REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED REV SHEET REV SHEET 15 16 17 18 REV STATUS REV OF SHEETS SHEET PMIC N/A PREPARED BY 1 2 3 4 5 Steve Duncan STANDARD MICROCIRCUIT DRAWING CHECKED BY THIS DRAWING IS AVAILABLE FOR USE BY ALL DEPARTMENTS AND AGENCIES OF THE DEPARTMENT OF DEFENSE APPROVED BY Raymond Monnin AMSC N/A 6 7 8 9 10 11 12 13 14 DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43216 Michael Jones MICROCIRCUIT, HYBRID, LINEAR, 12 VOLT, DUAL CHANNEL, DC/DC CONVERTER DRAWING APPROVAL DATE 00-08-09 REVISION LEVEL SIZE CAGE CODE A 67268 SHEET 1 OF DSCC FORM 2233 APR 97 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. 5962-99609 18 5962-E469-00 1. SCOPE 1.1 Scope. This drawing documents five product assurance classes, class D (lowest reliability), class E, (exceptions), class G (lowest high reliability), class H (high reliability), and class K, (highest reliability) and a choice of case outlines and lead finishes are available and are reflected in the Part or Identifying Number (PIN). When available, a choice of radiation hardness assurance levels are reflected in the PIN. 1.2 PIN. The PIN shall be as shown in the following example: 5962 Federal stock class designator \ 99609 RHA designator (see 1.2.1) / \/ Drawing number 01 Device type (see 1.2.2) H Device class designator (see 1.2.3) X Case outline (see 1.2.4) X Lead finish (see 1.2.5) 1.2.1 Radiation hardness assurance (RHA) designator. RHA marked devices shall meet the MIL-PRF-38534 specified RHA levels and shall be marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device. 1.2.2 Device type(s). The device type(s) identify the circuit function as follows: Device type Generic number 01 Circuit function DC/DC converter, 96 W, ±12 V output AFL12012D/CH 1.2.3 Device class designator. This device class designator shall be a single letter identifying the product assurance level as follows: Device class Device performance documentation D, E, G, H, or K Certification and qualification to MIL-PRF-38534 1.2.4 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows: Outline letter U X Y Z Descriptive designator See figure 1 See figure 1 See figure 1 See figure 1 Terminals Package style 12 12 12 12 Y case configuration with leads bent upwards Straight leads with end mounting thru holes Straight leads with side mounting thru holes Y case configuration with leads bent downwards 1.2.5 Lead finish. The lead finish shall be as specified in MIL-PRF-38534. STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43216-5000 DSCC FORM 2234 APR 97 SIZE 5962-99609 A REVISION LEVEL SHEET 2 1.3 Absolute maximum ratings. 1/ Input voltage range ................................................................................ Lead temperature (soldering, 10 seconds) ........................................... Storage temperature range ................................................................... -0.5 V dc to +180 V dc +300°C -65°C to +135°C 1.4 Recommended operating conditions. Input voltage range ................................................................................ Output power 2/ 3/ ................................................................................ Case operating temperature range........................................................ +80 V dc to +160 V dc ≤ 96 W -55°C to +125°C 2. APPLICABLE DOCUMENTS 2.1 Government specification, standards, and handbook. The following specification, standards, and handbook form a part of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the issue of the Department of Defense Index of Specifications and Standards (DoDISS) and supplement thereto, cited in the solitation. SPECIFICATION DEPARTMENT OF DEFENSE MIL-PRF-38534 - Hybrid Microcircuits, General Specification for. STANDARDS DEPARTMENT OF DEFENSE MIL-STD-883 - Test Method Standard Microcircuits. MIL-STD-1835 - Interface Standard for Microcircuit Case Outlines. HANDBOOK DEPARTMENT OF DEFENSE MIL-HDBK-103 - List of Standard Microcircuit Drawings (SMD's). MIL-HDBK-780 - Standard Microcircuit Drawings. (Unless otherwise indicated, copies of the specification, standards, and handbooks are available from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 1/ 2/ 3/ Stresses above the absolute maximum rating may cause permanent damage to the device. Extended operation at the maximum levels may degrade performance and affect reliability. Derate output power linearly above case temperature +125°C to 0 at +135°C. Output load must be distributed so that a minimum of 20% of the total output power is being provided by one of the outputs. STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43216-5000 DSCC FORM 2234 APR 97 SIZE 5962-99609 A REVISION LEVEL SHEET 3 3. REQUIREMENTS 3.1 Item requirements. The individual item performance requirements for device classes D, E, G, H, and K shall be in accordance with MIL-PRF-38534. Compliance with MIL-PRF-38534 may include the performance of all tests herein or as designated in the device manufacturer's Quality Management (QM) plan or as designated for the applicable device class. Therefore, the tests and inspections herein may not be performed for the applicable device class (see MIL-PRF-38534). Furthermore, the manufacturers may take exceptions or use alternate methods to the tests and inspections herein and not perform them. However, the performance requirements as defined in MIL-PRF-38534 shall be met for the applicable device class. 3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified in MIL-PRF-38534 and herein. 3.2.1 Case outline(s). The case outline(s) shall be in accordance with 1.2.4 herein and figure 1. 3.2.2 Terminal connections. The terminal connections shall be as specified on figure 2. 3.3 Electrical performance characteristics. Unless otherwise specified herein, the electrical performance characteristics are as specified in table I and shall apply over the full specified operating temperature range. 3.4 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table II. The electrical tests for each subgroup are defined in table I. 3.5 Marking of Device(s). Marking of device(s) shall be in accordance with MIL-PRF-38534. The device shall be marked with the PIN listed in 1.2 herein. In addition, the manufacturer's vendor similar PIN may also be marked. 3.6 Data. In addition to the general performance requirements of MIL-PRF-38534, the manufacturer of the device described herein shall maintain the electrical test data (variables format) from the initial quality conformance inspection group A lot sample, for each device type listed herein. Also, the data should include a summary of all parameters manually tested, and for those which, if any, are guaranteed. This data shall be maintained under document revision level control by the manufacturer and be made available to the preparing activity (DSCC-VA) upon request. 3.7 Certificate of compliance. A certificate of compliance shall be required from a manufacturer in order to supply to this drawing. The certificate of compliance (original copy) submitted to DSCC-VA shall affirm that the manufacturer's product meets the performance requirements of MIL-PRF-38534 and herein. 3.8 Certificate of conformance. A certificate of conformance as required in MIL-PRF-38534 shall be provided with each lot of microcircuits delivered to this drawing. 4. QUALITY ASSURANCE PROVISIONS 4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with MIL-PRF-38534 or as modified in the device manufacturer's Quality Management (QM) plan. The modification in the QM plan shall not affect the form, fit, or function as described herein. STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43216-5000 DSCC FORM 2234 APR 97 SIZE 5962-99609 A REVISION LEVEL SHEET 4 TABLE I. Electrical performance characteristics. Test Symbol Output voltage VOUT Conditions -55°C ≤ TC ≤ +125°C VIN = 120 V dc ±5%, CL = 0 unless otherwise specified Group A Subgroups IOUT = 4 A 1 Device type 01 2,3 Output current 1/ Limits Unit Min Max ±11.88 ±12.12 ±11.76 ±12.24 6.4 V IOUT VIN = 80, 120, and 160 V dc, either output 1,2,3 01 Output ripple voltage 2/ VRIP VIN = 80, 120, and 160 V dc, B.W. = 20 Hz to 10 MHz, IOUT = 4 A, both outputs 1,2,3 01 80 Line regulation 3/ VRLINE VIN = 80, 120, and 160 V dc, IOUT = 0, 2, and 4 A, both outputs 1,2,3 01 ±60 mV Load regulation 3/ VRLOAD VIN = 80, 120, and 160 V dc, IOUT = 0, 2, and 4 A, both ouputs 1,2,3 01 ±120 mV Cross regulation 4/ Positive output VRCROS VIN = 80, 120, and 160 V dc 1,2,3 01 ±120 mV mV p-p ±600 Negative output Input current A IIN IOUT = no load 1 01 20 2,3 25 Enable 1, (pin 4) shorted to Input return (pin 2) 1,2,3 3 Enable 2, (pin 12) shorted to Output return (pin 8) 1,2,3 5 Input ripple current 2/ IRIP IOUT = 4 A, B.W. = 20 Hz to 10 MHz 1,2,3 01 70 Efficiency EFF IOUT = 4 A, both outputs 1,2,3 01 82 Isolation ISO Input to output or any pin to case (except pin 3) at 500 V dc, TC =+25°C 1 01 100 Maximum capacitive Load 5/ CL No effect on dc performance, each output, TC =+25°C 4 01 10,000 mA mA p-p % MΩ µF See footnotes at end of table. STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43216-5000 DSCC FORM 2234 APR 97 SIZE 5962-99609 A REVISION LEVEL SHEET 5 TABLE I. Electrical performance characteristics - Continued. Test Symbol Conditions -55°C ≤ TC ≤ +125°C VIN = 120 V dc ±5%, CL = 0 unless otherwise specified Group A Subgroups Device type Limits Min Power dissipation load fault PD Overload 6/ 1,2,3 01 ICL Max 32 Short circuit Current limit point 7/ Unit W 32 VOUT = 90 % VNOM 1 01 4.6 5.0 2 4.2 5.0 3 4.6 5.8 A Switching frequency FS 4,5,6 01 500 600 kHz Sync frequency range FSYNC 4,5,6 01 500 700 kHz Output response to step transient load changes 8/ VOTLOAD 4,5,6 01 -750 +750 mV pk -750 +750 50% to/from 100% 10% to/from 50% Recovery time, step transient load changes 8/ 9/ TTLOAD 50% to/from 100% 4,5,6 01 200 10% to/from 50% µs 400 Output response to transient step line changes 5/ 10/ VOTLINE Input step 160 V to/from 400 V dc 4,5,6 01 Recovery time transient step line changes 5/ 8/ 10/ TTLINE Input step 160 V to/from 400 V dc 4,5,6 Turn on overshoot VTonos Enable 1 and 2 on. (Pins 4 and 12 high or open) Turn on delay 11/ TonD Enable 1 and 2 on. (Pins 4 and 12 high or open) Load fault recovery 5/ TrLF -500 +500 mV pk 01 500 µs 4,5,6 01 250 mV pk 4,5,6 01 120 ms 4,5,6 01 120 ms See footnotes at top of next page. STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43216-5000 DSCC FORM 2234 APR 97 SIZE 5962-99609 A REVISION LEVEL SHEET 6 TABLE I. Electrical performance characteristics - Continued. 1/ Parameter guaranteed by line and load regulation tests. 2/ Bandwidth guaranteed by design. Tested for 20 kHz to 10 MHz. 3/ Load current split equally between +VOUT and -VOUT. 4/ Cross regulation measured with load on tested ouput at 20% while changing the load on the other from 20% to 80%. 5/ Parameter shall be tested as part of design characterization and after design or process changes. Thereafter, parameters shall be guaranteed to the limits specified in table I. 6/ An overload is that condition with a load in excess of the rated load but less than that necessary to trigger the short circuit protection and is the condition of maximum power dissipation. 7/ Current limit point is that condition of excess load causing output voltage to drop 90% of nominal. 8/ Load step transition time ≥ 10 microseconds. 9/ Recovery time is measured from the initiation of the transient to where VOUT has returned to within ± 1 percent of VOUT at 50 percent load. 10/ Input step transition time ≥ 100 microseconds. 11/ Turn on delay is measured with an input voltage rise time of between 100 and 500 volts per millisecond. STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43216-5000 DSCC FORM 2234 APR 97 SIZE 5962-99609 A REVISION LEVEL SHEET 7 Case U FIGURE 1. Case outline(s). STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43216-5000 DSCC FORM 2234 APR 97 SIZE 5962-99609 A REVISION LEVEL SHEET 8 Case U - Continued Millimeters Min Max 9.65 71.00 71.25 63.37 63.63 13.21 13.46 37.97 38.23 50.6 51.1 25.27 25.53 1.14 1.40 10.4 10.9 5.46 5.72 44.32 44.58 29.08 29.34 44.32 44.58 6.1 6.6 7.49 7.75 9.40 9.65 6.22 6.48 0.89 1.14 3.43 3.68 Symbol A D D1 D2 E e1 e2 F L L1 q q1 q2 q3 q4 q5 S ∅b ∅p Inches Min Max .380 2.805 2.505 .530 1.505 2.01 1.005 .055 .43 .225 1.755 1.155 1.755 .26 .305 .380 .255 .045 .145 2.795 2.495 .520 1.495 1.99 .995 .045 .41 .215 1.745 1.145 1.745 .24 .295 .370 .245 .035 .135 NOTES: 1. The U.S. government preferred system of measurement is the metric SI. This item was designed using inch-pound units of measurement. In case of problems involving conflicts between the metric and inch-pound units, the inchpound units shall rule. 2. Lead identification for reference only. 3. Case outline weight: 92 grams maximum. FIGURE 1. Case outline(s) - Continued. STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43216-5000 DSCC FORM 2234 APR 97 SIZE 5962-99609 A REVISION LEVEL SHEET 9 Case X FIGURE 1. Case outline - Continued. STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43216-5000 DSCC FORM 2234 APR 97 SIZE 5962-99609 A REVISION LEVEL SHEET 10 Case X - Continued Millimeters Min Max 9.65 76.07 76.33 63.37 63.63 75.57 37.97 38.23 4.95 5.21 1.14 1.40 6.05 5.46 5.72 69.98 70.23 31.88 32.13 6.22 6.48 0.89 1.14 3.12 3.38 Symbol A D D1 D2 E e1 F L L1 q q1 S ∅b ∅p Inches Min Max .380 3.005 2.505 2.975 1.505 .205 .055 .238 .225 2.765 1.265 .255 .045 .133 2.995 2.495 1.495 .195 .045 .215 2.755 1.255 .245 .035 .123 NOTES: 1. The U.S. government preferred system of measurement is the metric SI. This item was designed using inch-pound units of measurement. In case of problems involving conflicts between the metric and inch-pound units, the inchpound units shall rule. 2. Lead identification for reference only. 3. Case outline weight: 92 grams maximum. FIGURE 1. Case outline(s) - Continued. STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43216-5000 DSCC FORM 2234 APR 97 SIZE 5962-99609 A REVISION LEVEL SHEET 11 Case Y FIGURE 1. Case outline(s) – Continued. STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43216-5000 DSCC FORM 2234 APR 97 SIZE 5962-99609 A REVISION LEVEL SHEET 12 Case Y - Continued Millimeters Min Max 9.65 75.57 63.37 63.63 37.97 38.23 50.6 51.1 4.95 5.21 1.14 1.40 6.05 5.46 5.72 44.32 44.58 29.08 29.34 44.32 44.58 6.1 6.6 7.49 7.75 9.40 9.65 6.22 6.48 0.89 1.14 3.43 3.68 Symbol A D D1 E e1 e2 F L L1 q q1 q2 q3 q4 q5 S ∅b ∅p Inches Min Max .380 2.975 2.505 1.505 2.01 .205 .055 .238 .225 1.755 1.155 1.755 .26 .305 .380 .255 .045 .145 2.495 1.495 1.99 .195 .045 .215 1.745 1.145 1.745 .24 .295 .370 .245 .035 .135 NOTES: 1. The U.S. government preferred system of measurement is the metric SI. This item was designed using inch-pound units of measurement. In case of problems involving conflicts between the metric and inch-pound units, the inchpound units shall rule. 2. Lead identification for reference only. 3. Case outline weight: 92 grams maximum. FIGURE 1. Case outline(s) - Continued. STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43216-5000 DSCC FORM 2234 APR 97 SIZE 5962-99609 A REVISION LEVEL SHEET 13 Case Z FIGURE 1. Case outline(s) - Continued. STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43216-5000 DSCC FORM 2234 APR 97 SIZE 5962-99609 A REVISION LEVEL SHEET 14 Case Z - Continued Millimeters Min Max 9.65 71.00 71.25 63.37 63.63 13.21 13.46 37.97 38.23 50.6 51.1 25.27 25.53 1.14 1.40 8.9 9.4 5.46 5.72 44.32 44.58 29.08 29.34 44.32 44.58 6.1 6.6 7.49 7.75 9.40 9.65 6.22 6.48 0.89 1.14 3.43 3.68 Symbol A D D1 D2 E e1 e2 F L L1 q q1 q2 q3 q4 q5 S ∅b ∅p Inches Min Max .380 2.805 2.505 .530 1.505 2.01 1.005 .055 .37 .225 1.755 1.155 1.755 .26 .305 .380 .255 .045 .145 2.795 2.495 .520 1.495 1.99 .995 .045 .35 .215 1.745 1.145 1.745 .24 .295 .370 .245 .035 .135 NOTES: 1. The U.S. government preferred system of measurement is the metric SI. This item was designed using inch-pound units of measurement. In case of problems involving conflicts between the metric and inch-pound units, the inchpound units shall rule. 2. Lead identification for reference only. 3. Case outline weight: 92 grams maximum. FIGURE 1. Case outline(s) - Continued. STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43216-5000 DSCC FORM 2234 APR 97 SIZE 5962-99609 A REVISION LEVEL SHEET 15 Device type 01 Case outlines U,X,Y,Z Terminal number Terminal symbol 1 Positive Input 2 Input Return 3 Case 4 Enable 1 5 Sync Output 6 Sync Input 7 Positive Output 8 Output Return 9 Return Sense 10 Positive Sense 11 Share 12 Enable 2 FIGURE 2. Terminal connections. STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43216-5000 DSCC FORM 2234 APR 97 SIZE 5962-99609 A REVISION LEVEL SHEET 16 TABLE II. Electrical test requirements. MIL-PRF-38534 test requirements Subgroups (in accordance with MIL-PRF-38534, group A test table) Interim electrical parameters --* Final electrical parameters 1 , 2, 3, 4, 5, 6 Group A test requirements 1, 2, 3, 4, 5, 6 Group C end-point electrical Parameters 1, 4 MIL-STD-883, group E end-point electrical parameters for RHA devices Not applicable * PDA applies to subgroup 1. 4.2 Screening. Screening shall be in accordance with MIL-PRF-38534. The following additional criteria shall apply: a. Burn-in test, method 1015 of MIL-STD-883. (1) Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level control and shall be made available to either DSCC-VA or the acquiring activity upon request. Also, the test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in test method 1015 of MIL-STD-883. (2) TA as specified in accordance with table I of method 1015 of MIL-STD-883. b. Interim and final electrical test parameters shall be as specified in table II herein, except interim electrical parameter tests prior to burn-in are optional at the discretion of the manufacturer. 4.3 Conformance and periodic inspections. Conformance inspection (CI) and periodic inspection (PI) shall be in accordance with MIL-PRF-38534 and as specified herein. 4.3.1 Group A inspection (CI). Group A inspection shall be in accordance with MIL-PRF-38534 and as follows: a. Tests shall be as specified in table II herein. b. Subgroups 7, 8, 9, 10, and 11 shall be omitted. 4.3.2 Group B inspection (PI). Group B inspection shall be in accordance with MIL-PRF-38534. STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43216-5000 DSCC FORM 2234 APR 97 SIZE 5962-99609 A REVISION LEVEL SHEET 17 4.3.3 Group C inspection (PI). Group C inspection shall be in accordance with MIL-PRF-38534 and as follows: a. End-point electrical parameters shall be as specified in table II herein. b. Steady-state life test, method 1005 of MIL-STD-883. (1) Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level control and shall be made available to either DSCC-VA or the acquiring activity upon request. Also, the test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in test method 1005 of MIL-STD-883. (2) TA as specified in accordance with table I of method 1005 of MIL-STD-883. (3) Test duration: 1,000 hours, except as permitted by method 1005 of MIL-STD-883. 4.3.4 Group D inspection (PI). Group D inspection shall be in accordance with MIL-PRF-38534. 4.3.5 Radiation Hardness Assurance (RHA) inspection. RHA inspection is not currently applicable to this drawing. 5. PACKAGING 5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-PRF-38534. 6. NOTES 6.1 Intended use. Microcircuits conforming to this drawing are intended for use for Government microcircuit applications (original equipment), design applications, and logistics purposes. 6.2 Replaceability. Microcircuits covered by this drawing will replace the same generic device covered by a contractor-prepared specification or drawing. 6.3 Configuration control of SMD's. All proposed changes to existing SMD's will be coordinated as specified in MIL-PRF-38534. 6.4 Record of users. Military and industrial users shall inform Defense Supply Center Columbus when a system application requires configuration control and the applicable SMD. DSCC will maintain a record of users and this list will be used for coordination and distribution of changes to the drawings. Users of drawings covering microelectronic devices (FSC 5962) should contact DSCC-VA, telephone (614) 692-0544. 6.5 Comments. Comments on this drawing should be directed to DSCC-VA, Columbus, Ohio 43216-5000, or telephone (614) 692-0512. 6.6 Sources of supply. Sources of supply are listed in MIL-HDBK-103 and QML-38534. The vendors listed in MIL-HDBK-103 and QML-38534 have submitted a certificate of compliance (see 3.7 herein) to DSCC-VA and have agreed to this drawing. STANDARD MICROCIRCUIT DRAWING DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43216-5000 DSCC FORM 2234 APR 97 SIZE 5962-99609 A REVISION LEVEL SHEET 18 STANDARD MICROCIRCUIT DRAWING BULLETIN DATE: 00-08-09 Approved sources of supply for SMD 5962-99609 are listed below for immediate acquisition information only and shall be added to MIL-HDBK-103 and QML-38534 during the next revisions. MIL-HDBK-103 and QML-38534 will be revised to include the addition or deletion of sources. The vendors listed below have agreed to this drawing and a certificate of compliance has been submitted to and accepted by DSCC-VA. This bulletin is superseded by the next dated revisions of MIL-HDBK-103 and QML-38534. 1/ 2/ Standard microcircuit drawing PIN 1/ Vendor CAGE Number Vendor Similar PIN 2/ 5962-9960901HUA 5962-9960901HUC 5962-9960901HXA 5962-9960901HXC 5962-9960901HYA 5962-9960901HYC 5962-9960901HZA 5962-9960901HZC 52467 52467 52467 52467 52467 52467 52467 52467 AFL12012DW/CH AFL12012DW/CH AFL12012DX/CH AFL12012DX/CH AFL12012DY/CH AFL12012DY/CH AFL12012DZ/CH AFL12012DZ/CH The lead finish shown for each PIN representing hermetic package is the most readily available from the manufacturer listed for that part. If the desired lead finish is not listed contact the vendor to determine its availability. Caution. Do not use this number for item acquisition. Items acquired to this number may not satisfy the performance requirements of this drawing. Vendor CAGE number 52467 Vendor name and address Lambda Advanced Analog Incorporated 2270 Martin Avenue Santa Clara, CA 95050-2781 The information contained herein is disseminated for convenience only and the Government assumes no liability whatsoever for any inaccuracies in the information bulletin.