Product data sheet Characteristics ATS01N109FT soft starter for asynchronous motor - ATS01 - 9 A - 110..480V - 1.1..4 KW Range of product Altistart 01 Product or component type Soft starter Product destination Asynchronous motors Product specific application Simple machine Component name ATS01 Network number of phases 3 phases Single phase Power supply voltage 110...480 V (- 10...10 %) Motor power kW 4 kW at 400 V 3 phases 1.1 kW at 230 V single phase 1.5 kW at 230 V 3 phases Motor power hp 1 hp at 210 V 3 phases 2 hp at 230 V 3 phases 5 hp at 460 V 3 phases Icl nominal current 9A Utilisation category AC-53B conforming to EN/IEC 60947-4-2 Current at nominal load 45 A at nominal load Type of start Start with voltage ramp Power dissipation in W 1 W at full load and at end of starting 46 W in transient state The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Main Complementary Assembly style With heat sink Function available Integrated bypass Power supply voltage limits 99...528 V Power supply frequency 50...60 Hz (- 5...5 %) Power supply frequency limits 47.5...63 Hz Output voltage <= power supply voltage Control circuit voltage 110 V +/- 10 % AC, 35 mA 24 V +/- 10 % AC/DC, 30 mA 240 V +/- 10 % AC, 80 mA Starting time 1 s/100 start(s) per hour 5 s/20 start(s) per hour Adjustable from 1 to 5 s Starting torque 30...80 % of starting torque of motor connected directly on the line supply Discrete output current 2 A DC-13 3 A AC-15 Tightening torque 0.5 N.m 1.9...2.5 N.m 10/8/2011 1 Electrical connection 1 conductor(s)rigid cable , connection via 4 mm screw clamp terminal 1...10 mm²/ AWG 8 for power circuit 1 conductor(s)rigid cable , connection via screw connector 0.5...2.5 mm²/AWG 14 for control circuit 2 conductor(s)rigid cable , connection via 4 mm screw clamp terminal 1...6 mm²/ AWG 10 for power circuit 2 conductor(s)rigid cable , connection via screw connector 0.5...1 mm²/AWG 17 for control circuit 1 conductor(s)flexible cable with cable end, connection via screw connector 0.5...1.5 mm²/AWG 16 for control circuit 1 conductor(s)flexible cable without cable end, connection via 4 mm screw clamp terminal 1.5...10 mm²/AWG 8 for power circuit 1 conductor(s)flexible cable without cable end, connection via screw connector 0.5...2.5 mm²/AWG 14 for control circuit 2 conductor(s)flexible cable with cable end, connection via 4 mm screw clamp terminal 1...6 mm²/AWG 10 for power circuit 2 conductor(s)flexible cable without cable end, connection via 4 mm screw clamp terminal 1.5...6 mm²/AWG 10 for power circuit 2 conductor(s)flexible cable without cable end, connection via screw connector 0.5...1.5 mm²/AWG 16 for control circuit Marking CE Operating position Vertical +/- 10 degree Product weight 0.28 kg Environment Electromagnetic compatibility Conducted and radiated emissions conforming to CISPR 11 level B Conducted and radiated emissions conforming to IEC 60947-4-2 level B Damped oscillating waves conforming to IEC 61000-4-12 level 3 Electrostatic discharge conforming to IEC 61000-4-2 level 3 EMC immunity conforming to EN 50082-1 EMC immunity conforming to EN 50082-2 Harmonics conforming to IEC 1000-3-2 Harmonics conforming to IEC 1000-3-4 Immunity to conducted interference caused by radio-electrical fields conforming to IEC 61000-4-6 level 3 Immunity to electrical transients conforming to IEC 61000-4-4 level 4 Immunity to radiated radio-electrical interference conforming to IEC 61000-4-3 level 3 Micro-cuts and voltage fluctuation conforming to IEC 61000-4-11 Voltage/Current impulse conforming to IEC 61000-4-5 level 3 Standards EN/IEC 60947-4-2 Product certifications B44.1-96/ASME A17.5 for starter wired to the motor delta terminal CCC CSA C-Tick GOST UL IP degree of protection IP20 Pollution degree 2 conforming to EN/IEC 60947-4-2 Vibration resistance 1 gn (f = 13...150 Hz) conforming to EN/IEC 60068-2-6 1.5 mm peak to peak (f = 3...13 Hz) conforming to EN/IEC 60068-2-6 Shock resistance 15 gn for 11 ms conforming to EN/IEC 60068-2-27 Relative humidity 5...95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 Ambient air temperature for operation -10...40 °C without derating 40...50 °C with current derating of 2 % per °C Ambient air temperature for storage -25...70 °C conforming to EN/IEC 60947-4-2 Operating altitude <= 1000 m without derating > 1000 m with current derating of 2.2 % per additional 100 m RoHS EUR status Compliant RoHS EUR conformity date 0905 2