VSBU-120 Dual Output Switching Power Supply Rev 12-2006 Features ·Universal Input Voltage 90-264 VAC, 130-370 VDC, 47-63 Hz ·Internal EMI filter ·Input connector mates with Molex housing 09-50-3051 and Molex 2478 and 2578 series crimp terminal ·Output connector mates with Molex housing 09-50-3131 and Molex 2478 and 2578 series crimp terminal ·Input Surge current, over voltage and over load protection ·Power factor correction ·Power fail detect (optional) ·Class I Insulation ·Size : 3” x 5” x 1.28”(1U) ·Two Year Warranty Model Number VSBU-120-D305 VSBU-120-D312 VSBU-120-D512 VSBU-120-D515 VSBU-120-D524A VSBU-120-D524B VSBU-120-D285 Output Voltage +3.3 VDC +5 VDC +3.3 VDC +12 VDC 5 VDC 12 VDC 5 VDC Output Current 1.5~15 A 0.8~6 A 1.5~15 A 0.6~6 A 1.5~15 A 0.8~6 A 1.5~15 A Total Regulation ±5% ±5% ±5% ±5% ±5% ±5% ±5% 15 VDC 5 VDC 24 VDC 5 VDC -24 DVC 28 VDC 5 VDC 0.6~6 A 1.5~15 A 0.4~3.5 A 1.5~15 A 0.2~2 A 0.4~3.92 A 0~2 A ±5% ±5% ±5% ±5% ±5% ±5% ±5% V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062 www.v-infinity.com Max Output Power 79.5 W 79.5 W 120 W 120 W 120 W 120 W 120 W 120 120 120 120 120 120 120 1-866-372-1258 W W W W W W W VSBU-120 Dual Output Switching Power Supply Rev 12-2006 Electrical Characteristics Parameter Input Voltage Input Frequency Power Factor Correction Output Power Range Input Current (low line) Input Current (high line) Low Line Inrush Current High Line Inrush Current Efficiency Line Regulation Load Regulation Over Voltage Protection Over Current Protection Transient Response Hold-Up Time Start up time Ripple & Noise (Peak to Peak) Safety Ground Leakage Current Temperature Coefficient Test Conditions Max. 264 370 63 1.0 120 1.7 1.0 15 30 88 1 5 132 Unit VAC VDC Hz 150 4 2 1 0.75 0.04 % mS mS S % mA %/°C Min. Typ. 0 -40 5 Derate linearly from 100% load at 50°C to 50% load at 70°C Max. 70 85 95 Unit °C °C % Test Conditions Primary to secondary Primary to ground Test voltage=500VDC at 220VAC at 110 VAC Max. Unit VDC VDC MΩ Class Class Full load at 90~260VAC at 90 to 264 VAC Full load at 115VAC Full load at 230VAC Full load, 25°C, cool start, at 115VAC Full load, 25°C, cool start, at 230VAC Full load, at 230VAC Full load at 230VAC Min. 90 130 47 0.95 0 70 Typ. 0.97 12 26 80 0.5 3 112 110 Full load to Half load, at 100VAC Full load, at 110VAC Full load, at 100VAC Full load, at 90VAC Full load, at 240VAC All output 16 0.3 1 0.2 0.4 -0.04 W A A A A % % % % Environmental Parameter Operating Temperature Storage Temperature Relative Humidity Derating Test Conditions Safety Specifications Parameter Dielectric withstanding voltage Dielectric withstanding voltage Isolation resistance EMI requirements for CISPR-22 EMI requirements for FCC part-15 Min. 4242 2121 50 B B Typ. V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise customers to verify the most up-to-date product information before placing orders. V-Infinity assumes no liability or responsibility for customer’s applications using V-Infinity products other than repair or replacing (at V-I’s option) V-Infinity products not meeting V-I’s published specifications. Nothing will be covered outside of standard product warranty. V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062 www.v-infinity.com 1-866-372-1258 VSBU-120 Dual Output Switching Power Supply Rev 12-2006 Mechanical Specifications 27.6 1.087 0.5 M3XP0.5(MOUNTING HOLES)X4 40.0 1.575 0.5 20.3 0.799 0.5 127.0 5.000 0.5 115.6 4.551 0.5 5.5 0.217 0.5 33.6 1.323 0.5 5.7 0.224 0.5 14.2 0.560 0.5 76.2 3.000 0.5 65.3 2.571 0.5 76.2 3.000 0.5 DC OUTPUT (OPTIONAL) L N G 10.9 0.429 0.5 AC INPUT 3.0 MAX 4.0(MOUNTING HOLES)X4 30.8 1.213 0.5 20.3 0.799 0.5 27.6 1.087 0.5 Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 (optional) Model VSBU-120-DXXX Vo1 Vo1 Vo2 Vo2 Vo2 Vo2 COM COM COM N/C COM COM PFD VSBU-120-D285 N/C N/C Vo1 Vo1 Vo1 Vo1 COM COM COM Vo3 COM COM PFD VSBU-120-D524A N/C N/C Vo1 Vo1 Vo1 Vo1 COM COM COM Vo3 COM COM PFD V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062 www.v-infinity.com 1-866-372-1258