1/5 VSCP-600 Series Switching Power Supply Rev 7-2007 Features ·Current Sharing capability ·Programmable Output Voltage ·Universal AC Input ·Short Circuit, overload, over voltage, over temperature protected ·Forced air cooling by built-in DC fan ·Power Failure Signal ·Built-in Remote Sense ·Built-in Remote Inhibit ·2 year warranty Ripple & Noise 3 Output Current Model VSCP-600-05 VSCP-600-09 VSCP-600-12 VSCP-600-15 VSCP-600-18 VSCP-600-24 VSCP-600-36 VSCP-600-48 VSCP-600-60 Output 1 5 V 9 V 12 V 15 V 18 V 24 V 36 V 48 V 60 V Minimum 0A 0A 0A 0A 0A 0A 0A 0A 0A Maximum 2 80/100 A 44/66 A 33/50 A 26/40 A 22/33.3 A 16/25 A 11/16.6 A 8/12 A 6/10 A Max. Power 500 W 600 W 600 W 600 W 600 W 600 W 600 W 600 W 600 W Regulation <1% <1% <1% <1% <1% <1% <1% <1% <1% (Vpp) 1% 1% 1% 1% 1% 1% 1% 1% 1% Efficiency 78% 83% 84% 85% 85% 88% 88% 89% 90% Notes: 1 Output voltage is measured at output power connector. 2 Maximum current is measured at 100-120V input / 200-240V input 3 Ripple and noise is measured from 10 KHz to 20 MHz at output terminals with 0.1 µF ceramic capacitor and a 22 µF electrolytic capacitor in parallel. Input Parameter Input frequency Input voltage Inrush Current Input Current Conditions/Description 100~120 / 200~240 VAC (see derating curve) (130~185 / 260~370) (VDC see derating curve) Peak measured at 230 VAC at full load, cold start at 230 VAC V-INFINITY LLC, 20050 SW 112th Ave., Tualatin, OR 97062 Min 47 100 130 1-866-372-1258 Nom 3.5 Max 63 240 370 60 Units Hz VAC VDC A A www.v-infinity.com 2/5 VSCP-600 Series Switching Power Supply Rev 7-2007 Output Parameter Conditions/Description Hold-up time Full load at 230 VAC Min Programming Output voltage programmable through external Nom Max Units 12 mS 25 100 % -7.5 +7.5 % 0~5V control voltage on VCI. Control voltage can also be obtained from VCO via a 470 KOhm pot. See application diagrams. Voltage adjustability Typical adjustment by potentiometer 25%-100% Adjustment by 1-5Vdc external control Temp. coefficient Remote Sense 0.04 %/ºC Designated as (VS+) and (VS-). Total voltage compensation for cable losses with Remote Inhibit respect to the main output. Designated as (INH), requires a low signal to inhibit the output. Current Sharing Designated as (PAR), use in parallel for forced current sharing function. Protection Circuit Parameter Overload Overvoltage Conditions/Description Min Nom Max Units Current limiting 3 times (1.5”, 3.0”, 5.0”), then intelligent auto recovery before shutdown 110 135 % General and Safety Parameter Operating temp. Operating humid. Storage temp. Storage humid. EMC Safety regulation Leakage current Conditions/Description Min Nom 0 20% -20 10 EN55022, EN610000-4-2,3,4,5,6,8,11, EN61000-3-2-3 ENV50204 Approved to UL/cUL 1950, TUV EN60950 at 240 VAC Max 50 90% 85 95% Units ºC RH ºC RH 3.5 mA Conditions/Description Max Units Kg mm Mechanical Parameter Weight Enclosure Min 290(L) x 120(W) x 67.5(H) Nom 2.3 Logic Connector Parameter Pin Assignments: Conditions/Description 1. INH - Remote On-Off / Remote Inhibit 2. GND - Return / Output Ground 3. PAR - Current Sharing / Parallel function 4. FAL - AC Fail Detect (must use 2KΩ pull up resistor) 5. 6. 7. 8. VCO - Reference output voltage (5-10 VDC) to be used for output programming VCI - Command input voltage for output programming VS(-) - Remote Sense (-) VS(+) - Remote Sense (+) V-INFINITY LLC, 20050 SW 112th Ave., Tualatin, OR 97062 1-866-372-1258 www.v-infinity.com 3/5 VSCP-600 Series Switching Power Supply Rev 7-2007 Logic Connections V-INFINITY LLC, 20050 SW 112th Ave., Tualatin, OR 97062 1-866-372-1258 www.v-infinity.com 4/5 VSCP-600 Series Switching Power Supply Rev 7-2007 V-INFINITY LLC, 20050 SW 112th Ave., Tualatin, OR 97062 1-866-372-1258 www.v-infinity.com 5/5 VSCP-600 Series Switching Power Supply Rev 7-2007 Mechanical Drawing CONTROL PIN ASSIGMENT VS+ Output Voltage Remote Sense+ VS - Output Voltage Remote Sense - VCI Command input voltage for output programming VCO 5-10 VDC reference for output programming FAL Power Failure detect PAR Current Sharing / Parallel function GND Return / Output Ground INH Inhibit / Remote On-Off V-INFINITY LLC, 20050 SW 112th Ave., Tualatin, OR 97062 1-866-372-1258 www.v-infinity.com