WWW.PHIHONG.COM 4/8 Ports 60W per Port Midspan POE480U-4UP for 10/100/1000 Base-T Networks Features Proprietary Detection, Disconnect and Overload Protection Low Cost Gigabit Compatible 19” Rack Mounting Kit Ships with Unit Applications Wireless Access Points Computer Workstations Safety Approvals cUL/UL CE Mechanical Characteristics Length: 438mm (17.25in) Width: 228mm (8.98in) Output Specifications Full Power -- 60W per Port No Power Management required Full Protection OTP, OCP, OVP 48V RPS Input (Optional) 1 Year Warranty Security Systems IP Cameras Height: 44.5 mm (1.75in) Weight: 1.0Kg (2.5lbs) Model Number of Ports POE480U-4UP (xxx) 4 POE480U-8UP (xxx) 8 Options: xxx= RPS for AC and DC input, DC for DC only, Neither RPS or DC is AC input only: Phihong is not responsible for any error, and reserves the right to make changes without notice. Please visit our website at www.phihong.com for the most up-to-date specifications and contact information. Revision 6/21/2012 POE480U-UP Characteristics INPUT: AC Input Voltage Range 90 to 264VAC Input Frequency 47-63Hz Input Current: 7.5A (RMS) maximum for 90VAC 3A (RMS) maximum for 240VAC Leakage Current: 3.5mA maximum @ 254VAC 60Hz AC Inrush Current: 30A (RMS) maximum for 115VAC WWW.PHIHONG.COM Isolation Test Primary to Secondary: 4242VDC for 1 minute Primary to Ground: 2121VDC for 1 minute Secondary to Ground: 2121VDC for 1 minute Immunity EN50082-1 ESD: RS: EFT: Surge: CS: Voltage Dips Harmonic: EN61000-4-2. Level 3 EN61000-4-3. Level 2 EN61000-4-4. Level 2 EN61000-4-5. Level 3 EN61000-4-6. Level 2 EN61000-4-11 EN61000-3-2 Class A DC Input (Optional) Voltage Range 44-57Vdc Source should be SELV and isolated from ground by 1500Vac IEEE 802.3af Interoperability 12.5k detection resistance required for full power UNH Interoperability report available upon request Input Current 10A Max FEATURES: OUTPUT: Over Voltage/Current, Short Circuit Protection Total Output Power 60W per port 240-480W Total Power Outputs equipped with short circuit protection and overload protection as per 802.3af specifications The output can be shorted permanently without damage Ripple and Regulation Over Temperature Protection 100mV maximum Automatic shutdown without damage Efficiency Indicators 75% (typical) at maximum load, and 120VAC 60Hz Hold-up Time 16mS min. at maximum load, and 120 VAC 60Hz Transient O/P Voltage Protection 60V maximum at switch on and off at any AC line Phase Green LED: Power detected “CONNECT” at 60W Yellow LED: Fault detected USB Diagnostics Port and NIC Interface USB “B” port for diagnostics and manual port control Windows GUI NIC interface for remote management via secure IP access Turn-On Delay Time 10 sec maximum at maximum load, and 120VAC 60Hz, 25Hz Input Connector AC Input IEC320 C14 DC Input Molex 39-30-0060 ENVIRONMENTAL: Output Connection Temperature Operation Non-operation 0 to +40°C -25 to +65°C Warranty Humidity Operation Non-Operation 4-pair powering for full power Pins 3,6, 4,5(+) Pins 1,2, 7,8 (-) 5 to 90% 5 to 90% EMI EN55022 Class B, FCC Class B with FTP cabling EN55022 Class A, FCC Class A with UTP cabling 1 Year Dimension Diagram WWW.PHIHONG.COM