Agilent U1230 Series Handheld Digital Multimeter (DMM) Data Sheet Whether it is dark, noisy or even dangerous, the U1230 Series handheld digital multimeter keeps you equipped with features that anticipate worstcase scenarios. The ergonomic shaped handheld allows you to single-handedly illuminate the test area with a built-in flashlight while selecting measurement functions using the rotary dial. Vsense performs non-contact voltage detection while continuity detection is made easy with the audible beeper alert and flashing backlight display. With the U1230 Series, you work better in the conditions you are in. Features • Built-in LED flashlight to illuminate test area • Flashing backlight as additional visual alert during continuity tests in noisy environments • Vsense to perform non-contact voltage detection • Data logging capability (stores up to 10 readings) • IR-to-USB connectivity to transfer data to PC for record Ergonomically shaped with a built-in flashlight Non-contact voltage detection with Vsense Built for handheld users working in a poorly lit environment, the U1230 Series allows you to single-handedly illuminate your test area while making measurements with its easily activated built-in flashlight. Its ergonomic shape fits your hand, while the easily accessible rotary dial allows selection of measurement functions. The Vsense, a unique feature found in the U1233 Series performs non-contact voltage detection. It delivers more safety while making measurements in dangerous working environments by avoiding any contact with hot or live wires. Upon detection of voltage, it produces a unique combination of beeping alert and blinking LED light to make measurements more efficiently – especially in a dark or noisy environment. Flashing backlight and beeping alert for continuity detection The U1230 Series is built for continuity detection in dark and noisy environments. Its audible beep and flashing backlight display provides increased visual and audio alert to indicate continuity. Take a Closer Look Flashing light and audible beep during presence of voltage1 Bar graph indication and frequency measurement path Allows flexibility to change measurement range Freezes and stores current measurement value Vsense performs non-contact voltage detection1 Low input impedance to eliminate ghost voltage measurement Ease viewing with display backlight or built-in flashlight Anti-slip rotary dial for easy measurement function selection Figure 2. The built-in flashlight as illustrated Figure 1. U1230 Series front view Notes: 1. Only applicable for the U1233 Series 2 Electrical Specifications DC specifications Function Accuracy ± (% of reading + counts Test of least significant digit) current Burden voltage/ shunt Input impedance Where (applicable) Where (applicable) Range Resolution U1231A/U1232A/ U1233A 600 mV1 6V 60 V 600 V 600 V (VZLOW)2 0.1 mV 0.001 V 0.01 V 0.1 V 0.1 V 0.5% + 2 0.5% + 2 0.5% + 2 0.5% + 2 2% + 3 NA NA NA NA NA NA NA NA NA NA 11.18 MΩ 11.18 MΩ 10.1 MΩ 10 MΩ 3 kΩ 600 Ω4 6 kΩ4 60 kΩ 600 kΩ 6 MΩ5 60 MΩ5 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ 0.9% + 3 0.9% + 3 0.9% + 3 0.9% + 3 0.9% + 3 1.5% + 3 0.57 mA 57 μA 5.7 μA 570 nA 100 nA/10 MΩ 100 nA/10 MΩ NA NA NA NA NA NA NA NA NA NA NA NA 2V 0.001 V 0.9% + 2 0.57 mA NA NA 60 μA1 600 μA1 6 A2 10 A2, 3 0.01 μA 0.1 μA 0.001 A 0.01 A 1.0% + 24 1.0% + 24 1.0% + 34 1.0% + 34 NA NA NA NA < 2.5 V/1 kΩ < 2.5 V/1 kΩ < 0.2 V/0.005 Ω < 0.4 V/0.005 Ω NA NA NA NA Where (applicable) Voltage Resistance Diode3 Current Notes for DC voltage specifications: 1. The accuracy of the 600 mV range is specified after the Null function is used to subtract the thermal effect (by shorting the test leads). 2. For VZLOW (low input impedance) measurements, auto-ranging is disabled and the multimeter’s range is set to 600 V in the manual ranging mode. Notes for resistance specifications: 1. Overload protection: 600 Vrms for short circuits with < 0.3 A current. 2. Maximum open voltage is < +3 V. 3. Built-in buzzer beeps when the resistance measured is less than 23 Ω ± 10 Ω. The multimeter can capture intermittent measurements longer than 1 ms. 4. The accuracy of the 600 Ω to 6 kΩ range is specified after the Null function is used to subtract the test lead resistance and thermal effect (by shorting the test leads). 5. For the ranges of 6 MΩ and 60 MΩ, the RH is specified for < 60%. Notes for diode specifications: 1. Overload protection: 600 Vrms for short circuits with < 0.3 A current. 2. Built-in buzzer beeps continuously when the voltage measured is less than 50 mV and beeps once for forward-biased diode or semiconductor junctions measured between 0.3 V and 0.8 V (0.3 V ≤ reading ≤ 0.8 V). 3. Open voltage for diode: < +3 V DC. 4. The maximum display for diode measurements is 2100 counts. Notes for DC current specifications: 1. Overload protection for 60 μA to 600 μA range: 600 Vrms for short circuits with < 0.3 A current. 2. Overload protection for 6 A to 10 A range: 11 A/1000 V; 10 × 38 mm fast-acting fuse. 3. Specification for 10 A range: 10 A continuous. Add 0.3% to the specified accuracy when measuring signals > 10 A to 20 A for 30 seconds maximum. After measuring currents > 10 A, cool down the multimeter for twice the duration of the measured time before proceeding with low current measurements. 4. Only applicable for the U1232/U1233 Series 3 Electrical Specifications AC specifications True rms AC voltage and AC current specifications Function Range Resolution Accuracy ± (% of reading + counts of least significant digit) 45 Hz to 500 Hz 500 Hz to 1 kHz Voltage 600 mV 0.1 mV 1.0% + 3 2.0% + 3 NA 6V 0.001 V 1.0% + 3 2.0% + 3 NA 60 V 0.01 V 1.0% + 3 2.0% + 3 NA 600 V 0.1 V 1.0% + 3 2.0% + 3 NA 3 Current1 Burden voltage/ shunt Where (applicable) 600 (VZLOW) 0.1 V 2.0% + 3 4.0% + 3 NA 60 μA2 0.01 μA 1.5% + 3 NA < 2.5 V/1 kΩ 600 μA2 0.1 μA 1.5% + 3 NA < 2.5 V/1 kΩ 0.001 A 1.5% + 3 NA < 0.2 V/0.005 Ω 0.01 A 1.5% + 3 NA < 0.4 V/0.005 Ω 6A 3 10 A3, 4 Notes for true rms ac voltage specifications: 1. Overload protection: 600 Vrms. For millivolt measurements, 600 Vrms for short circuits with < 0.3 A current. 2. Input impedance: 10 MΩ (nominal) in parallel with < 100 pF. 3. VZLOW input impedance: 3 kΩ (nominal). Notes for ac current specifications: 1. AC current measurement not available for U1231A model. 2. Overload protection for 60 μA to 600 μA range: 600 Vrms for short circuits with < 0.3 A current. 3. Overload protection for 6 A to 10 A range: 11 A/1000 V; 10 × 38 mm fast-acting fuse. 4. Specification for 10 A range: 10 A continuous. Add 0.3% to the specified accuracy when measuring signals > 10 A to 20 A for 30 seconds maximum. After measuring currents > 10 A, cool down the multimeter for twice the duration of the measured time before proceeding with low current measurements. Capacitance specifications Range Resolution Accuracy± (% of reading + counts of least significant digit) U1231A/U1232A/U1233A 1000 nF 1 nF 1.9% + 2 4 times/second 10 μF 0.01 μF 1.9% + 2 4 times/second 100 μF 0.1 μF 1.9% + 2 4 times/second Measuring rate (at full scale) 1000 μF 1 μF 1.9% + 2 1 time/second 10 mF 0.01 mF 1.9% + 2 0.1 time/second Notes : 1. Overload protection: 600 Vrms for short circuits with < 0.3 A current. 2. The accuracy of for all ranges is specified based on a film capacitor or better, and after the Null function is used to subtract the test lead resistance and thermal effect (by shorting the test leads). 3. The maximum display is 1200 counts. 4 Electrical Specifications Temperature specifications Thermal type K Accuracy± (% of reading + counts of least significant digit) U1233A Range Resolution –40 °C to 1372 °C 0.1 °C 1% + 1 °C –40 °F to 2502 °F 0.1 °F 1% + 1.8 °F Notes: 1. The specification above is specified after 60 minutes of warm up time. If the unit is exposed during storage in high humidity (condensing) environment, 120 minutes of operating time is required instead. 2. The accuracy does not include the tolerance of the thermocouple probe. 3. Do not allow the temperature sensor to contact a surface that is energized above 30 Vrms or 60 V DC. Such voltages poses a shock hazard. 4. Ensure that the ambient temperature is stable within ±1 ºC and that the Null function is used to reduce the test lead’s thermal effect and temperature offset. Before using Null function, set the multimeter to measure temperature without ambient compensation (°C) and keep the thermocouple probe as close as possible to the multimeter (avoid contact with any surface that has a different temperature from the ambient temperature). 5. When measuring temperature with respect to any temperature calibrator, try to set both the calibrator and multimeter with an external reference (without internal ambient compensation). If both the calibrator and multimeter are set with internal reference (with internal ambient compensation), some deviations may show between the readings of the calibrator and multimeter, This difference is caused from the calibrator and multimeters’s ambient compensation. The deviation can be reduced by keeping the multimeter close to the output terminal of calibrator. 6. The temperature calculation is specified according to the safety standards of EN/IEC-60548-1and NIST175. 7. The approximate ambient temperature (cold-junction compensation) is shown on the display when you have an open thermocouple. The open thermocouple message may be due to broken (open) probe or because no probe is installed into the input jacks of the multimeter. Frequency specifications Range Resolution Accuracy± (% of reading + counts of least significant digit) U1231A/U1232A/U1233A 99.99 Hz 0.01 Hz 0.1% + 2 999.9 Hz 0.1 Hz 0.1% + 2 9.999 kHz 1 Hz 0.1% + 2 99.99 kHz 10 Hz 0.1% + 2 Minimum input frequency 5 Hz Notes: 1. Overload protection: 600 V; input signal is < 20,000,000 V × Hz (product of voltage and frequency). 5 Electrical Specifications Frequency sensitivity specifications For voltage measurements Input range Minimum sensitivity (rms sine wave) 5 Hz to 50 kHz U1231A U1232A U1233A Maximum input for specified accuracy1 600 mV in Scale mode 50 mV 50 mV 50 mV 600 mV 120 mV 120 mV 120 mV 6V 0.6 V 0.6 V 0.6 V 60 V 5.0 V 5.0 V 5.0 V 600 V 50 V 50 V 50 V Notes: 1. Maximum input for specified accuracy, refer to “AC specifications” on page 106 of the User Guide. For current measurements Input range Maximum input for specified accuracy1 Minimum sensitivity (rms sine wave) 45 Hz to 5 kHz U1232A U1233A 60 μA 30 μA 30 μA 600 μA 30 μA 30 μA 6A 0.5 A 0.5 A 10 A 0.5 A 0.5 A Notes: 1. Maximum input for specified accuracy, refer to “AC specifications” on page 106 of the User Guide. Scale transfer (mV) Range Resolution Accuracy ± (% of reading + counts of least significant digit) U1231A/U1232A/U1233A DC 600 mV 0.1 mV 0.5% + 22 AC 600 mV 0.1 mV 1.0 % + 3 @ 45 Hz to 500 Hz 2.0 % + 3 @ 500 Hz to 1 kHz Notes: 1. Overload protection: 600 Vrms for short circuits with < 0.3 A current. 2. The accuracy of the DC 600 mV range is specified after the Null function is used to subtract the thermal effect (by shorting the test leads). 3. Input impedance: 10 MΩ (typical). 6 Electrical Specifications Display update rate (approximate) Function Times/second U1231A U1232A/U1233A AC V (V or mV) 5 5 DC V (V or mV) 5 5 AC V/DC V (VZLOW) 1 1 Scale transfer (mV) 5 5 Ω 5 5 Diode 5 5 Capacitance 4 (< 100 μF) 4 (< 100 μF) DC A (μA, mA, or A) NA 5 AC A (μA, mA, or A) NA 5 Frequency 1 (> 10 Hz) 1 (> 10 Hz) 7 General Specifications Parameter U1231A/U1232A/U1233A Power supply Battery type • 4 × 1.5 V AAA Alkaline battery (ANSI/NEDA 24A or IEC LR03), or • 4 × 1.5 V AAA Zinc Chloride battery (ANSI/NEDA 24D or IEC R03) Battery life • 500 hours typical (based on new Alkaline batteries) with backlight and flashlight disabled Low battery indication • Low battery indicator will flash when the battery voltage drops below approximately 4.4 V Power consumption 450 mVA maximum (with backlight and flashlight enabled) Fuse 10 × 38 mm 11 A/1000 V fast-acting fuse Display Liquid crystal display (LCD) (with maximum reading of 6600 counts) Operating environment • • • • Operating temperature from –10 °C to 55 °C, 0% to 80% RH Full accuracy up to 80% RH for temperatures up to 30 °C, decreasing linearly to 50% RH at 55 °C Altitude up to 2000 meters Pollution degree II Storage compliance –40 °C to 60 °C, 0% to 80% RH without batteries Safety compliance EN/IEC 61010-1:2001, ANSI/UL 61010-1:2004, and CAN/CSA-C22.2 No. 61010-1-04 Measurement category CAT III 600 V Electromagnetic compatibility (EMC) Commercial limits compliance with EN61326-1 Temperature coefficient 0.1 × (specified accuracy) / °C (from –10 °C to 18 °C, or 28 °C to 55 °C) Common Mode Rejection Ratio (CMRR) > 100 dB at DC, 50/60 Hz (1 kΩ unbalanced) Normal Model Rejection Ration (NMRR) > 60 dB at 50/60 Hz Dimensions (H x W x D) 169 mm × 86 mm × 52 mm Weight U1232A and U1233A: 371 grams (with batteries and holster) U1231A: 365 grams (with batteries and holster) Warranty • Three years for product1 • Three months for product’s accessories Calibration cycle One year Notes: 1. Please take note that for the product, the warranty does not cover: • Damage from contamination • Normal wear and tear of mechanical components • Manuals, fuses, and batteries Specification assumptions • Accuracy is given as ±(% of reading + counts of least significant digit) at 23 °C ± 5 °C, with relative humidity less than 80% RH. • AC V and AC A specifications are AC coupled, true RMS and are valid from 5% of range to 100% of range. • The crest factor may be up to 3.0 at full- scale (4000 counts) • For non- sinusoidal waveforms, add (2% reading + 2% full scale) typical. • After VZLOW (low input impedance) voltage measurements, wait at least 20 minutes for thermal impact to cool before proceeding with any other measurement. 8 Ordering Information Standard shipped items Standard U1231A, U1232A and U1233A include: • • • • Quick Start Guide Certificate of Calibration (CoC) U1167A 4 mm Tips probes test leads 4 x 1.5 V batteries Recommended accessories U1174A Soft carrying case U1168A Standard test lead kit U1173A IR-to-USB cable U1171A Magnetic hanging kit 9 www.agilent.com www.agilent.com/find/dmm For more information on Agilent Technologies’ products, applications or services, please contact your local Agilent office. The complete list is available at: Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. www.axiestandard.org AdvancedTCA® Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA® for general purpose and semiconductor test. Agilent is a founding member of the AXIe consortium. Agilent Advantage Services is committed to your success throughout your equipment’s lifetime. We share measurement and service expertise to help you create the products that change our world. To keep you competitive, we continually invest in tools and processes that speed up calibration and repair, reduce your cost of ownership, and move us ahead of your development curve. www.agilent.com/find/advantageservices www.lxistandard.org LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems. Agilent is a founding member of the LXI consortium. http://www.pxisa.org PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based highperformance measurement and automation system. Agilent Channel Partners www.agilent.com/find/channelpartners Get the best of both worlds: Agilent’s measurement expertise and product breadth, combined with channel partner convenience. www.agilent.com/quality www.agilent.com/find/contactus Americas Canada Brazil Mexico United States (877) 894 4414 (11) 4197 3500 01800 5064 800 (800) 829 4444 Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Other AP Countries 1 800 629 485 800 810 0189 800 938 693 1 800 112 929 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 (65) 375 8100 Europe & Middle East Belgium 32 (0) 2 404 93 40 Denmark 45 70 13 15 15 Finland 358 (0) 10 855 2100 France 0825 010 700* *0.125 €/minute Germany Ireland Israel Italy Netherlands Spain Sweden United Kingdom 49 (0) 7031 464 6333 1890 924 204 972-3-9288-504/544 39 02 92 60 8484 31 (0) 20 547 2111 34 (91) 631 3300 0200-88 22 55 44 (0) 118 9276201 For other unlisted Countries: www.agilent.com/find/contactus Revised: October 14, 2010 Product specifications and descriptions in this document subject to change without notice. © Agilent Technologies, Inc. 2011 Printed in USA, May 6, 2011 5990-7550EN