SHARP LQ0DDB0004

} PREPARED BY :
DATE
1
1 SPEC No.
FILE No.
ISSUE :
PAGE: 7
SHARF=
TFT LIQUID CRYSTAL DISPLAY GROUP
SHARP CORPORATION
CDCPTCTPATTnhl
LCY-99050
April.
pages
19. 1999
APPLICABLE GROUP
TFT LIQUID CRYSTAL DISPLAY
GROUP
DEVICE SPECIFICATION FOR
LAMP UNIT
MODEL No. L Q 0
DD B 0 0 0 4
:
0 CUSTOMER'S APPROVAL
DATA
DEPARTMENTGENERALMANAGER
DEVELOPMENTENGINEERING DEPT.11
TFT DIVISION I
TFT LIQUID CRYSTAL DISPLAY GROUP
SHARP CORPORATION
I
SHARI=
LCY99050-
> These specification
(SHARP)
sheets are the proprietary
product of SHARP
and include materials protected under copyright
CORPORATION
of SHARP.
Do not
reproduce or cause any third party to reproduce them in any form or by any means,
electronic or mechanical,
written permission
for any purpose, in whole or in part, without the express
of SHARP.
> The _--_
device listed in these specification
sheets was designed and manufactured
for use
ink A equipment.
> In case of using the device for applications
transportation
(aircraft, trains, automobiles,
various safety related equipment
consideration
that appropriate
such as control and safety equipment
etc. ), rescue and security equipment
which require higher reliability
for
and
and safety, take into
measures such as fail-safe functions and redundant
system design should be taken.
> Do not use the device for equipment
as aerospace applications,
control equipment
> SHARP
that requires an extreme level of reliability,
telecommunication
equipment(trunk
for any damage resulting born the use of the
device which does not comply with the instructions
and the precautions
specified in
sheets.
Contact and consult with a SHARP sales representative
device.
lines), nuclear power
and medical or other equipment for life support.
assumes no responsibility
these specification
such
for any questions about this
1
SHARP
LCY99050-
(1) Subject
This literature
is applied for LQODDB0004
which is the lamp unit for 21cm (8.4”) TIT-LCD
module.
(2) Introduction
This backlight
unit is a service part for 21cm TFT-LCD
module (LQO84VlDG21)
is designed to be replaceable and exactly same as originally
(3) Construction
of which backlight
installed one for above model.
and Outline
The unit is composed of cold cathode fluorescent tubes, I/O wires (including
connectors),
and lamp holders.
*
Outline drawing of lamp unit
:
See Fig. 1.
(4) Input / Output terminals
4-1) I/O terminal order
Table 1
Description
Pin No.
Symbol
i/o
1
VHIGH
i
Power supply for lamp (High voltage side)
2
NC
-
No connection
3
VLOW
i
Power supply for lamp (Low voltage side)
4-2) I/O connector
1) Installed
2) Mating
socket housing
connector
; BHR-03VS-1
; SM02(&0)B-BHS
( produced by Japan Solderless Terminal
(5) Electrical
characteristics
The characteristics
of single lamp are shown in the following table 2.
Table 2
[NotellAvailable
[Note21 Calculated
current range considering
value for reference.
light-adjustment.
)
2
SHARI=
[Note31
LCY99050-
Since lamp is consumable,
the life time written
guaranteed in this specification
above is referential
value and it is not
sheet by SHARP.
Lamp life time is defined that it applied either 1 or 2 under this condition.
(Continuous
turning on at Ta=25”C,
?3”C,ILr6mArms)
1. Brightness becomes 50% of the original value under standard condition.
2. Kick-off voltage at Ta=O”C
exceeds maximum
value, 1500 Vrms.
(6) Optical characteristics
Table 3
Parameter
Symbol
MIN.
TYP.
Luminance
YL
-
28,000
-
Chromaticity
X
0.278
0.288
0.298
Y
j 0.245
0.255
0.265
Above value is the characteristics
(7) Environmental
unit
cd/m2
Remarks
1~=6.OmA
. (Tentative
Value)
of the lamp itself with the inverter
condition
Followingfemperature
module
MAX.
ranges indicate
LQ084VlDC21
- ____------
ambient condition
to be guaranteed
by SHARP
for the LCD
which the lamp unit is incorparated.
Table 4
Item
Storage temperature
Operating
(Note11
range
temperature
Humidity:
Maximum
Symbo 1
range (Ambient)
95%RH
Max.(Ta
wet-bulb temperature
No condensation.
Unit
Tstg
Temperature
-25 -.-t70
Topa
0 _ +.55
“C
540°C)
at 39°C or less.(Ta>40”C)
3
“C
Remarks
(Note11
SHARP
LCY9905054t 10
198.620.5
Fig,. 1. Outline drawing of Lamp unit
*
4
SHARP
LCY99050-
5
(8) Procedure to exchange Lamp unit
Lamps for the LCD module can be worn out, so please replace them to new lamps when needed in
accordance
with the following.
Please make sure that power is off before you replace them to
prevent you from getting an electrical shock. Please insert the lamp with care while replacing.
Please
be careful for any dust goes in.
0
Remove 2 screws which holds the Lamp unit. (refer to Fig. 2)
@ Slide the Lamp unit to the “B”
direction.
0 Remove the Lamp unit. (“C’direction)
@ Replace the new Lamp unit to the “ D “direction and slide the unite to the “E” direction.
(refer to Fig.3)
@ Tighten the 2 screws to lix the Lamp unit along the screw gap of. hole. The screw torque
should
be maximum
1.6kgf * cm. If you tighten the screw over 1.6kgf.cm, the screw should
be destroyed.
Please be careful.
@ Please insert the lamp with care while replacing. Please be careful for any dust that goes in.
Please make sure that the lamp unit is in all the way.
w
Fig. 2.
Procedure to exchange Lamp unit.
LCY99050-
Fig. 3.
Procedure to exchange Lamp unit
6
SHARF=
LCY99050-
(9) Packing form
Packing form is shown in Fig.4 (Total Weight: 2,860 g)
(10) Others
10-l) It shaII be informed before with attachment
design, process, or management
of the Quality/
reliability
data if any changes of
system occurs.
10-2) If any problems occurs in relation to the description in the present specitications
relevant items, it shall be eliminated
in all sincerity through discussion.
Fig.4.Packing
form
or other
7