MPD MPL-03S-05E

MPL-03SE Series
Single Output, 3W
Ultra-Miniature SIP
AC/DC Power Supplies
Key Features:
Electrical Specifications
• 3W Output Power
• Universal 85-264 VAC Input
• EN 60950 Approved (UL)
• Meets IEC Safety Class II
• Single Regulated Output
• Meets EN 55022 Class A
• >300 kHour MTBF
• Ultra-Miniature “SIP” Case
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Input Voltage Range
Input Frequency
Input Current
Inrush Current
Standby Power
Min.
Typ.
85
100
47
See Model Selection Guide
115 VAC
20.0
230 VAC
40.0
0.3
Max.
264
400
63
Conditions
Min.
Typ.
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
±1.5
VIN = Min to Max
IOUT = 10% to 100%
±2.5
5V, 15V, 24V Models
120
9V, 12V Models
100
230 VAC
50
±0.02
Continuous (Autorecovery)
Max.
Units
VAC
VDC
Hz
A Pk
W
Output
Parameter
Output Voltage
Output Current
Output Voltage Accuracy, See Note 1
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Hold-Up Time
Temperature Coefficient
Short Circuit Protection
Over Temperature Protection
Units
%
%
240
150
mV P-P
mSec
%/°C
150
°C
Max.
Units
VAC
kHz
General
Parameter
Isolation Voltage
Switching Frequency
EMI Characteristics
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
PFMF
Voltage Dips
Conditions
Input to Output
Min.
3,000
Typ.
50
Standard
See Note 3
EN 55022
See Note 3
EN 55022
EN 61000-4-2
See Note 4
EN 61000-4-3
See Note 5
EN 61000-4-4
See Note 6
EN 61000-4-5
See Note 7
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
Min.
Typ.
Max.
Units
Class A
Class A
Criteria B; ±4 kV Contact
Criteria A; 10V/m
Criteria B; ±2 kV
Criteria B; ±1 kV /±2 kV
Criteria A; 3 Vrms
Criteria A; 10A/m
Criteria B; 0% - 70%
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Conditions
Max.
+85
+90
-40
+105
Free Air Convection (See Derating Curve)
RH, Non-condensing
85
Ambient
Case
Min.
-40
Typ.
+25
Units
°C
°C
°C
%
Physical
Case Size
Case Material
Weight
1.38 x 0.43 x 0.94 Inches (35.0 x 11.0 x 24.0 mm)
Non-Conductive Epoxy (UL94-V0)
0.35 Oz (10g)
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Class
Conditions
Min.
Typ.
MIL HDBK 217F, 25°C, Gnd Benign
300
EN 60950
IEC 61140 Class II
www.micropowerdirect.com
Max.
Units
kHours
www.micropowerdirect.com
Model Selection Guide
Notes:
Output
1. For the 5V output model, a 270 µF output filter capacitor is required.
Voltage Efficiency
Operation at no load will not damage the units, however, they may not meet all specifications.
Current (A)
Voltage Current Accuracy (%, Typ) 2.
3. All units are rated for EN 55022 (CE/RE) class A without external components. They will meet class B with
(VDC)
(mA
Max.)
(%)
115 VAC 230 VAC
the addition of the ACFM-01 (or a similar discrete filter circuit). Contact the factory for more information.
4. To meet the requirements of EN 61000-4-3, (10V/m) external components are needed. This can be done
0.120
0.060
5.0
500
±5.0
69
discretely, or with the addition of the ACFM-01. Contact the factory for more information.
5. To meet the requirements of EN 61000-4-4 (±4 kV), external components are needed. This can be done
0.120
0.060
9.0
333
±5.0
76
discretely, or with the addition of the ACFM-01. Contact the factory for more information.
6. To meet the requirements of EN 61000-4-5 (±4 kV/±4 kV), external components are needed. This can be
0.120
0.060
12.0
250
±8.0
78
done discretely, or with the addition of the ACFM-01. Contact the factory for more information.
0.120
0.060
15.0
200
±5.0
78
7. To meet the requirements of EN 61000-4-6 (3V rms), external components are needed. This can be done
discretely, or with the addition of the ACFM-01. Contact the factory for more information.
0.120
0.060
24.0
125
±5.0
78
8. It is recommended that a fuse be used on the input of a power supply for protection. For the
MPL-03SE series, a 1.0A/250 VAC slow blow should be used.
Input
Model
Number
MPL-03S-05E
MPL-03S-09E
MPL-03S-12E
MPL-03S-15E
MPL-03S-24E
Typical Connection
Output
The diagram below illustrates a typical application connection of the MPL-03SE series. Notes on this circuit (starting with the input circuit) are:
1. It is recommended that an external fuse and NTC be used. The recommended
fuse is a 1.0A/250V slow blow and for the NTC, a 5D-9.
2. An external MOV is recommended on the input to protect the unit in the event of
a surge. A 561KD14 or equivalent is recommended.
3. The filter capacitor C1 is required for EMC performance over the full input range.
The recommended value is 22 µF/400V.
4. Recommended output filtering capacitors are:
MPL-03S-05E
MPL-03S-09E
MPL-03S-12E
MPL-03S-15E
MPL-03S-24E
Typical Board Layout: With ACFM-01 Input Module (See note 5)
C2
1.0 µF/50V
1.0 µF/50V
1.0 µF/50V
1.0 µF/50V
1.0 µF/50V
C3
470 µF/35V
330 µF/35V
150 µF/35V
150 µF/35V
150 µF/35V
TVS
SMBJ7.0A
SMBJ12A
SMBJ20A
SMBJ20A
SMBJ30A
The output filtering capacitor (C3) is a high frequency, low resistance electrolytic
capacitor. Capacitor (C2) is ceramic. Voltage derating of capacitors should be 80%
or above.
5. Input noise and surge suppression modules are available for a number of MPD
AC/DC power supplies. An MPL-03SE connection with the ACFM-01 is illustrated
in the diagram at left. For pricing or full technical information on these modules
(ACFM-01 and ACFM-02) please contact the factory.
Pin Connections
Derating Curve
Pin
Function
Pin
Function
1
3
5
AC-Neutral
AC-Line
+VCAP
7
10
12
-VCAP
-VOUT
+VOUT
Mechanical Dimensions
Input Voltage Vs Load
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
FAX: (781) 344-8481
•
E-Mail: [email protected]