VISHAY KBU6D

KBU6A THRU KBU6M
SINGLE-PHASE BRIDGE RECTIFIERS
Reverse Voltage - 50 to 1000 Volts
Forward Current - 6.0 Amperes
FEATURES
♦ Plastic material used carries Underwriters Laboratory
Flammability Classification 94V-0
♦ This series is UL listed under Recognized Component Index,
file number E54214
♦ High case dielectric strength
of 1500 VRMS
♦ Ideal for printed circuit boards
♦ High surge current capability
♦ High temperature soldering guaranteed:
250°C/10 seconds, 0.375" (9.5mm) lead length,
5lbs. (2.3 kg) tension
Case Style KBU
0.935 (23.7)
0.160 (4.1)
0.140 (3.6)
0.895 (22.7)
0.185 (4.7)
0.165 (4.2)
45o
0.760
(19.3)
MAX.
0.085 (2.2)
0.065 (1.7)
0.700
(17.8)
0.660
(16.8)
0.075 (1.9) R. TYP.
(2 PLACES)
0.455 (11.3)
0.405 (10.3)
1.0
(25.4)
MIN.
0.052 (1.3)
0.048 (1.2)
DIA.
0.220 (5.6)
0.180 (4.6)
MECHANICAL DATA
0.240 (6.09)
0.200 (5.08)
Case: Molded plastic body
Terminals: Plated leads solderable per MIL-STD-750,
Method 2026
Mounting Position: Any (NOTE 1)
Mounting Torque: 5 in. - lb. max.
Weight: 0.3 ounce, 8.0 grams
0.280 (7.1)
0.260 (6.6)
0.205 (5.2)
0.185 (4.7)
Dimensions in inches
and
(millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25°C ambient temperature unless otherwise specified.
SYMBOLS
KBU
6A
KBU
6B
KBU
6D
KBU
6G
KBU
6J
KBU
6K
KBU
6M
UNITS
Maximum repetitive peak reverse voltage
VRRM
50
100
200
400
600
800
1000
Volts
Maximum RMS voltage
VRMS
35
70
140
280
420
560
700
Volts
VDC
50
100
200
400
600
800
1000
Volts
Maximum DC blocking voltage
Maximum average forward rectified TC=100°C (NOTE 1, 2)
output current at
TA=40°C (NOTE 3)
I(AV)
6.0
6.0
Amps
Peak forward surge current single half sine-wave
superimposed on rated load (JEDEC Method)TJ=150°C
IFSM
250.0
Amps
Maximum instantaneous forward voltage drop
per leg at 6.0A
VF
1.0
Volts
Maximum DC reverse current
at rated DC blocking voltage per leg
IR
5.0
1.0
µA
mA
RΘJA
RΘJC
8.6
3.1
°C/W
TJ, TSTG
-50 to +150
°C
TA=25°C
TA=125°C
Typical thermal resistance per leg (NOTE 2)
Operating junction and storage temperature range
NOTES:
(1) Recommended mounted position is to bolt down on heatsink with silicone thermal compound for maximum heat transfer with #6 screw
(2) Thermal resistance from junction to ambient with units in free air, P.C.B. mounted on 0.5 x 0.5” (12 x 12mm) copper pads, 0.375" (9.5mm) lead length
(3) Thermal resistance from junction to case with units mounted on a 2.6 x 1.4 x 0.06" thick (6.5 x 3.5 x.15cm) Al. Plate
4/98
RATINGS AND CHARACTERISTICS CURVES KBU6A THRU KBU6M
FIG. 2 - MAXIMUM NON-REPETITIVE PEAK FORWARD
SURGE CURRENT PER LEG
250
6.0
HEAT-SINK
MOUNTING, TC
2.6 x 1.4 x 0.06”
(6.5 x 3.5 x 1.5cm)
AL. PLATED
4.0
2.0
0
P.C.B. MOUNTING, TA
0.375” (9.5mm) LEAD LENGTH WITH
0.5 x 0.5” (12 x 12mm)
COPPER PAD AREAS
0
50
100
150
TEMPERATURE, °C
PEAK FORWARD SURGE CURRENT,
AMPERES
AVERAGE FORWARD CURRENT,
AMPERES
FIG. 1 - DERATING CURVE OUTPUT RECTIFIED
CURRENT
SINGLE SINE-WAVE
(JEDEC Method)
TJ=150°C
225
200
175
150
125
100
1.0 CYCLE
75
10
1
100
NUMBER OF CYCLES AT 60 Hz
FIG. 4 - TYPICAL REVERSE LEAKAGE
CHARACTERISTICS
FIG. 3 - TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS PER LEG
50
INSTANTANEOUS REVERSE CURRENT,
MICROAMPERES
INSTANTANEOUS FORWARD CURRENT,
AMPERES
100
TJ=25°C
PULSE WIDTH=300µs
1% DUTY CYCLE
10
1
0.1
0.6
0.7
0.8
0.9
1.0
1.1
1.2
1.3
10
TJ=100°C
1
0.1
TJ=25°C
0.01
0
INSTANTANEOUS FORWARD VOLTAGE, VOLTS
20
40
60
80
PERCENT OF RATED PEAK REVERSE
VOLTAGE, %
FIG. 5 - TYPICAL JUNCTION CAPACITANCE
PER LEG
JUNCTION CAPACITANCE, pF
400
TJ=25°C
f=1.0 MHz
Vsig=50mVp-p
100
10
1
10
REVERSE VOLTAGE, VOLTS
100
100