CLARE LCA182S

LCA182
Single Pole OptoMOS® Relay
Load Voltage
Load Current
Max RON
Input Control Current
LCA182
350
120
35
0.25
Units
V
mA
Ω
mA
Features
• Lowest available input control current (0.25mA)
• Small 6 Pin DIP Package
• Low Drive Power Requirements (TTL/CMOS
Compatible)
• No Moving Parts
• High Reliability
• Arc-Free With No Snubbing Circuits
• 3750VRMS Input/Output Isolation
• No EMI/RFI Generation
• Machine Insertable, Wave Solderable
• Surface Mount and Tape & Reel Versions Available
Applications
• Telecommunications
• Telecom Switching
• Tip/Ring Circuits
• Modem Switching (Laptop, Notebook, Pocket
Size)
• Hookswitch
• Dial Pulsing
• Ground Start
• Ringer Injection
• Instrumentation
• Multiplexers
• Data Acquisition
• Electronic Switching
• I/O Subsystems
• Meters (Watt-Hour, Water, Gas)
• Medical Equipment—Patient/Equipment Isolation
• Security
• Aerospace
• Industrial Controls
Description
The LCA182 is a 1-Form-A solid state relay which
uses optically coupled MOSFET technology to
provide 3750VRMS of input to output isolation. It
features an extremely low input control current of
only 0.25mA, the lowest available in the Clare Solid
State Relay Family. The efficient MOSFET switches
and photovoltaic die use Clare’s patented OptoMOS
architecture. The optically-coupled input is controlled
by a highly efficient GaAIAs infrared LED. The
LCA182 can be used to replace mechanical relays
and offers the superior reliability associated with
semiconductor devices. Because they have no
moving parts, they offer faster, bounce-free switching
in a more compact surface mount or though hole
package.
Regulatory Information
• UL Recognized: E76270
• CSA Certified: LR43639-10
• Certified to:
• EN 60950
• EN 41003
Ordering Information
Part #
LCA182
LCA182S
LCA182STR
Description
6 Pin DIP (50/Tube)
6 Pin Surface Mount (50/Tube)
6 Pin Surface Mount (1000/Reel)
Pin Configuration
LCA182 Pinout
LCA182 Pinout
AC/DC Configuration
DC Only Configuration
1
6
2
— Control
3
NC
5
+ Control
4
1
6
2
— Control
3
NC
5
+ Control
Load
Do Not Use
Load
+ Load
— Load
4
Switching Characteristics of
Normally Open (Form A) Devices
10ms
CONTROL
+
90%
LOAD
10%
+
10%+
TON
DS-LCA182-R01.1
www.clare.com
TOFF
1
LCA182
Absolute Maximum Ratings (@ 25˚ C)
Parameter
Input Power Dissipation
Input Control Current
Peak (10ms)
Reverse Input Voltage
Blocking Voltage
Total Power Dissipation
Isolation Voltage
Input to Output
Operational Temperature
Storage Temperature
Soldering Temperature
DIP Package
Surface Mount Package
(10 Seconds Max.)
1
Derate Linearly 1.33 mw/˚C
2
Derate Linearly 6.67 mw/˚C
Ratings
1501
50
1
5
350
8002
Units
mW
mA
A
V
V
mW
3750
-40 to +85
-40 to +125
VRMS
°C
°C
+260
-+220
°C
°C
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Electrical Characteristics
Parameter
Output Characteristics @ 25°C
Load Current (Continuous)
AC/DC Configuration
DC Configuration
Peak Load Current
On-Resistance
AC/DC Configuration
DC Configuration
Off-State Leakage Current
Switching Speeds
Turn-On
Turn-Off
Output Capacitance
Input Characteristics @ 25°C
Input Control Current1
Input Dropout Current
Input Voltage Drop
Reverse Input Current
Common Characteristics @ 25°C
Input to Output Capacitance
1
2
Conditions
Symbol
Min
Typ
Max
Units
10ms
IL
IL
ILPK
-
-
120
200
350
mA
mA
mA
IL=120mA
IL=200mA
VL=350V
RON
RON
ILEAK
-
23
7
-
35
10
1
Ω
Ω
µA
IF=1mA, VL=10V
IF=1mA, VL=10V
50V; f=1MHz
TON
TOFF
COUT
-
25
3
3
-
ms
ms
pF
IL=120mA
IF=1mA
VR=5V
IF
IF
VF
IR
0.25
0.05
0.9
-
1.2
-
1.4
10
mA
mA
V
µA
-
CI/O
-
3
-
pF
It is recommended that the input control current be increased to 1mA in high temperature (over+55oC) operation.
www.clare.com
R01.1
LCA182
35
35
30
30
30
25
20
15
10
5
Device Count (N)
35
Device Count (N)
Device Count (N)
PERFORMANCE DATA*
25
20
15
10
1.19
1.21
1.23
15
10
0
0
1.17
20
5
5
0
25
1.25
21.5
21.7
21.9
22.1
22.3
22.5
390
22.7
400
410
420
430
440
450
Blocking Voltage (V)
LED Forward Voltage Drop (V)
30
30
25
20
15
10
5
25
Device Count (N)
35
Device Count (N)
Device Count (N)
)
35
25
20
15
10
5
0
0.15
0.20
15
10
5
0
0
0.10
20
0.25
0.10
0.15
LED Current (mA)
0.20
0.25
0.436
25
210
Load Current (mA)
Device Count (N)
20
15
10
5
0.213
0.223
0.233
0.536
0.014
180
0.012
160
140
120
IF=2mA
0.010
IF=1mA
0.008
0.006
100
AC/DC Configuration
80
IF=2mA
0.004
IF=1mA
0.002
0
0.203
0.516
0.016
60
0
0.496
LCA182
Typical Leakage vs. Temperature
(Measured across Pins 4 & 6)
DC Configuration
200
0.193
0.476
Turn-On (ms)
LCA182
Typical Load Current vs. Temperature
0.183
0.456
LED Current (mA)
-40
-20
0
20
40
60
80
100
0
120
-40
-20
0
20
40
60
80
100
Turn-Off (ms)
420
415
410
405
400
395
-20
0
20
40
60
80
100
5.000
4.500
4.000
3.500
3.000
2.500
2.000
1.500
1.000
0.500
0
IF=.25mA
IF=.5mA
IF=5mA
-40
-20
0
20
40
60
80
100
Turn-Off (ms)
425
Turn-On (ms)
Blocking Voltage (V)
430
-40
LCA182
Typical Turn-Off vs. Temperature
(Load Current = 70mADC)
LCA182
Typical Turn-On vs. Temperature
(Load Current = 70mADC)
LCA182
Typical Blocking Voltage
vs. Temperature
1.000
0.900
0.800
0.700
0.600
0.500
0.400
0.300
0.200
0.100
0
IF=.25mA
-40
-20
0
20
40
60
80
100
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application
department.
R01.1
www.clare.com
3
LCA182
PERFORMANCE DATA*
1.6
IF=50mA
1.2
IF=10mA
IF=5mA
IF=.25mA
1.0
0.8
-40
-20
0
20
40
60
80
100
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
0.7
0.6
Turn-Off (ms)
1.8
1.4
LCA182
Typical Turn-Off vs. LED Forward Current
(Load Current = 120mADC)
LCA182
Typical Turn-On vs. LED Forward Current
(Load Current = 120mADC)
Turn-On (ms)
LED Forward Voltage Drop (V)
LCA182
Typical LED Forward Voltage Drop
vs. Temperature
0.4
0.3
0.2
0.1
0
0
120
0.5
2
4
6
8
10
12
14
16
18
20
0
2
4
LED Forward Current (mA)
LCA182
Typical IF for Switch Operation
vs. Temperature
(Load Current = 70mADC)
LCA182
Typical On-Resistance vs. Temperature
(Load Current = 70mADC)
60
20
10
0.20
0.15
0.10
0.05
0
-40
-20
0
20
40
60
80
100
14
16
18
20
0.20
0.15
0.10
0.05
0.00
-40
-20
0
20
40
60
80
100
0.00
-40
-20
0
20
40
60
80
100
LCA182
Energy Rating Curve
150
100
Load Current (A)
Load Current (mA)
12
0.25
LED Current (mA)
30
LED Current (mA)
IF=1mA
IF=2mA
IF=5mA
10
0.30
0.25
40
8
LCA182
Typical IF for Switch Dropout
vs. Temperature
(Load Current = 70mADC)
0.30
50
6
LED Forward Current (mA)
50
0
-50
-100
-150
-3
-2
-1
0
1
Load Voltage (V)
2
3
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
1ms 10ms 100ms
1s
10s 100s
Time
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application
department.
4
www.clare.com
R01.1
MECHANICAL DIMENSIONS
6Pin DIP Through Hole (Standard)
PC Board Pattern
(Top View)
2.540 ± 0.127
6-0.800 DIA.
(0.100 ± 0.005)
(6-0.031 DIA.)
7.239 TYP
(0.285 TYP)
7.620 ± 0.127
6.350 ± 0.127
(0.300 ± 0.005)
(0.250 ± 0.005)
0.254 TYP
(0.010 TYP)
5.080 ± 0.127
(0.200 ± 0.005)
6Pin Surface Mount (“S” Suffix)
PC Board Pattern
(Top View)
Tape and Reel Packaging for 6 Pin DIP Surface Mount Package
330.2 DIA.
(13.00 DIA.)
Top Cover
Tape Thickness
0.102 MAX.
(0.004 MAX.)
W = 16.30 MAX
(0.642 MAX)
B0 = 10.30
(0.406)
Top Cover
Tape
Embossment Carrier
Embossment
K1 = 3.80
(0.150)
P = 12.00
(0.472)
K0 = 4.90
(0.193)
User Direction of Feed
A0 = 10.30
(0.406)
Dimensions
mm
(inches)
For additional information please visit our website at: www.clare.com
Clare, Inc. makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make changes to specifications and product descriptions
at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in Clare’s Standard Terms and Conditions of Sale, Clare, Inc. assumes no liability whatsoever, and
disclaims any express or implied warranty, relating to its products including, but not limited to, the implied warranty of merchantability, fitness for a particular purpose, or infringement of any intellectual property right.
The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other applications intended to support
or sustain life, or where malfunction of Clare’s product may result in direct physical harm, injury, or death to a person or severe property or environmental damage. Clare, Inc. reserves the right to discontinue or make
changes to its products at any time without notice.
Specification: DS-LCA182-R01.1
©Copyright 2003, Clare, Inc.
OptoMOS® is a registered trademark of Clare, Inc.
All rights reserved. Printed in USA.
9/17/03