NFM-10 series 10W Output Switching Power Supply MODEL:NFM-10-5 OUTPUT FUNCTION TEST NO 1 TEST ITEM SPECIFICATION TEST CONDITION RIPPLE & NOISE V1: 150 I/P: 230VAC mVp-p (Max ) RESULT VERDICT V1: 18 mVp-p (Max ) O/P:FULL LOAD P Ta:25℃ 2 OUTPUT VOLTAGE CH1: 4.5V~ 5.5 V ADJUST RANGE I/P: 230 VAC 4.381 V~ 6.211 V/ 230 VAC I/P: 115 VAC 4.381 V~ 6.216 V/ 115 VAC V1: 0.12 %~ -0.12 P O/P:MIN LOAD Ta:25℃ 3 OUTPUT VOLTAGE V1: 2 %~ -2 % (Max) I/P:115 VAC / 264 VAC O/P:FULL/ MIN TOLERANCE % LOAD P Ta:25℃ 4 LINE REGULATION V1: 1 %~ -1 % (Max) I/P:115 VAC ~ 264 VAC V1: 0.12 %~ -0.12 % O/P:FULL LOAD P Ta:25℃ 5 LOAD REGULATION V1: 1 %~ -1 % (Max) I/P: 230 VAC V1: 0.12 %~ -0.12 % O/P:FULL ~MIN LOAD P Ta:25℃ 6 SET UP TIME 230VAC: 1800 ms (Max) I/P: 230 VAC 230VAC/ 720 ms 115 VAC: 1800 ms (Max) I/P: 115 VAC 115VAC/ 711 ms O/P:FULL LOAD P Ta:25℃ 7 RISE TIME 230VAC: 20 115VAC: 20 ms (Max) I/P: 230 VAC 230VAC/ 4.3 ms ms (Max) I/P: 115 VAC 115VAC/ 4.8 ms O/P:FULL LOAD P Ta:25℃ 8 HOLD UP TIME 230VAC: 100 ms (TYP) I/P: 230 VAC 230VAC/ 136 ms 115VAC: 24 ms (TYP) I/P: 115 VAC 115VAC/ 27 ms TEST: <5 % O/P:FULL LOAD P Ta:25℃ 9 OVER/UNDERSHOOT I/P: 230 VAC < +5% O/P:FULL LOAD TEST P Ta:25℃ 10 DYNAMIC LOAD V1: 1000 mVp-p I/P: 230 VAC 351 mVp-p O/P:FULL /Min LOAD P 90%DUTY/1KHZ Ta:25℃ Model: NFM-10-5 Test Report 1 / 5 NFM-10 series 10W Output Switching Power Supply INPUT FUNCTION TEST NO 1 TEST ITEM SPECIFICATION TEST CONDITION INPUT VOLTAGE RANGE 85VAC~264 VAC I/P:TESTING RESULT VERDICT 76V~264V O/P:FULL LOAD Ta:25℃ I/P: TEST: OK LOW-LINE-3V= 82 V P HIGH-LINE+15%=300 V O/P:FULL/MIN LOAD ON: 30 Sec . OFF: 30 Sec 10MIN ( AC POWER ON/OFF NO DAMAGE ) 2 INPUT FREQUENCY RANGE 47HZ ~440 HZ I/P: 85 VAC ~ 264 VAC NO DAMAGE OSC O/P:FULL~MIN LOAD TEST: OK P Ta:25℃ 3 EFFICIENCY I/P: 230 VAC 78 % (TYP) 78.3% O/P:FULL LOAD P Ta:25℃ 4 INPUT CURRENT 230V/ 0.15 A (TYP) I/P: 230 VAC I= 0.11 A/ 230 VAC 115V/ 0.25 A (TYP) I/P: 115 VAC I= 0.2 A/ 115 VAC P O/P:FULL LOAD Ta:25℃ 5 6 INRUSH CURRENT LEAKAGE CURRENT 230V/ 45 A (TYP) I/P: 230 VAC I= 33 A/ 230 VAC 115V/ 25 A(TYP) I/P: 115 VAC I= 17 A/ 115 VAC COLD START O/P:FULL LOAD <80uA /264 VAC I/P: 264 VAC L-V+ : 69 uA for touch leakage current O/P:Min LOAD Ta:25℃ L-V-: 69 uA N-V+: 69 uA N-V-: 69 uA P Ta:25℃ P PROTECTION FUNCTION TEST NO 1 TEST ITEM SPECIFICATION TEST CONDITION OVER LOAD PROTECTION Above 105 % I/P: 230 VAC I/P: 115 VAC O/P:TESTING RESULT VERDICT 134%/ 230 VAC 125%/ 115 VAC P Hiccup Mode Ta:25℃ 2 OVER VOLTAGE PROTECTION CH1: 5.75V~ 6.75V O/P:DC SOURSE Ta:25℃ 3 OVER TEMPERATURE PROTECTION SPEC: I/P: 230 VAC Tj 140℃ typically (U1) Detect on O/P:FULL LOAD main control IC 6.2V/ 100mA Shut off P O.T.P. Active Shut down o/p voltage,recovers automatically after temperature P goes down 4 SHORT PROTECTION SHORT EVERY OUTPUT I/P: 264 VAC NO DAMAGE 1 HOUR NO DAMAGE O/P:FULL LOAD Hiccup Mode P Ta:25℃ Model: NFM-10-5 Test Report 2 / 5 NFM-10 series 10W Output Switching Power Supply CONTROL FUNCTION TEST NO 1 TEST ITEM No load power consumption SPECIFICATION TEST CONDITION RESULT I/P: 240 VAC <0.5W VERDICT 0.3W/ 240 VAC P O/P:NO LOAD0 ENVIRONMENT TEST NO 1 TEST ITEM SPECIFICATION TEMPERATURE RISE TEST MODEL:NFM-10-5 TEST CONDITION RESULT VERDICT 1. ROOM AMBIENT BURN-IN:62 HRS I/P: 230VAC O/P: FULL LOAD Ta= 22.2℃ 2. HIGH AMBIENT BURN-IN:2 HRS I/P: 230VAC O/P: FULL LOAD Ta= 51.7℃ Position P/N 1 U1 FSQ0370RNA 2 T1 COIL 59.6℃ 84.9℃ C36 TF-1393 47U/50V RUB 105℃ YXF 46.8℃ 75.1℃ 4 D1 BYV26C 1A/600V 66.2℃ 95.4℃ 5 ZD1 P6KE200A 71.1℃ 100.6℃ 3 Ta= 51.7 ℃ 97.5℃ BD1 KBP208G 2A/800V 49.7℃ 80.0℃ 7 D100 SB1040FCT 10A/40V PEC 33U/400V NIC 105℃ PT 70.5℃ 96.7℃ 45.3℃ 73.7℃ DR007D 470U/16V NCC 105℃ KY 47.4℃ 74.8℃ 52.5℃ 78.9℃ LF-501 46.6℃ 74.5℃ 9 10 11 OVER LOAD BURN-IN TEST Ta= 22.2 ℃ 68.6℃ 6 C5 8 2 ROOM AMBIENT HIGH AMBIENT NO L100 C105 LF1 NO DAMAGE I/P: 230 VAC 1 HOUR ( MIN ) O/P: 135﹪LOAD P TEST:OK P Ta:25℃ 3 LOW TEMPERATURE TURN ON AFTER 2 HOUR I/P: 230 VAC TEST:OK O/P: 100﹪LOAD TURN ON TEST P Ta= -20℃ 4 5 HIGH HUMIDITY AFTER 12 HOURS I/P: 272 VAC HIGH TEMPERATURE IN CHAMBER ON O/P:FULL LOAD HIGH VOLTAGE CONTROL 50℃ Ta= 50℃ TURN ON TEST NO DAMAGE HUMIDITY= 95 %R.H I/P: 230 VAC TEMPERATURE + 0.03 %(0~50℃) VIBRATION TEST P + 0.01 %(0~50℃) P O/P:FULL LOAD COEFFICIENT 6 TEST:OK 1 Carton & 1 Set (1) Waveform: Sine Wave TEST:OK (2) Frequency:10~500Hz (3) Sweep Time:10min/sweep cycle P (4) Acceleration:2G (5) Test Time:1 hour in each axis (X.Y.Z) (6) Ta:25℃ Model: NFM-10-5 Test Report 3 / 5 NFM-10 series 10W Output Switching Power Supply SAFETY TEST NO 1 TEST ITEM SPECIFICATION TEST CONDITION RESULT WITHSTAND VOLTAGE I/P-O/P: 4 KVAC/min I/P-O/P: 4.4 KVAC/min I/P-O/P: VERDICT 0.787 mA Ta:25℃ P NO DAMAGE 2 ISOLATION RESISTANCE I/P-O/P:500VDC>100MΩ I/P-O/P: 500 VDC I/P-O/P: 30 GΩ Ta:25℃ P NO DAMAGE 3 APPROVAL TUV: Certificate NO :TA 50080232 P UL: File NO :E227340 E.M.C TEST NO 1 TEST ITEM HARMONIC SPECIFICATION TEST CONDITION RESULT EN61000-3-2 I/P: 230 VAC/50HZ PASS CLASS A O/P:FULL LOAD VERDICT P Ta:25℃ 2 CONDUCTION EN55022 EN55011 I/P: 230 VAC (50HZ) PASS CLASS B O/P:FULL/50% LOAD Test by certified Lab P Ta:25℃ 3 RADIATION EN55022 EN55011 I/P: 230 VAC (50HZ) PASS CLASS B O/P:FULL LOAD Test by certified Lab P Ta:25℃ 4 5 6 7 E.S.D E.F.T SURGE EN61000-4-2 I/P: 230 VAC/50HZ MEDICAL AIR:8KV / Contact:6KV O/P:FULL LOAD EN61000-4-4 I/P: 230 VAC/50HZ MEDICAL INPUT: 2KV O/P:FULL LOAD IEC61000-4-5 I/P: 230 VAC/50HZ MEDICAL L-N :2KV O/P:FULL LOAD CRITERIA A P Ta:25℃ CRITERIA A P Ta:25℃ CRITERIA A P Ta:25℃ Test by certified Lab & Test Report Prepare M.T.B.F & LIFE CYCLE CALCULATION NO 1 2 TEST ITEM SPECIFICATION CAPACITOR NFM-10-5:SUPPOSE C105 LIFE CYCLE I/P: 230VAC O/P:FULL LOAD Ta= 25 ℃ LIFE TIME= 233859 HRS I/P: 230VAC O/P:FULL LOAD Ta= 50 ℃ LIFE TIME= 51263 HRS MTBF TEST CONDITION RESULT VERDICT IS THE MOST CRITICAL COMPONENT P MIL-HDBK-217F NOTICES2 PARTS COUNT TOTAL FAILURE RATE: 723.2KHRS P Model: NFM-10-5 Test Report 4 / 5 NFM-10 series 10W Output Switching Power Supply COMPONENT STRESS TEST NO 1 TEST ITEM SPECIFICATION TEST CONDITION RESULT Power Transistor U1 Rated FSQ0370RNA: 700 V I/P:High-Line +3V = 267 V (1) 618 V O/P: (1)Full Load Turn on (2) 616 V (3) 616 V I/P:High-Line +3V = 267 V (1) 28 V O/P: (1)Full Load Turn on (2) 28 V (3) 31 V ( D to S) or (C to E) Peak Voltage (2) Full Load VERDICT P (3)Output Short Ta:25℃ 2 Diode Peak Voltage D100 Rated SF10SC4 : 40V 10A (2) Full Load P (3)Output Short Ta:25℃ 3 Clamp Diode Peak Voltage D1 Rated BYV26C : 600V 1A I/P:High-Line +3V = 267 V (1) 572 V O/P: (1)Full Load (2) 566 V (2) Dynamic Load P 90%Duty/1KHz Ta:25℃ 4 Input Capacitor Voltage C5 Rated :33u / 400V/ 105℃ I/P:High-Line +3V = 267 V (1) 388 V O/P: (1)Full Load Turn on /Off (2) 384 V (2) Min load Turn on /Off (3) 388 V (3)Full Load /Min load Change (4) 388 V I/P:High-Line +3V = 267 V (1) 11.235 V O/P: (1)Full Load Turn on /Off (2) 9.569 V (3) 9.595 V P (4)Burn in 1hour Ta:25℃ 5 Control IC Voltage Test U1 Rated FSQ0370RNA:9V~20V (2) Min load Turn on /Off P (3)Full Load /Min load Change Ta:25℃ DATE SAMPLE TEST RESULT TESTER APPROVAL 2005/11/30 RD SAMPLE PASS VINCENT TSENG MAX LIN PASS VINCENT TSENG MAX LIN PASS VINCENT TSENG MAX LIN PASS SANFORD SU VINCENT TSENG 2006/3/1 2006/6/8 2009/4/10 PRODUCT SAMPLE W0601C04 PRODUCT SAMPLE W0605B09 PRODUCT SAMPLE W0902A06 2003/12/12 Model: NFM-10-5 A50-F023 Test Report 5 / 5