VISHAY KBU8M

KBU8A THRU KBU8M
SINGLE-PHASE BRIDGE RECTIFIER
Reverse Voltage - 50 to 1000 Volts
Forward Current - 8.0 Amperes
FEATURES
Case Style KBU
0.935 (23.7)
0.160 (4.1)
0.140 (3.6)
0.895 (22.7)
0.185 (4.7)
0.165 (4.2)
45o
0.760
(19.3)
MAX.
0.085 (2.2)
0.065 (1.7)
0.700
(17.8)
0.660
(16.8)
0.075 (1.9) R. TYP.
(2 PLACES)
0.455 (11.3)
0.405 (10.3)
1.0
(25.4)
MIN.
0.052 (1.3)
0.048 (1.2)
DIA.
0.220 (5.6)
0.180 (4.6)
0.240 (6.09)
0.200 (5.08)
0.280 (7.1)
0.260 (6.6)
0.205 (5.2)
0.185 (4.7)
Dimensions in inches and (millimeters)
♦ Plastic material used carries Underwriters Laboratory
Flammability Classification 94V-0
♦ This series is UL listed under Recognized Component Index,
file number E54214
♦ High case dielectric strength
of 1500 VRMS
♦ Ideal for printed circuit boards
♦ High forward surge current capability
♦ High temperature soldering guaranteed:
250°C/10 seconds, 0.375" (9.5mm) lead length,
5lbs. (2.3 kg) tension
MECHANICAL DATA
Case: Molded plastic body
Terminals: Plated leads solderable per MIL-STD-750,
Method 2026
Mounting Position: Any (NOTE 1)
Mounting Torque: 5 in.-lb. max.
Weight: 0.3 ounce, 8.0 grams
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25°C ambient temperature unless otherwise specified.
SYMBOLS
KBU
8A
KBU
8B
KBU
8D
KBU
8G
KBU
8J
KBU
8K
KBU
8M
UNITS
Maximum repetitive peak reverse voltage
VRRM
50
100
200
400
600
800
1000
Volts
Maximum RMS voltage
VRMS
35
70
140
280
420
560
700
Volts
Maximum DC blocking voltage
VDC
50
100
200
400
600
800
1000
Volts
Maximum average forward rectified TC=100°C (NOTE 1, 3)
output current at
TA=45°C (NOTE 2)
I(AV)
8.0
6.0
Amps
Peak forward surge current single half sine-wave
superimposed on rated load (JEDEC Method) TJ=150°C
IFSM
300.0
Amps
VF
1.0
Volts
IR
10.0
1.0
µA
mA
RΘJA
RΘJC
18.0
3.0
°C/W
TJ, TSTG
-50 to +150
°C
Maximum instantaneous forward voltage drop
per leg at 8.0A
Maximum DC reverse current at rated
DC blocking voltage per leg
TA=25°C
TA=125°C
Typical thermal resistance per leg (NOTE 2)
(NOTE 3)
Operating junction and storage temperature range
NOTES:
(1) Recommended mounting position is to bolt down on heatsink with silicone thermal compound for maximum heat transfer with #6 screw
(2) Units mounted in free air, no heatsink, P.C.B. at 0.375" (9.5mm) lead length with 0.5 x 0.5” (12 x 12mm) copper pads
(3) Units mounted on a 3.0 x 3.0” x 0.11" thick (7.5 x 7.5 x 0.3cm) Al. Plate heatsink
4/98
RATINGS AND CHARACTERISTICS CURVES KBU8A THRU KBU8M
FIG. 2 - MAXIMUM NON-REPETITIVE PEAK
FORWARD SURGE CURRENT
300
8.0
HEAT-SINK MOUNTING,TC
3.0 x 3.0 x 12”THK AL. PLATE
(7.5 x 0.3cm)
PEAK FORWARD SURGE CURRENT,
AMPERES
AVERAGE FORWARD CURRENT,
AMPERES
FIG. 1 - DERATING CURVE OUTPUT RECTIFIED
CURRENT
6.0
4.0
P.C.B. MOUNTING, TA
0.375” (9.5mm) LEAD LENGTH
0.5 x 0.5” (12 x 12mm) COPPER PADS
2.0
60 HZ RESISTIVE OR INDUCTIVE LOAD
0
0
50
100
150
TEMPERATURE, °C
SINGLE SINE-WAVE
(JEDEC Method)
TJ=150°C
250
200
150
100
50
0
1.0 CYCLE
1
10
100
NUMBER OF CYCLES AT 60 HZ
FIG. 4 - TYPICAL REVERSE LEAKAGE
CHARACTERISTICS PER LEG
FIG. 3 - TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS PER LEG
50
INSTANTANEOUS REVERSE CURRENT,
MICROAMPERES
INSTANTANEOUS FORWARD CURRENT,
AMPERES
100
TJ=25°C
PULSE WIDTH=300µs
1% DUTY CYCLE
10
1
0.1
0.6
0.7
0.8
0.9
1.0
1.1
1.2
1.3
10
TJ=100°C
1
0.1
TJ=25°C
INSTANTANEOUS FORWARD VOLTAGE,
VOLTS
0.01
0
20
40
60
80
PERCENT OF RATED PEAK REVERSE
VOLTAGE, %
FIG. 5 - TYPICAL JUNCTION CAPACITANCE
PER LEG
JUNCTION CAPACITANCE, pF
400
TJ=25°C
f=1.0 MHz
Vsig=50mVp-p
100
10
1
10
REVERSE VOLTAGE, VOLTS
100
100