SSDI SUM60UF_1

SUM60UF thru SUM90UF
and
SUM60UFSMS thru SUM90UFSMS
Solid State Devices, Inc.
14701 Firestone Blvd * La Mirada, Ca 90638
Phone: (562) 404-4474 * Fax: (562) 404-1773
[email protected] * www.ssdi-power.com
Designer’s Data Sheet
Part Number/Ordering Information
400 mA
ULTRA FAST RECOVERY RECTIFIER
6,000 thru 9,000 VOLTS
70 nsec
1/
SUM __ __ __
│
│
│
│
│
│
│
│
│
└
│ └ Screening 2/
│
__ = Not Screened
│
TX = TX Level
│
TXV = TXV Level
│
S = S Level
│
└ Package Type
__ = Axial Leaded
SMS = Surface Mount Square Tab
Voltage/Family
60UF = 6,000V
70UF = 7,000V
80UF = 8,000V
90UF = 9,000V
MAXIMUM RATINGS 3/
FEATURES:
•
•
•
•
•
•
•
•
PIV to 9,000 Volts
Hermetically sealed axial and square tab
surface mount package
4/
Ultra fast recovery 70 nsec maximum
Void free construction
Metallurgically bonded
175°C maximum operating temperature
2/
TX, TXV, and S-level screening available
Also available in fast versions, consult factory
6/
RATING
Peak Inverse Voltage
SUM60UF and SUM60UFSMS
SUM70UF and SUM70UFSMS
SUM80UF and SUM80UFSMS
SUM90UF and SUM90UFSMS
Average Rectified Current
Surge Current (1 Cycle)
Operating & Storage Temperature 5/
SYMBOL
VALUE
UNIT
PIV
6000
7000
8000
9000
Volts
IO1
IO2
400
250
mA
IFSM
25
Amps
TJ and
TSTG
-65 to +175
°C
TA = 25°C
TA = 100°C
NOTES:
1/ For ordering information, price, operating curves, and availability- contact factory.
2/ Screening based on MIL-PRF-19500. Screening flows available on request.
3/ Unless otherwise specified, all electrical characteristics @25ºC.
4/ IF = 500mA, IR = 1A, IRR = 250mA, TA = 25°C
5/ Maximum lead/end temperature for soldering is 250°C, 3/8” from case for 5 sec. maximum.
6/ Operating and testing over 10,000 V/inch may require encapsulation or immersion in
suitable dielectric material.
NOTE: All specifications are subject to change without notification.
SCD's for these devices should be reviewed by SSDI prior to release.
Axial Leaded
DATA SHEET #: RC0039E
SMS
DOC
SUM60UF thru SUM90UF
and
SUM60UFSMS thru SUM90UFSMS
Solid State Devices, Inc.
14701 Firestone Blvd * La Mirada, Ca 90638
Phone: (562) 404-4474 * Fax: (562) 404-1773
[email protected] * www.ssdi-power.com
ELECTRICAL CHARACTERISTICS 3/ 6/
CHARACTERISTICS
Maximum Forward Voltage
(300μs pulse minimum)
Maximum Reverse Leakage Current
(VR = Rated)
SYMBOL
VALUE
UNIT
IF = 400 mA
VF
15.5
Vdc
(TA = +25°C)
(TA =+100°C)
IR1
IR2
1.0
15
μA
μA
CJ
8
pF
trr
70
ns
RθJL
RθJE
18
18
°C/W
Maximum Junction Capacitance
VR = 100 Vdc, f = 1MHz, TA = 25°C
Maximum Reverse Recovery Time
IF = 500mA, IR = 1A, IRR = 250mA, TA = 25°C
Typical Thermal Impedance
Junction to Lead for Axial, L =.375"
Junction to End Tab for Surface Mount
Package Outlines:
DIMENSIONS (inches)
DIM.
A
B
C
D
Minimum
.065
--.047
1.00
Maximum
.165
.350
.053
---
AXIAL
NOTE: All specifications are subject to change without notification.
SCD's for these devices should be reviewed by SSDI prior to release.
DIMENSIONS (inches)
DIM.
A
B
C
D
Minimum
.170
.330
.020
.002
Maximum
.180
.380
.030
---
SMS
DATA SHEET #: RC0039E
DOC