LEM HTFS800-P

Current Transducer HTFS 200..800-P/SP2
IPN = 200 - 400 - 800A
For the electronic measurement of currents : DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
All Data are given with a R L = 10 kΩ
Electrical data
Primary nominal
r.m.s. current
IPN (A)
Primary current
measuring range
IP (A)
200
400
800
VOUT
VREF
RL
ROUT
CL
VC
IC
Type
Features
• Hall effect measuring principle
• Galvanic isolation between primary
±300
±600
±1200
HTFS 200-P/SP2
HTFS 400-P/SP2
HTFS 800-P/SP2
Analog output voltage @ IP
IP = 0
Internal Reference1) - Output voltage
VREF Output impedance
VREF Load impedance
Output load resistance
Output impedance
Max. output capacitive load
Supply voltage (± 5 %)
Current consumption @ VC = 5 V
VREF ±(1.25·IP/IPN) V
VREF ± 0.025
V
1/2VC ± 0.025
V
typ. 200
Ω
≥ 200
kΩ
≥2
kΩ
< 10
Ω
<1
µF
5
V
22
mA
and secondary circuit
X
Accuracy @ IPN , TA = 25°C
Linearity 0 .. 1.5 x IPN
TCVOUT Thermal drift of VOUT @ IP = 0
TCVREF Thermal drift of VREF
TCVOUT / VREF Thermal drift of VOUT / VREF @ IP = 0
TCεG Thermal drift of the gain
VOM
Residual voltage @ IP = 0, after an overload of 3 x IPN DC
t ra
Reaction time @ 10 % of IPN
tr
Response time @ 90 % of IPN
di/dt di/dt accurately followed
Output noise (DC ..10 kHz)
(DC .. 1 MHz)
f
Frequency bandwidth (-3 dB) 3)
εL
Advantages
• Small size and space saving
• Only one design for wide current
ratings range
• High immunity to external
Accuracy - Dynamic performance data
2)
• Low power consumption
• Single power supply +5V
• Ratiometric offset
• TA = -40..+105 °C
• PCB fixation by 4 Ø1 pins
interference.
≤±1
≤±0.5
≤±0.3
≤±0.01
≤±0.2
% of IPN
% of IPN
mV/K
%/K
mV/K
≤±0.05% of reading/K
<±0.5
<3
<7
> 100
< 15
< 40
DC .. 20
% of IPN
µs
µs
A/µs
mVpp
mVpp
kHz
• VREF. IN/OUT
Applications
• Forklift drives
• AC variable speed drives
• Static converters for DC motor drives
• Battery supplied applications
• Uninterruptible Power Supplies
(UPS)
• Switched Mode Power Supplies
(SMPS)
• Power supplies for welding
applications.
General data
TA
TS
dCp
dCl
CTI
m
Ambient operating temperature
Ambient storage temperature
Creepage distance
Clearance distance
Comparative tracking index (Group IIIa)
UL94 classification
Mass
Standards
LEM Components
- 40 .. + 105
- 40 .. + 105
>4
>4
220
V0
60
°C
°C
mm
mm
V
g
EN 50178 (97-10-01)
041222/2
w w w .lem.com
Current Transducer HTFS 200..800-P/SP2
Insulation category
Vb
Vb
Vd
Ve
Vw
Nominal Voltage
with IEC 61010-1 standards and following conditions
- Single insulation
- Over voltage category III
- Pollution degree 2
- Heterogeneous field
Nominal Voltage
with EN 50178 standards and following conditions
- Reinforced insulation
- Over voltage category III
- Pollution degree 2
- Heterogeneous field
R.m.s. voltage for AC isolation test, 50/60 Hz, 1 mn
R.m.s. voltage for partial discharge extinction @ 10pC
Impulse withstand voltage 1.2/50µs
150
V r.m.s.
150
V r.m.s.
2.5
>1
4
kV
kV
kV
If insulated cable is used for the primary circuit, the
voltage category could be improved with the following table :
Cable insulation (primary)
Category
HAR 03
300V CAT III
HAR 05
400V CAT III
HAR 07
500V CAT III
Notes : 1) It is possible to overdrive VREF with an external reference voltage
between 2 - 2.8 V providing its ability to sink or source approx. 2.5 mA.
2)
Excluding offset.
3)
Small signal only to avoid excessive heatings of the magnetic core.
Safety :
Caution, risk of danger
Caution, risk of electrical shock
LEM Components
This transducer shall be used in accordance with manufacturer instruction.
Power supply shall be a low voltage source and shall have an efficient
protective system against over current.
Power supply must incorporate a circuit breaker.
This transducer shall be used in an electric/electronic equipment in respect
of standards rules and applicable safety requirements.
Primary bar and output terminals can provide hazardous voltage.
This transducer is a built in device, of which conducting parts must be
inaccessible by installation.
Protective envelope or additional shield must be used.
w w w .lem.com
HTFS 200..800-P/SP2
Dimensions (in mm)
Ip
40
0.5
16.5
33
R3
20.3
3
33
d22
26
16
5
3-P=2.54
4
1
4-d=1.0
4.5
3.5+/-1
4-0.25x0.5
7
Required Connection Circuit
Terminal Pin
HTFS
4
Ref-IN
Vref(IN/OUT)
Output
3 Output
2 0V
1
+5V
47nF
4.7nF
1...+5V
2...0V
3...Output
4...Vref(IN/OUT)
0V
+5V
47nF
Operation Principle
+Vc
Vout
Vref.(IN/OUT)
0V
Ip
Remarks
Mechanical characteristics
•
•
•
•
General tolerance
Fixation
Recommended PCB hole
Fastening & connection of secondary
Recommended PCB hole
± 0.2 mm
4 pins x Ø 1.0
Ø 1.2 mm
4 pins 0.5 x 0.25
Ø 0.7 mm
• VOUT is positive when IP flows in the direction of the arrow.
• Temperature of the primary conductor should not exceed
120°C.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.