
–25
1 1110 0111 0000
1E70
–55
1 1100 1001 0000
1C90
CONFIGURATION REGISTER
ALERT (AL Bit)
The Configuration Register is a 16-bit read/write
register used to store bits that control the operational
modes of the temperature sensor. Read/write
operations are performed MSB first. The format and
power-up/reset value of the Configuration Register is
shown in Table 7. For compatability, the first byte
corresponds to the Configuration Register in the
TMP75 and TMP275. All registers are updated byte
by byte.
The AL bit is a read-only function. Reading the AL bit
will provide information about the comparator mode
status. The state of the POL bit inverts the polarity of
data returned from the AL bit. For POL = 0, the AL
bit will read as '1' until the temperature equals or
exceeds THIGH for the programmed number of
consecutive faults, causing the AL bit to read as '0'.
The AL bit will continue to read as '0' until the
temperature falls below TLOW for the programmed
number of consecutive faults, when it will again read
as '1'. The status of the TM bit does not affect the
status of the AL bit.
Table 7. Configuration and Power-Up/Reset
Format
BYTE
1
2
D7
D6
D5
D4
D3
D2
D1
D0
OS
R1
R0
F1
F0
POL
TM
SD
0
1
1
0
0
0
0
0
CR1
CR0
AL
EM
0
0
0
0
1
0
1
0
0
0
0
0
EXTENDED MODE (EM)
The Extended mode bit configures the device for
Normal mode operation (EM = 0) or Extended mode
operation (EM = 1). In Normal mode, the
Temperature Register and high- and low-limit
registers use a 12-bit data format. Normal mode is
used to make the TMP102 compatible with the
TMP75.
Extended mode (EM = 1) allows measurement of
temperatures above +128°C by configuring the
Temperature Register, and high- and low-limit
registers, for 13-bit data format.
CONVERSION RATE
The conversion rate bits, CR1 and CR0, configure
the TMP102 for conversion rates of 8Hz, 4Hz, 1Hz,
or 0.25Hz. The default rate is 4Hz. The TMP102 has
a typical conversion time of 26ms. To achieve
different conversion rates, the TMP102 makes a
conversion and after that powers down and waits for
the appropriate delay set by CR1 and CR0. Table 8
shows the settings for CR1 and CR0.
Table 8. Conversion Rate Settings
CR1
CR0
CONVERSION RATE
0
0
0.25Hz
0
1
1Hz
1
0
4Hz (default)
1
1
8Hz
Submit Documentation Feedback
7
TMP102
www.ti.com
SBOS397 – AUGUST 2007
After power-up or general-call reset, the TMP102
immediately starts a conversion, as shown in
Figure 9. The first result is available after 26ms
(typical). The active quiescent current during
conversion is 40μA (typical at +27°C). The quiescent
current during delay is 2.2μA (typical at +27°C).
Delay
TLOW
TMP102 ALERT PIN
(Comparator Mode)
POL = 0
(1)
TMP102 ALERT PIN
(Interrupt Mode)
POL = 0
26ms
26ms
Startup
THIGH
Measured
Temperature
TMP102 ALERT PIN
(Comparator Mode)
POL = 1
Start of
Conversion
TMP102 ALERT PIN
(Interrupt Mode)
POL = 1
NOTE: (1) Delay is set by CR1 and CR0.
Figure 9. Conversion Start
Read
SHUTDOWN MODE (SD)
The Shutdown mode bit saves maximum power by
shutting down all device circuitry other than the serial
interface, reducing current consumption to typically
less than 0.5μA. Shutdown mode is enabled when
the SD bit is '1'; the device shuts down when current
conversion is completed. When SD is equal to '0',
the device maintains a continuous conversion state.
THERMOSTAT MODE (TM)
The Thermostat mode bit indicates to the device
whether to operate in Comparator mode (TM = 0) or
Interrupt mode (TM = 1). For more information on
comparator and interrupt modes, see the High- and
Low-Limit Registers section.
POLARITY (POL)
The Polarity bit allows the user to adjust the polarity
of the ALERT pin output. If POL = 0, the ALERT pin
will be active low, as shown in Figure 10. For POL =
1, the ALERT pin will be active high, and the state of
the ALERT pin is inverted.
8
Read
Read
Time
Figure 10. Output Transfer Function Diagrams
FAULT QUEUE (F1/F0)
A fault condition exists when the measured
temperature exceeds the user-defined limits set in
the THIGH and TLOW registers. Additionally, the
number of fault conditions required to generate an
alert may be programmed using the fault queue. The
fault queue is provided to prevent a false alert as a
result of environmental noise. The fault queue
requires consecutive fault measurements in order to
trigger the alert function. Table 9 defines the number
of measured faults that may be programmed to
trigger an alert condition in the device. For THIGH and
TLOW register format and byte order, see the Highand Low-Limit Registers section.
Table 9. TMP102 Fault Settings
F1
F0
CONSECUTIVE FAULTS
0
0
1
0
1
2
1
0
4
1
1
6
Submit Documentation Feedback
TMP102
www.ti.com
SBOS397 – AUGUST 2007
CONVERTER RESOLUTION (R1/R0)
R1/R0 are read-only bits. The TMP102 converter
resolution is set on start up to '11'. This sets the
temperature register to a 12 bit-resolution.
ONE-SHOT/CONVERSION READY (OS)
The TMP102 features a One-Shot Temperature
Measurement mode. When the device is in
Shutdown mode, writing a ‘1’ to the OS bit starts a
single
temperature
conversion.
During
the
conversion, the OS bit reads '0'. The device returns
to the shutdown state at the completion of the single
conversion. After the conversion, the OS bit reads '1'.
This feature is useful for reducing power
consumption in the TMP102 when continuous
temperature monitoring is not required.
Both operational modes are represented in
Figure 10. Table 10 and Table 11 describe the
format for the THIGH and TLOW registers. Note that the
most significant byte is sent first, followed by the
least significant byte. Power-up reset values for
THIGH and TLOW are: THIGH = +80°C and TLOW =
+75°C. The format of the data for THIGH and TLOW is
the same as for the Temperature Register.
Table 10. Bytes 1 and 2 of THIGH Register(1)
BYTE
1
BYTE
2
D7
D6
D5
D4
D3
D2
D1
H11
H10
H9
H8
H7
H6
H5
H4
(H12)
(H11)
(H10)
(H9)
(H8)
(H7)
(H6)
(H5)
D7
D6
D5
D4
D3
D2
D1
D0
H3
H2
H1
H0
0
0
0
0
(H4)
(H3)
(H2)
(H1)
(H0)
(0)
(0)
(0)
As a result of the short conversion time, the TMP102
can achive a higher conversion rate. A single
conversion typically takes 26ms and a read can take
place in less than 20μs. When using One-Shot
mode, 30 or more conversions per second are
possible.
(1) Extended mode 13-bit configuration shown in parenthesis.
HIGH- AND LOW-LIMIT REGISTERS
BYTE
In Comparator mode (TM = 0), the ALERT pin
becomes active when the temperature equals or
exceeds the value in THIGH and generates a
consecutive number of faults according to fault bits
F1 and F0. The ALERT pin remains active until the
temperature falls below the indicated TLOW value for
the same number of faults.
In Interrupt mode (TM = 1), the ALERT pin becomes
active when the temperature equals or exceeds the
value in THIGH for a consecutive number of fault
conditions (as shown in Table 9). The ALERT pin
remains active until a read operation of any register
occurs, or the device successfully responds to the
SMBus Alert Response address. The ALERT pin will
also be cleared if the device is placed in Shutdown
mode. Once the ALERT pin is cleared, it becomes
active again only when temperature falls below TLOW,
and remains active until cleared by a read operation
of any register or a successful response to the
SMBus Alert Response address. Once the ALERT
pin is cleared, the above cycle repeats, with the
ALERT pin becoming active when the temperature
equals or exceeds THIGH. The ALERT pin can also be
cleared by resetting the device with the General Call
Reset command. This action also clears the state of
the internal registers in the device, returning the
device to Comparator mode (TM = 0).
D0
Table 11. Bytes 1 and 2 of TLOW Register(1)
BYTE
1
2
D7
D6
D5
D4
D3
D2
D1
L11
L10
L9
L8
L7
L6
L5
D0
L4
(L12)
(L11)
(L10)
(L9)
(L8)
(L7)
(L6)
(L5)
D7
D6
D5
D4
D3
D2
D1
D0
L3
L2
L1
L0
0
0
0
0
(L4)
(L3)
(L2)
(L1)
(L0)
(0)
(0)
(0)
(1) Extended mode 13-bit configuration shown in parenthesis.
BUS OVERVIEW
The device that initiates the transfer is called a
master, and the devices controlled by the master are
slaves. The bus must be controlled by a master
device that generates the serial clock (SCL), controls
the bus access, and generates the START and
STOP conditions.
To address a specific device, a START condition is
initiated, indicated by pulling the data-line (SDA) from
a high to low logic level while SCL is high. All slaves
on the bus shift in the slave address byte on the
rising edge of the clock, with the last bit indicating
whether a read or write operation is intended. During
the ninth clock pulse, the slave being addressed
responds to the master by generating an
Acknowledge and pulling SDA low.
Data transfer is then initiated and sent over eight
clock pulses followed by an Acknowledge Bit. During
data transfer SDA must remain stable while SCL is
high, because any change in SDA while SCL is high
will be interpreted as a START or STOP signal.
Once all data have been transferred, the master
generates a STOP condition indicated by pulling
SDA from low to high, while SCL is high.
Submit Documentation Feedback
9
TMP102
www.ti.com
SBOS397 – AUGUST 2007
SERIAL INTERFACE
The TMP102 operates as a slave device only on the
two-wire bus and SMBus. Connections to the bus
are made via the open-drain I/O lines SDA and SCL.
The SDA and SCL pins feature integrated spike
suppression filters and Schmitt triggers to minimize
the effects of input spikes and bus noise. The
TMP102 supports the transmission protocol for both
fast (1kHz to 400kHz) and high-speed (1kHz to
3.4MHz) modes. All data bytes are transmitted MSB
first.
SERIAL BUS ADDRESS
To communicate with the TMP102, the master must
first address slave devices via a slave address byte.
The slave address byte consists of seven address
bits, and a direction bit indicating the intent of
executing a read or write operation.
The TMP102 features an address pin to allow up to
four devices to be addressed on a single bus.
Table 12 describes the pin logic levels used to
properly connect up to four devices.
Table 12. Address Pin and Slave Addresses
DEVICE TWO-WIRE
ADDRESS
A0 PIN CONNECTION
1001000
Ground
1001001
V+
1001010
SDA
1001011
SCL
WRITING/READING OPERATION
Note that register bytes are sent with the most
significant byte first, followed by the least significant
byte.
SLAVE MODE OPERATIONS
The TMP102 can operate as a slave receiver or
slave transmitter. As a slave device, the TMP102
never drives the SCL line.
Slave Receiver Mode:
The first byte transmitted by the master is the slave
address, with the R/W bit low. The TMP102 then
acknowledges reception of a valid address. The next
byte transmitted by the master is the Pointer
Register. The TMP102 then acknowledges reception
of the Pointer Register byte. The next byte or bytes
are written to the register addressed by the Pointer
Register. The TMP102 acknowledges reception of
each data byte. The master can terminate data
transfer by generating a START or STOP condition.
Slave Transmitter Mode:
Accessing a particular register on the TMP102 is
accomplished by writing the appropriate value to the
Pointer Register. The value for the Pointer Register
is the first byte transferred after the slave address
byte with the R/W bit low. Every write operation to
the TMP102 requires a value for the Pointer Register
(see Figure 13).
When reading from the TMP102, the last value
stored in the Pointer Register by a write operation is
used to determine which register is read by a read
operation. To change the register pointer for a read
operation, a new value must be written to the Pointer
10
Register. This action is accomplished by issuing a
slave address byte with the R/W bit low, followed by
the Pointer Register byte. No additional data are
required. The master can then generate a START
condition and send the slave address byte with the
R/W bit high to initiate the read command. See
Figure 14 for details of this sequence. If repeated
reads from the same register are desired, it is not
necessary to continually send the Pointer Register
bytes, because the TMP102 remembers the Pointer
Register value until it is changed by the next write
operation.
The first byte transmitted by the master is the slave
address, with the R/W bit high. The slave
acknowledges reception of a valid slave address.
The next byte is transmitted by the slave and is the
most significant byte of the register indicated by the
Pointer Register. The master acknowledges
reception of the data byte. The next byte transmitted
by the slave is the least significant byte. The master
acknowledges reception of the data byte. The master
can terminate data transfer by generating a
Not-Acknowledge on reception of any data byte, or
generating a START or STOP condition.
Submit Documentation Feedback
TMP102
www.ti.com
SBOS397 – AUGUST 2007
SMBus ALERT FUNCTION
HIGH-SPEED (Hs) MODE
The TMP102 supports the SMBus Alert function.
When the TMP102 operates in Interrupt mode (TM =
'1'), the ALERT pin may be connected as an SMBus
Alert signal. When a master senses that an ALERT
condition is present on the ALERT line, the master
sends an SMBus Alert command (00011001) to the
bus. If the ALERT pin is active, the device
acknowledges the SMBus Alert command and
responds by returning its slave address on the SDA
line. The eighth bit (LSB) of the slave address byte
indicates if the ALERT condition was caused by the
temperature exceeding THIGH or falling below TLOW.
For POL = '0', this bit is low if the temperature is
greater than or equal to THIGH; this bit is high if the
temperature is less than TLOW. The polarity of this bit
is inverted if POL = '1'. Refer to Figure 15 for details
of this sequence.
In order for the two-wire bus to operate at
frequencies above 400kHz, the master device must
issue an Hs-mode master code (00001xxx) as the
first byte after a START condition to switch the bus
to high-speed operation. The TMP102 does not
acknowledge this byte, but switches its input filters
on SDA and SCL and its output filters on SDA to
operate in Hs-mode, allowing transfers at up to
3.4MHz. After the Hs-mode master code has been
issued, the master transmits a two-wire slave
address to initiate a data transfer operation. The bus
continues to operate in Hs-mode until a STOP
condition occurs on the bus. Upon receiving the
STOP condition, the TMP102 switches the input and
output filters back to fast-mode operation.
If multiple devices on the bus respond to the SMBus
Alert command, arbitration during the slave address
portion of the SMBus Alert command determines
which device will clear its ALERT status. The device
with the lowest two-wire address wins the arbitration.
If the TMP102 wins the arbitration, its ALERT pin
becomes inactive at the completion of the SMBus
Alert command. If the TMP102 loses the arbitration,
its ALERT pin remains active.
The TMP102 resets the serial interface if SCL is held
low for 30ms (typ). The TMP102 releases the bus if it
is pulled low and waits for a START condition. To
avoid activating the timeout function, it is necessary
to maintain a communication speed of at least 1kHz
for SCL operating frequency.
GENERAL CALL
The TMP102 responds to a two-wire General Call
address (0000000) if the eighth bit is '0'. The device
acknowledges the General Call address and
responds to commands in the second byte. If the
second byte is 00000110, the TMP102 internal
registers are reset to power-up values. The TMP102
does not support the General Address acquire
command.
TIMEOUT FUNCTION
NOISE
The TMP102 is a very low-power device and
generates very low noise on the supply bus.
Applying an RC filter to the V+ pin of the TMP102
can further reduce any noise the TMP102 might
propagate to other components. RF in Figure 11
should be less than 5kΩ and CF should be greater
than 10nF.
Supply Voltage
TMP102
RF £ 5kW
SCL
SDA
GND
V+
ALERT
ADD0
CF ³ 10nF
Figure 11. Noise Reduction
Submit Documentation Feedback
11
TMP102
www.ti.com
SBOS397 – AUGUST 2007
TIMING DIAGRAMS
The TMP102 is two-wire and SMBus compatible.
Figure 12 to Figure 15 describe the various
operations on the TMP102. Parameters for Figure 12
are defined in Table 13. Bus definitions are:
Bus Idle: Both SDA and SCL lines remain high.
Start Data Transfer: A change in the state of the
SDA line, from high to low, while the SCL line is
high, defines a START condition. Each data transfer
is initiated with a START condition.
Stop Data Transfer: A change in the state of the
SDA line from low to high while the SCL line is high
defines a STOP condition. Each data transfer is
terminated with a repeated START or STOP
condition.
Data Transfer: The number of data bytes transferred
between a START and a STOP condition is not
limited and is determined by the master device. It is
also possible to use the TMP102 for single byte
updates. To update only the MS byte, terminate the
communication by issuing a START or STOP
communication on the bus.
Acknowledge: Each receiving device, when
addressed, is obliged to generate an Acknowledge
bit. A device that acknowledges must pull down the
SDA line during the Acknowledge clock pulse in such
a way that the SDA line is stable low during the high
period of the Acknowledge clock pulse. Setup and
hold times must be taken into account. On a master
receive, the termination of the data transfer can be
signaled
by
the
master
generating
a
Not-Acknowledge ('1') on the last byte that has been
transmitted by the slave.
Table 13. Timing Diagram Definitions
FAST MODE
PARAMETER
HIGH-SPEED MODE
TEST CONDITIONS
MIN
MAX
MIN
MAX
UNIT
f(SCL)
SCL Operating Frequency, VS > 1.7V
0.001
0.4
0.001
3.4
MHz
f(SCL)
SCL Operating Frequency, VS < 1.7V
0.001
0.4
0.001
2.75
MHz
t(BUF)
Bus Free Time Between STOP and START
Condition
600
160
ns
t(HDSTA)
Hold time after repeated START condition.
After this period, the first clock is generated.
100
100
ns
t(SUSTA)
Repeated START Condition Setup Time
100
100
ns
t(SUSTO)
STOP Conditon Setup Time
100
100
ns
t(HDDAT)
Data Hold Time
0
0
ns
t(SUDAT)
Data Setup Time
100
10
ns
t(LOW)
SCL Clock Low Period, VS > 1.7V
1300
160
ns
t(LOW)
SCL Clock Low Period, VS < 1.7V
1300
200
ns
t(HIGH)
SCL Clock High Period
600
60
ns
tF
Clock/Data Fall Time
300
tR
Clock/Data Rise Time
300
tR
Clock/Data Rise Time for SCLK ≤ 100kHz
1000
12
Submit Documentation Feedback
ns
160
ns
ns
TMP102
www.ti.com
SBOS397 – AUGUST 2007
TWO-WIRE TIMING DIAGRAMS
t(LOW)
tF
tR
t(HDSTA)
SCL
t(HDSTA)
t(HIGH)
t(SUSTO)
t(SUSTA)
t(HDDAT)
t(SUDAT)
SDA
t(BUF)
P
S
S
P
Figure 12. Two-Wire Timing Diagram
1
9
1
9
¼
SCL
SDA
1
0
0
1
0
A1(1)
A0(1)
R/W
Start By
Master
0
0
0
0
0
0
P1
¼
P0
ACK By
TMP102
ACK By
TMP102
Frame 2 Pointer Register Byte
Frame 1 Two-Wire Slave Address Byte
9
1
1
9
SCL
(Continued)
SDA
(Continued)
D7
D6
D5
D4
D3
D2
D1
D0
D7
D6
D5
D4
D3
D2
ACK By
TMP102
D1
D0
ACK By
TMP102
Stop By
Master
Frame 4 Data Byte 2
Frame 3 Data Byte 1
NOTE: (1) The value of A0 and A1 are determined by the ADD0 pin.
Figure 13. Two-Wire Timing Diagram for Write Word Format
Submit Documentation Feedback
13
TMP102
www.ti.com
SBOS397 – AUGUST 2007
1
9
1
9
¼
SCL
SDA
1
0
0
1
0
A1
(1)
A0
(1)
R/W
Start By
Master
0
0
0
0
0
0
P1
P0
ACK By
TMP102
Stop By
Master
ACK By
TMP102
Frame 1 Two-Wire Slave Address Byte
Frame 2 Pointer Register Byte
1
9
1
9
SCL
(Continued)
¼
SDA
(Continued)
1
0
0
1
0
A1
(1)
A0
(1)
R/W
Start By
Master
D7
D6
D5
D4
D3
D1
¼
D0
From
TMP102
ACK By
TMP102
Frame 3 Two-Wire Slave Address Byte
1
D2
ACK By
Master
(2)
Frame 4 Data Byte 1 Read Register
9
SCL
(Continued)
SDA
(Continued)
D7
D6
D5
D4
D3
D2
D1
D0
From
TMP102
ACK By
Master
Stop By
Master
(3)
Frame 5 Data Byte 2 Read Register
NOTE: (1) The value of A0 and A1 are determined by the ADD0 pin.
(2) Master should leave SDA high to terminate a single-byte read operation.
(3) Master should leave SDA high to terminate a two-byte read operation.
Figure 14. Two-Wire Timing Diagram for Read Word Format
ALERT
1
9
1
9
SCL
SDA
0
Start By
Master
0
0
1
1
0
0
R/W
1
0
0
1
ACK By
TMP102
Frame 1 SMBus ALERT Response Address Byte
A0
From
TMP102
Status
NACK By
Master
Frame 2 Slave Address From TMP100
NOTE: (1) The value of A0 and A1 are determined by the ADD0 pin.
Figure 15. Timing Diagram for SMBus ALERT
14
A1
Submit Documentation Feedback
Stop By
Master
PACKAGE OPTION ADDENDUM
www.ti.com
15-Aug-2007
PACKAGING INFORMATION
Orderable Device
Status (1)
Package
Type
Package
Drawing
Pins Package Eco Plan (2)
Qty
TMP102AIDRLR
ACTIVE
SOT-553
DRL
6
4000 Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
TMP102AIDRLT
ACTIVE
SOT-553
DRL
6
250
CU NIPDAU
Level-1-260C-UNLIM
Green (RoHS &
no Sb/Br)
Lead/Ball Finish
MSL Peak Temp (3)
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in
a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2)
Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check
http://www.ti.com/productcontent for the latest availability information and additional product content details.
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements
for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered
at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and
package, or 2) lead-based die adhesive used between the die and leadframe. The component is otherwise considered Pb-Free (RoHS
compatible) as defined above.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame
retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material)
(3)
MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder
temperature.
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is
provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the
accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take
reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on
incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited
information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI
to Customer on an annual basis.
Addendum-Page 1
PACKAGE MATERIALS INFORMATION
www.ti.com
15-Aug-2007
TAPE AND REEL INFORMATION
Pack Materials-Page 1
PACKAGE MATERIALS INFORMATION
www.ti.com
Device
15-Aug-2007
Package Pins
Site
Reel
Diameter
(mm)
Reel
Width
(mm)
A0 (mm)
B0 (mm)
K0 (mm)
P1
(mm)
W
Pin1
(mm) Quadrant
TMP102AIDRLR
DRL
6
HNT
180
9
1.78
1.78
0.69
4
8
Q3
TMP102AIDRLT
DRL
6
HNT
180
9
1.78
1.78
0.69
4
8
Q3
TAPE AND REEL BOX INFORMATION
Device
Package
Pins
Site
Length (mm)
Width (mm)
Height (mm)
TMP102AIDRLR
DRL
6
HNT
202.0
201.0
28.0
TMP102AIDRLT
DRL
6
HNT
202.0
201.0
28.0
Pack Materials-Page 2
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements,
improvements, and other changes to its products and services at any time and to discontinue any product or service without notice.
Customers should obtain the latest relevant information before placing orders and should verify that such information is current and
complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s
standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this
warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily
performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and
applications using TI components. To minimize the risks associated with customer products and applications, customers should
provide adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask
work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services
are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such
products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under
the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is
accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an
unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Information of third parties
may be subject to additional restrictions.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service
voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business
practice. TI is not responsible or liable for any such statements.
TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would
reasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement
specifically governing such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications
of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related
requirements concerning their products and any use of TI products in such safety-critical applications, notwithstanding any
applications-related information or support that may be provided by TI. Further, Buyers must fully indemnify TI and its
representatives against any damages arising out of the use of TI products in such safety-critical applications.
TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are
specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military
specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is
solely at the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in
connection with such use.
TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products
are designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any
non-designated products in automotive applications, TI will not be responsible for any failure to meet such requirements.
Following are URLs where you can obtain information on other Texas Instruments products and application solutions:
Products
Applications
Amplifiers
amplifier.ti.com
Audio
www.ti.com/audio
Data Converters
dataconverter.ti.com
Automotive
www.ti.com/automotive
DSP
dsp.ti.com
Broadband
www.ti.com/broadband
Interface
interface.ti.com
Digital Control
www.ti.com/digitalcontrol
Logic
logic.ti.com
Military
www.ti.com/military
Power Mgmt
power.ti.com
Optical Networking
www.ti.com/opticalnetwork
Microcontrollers
microcontroller.ti.com
Security