ETC 5962-9960901HYA

REVISIONS
LTR
DESCRIPTION
DATE (YR-MO-DA)
APPROVED
REV
SHEET
REV
SHEET
15
16
17
18
REV STATUS
REV
OF SHEETS
SHEET
PMIC N/A
PREPARED BY
1
2
3
4
5
Steve Duncan
STANDARD
MICROCIRCUIT DRAWING
CHECKED BY
THIS DRAWING IS
AVAILABLE
FOR USE BY ALL
DEPARTMENTS
AND AGENCIES OF THE
DEPARTMENT OF DEFENSE
APPROVED BY
Raymond Monnin
AMSC N/A
6
7
8
9
10
11
12
13
14
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216
Michael Jones
MICROCIRCUIT, HYBRID, LINEAR, 12 VOLT,
DUAL CHANNEL, DC/DC CONVERTER
DRAWING APPROVAL DATE
00-08-09
REVISION LEVEL
SIZE
CAGE CODE
A
67268
SHEET
1 OF
DSCC FORM 2233
APR 97
DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.
5962-99609
18
5962-E469-00
1. SCOPE
1.1 Scope. This drawing documents five product assurance classes, class D (lowest reliability), class E, (exceptions), class G
(lowest high reliability), class H (high reliability), and class K, (highest reliability) and a choice of case outlines and lead finishes are
available and are reflected in the Part or Identifying Number (PIN). When available, a choice of radiation hardness assurance levels
are reflected in the PIN.
1.2 PIN. The PIN shall be as shown in the following example:
5962



Federal
stock class
designator
\
99609



RHA
designator
(see 1.2.1)
/
\/
Drawing number
01



Device
type
(see 1.2.2)
H



Device
class
designator
(see 1.2.3)
X



Case
outline
(see 1.2.4)
X



Lead
finish
(see 1.2.5)
1.2.1 Radiation hardness assurance (RHA) designator. RHA marked devices shall meet the MIL-PRF-38534 specified RHA
levels and shall be marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device.
1.2.2 Device type(s). The device type(s) identify the circuit function as follows:
Device type
Generic number
01
Circuit function
DC/DC converter, 96 W, ±12 V output
AFL12012D/CH
1.2.3 Device class designator. This device class designator shall be a single letter identifying the product assurance level as
follows:
Device class
Device performance documentation
D, E, G, H, or K
Certification and qualification to MIL-PRF-38534
1.2.4 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows:
Outline letter
U
X
Y
Z
Descriptive designator
See figure 1
See figure 1
See figure 1
See figure 1
Terminals
Package style
12
12
12
12
Y case configuration with leads bent upwards
Straight leads with end mounting thru holes
Straight leads with side mounting thru holes
Y case configuration with leads bent downwards
1.2.5 Lead finish. The lead finish shall be as specified in MIL-PRF-38534.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-99609
A
REVISION LEVEL
SHEET
2
1.3 Absolute maximum ratings. 1/
Input voltage range ................................................................................
Lead temperature (soldering, 10 seconds) ...........................................
Storage temperature range ...................................................................
-0.5 V dc to +180 V dc
+300°C
-65°C to +135°C
1.4 Recommended operating conditions.
Input voltage range ................................................................................
Output power 2/ 3/ ................................................................................
Case operating temperature range........................................................
+80 V dc to +160 V dc
≤ 96 W
-55°C to +125°C
2. APPLICABLE DOCUMENTS
2.1 Government specification, standards, and handbook. The following specification, standards, and handbook form a part of
this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the issue
of the Department of Defense Index of Specifications and Standards (DoDISS) and supplement thereto, cited in the solitation.
SPECIFICATION
DEPARTMENT OF DEFENSE
MIL-PRF-38534 - Hybrid Microcircuits, General Specification for.
STANDARDS
DEPARTMENT OF DEFENSE
MIL-STD-883 - Test Method Standard Microcircuits.
MIL-STD-1835 - Interface Standard for Microcircuit Case Outlines.
HANDBOOK
DEPARTMENT OF DEFENSE
MIL-HDBK-103 - List of Standard Microcircuit Drawings (SMD's).
MIL-HDBK-780 - Standard Microcircuit Drawings.
(Unless otherwise indicated, copies of the specification, standards, and handbooks are available from the Standardization
Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.)
2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text of
this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific
exemption has been obtained.
1/
2/
3/
Stresses above the absolute maximum rating may cause permanent damage to the device. Extended operation at the
maximum levels may degrade performance and affect reliability.
Derate output power linearly above case temperature +125°C to 0 at +135°C.
Output load must be distributed so that a minimum of 20% of the total output power is being provided by one of the outputs.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-99609
A
REVISION LEVEL
SHEET
3
3. REQUIREMENTS
3.1 Item requirements. The individual item performance requirements for device classes D, E, G, H, and K shall be in
accordance with MIL-PRF-38534. Compliance with MIL-PRF-38534 may include the performance of all tests herein or as
designated in the device manufacturer's Quality Management (QM) plan or as designated for the applicable device class.
Therefore, the tests and inspections herein may not be performed for the applicable device class (see MIL-PRF-38534).
Furthermore, the manufacturers may take exceptions or use alternate methods to the tests and inspections herein and not perform
them. However, the performance requirements as defined in MIL-PRF-38534 shall be met for the applicable device class.
3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified in
MIL-PRF-38534 and herein.
3.2.1 Case outline(s). The case outline(s) shall be in accordance with 1.2.4 herein and figure 1.
3.2.2 Terminal connections. The terminal connections shall be as specified on figure 2.
3.3 Electrical performance characteristics. Unless otherwise specified herein, the electrical performance characteristics are as
specified in table I and shall apply over the full specified operating temperature range.
3.4 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table II. The electrical tests
for each subgroup are defined in table I.
3.5 Marking of Device(s). Marking of device(s) shall be in accordance with MIL-PRF-38534. The device shall be marked with
the PIN listed in 1.2 herein. In addition, the manufacturer's vendor similar PIN may also be marked.
3.6 Data. In addition to the general performance requirements of MIL-PRF-38534, the manufacturer of the device described
herein shall maintain the electrical test data (variables format) from the initial quality conformance inspection group A lot sample, for
each device type listed herein. Also, the data should include a summary of all parameters manually tested, and for those which, if
any, are guaranteed. This data shall be maintained under document revision level control by the manufacturer and be made
available to the preparing activity (DSCC-VA) upon request.
3.7 Certificate of compliance. A certificate of compliance shall be required from a manufacturer in order to supply to this drawing.
The certificate of compliance (original copy) submitted to DSCC-VA shall affirm that the manufacturer's product meets the
performance requirements of MIL-PRF-38534 and herein.
3.8 Certificate of conformance. A certificate of conformance as required in MIL-PRF-38534 shall be provided with each lot of
microcircuits delivered to this drawing.
4. QUALITY ASSURANCE PROVISIONS
4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with MIL-PRF-38534 or as modified
in the device manufacturer's Quality Management (QM) plan. The modification in the QM plan shall not affect the form, fit, or
function as described herein.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-99609
A
REVISION LEVEL
SHEET
4
TABLE I. Electrical performance characteristics.
Test
Symbol
Output voltage
VOUT
Conditions
-55°C ≤ TC ≤ +125°C
VIN = 120 V dc ±5%, CL = 0
unless otherwise specified
Group A
Subgroups
IOUT = 4 A
1
Device
type
01
2,3
Output current
1/
Limits
Unit
Min
Max
±11.88
±12.12
±11.76
±12.24
6.4
V
IOUT
VIN = 80, 120, and 160 V dc,
either output
1,2,3
01
Output ripple voltage 2/
VRIP
VIN = 80, 120, and 160 V dc,
B.W. = 20 Hz to 10 MHz,
IOUT = 4 A, both outputs
1,2,3
01
80
Line regulation 3/
VRLINE
VIN = 80, 120, and 160 V dc,
IOUT = 0, 2, and 4 A, both
outputs
1,2,3
01
±60
mV
Load regulation 3/
VRLOAD
VIN = 80, 120, and 160 V dc,
IOUT = 0, 2, and 4 A, both ouputs
1,2,3
01
±120
mV
Cross regulation 4/
Positive output
VRCROS
VIN = 80, 120, and 160 V dc
1,2,3
01
±120
mV
mV p-p
±600
Negative output
Input current
A
IIN
IOUT = no load
1
01
20
2,3
25
Enable 1, (pin 4) shorted to
Input return (pin 2)
1,2,3
3
Enable 2, (pin 12) shorted to
Output return (pin 8)
1,2,3
5
Input ripple current 2/
IRIP
IOUT = 4 A,
B.W. = 20 Hz to 10 MHz
1,2,3
01
70
Efficiency
EFF
IOUT = 4 A, both outputs
1,2,3
01
82
Isolation
ISO
Input to output or any pin to
case (except pin 3) at 500 V dc,
TC =+25°C
1
01
100
Maximum capacitive
Load 5/
CL
No effect on dc performance,
each output, TC =+25°C
4
01
10,000
mA
mA p-p
%
MΩ
µF
See footnotes at end of table.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-99609
A
REVISION LEVEL
SHEET
5
TABLE I. Electrical performance characteristics - Continued.
Test
Symbol
Conditions
-55°C ≤ TC ≤ +125°C
VIN = 120 V dc ±5%, CL = 0
unless otherwise specified
Group A
Subgroups
Device
type
Limits
Min
Power dissipation load fault
PD
Overload 6/
1,2,3
01
ICL
Max
32
Short circuit
Current limit point 7/
Unit
W
32
VOUT = 90 % VNOM
1
01
4.6
5.0
2
4.2
5.0
3
4.6
5.8
A
Switching frequency
FS
4,5,6
01
500
600
kHz
Sync frequency range
FSYNC
4,5,6
01
500
700
kHz
Output response to step
transient load changes 8/
VOTLOAD
4,5,6
01
-750
+750
mV pk
-750
+750
50% to/from 100%
10% to/from 50%
Recovery time, step transient
load changes
8/ 9/
TTLOAD
50% to/from 100%
4,5,6
01
200
10% to/from 50%
µs
400
Output response to transient
step line changes 5/ 10/
VOTLINE
Input step 160 V to/from
400 V dc
4,5,6
01
Recovery time transient step
line changes 5/ 8/ 10/
TTLINE
Input step 160 V to/from
400 V dc
4,5,6
Turn on overshoot
VTonos
Enable 1 and 2 on. (Pins 4
and 12 high or open)
Turn on delay 11/
TonD
Enable 1 and 2 on. (Pins 4
and 12 high or open)
Load fault recovery 5/
TrLF
-500
+500
mV pk
01
500
µs
4,5,6
01
250
mV pk
4,5,6
01
120
ms
4,5,6
01
120
ms
See footnotes at top of next page.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-99609
A
REVISION LEVEL
SHEET
6
TABLE I. Electrical performance characteristics - Continued.
1/ Parameter guaranteed by line and load regulation tests.
2/ Bandwidth guaranteed by design. Tested for 20 kHz to 10 MHz.
3/ Load current split equally between +VOUT and -VOUT.
4/ Cross regulation measured with load on tested ouput at 20% while changing the load on the other from 20% to 80%.
5/ Parameter shall be tested as part of design characterization and after design or process changes. Thereafter,
parameters shall be guaranteed to the limits specified in table I.
6/ An overload is that condition with a load in excess of the rated load but less than that necessary to trigger the short
circuit protection and is the condition of maximum power dissipation.
7/ Current limit point is that condition of excess load causing output voltage to drop 90% of nominal.
8/ Load step transition time ≥ 10 microseconds.
9/ Recovery time is measured from the initiation of the transient to where VOUT has returned to within ± 1 percent of
VOUT at 50 percent load.
10/ Input step transition time ≥ 100 microseconds.
11/ Turn on delay is measured with an input voltage rise time of between 100 and 500 volts per millisecond.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-99609
A
REVISION LEVEL
SHEET
7
Case U
FIGURE 1. Case outline(s).
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-99609
A
REVISION LEVEL
SHEET
8
Case U - Continued
Millimeters
Min
Max
9.65
71.00
71.25
63.37
63.63
13.21
13.46
37.97
38.23
50.6
51.1
25.27
25.53
1.14
1.40
10.4
10.9
5.46
5.72
44.32
44.58
29.08
29.34
44.32
44.58
6.1
6.6
7.49
7.75
9.40
9.65
6.22
6.48
0.89
1.14
3.43
3.68
Symbol
A
D
D1
D2
E
e1
e2
F
L
L1
q
q1
q2
q3
q4
q5
S
∅b
∅p
Inches
Min
Max
.380
2.805
2.505
.530
1.505
2.01
1.005
.055
.43
.225
1.755
1.155
1.755
.26
.305
.380
.255
.045
.145
2.795
2.495
.520
1.495
1.99
.995
.045
.41
.215
1.745
1.145
1.745
.24
.295
.370
.245
.035
.135
NOTES:
1. The U.S. government preferred system of measurement is the metric SI. This item was designed using inch-pound
units of measurement. In case of problems involving conflicts between the metric and inch-pound units, the inchpound units shall rule.
2. Lead identification for reference only.
3. Case outline weight: 92 grams maximum.
FIGURE 1. Case outline(s) - Continued.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-99609
A
REVISION LEVEL
SHEET
9
Case X
FIGURE 1. Case outline - Continued.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-99609
A
REVISION LEVEL
SHEET
10
Case X - Continued
Millimeters
Min
Max
9.65
76.07
76.33
63.37
63.63
75.57
37.97
38.23
4.95
5.21
1.14
1.40
6.05
5.46
5.72
69.98
70.23
31.88
32.13
6.22
6.48
0.89
1.14
3.12
3.38
Symbol
A
D
D1
D2
E
e1
F
L
L1
q
q1
S
∅b
∅p
Inches
Min
Max
.380
3.005
2.505
2.975
1.505
.205
.055
.238
.225
2.765
1.265
.255
.045
.133
2.995
2.495
1.495
.195
.045
.215
2.755
1.255
.245
.035
.123
NOTES:
1. The U.S. government preferred system of measurement is the metric SI. This item was designed using inch-pound
units of measurement. In case of problems involving conflicts between the metric and inch-pound units, the inchpound units shall rule.
2. Lead identification for reference only.
3. Case outline weight: 92 grams maximum.
FIGURE 1. Case outline(s) - Continued.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-99609
A
REVISION LEVEL
SHEET
11
Case Y
FIGURE 1. Case outline(s) – Continued.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-99609
A
REVISION LEVEL
SHEET
12
Case Y - Continued
Millimeters
Min
Max
9.65
75.57
63.37
63.63
37.97
38.23
50.6
51.1
4.95
5.21
1.14
1.40
6.05
5.46
5.72
44.32
44.58
29.08
29.34
44.32
44.58
6.1
6.6
7.49
7.75
9.40
9.65
6.22
6.48
0.89
1.14
3.43
3.68
Symbol
A
D
D1
E
e1
e2
F
L
L1
q
q1
q2
q3
q4
q5
S
∅b
∅p
Inches
Min
Max
.380
2.975
2.505
1.505
2.01
.205
.055
.238
.225
1.755
1.155
1.755
.26
.305
.380
.255
.045
.145
2.495
1.495
1.99
.195
.045
.215
1.745
1.145
1.745
.24
.295
.370
.245
.035
.135
NOTES:
1. The U.S. government preferred system of measurement is the metric SI. This item was designed using inch-pound
units of measurement. In case of problems involving conflicts between the metric and inch-pound units, the inchpound units shall rule.
2. Lead identification for reference only.
3. Case outline weight: 92 grams maximum.
FIGURE 1. Case outline(s) - Continued.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-99609
A
REVISION LEVEL
SHEET
13
Case Z
FIGURE 1. Case outline(s) - Continued.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-99609
A
REVISION LEVEL
SHEET
14
Case Z - Continued
Millimeters
Min
Max
9.65
71.00
71.25
63.37
63.63
13.21
13.46
37.97
38.23
50.6
51.1
25.27
25.53
1.14
1.40
8.9
9.4
5.46
5.72
44.32
44.58
29.08
29.34
44.32
44.58
6.1
6.6
7.49
7.75
9.40
9.65
6.22
6.48
0.89
1.14
3.43
3.68
Symbol
A
D
D1
D2
E
e1
e2
F
L
L1
q
q1
q2
q3
q4
q5
S
∅b
∅p
Inches
Min
Max
.380
2.805
2.505
.530
1.505
2.01
1.005
.055
.37
.225
1.755
1.155
1.755
.26
.305
.380
.255
.045
.145
2.795
2.495
.520
1.495
1.99
.995
.045
.35
.215
1.745
1.145
1.745
.24
.295
.370
.245
.035
.135
NOTES:
1. The U.S. government preferred system of measurement is the metric SI. This item was designed using inch-pound
units of measurement. In case of problems involving conflicts between the metric and inch-pound units, the inchpound units shall rule.
2. Lead identification for reference only.
3. Case outline weight: 92 grams maximum.
FIGURE 1. Case outline(s) - Continued.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-99609
A
REVISION LEVEL
SHEET
15
Device type
01
Case outlines
U,X,Y,Z
Terminal number
Terminal symbol
1
Positive Input
2
Input Return
3
Case
4
Enable 1
5
Sync Output
6
Sync Input
7
Positive Output
8
Output Return
9
Return Sense
10
Positive Sense
11
Share
12
Enable 2
FIGURE 2. Terminal connections.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-99609
A
REVISION LEVEL
SHEET
16
TABLE II. Electrical test requirements.
MIL-PRF-38534 test requirements
Subgroups
(in accordance with
MIL-PRF-38534, group A test
table)
Interim electrical parameters
--*
Final electrical parameters
1 , 2, 3, 4, 5, 6
Group A test requirements
1, 2, 3, 4, 5, 6
Group C end-point electrical
Parameters
1, 4
MIL-STD-883, group E end-point
electrical parameters for RHA
devices
Not applicable
* PDA applies to subgroup 1.
4.2 Screening. Screening shall be in accordance with MIL-PRF-38534. The following additional criteria shall apply:
a. Burn-in test, method 1015 of MIL-STD-883.
(1)
Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level
control and shall be made available to either DSCC-VA or the acquiring activity upon request. Also, the test circuit shall
specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in test
method 1015 of MIL-STD-883.
(2)
TA as specified in accordance with table I of method 1015 of MIL-STD-883.
b. Interim and final electrical test parameters shall be as specified in table II herein, except interim electrical parameter tests
prior to burn-in are optional at the discretion of the manufacturer.
4.3 Conformance and periodic inspections. Conformance inspection (CI) and periodic inspection (PI) shall be in accordance
with MIL-PRF-38534 and as specified herein.
4.3.1 Group A inspection (CI). Group A inspection shall be in accordance with MIL-PRF-38534 and as follows:
a. Tests shall be as specified in table II herein.
b. Subgroups 7, 8, 9, 10, and 11 shall be omitted.
4.3.2 Group B inspection (PI). Group B inspection shall be in accordance with MIL-PRF-38534.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-99609
A
REVISION LEVEL
SHEET
17
4.3.3 Group C inspection (PI). Group C inspection shall be in accordance with MIL-PRF-38534 and as follows:
a. End-point electrical parameters shall be as specified in table II herein.
b. Steady-state life test, method 1005 of MIL-STD-883.
(1)
Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level
control and shall be made available to either DSCC-VA or the acquiring activity upon request. Also, the test circuit shall
specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in test
method 1005 of MIL-STD-883.
(2)
TA as specified in accordance with table I of method 1005 of MIL-STD-883.
(3)
Test duration: 1,000 hours, except as permitted by method 1005 of MIL-STD-883.
4.3.4 Group D inspection (PI). Group D inspection shall be in accordance with MIL-PRF-38534.
4.3.5 Radiation Hardness Assurance (RHA) inspection. RHA inspection is not currently applicable to this drawing.
5. PACKAGING
5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-PRF-38534.
6. NOTES
6.1 Intended use. Microcircuits conforming to this drawing are intended for use for Government microcircuit applications (original
equipment), design applications, and logistics purposes.
6.2 Replaceability. Microcircuits covered by this drawing will replace the same generic device covered by a contractor-prepared
specification or drawing.
6.3 Configuration control of SMD's. All proposed changes to existing SMD's will be coordinated as specified in MIL-PRF-38534.
6.4 Record of users. Military and industrial users shall inform Defense Supply Center Columbus when a system application
requires configuration control and the applicable SMD. DSCC will maintain a record of users and this list will be used for
coordination and distribution of changes to the drawings. Users of drawings covering microelectronic devices (FSC 5962) should
contact DSCC-VA, telephone (614) 692-0544.
6.5 Comments. Comments on this drawing should be directed to DSCC-VA, Columbus, Ohio 43216-5000, or telephone (614)
692-0512.
6.6 Sources of supply. Sources of supply are listed in MIL-HDBK-103 and QML-38534. The vendors listed in MIL-HDBK-103
and QML-38534 have submitted a certificate of compliance (see 3.7 herein) to DSCC-VA and have agreed to this drawing.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-99609
A
REVISION LEVEL
SHEET
18
STANDARD MICROCIRCUIT DRAWING BULLETIN
DATE: 00-08-09
Approved sources of supply for SMD 5962-99609 are listed below for immediate acquisition information only and shall
be added to MIL-HDBK-103 and QML-38534 during the next revisions. MIL-HDBK-103 and QML-38534 will be revised
to include the addition or deletion of sources. The vendors listed below have agreed to this drawing and a certificate of
compliance has been submitted to and accepted by DSCC-VA. This bulletin is superseded by the next dated revisions
of MIL-HDBK-103 and QML-38534.
1/
2/
Standard
microcircuit drawing
PIN 1/
Vendor
CAGE
Number
Vendor
Similar
PIN 2/
5962-9960901HUA
5962-9960901HUC
5962-9960901HXA
5962-9960901HXC
5962-9960901HYA
5962-9960901HYC
5962-9960901HZA
5962-9960901HZC
52467
52467
52467
52467
52467
52467
52467
52467
AFL12012DW/CH
AFL12012DW/CH
AFL12012DX/CH
AFL12012DX/CH
AFL12012DY/CH
AFL12012DY/CH
AFL12012DZ/CH
AFL12012DZ/CH
The lead finish shown for each PIN representing hermetic package is the most
readily available from the manufacturer listed for that part. If the desired lead finish
is not listed contact the vendor to determine its availability.
Caution. Do not use this number for item acquisition. Items acquired to this number
may not satisfy the performance requirements of this drawing.
Vendor CAGE
number
52467
Vendor name
and address
Lambda Advanced Analog Incorporated
2270 Martin Avenue
Santa Clara, CA 95050-2781
The information contained herein is disseminated for convenience only and the
Government assumes no liability whatsoever for any inaccuracies in the
information bulletin.