MP2505W THRU MP2510W SINGLE-PHASE GLASS PASSIVATED SILICON BRIDGE RECTIFIER VOLTAGE RANGE 50 to 1000 Volts CURRENT 25 Amperes FEATURES Superior thermal desing 300 amperes surge rating // 1/4 universal faston terminal Hole thru for # 10 screw MECHANICAL DATA MP-25W * UL listed the recognized component directory, file #E94233 * Epoxy: Device has UL flammability classification 94V-O MAX. .311 (7.9) MIN. .787 (20.0) .043 (1.1) .039 (1.0) MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Ratings at 25 o C ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load. Hole for # 10 screw Min .469 (11.9) .429 (10.9) .732 (18.6) .693 (17.6) 1.142 (29) 1.102 (28) .200 (5.08) .142 (29.0) .102 (28.0) * * * * .732 (18.6) .693 (17.6) For capacitive load, derate current by 20%. Dimensions in inches and (millimeters) MAXIMUM RATINGS (At T A = 25oC unless otherwise noted) SYMBOL RATINGS MP2505W MP251W MP252W MP254W MP256W MP258W MP2510W UNITS Maximum Recurrent Peak Reverse Voltage VRRM 50 100 200 400 600 800 1000 Volts Maximum RMS Bridge Input Voltage VRMS 35 70 140 280 420 560 700 Volts Maximum DC Blocking Voltage VDC 50 100 200 400 600 800 1000 Maximum Average Forward Rectified Output Current at Tc = 55o C Peak Forward Surge Current 8.3 ms single half sine-wave superimposed on rated load (JEDEC method) RMS isolation voltage from case to lead 25.0 Amps I FSM 300 Amps VISO 2500 Volts Typical Thermal Resistance (from junction to case) R θJC 1.9 Typical Thermal Resistance (from junction to ambient) RθJA 19 T J, T STG -55 to + 150 Operating and Storage Temperature Range Volts IO 0 C/W 0 C o ELECTRICAL CHARACTERISTICS (At TA = 25 C unless otherwise noted) SYMBOL CHARACTERISTICS VF Maximum Forward Voltage Drop per element at 12.5A DC o Maximum Reverse Current at Rated @T A = 25 C DC Blocking Voltage per element @T C = 100 o C NOTE: 1. Suffix ”W” for wire type 2. ”Fully ROHS compliant”,”100% Sn plating(Pb-free). IR MP2505W MP251W MP252W MP254W MP256W MP258W MP2510W UNITS 1.1 Volts 5.0 uAmps 0.2 mAmps 2015-03 REV: B RATING AND CHARACTERISTIC CURVES ( MP2505W THRU MP2510W ) FIG. 2 - TYPICAL FORWARD CURRENT DERATING CURVE 500 400 300 200 100 0 100 1 2 4 6 8 10 20 40 60 80100 NUMBER OF CYCLES AT 60Hz FIG. 3- TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS 10 TJ = 25 Pulse Width = 300us 1% Duty Cycle 1.0 .1 .01 .6 AVERAGE FORWARD CURRENT, (A) 25 8.3ms Single Half Sine-Wave (JEDEC Method) 1.2 1.3 .7 .8 .9 1.0 1.1 INSTANTANEOUS FORWARD VOLTAGE, (V) INSTANTANEOUS REVERSE CURRENT, (uA) INSTANTANEOUS FORWARD CURRENT, (A) PEAK FORWARD SURGE CURRENT, (A) FIG. 1 - MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT 20 15 10 60 Hz RESISTIVE OR INDUCTIVE LOAD 5 0 0 50 100 CASE TEMPERATURE, ( 150 ) 175 FIG. 4 - TYPICAL REVERSE CHARACTERISTICS 100 10 TJ = 25 1 0.1 0 20 40 60 80 100 120 140 PERCENT OF RATED PEAK REVERSE VOLTAGE, ( %) RECTRON Attachment information about MP25XW 1. Internal Circuit 2. Marking on the body + AC Part No. Rectron Logo Plant - code M P25X VXXX Year - code Voltage-code 05-------50V 1-------100V 2-------200V 4-------400V 6-------600V 8-------800V 10-----1000V UL Logo Week - code 3. Items marked on the inner box and carton 3.1 On the box (for –B) CUSTOMER TYPE LOT NO. QUANTITY Q.A. DATE 3.2 On the carton CUSTOMER TYPE QUANTITY LOT NO. REMARK PACKAGING OF DIODE AND BRIDGE RECTIFIERS BULK PACK PACKAGE PACKING CODE MP-15/-25/-35W -B EA PER BOX 50 INNER BOX SIZE (mm) 206*208*57 CARTON SIZE (mm) 450*220*255 EA PER CARTON 400 GROSS WEIGHT(Kg) 8.26 DISCLAIMER NOTICE Rectron Inc reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or use of any product or circuit. Rectron products are not designed, intended or authorized for use in medical, life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.