ETC CA3140BT

CA3140
S E M I C O N D U C T O R
BiMOS Operational Amplifier
with MOSFET Input/Bipolar Output
April 1994
Features
Description
• MOSFET Input Stage
- Very High Input Impedance (ZIN) -1.5TΩ (Typ.)
- Very Low Input Current (Il) -10pA (Typ.) at ±15V
- Wide Common Mode Input Voltage Range
(VlCR) - Can be Swung 0.5V Below Negative
Supply Voltage Rail
- Output Swing Complements Input Common
Mode Range
The CA3140A and CA3140 are integrated circuit operational amplifiers
that combine the advantages of high voltage PMOS transistors with
high voltage bipolar transistors on a single monolithic chip. Because of
this unique combination of technologies, this device can now provide
designers, for the first time, with the special performance features of
the CA3130 CMOS operational amplifiers and the versatility of the 741
series of industry standard operational amplifiers.
• Directly Replaces Industry Type 741 in Most
Applications
Applications
• Ground-Referenced Single Supply Amplifiers in
Automobile and Portable Instrumentation
• Sample and Hold Amplifiers
• Long Duration Timers/Multivibrators
(µseconds-Minutes-Hours)
• Photocurrent Instrumentation
• Peak Detectors
The CA3140A and CA3140 BiMOS operational amplifiers feature gate
protected MOSFET (PMOS) transistors in the input circuit to provide
very high input impedance, very low input current, and high speed performance. The CA3140A and CA3140 operate at supply voltage from
4V to 36V (either single or dual supply). These operational amplifiers
are internally phase compensated to achieve stable operation in unity
gain follower operation, and additionally, have access terminal for a
supplementary external capacitor if additional frequency roll-off is
desired. Terminals are also provided for use in applications requiring
input offset voltage nulling. The use of PMOS field effect transistors in
the input stage results in common mode input voltage capability down
to 0.5V below the negative supply terminal, an important attribute for
single supply applications. The output stage uses bipolar transistors
and includes built-in protection against damage from load terminal
short circuiting to either supply rail or to ground.
• Comparators
The CA3140 Series has the same 8-lead pinout used for the “741” and
other industry standard op amps. The CA3140A and CA3140 are
intended for operation at supply voltages up to 36V (±18V).
• Interface in 5V TTL Systems and Other Low
Supply Voltage Systems
Ordering Information
• Active Filters
• All Standard Operational Amplifier Applications
• Function Generators
• Tone Controls
TEMP. RANGE
PACKAGE
CA3140AE
PART NUMBER
-55oC to +125oC
8 Lead Plastic DIP
CA3140AM
-55oC to +125oC
8 Lead SOIC
8 Pin Can, Lead Formed
CA3140AS
-55o
• Power Supplies
CA3140AT
-55oC to +125oC
8 Pin Can
• Portable Instruments
CA3140BT
-55oC to +125oC
8 Pin Can
CA3140E
-55oC
8 Lead Plastic DIP
CA3140M
-55oC to +125oC
8 Lead SOIC
CA3140M96
-55oC to +125oC
8 Lead SOIC*
CA3140T
-55oC
8 Pin Can
• Intrusion Alarm Systems
o
C to +125 C
to
to
+125oC
+125oC
* Denotes Tape and Reel
Pinouts
CA3140 (TO-5 STYLE CAN)
TOP VIEW
TAB
CA3140 (PDIP, SOIC)
TOP VIEW
STROBE
8
OFFSET
NULL
1
–
+
INV. 2
INPUT
NON-INV.
INPUT
7
3
V+
6 OUTPUT
5 OFFSET
NULL
4
V- AND CASE
OFFSET
NULL
1
INV. INPUT
2
NON-INV.
INPUT
3
V-
4
CAUTION: These devices are sensitive to electrostatic discharge. Users should follow proper I.C. Handling Procedures.
Copyright
© Harris Corporation 1993
2-123
–
+
8
STROBE
7
V+
6
OUTPUT
5
OFFSET
NULL
File Number
957.2
Specifications CA3140, CA3140A
Absolute Maximum Ratings
Operating Conditions
DC Supply Voltage (Between V+ and V- Terminals). . . . . . . . . . 36V
Differential Mode Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . 8V
DC Input Voltage . . . . . . . . . . . . . . . . . . . . . .(V+ +8V) To (V- -0.5V)
Input Terminal Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1mA
Output Short Circuit Duration* . . . . . . . . . . . . . . . . . . . . . . Indefinite
Junction Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +175oC
Junction Temperature (Plastic Package) . . . . . . . . . . . . . . . +150oC
Lead Temperature (Soldering 10 Sec.). . . . . . . . . . . . . . . . . +300oC
OperatingTemperature Range (All Types). . . . . . . . -55oC to +125oC
Storage Temperature Range (All Types). . . . . . . . . -65oC to +150oC
* Short circuit may be applied to ground or to either supply.
CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation
of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
Electrical Specifications
V+ = +15V, V- = -15V, TA = +25oC
PARAMETERS
SYMBOL
Input Offset Voltage Adjustment Resistor
TEST CONDITIONS
CA3140A
CA3140
UNITS
Typical Value of Resistor
Between Term. 4 and 5 or 4
and 1 to Adjust Max. VI0
18
4.7
kΩ
Input Resistance
RI
1.5
1.5
TΩ
Input Capacitance
CI
4
4
pF
Output Resistance
RO
60
60
Ω
Equivalent Wideband Input Noise Voltage
(See Figure 35)
eN
BW = 140kHz
RS = 1 MΩ
48
48
µV
Equivalent Input Noise Voltage (See Figure 7)
eN
f = 1kHz
40
40
nV/√Hz
12
12
nV/√Hz
f = 10 kHz
RS = 100Ω
Short Circuit Current to Opposite Supply
Source
IOM+
40
40
mA
Sink
IOM-
18
18
mA
fT
4.5
4.5
MHz
SR
9
9
V/µs
220
220
µA
Gain-Bandwidth Product, (See Figures 2 & 15)
Slew Rate, (See Figure 3)
Sink Current From Terminal 8 To Terminal 4 to Swing
Output Low
Transient Response:
RL = 2kΩ
CL = 100pF
Rise Time
tR
0.08
0.08
µs
Overshoot (See Figure 34)
OS
10
10
%
4.5
4.5
µs
1.4
1.4
µs
Settling Time at 10 VP-P, (See Figure 14)
1mV
tS
RL = 2kΩ
CL = 100pF
Voltage Follower
10mV
2-124
Specifications CA3140, CA3140A
For Equipment Design. At V+ = 15V, V- = 15V, TA = +25oC, Unless Otherwise Specified
Electrical Specifications
LIMITS
CA3140A
PARAMETERS
CA3140
SYMBOL
MIN
TYP
MAX
MIN
TYP
MAX
UNITS
Input Offset Voltage
|VIO|
-
2
5
-
5
15
mV
Input Offset Current
|IIO|
-
0.5
20
-
0.5
30
pA
II
-
10
40
-
10
50
pA
AOL
20
l00
-
20
100
-
kV/V
86
100
-
86
100
-
dB
-
32
320
-
32
320
µV/V
70
90
-
70
90
-
dB
VICR
-15
-15.5
to
+12.5
12
-15
-15.5
to
+12.5
11
V
PSRR
-
100
150
-
100
150
µV/V
76
80
-
76
80
-
dB
VOM+
+12
13
-
+12
13
-
V
VOM-
-14
-14.4
-
-14
-14.4
-
V
Supply Current (See Figure 4)
I+
-
4
6
-
4
6
mA
Device Dissipation
PD
-
120
180
-
120
180
mW
-
6
-
-
8
-
µV/oC
Input Current
Large Signal Voltage Gain (Note 1)
(See Figures 1, 15)
Common Mode Rejection Ratio
(See Figure 6)
CMRR
Common Mode Input Voltage Range
(See Figure 17)
Power-Supply Rejection Ratio,
∆VIO/∆VS (See Figure 8)
Max. Output Voltage (Note 2)
(See Figures 10, 17)
Input Offset Voltage Temp. Drift,
∆VIO/∆T
NOTES:
1. At VO = 26Vp-p, +12V, 14V and RL = 2kΩ.
2. At RL = 2kΩ.
Electrical Specifications
For Design Guidance. At V+ = 5 V, V- = 0V, TA = +25oC
PARAMETERS
SYMBOL
CA3140A
CA3140
UNITS
Input Offset Voltage
|VIO|
2
5
mV
Input Offset Current
|IIO|
0.1
0.1
pA
Input Current
II
2
2
pA
Input Resistance
RI
1
1
TΩ
AOL
100
100
kV/V
100
100
dB
Large Signal Voltage Gain
(See Figures 1, 15)
2-125
Specifications CA3140, CA3140A
Electrical Specifications
For Design Guidance. At V+ = 5 V, V- = 0V, TA = +25oC (Continued)
PARAMETERS
SYMBOL
CA3140A
CA3140
UNITS
CMRR
32
32
µV/V
90
90
dB
-0.5
-0.5
V
2.6
2.6
V
100
100
µV/V
80
80
dB
VOM+
3
3
V
VOM-
0.13
0.13
V
Source
IOM+
10
10
mA
Sink
IOM-
1
1
mA
SR
7
7
V/µs
Gain-Bandwidth Product (See Figure 2)
fT
3.7
3.7
MHz
Supply Current (See Figure 4)
I+
1.6
1.6
mA
Device Dissipation
PD
8
8
mW
200
200
µA
Common Mode Rejection Ratio,
Common Mode Input Voltage Range (See Figure 17)
Power Supply Rejection Ratio
VICR
PSRR
∆VI0/∆VS
Maximum Output Voltage (See Figures 10, 17)
Maximum Output Current:
Slew Rate (See Figure 3)
Sink Current from Term. 8 to Term. 4 to Swing Output Low
2-126
CA3140A, CA3140
Block Diagram
2mA
4mA
7 V+
BIAS CIRCUIT
CURRENT SOURCES
AND REGULATOR
200µA
+
3
1.6mA
2µA
A≈
10,000
A ≈ 10
INPUT
2
200µA
2mA
A≈1
6 OUTPUT
C1
12pF
5
1
4 V8
STROBE
OFFSET
NULL
Schematic Diagram
BIAS CIRCUIT
INPUT STAGE
SECOND STAGE
OUTPUT STAGE
DYNAMIC CURRENT SINK
7 V+
C1
D7
Q1
Q6
Q2
Q3
Q5
Q4
Q20
R9
50Ω
D8
R10
1k
Q19 R11
20Ω
Q7
R1
8k
R13
5k
R12
12k
Q21
Q17
R8
1k
Q8
R14
20k
Q18
6 OUTPUT
D2
D3
D4
D5
INVERTING
INPUT
2
NON-INVERTING
INPUT
3
+
Q9
Q10
C1
R2
500Ω
R3
500Ω
12pF
Q15
Q14
Q11
R4
500Ω
Q12
D6
R5
500Ω
5
R6
50Ω
1
OFFSET NULL
Q16
Q13
R7
30Ω
8
4
STROBE
V-
ALL RESISTANCE VALUES ARE IN Ω
2-127
CA3140A, CA3140
Circuit Description
As shown in the block diagram, the input terminals may be
operated down to 0.5V below the negative supply rail. Two
class A amplifier stages provide the voltage gain, and a
unique class AB amplifier stage provides the current gain
necessary to drive low-impedance loads.
A biasing circuit provides control of cascoded constant
current flow circuits in the first and second stages. The
CA3140 includes an on chip phase compensating capacitor
that is sufficient for the unity gain voltage follower
configuration.
Input Stages
The schematic diagram consists of a differential input stage
using PMOS field-effect transistors (Q9, Q10) working into a
mirror pair of bipolar transistors (Q11, Q12) functioning as
load resistors together with resistors R2 through R5. The
mirror pair transistors also function as a differential-to-singleended converter to provide base current drive to the second
stage bipolar transistor (Q13). Offset nulling, when desired,
can be effected with a 10kΩ potentiometer connected across
terminals 1 and 5 and with its slider arm connected to
terminal 4. Cascode connected bipolar transistors Q2, Q5
are the constant current source for the input stage. The base
biasing circuit for the constant current source is described
subsequently. The small diodes D3, D4, D5 provide gate
oxide protection against high voltage transients, e.g., static
electricity.
Second Stage
Most of the voltage gain in the CA3140 is provided by the
second amplifier stage, consisting of bipolar transistor Q13
and its cascode connected load resistance provided by
bipolar transistors Q3, Q4. On-chip phase compensation,
sufficient for a majority of the applications is provided by C1.
Additional Miller-Effect compensation (roll off) can be
accomplished, when desired, by simply connecting a small
capacitor between terminals 1 and 8. Terminal 8 is also used
to strobe the output stage into quiescence. When terminal 8
is tied to the negative supply rail (terminal 4) by mechanical
or electrical means, the output terminal 6 swings low, i.e.,
approximately to terminal 4 potential.
Output Stage
The CA3140 Series circuits employ a broad band output
stage that can sink loads to the negative supply to
complement the capability of the PMOS input stage when
operating near the negative rail. Quiescent current in the
emitter-follower cascade circuit (Q17, Q18) is established by
transistors (Q14, Q15) whose base currents are “mirrored” to
current flowing through diode D2 in the bias circuit section.
When the CA3140 is operating such that output terminal 6 is
sourcing current, transistor Q18 functions as an emitterfollower to source current from the V+ bus (terminal 7), via
D7, R9, and R11. Under these conditions, the collector
potential of Q13 is sufficiently high to permit the necessary
flow of base current to emitter follower Q17 which, in turn,
drives Q18.
When the CA3140 is operating such that output terminal 6 is
sinking current to the V- bus, transistor Q16 is the current
sinking element. Transistor Q16 is mirror connected to D6,
R7, with current fed by way of Q21, R12, and Q20. Transistor
Q20, in turn, is biased by current flow through R13, zener
D8, and R14. The dynamic current sink is controlled by
voltage level sensing. For purposes of explanation, it is
assumed that output terminal 6 is quiescently established at
the potential midpoint between the V+ and V- supply rails.
When output current sinking mode operation is required, the
collector potential of transistor Q13 is driven below its
quiescent level, thereby causing Q17, Q18 to decrease the
output voltage at terminal 6. Thus, the gate terminal of
PMOS transistor Q21 is displaced toward the V- bus, thereby
reducing the channel resistance of Q21. As a consequence,
there is an incremental increase in current flow through Q20,
R12, Q21, D6, R7, and the base of Q16. As a result, Q16
sinks current from terminal 6 in direct response to the
incremental change in output voltage caused by Q18. This
sink current flows regardless of load; any excess current is
internally supplied by the emitter-follower Q18. Short circuit
protection of the output circuit is provided by Q19, which is
driven into conduction by the high voltage drop developed
across R11 under output short circuit conditions. Under
these conditions, the collector of Q19 diverts current from
Q4 so as to reduce the base current drive from Q17, thereby
limiting current flow in Q18 to the short circuited load
terminal.
Bias Circuit
Quiescent current in all stages (except the dynamic current
sink) of the CA3140 is dependent upon bias current flow in
R1. The function of the bias circuit is to establish and
maintain constant current flow through D1, Q6, Q8 and D2.
D1 is a diode connected transistor mirror connected in
parallel with the base emitter junctions of Q1, Q2, and Q3.
D1 may be considered as a current sampling diode that
senses the emitter current of Q6 and automatically adjusts
the base current of Q6 (via Q1) to maintain a constant
current through Q6, Q8, D2. The base currents in Q2, Q3
are also determined by constant current flow D1.
Furthermore, current in diode connected transistor Q2
establishes the currents in transistors Q14 and Q15.
2-128
CA3140, CA3140A
Metallization Mask Layout
0
10
20
30
40
50
60
65
61 60
50
40
58-66
(1.473-1.676)
30
20
10
0
4-10
(0.102-0.254)
62-70
(1.575-1.778)
Dimensions in parenthesis are in millimeters and are derived
from the basic inch dimensions as indicated. Grid graduations
are in mils (10-3 inch).
The photographs and dimensions represent a chip when it is
part of the wafer. When the wafer is cut into chips, the cleavage
angles are 57o instead of 90ο with respect to the face of the
chip. Therefore, the isolated chip is actually 7 mils (0.17mm)
larger in both dimensions.
Typical Performance Curves
20
GAIN BANDWIDTH PRODUCT (MHz)
OPEN-LOOP VOLTAGE GAIN (dB)
RL = 2kΩ
TA = -55oC
+25oC
125
+125oC
100
75
50
25
0
0
5
10
15
SUPPLY VOLTAGE (V)
20
25
FIGURE 1. OPEN LOOP VOLTAGE GAIN vs SUPPLY
VOLTAGE AND TEMPERATURE
RL = 2kΩ
CL = 100pF
10
8
+25oC
6
+125oC
TA = -55oC
5
4
3
2
1
0
5
10
15
SUPPLY VOLTAGE (V)
20
FIGURE 2. GAIN BANDWIDTH PRODUCT vs SUPPLY
VOLTAGE AND TEMPERATURE
2-129
25
CA3140, CA3140A
Typical Performance Curves (Continued)
RL = ∞
QUIESCENT SUPPLY CURRENT (mA)
SLEW RATE (V/µs)
RL = 2kΩ
CL = 100pF
+25oC
+125oC
TA = -55oC
20
15
10
5
0
0
5
10
15
SUPPLY VOLTAGE (V)
FIGURE 3. SLEW RATE vs SUPPLY VOLTAGE AND
TEMPERATURE
COMMON-MODE REJECTION RATIO (dB)
OUTPUT SWING (VP-P)
25
20
15
10
5
2
4
10K
6
8
2
4
6
100K
FREQUENCY (Hz)
8
+25oC
4
3
2
1
4M
POWER SUPPLY REJECTION RATIO (dB)
EQUIVALENT INPUT NOISE VOLTAGE (nV√Hz)
100
8
6
4
2
10
8
6
4
2
101
102
103
FREQUENCY (Hz)
20
25
100
80
CA3140B
60
CA3140, CA3140A
40
20
102
103
104
105
106
107
FIGURE 6. COMMON MODE REJECTION RATIO vs FREQUENCY
2
1
10
15
SUPPLY VOLTAGE (V)
FREQUENCY (Hz)
SUPPLY VOLTAGE: V+ = 15V, V- = -15V
TA = +25oC
1
5
120 SUPPLY VOLTAGE: V+ = 15V, V- = -15V
TA = +25oC
1000
4
0
0
101
2
1M
FIGURE 5. MAXIMUM OUTPUT VOLTAGE SWING vs
FREQUENCY
8
6
+125oC
5
FIGURE 4. QUIESCENT SUPPLY CURRENT vs SUPPLY
VOLTAGE AND TEMPERATURE
SUPPLY VOLTAGE: V+ = 15V, V- = -15V
TA = +25oC
0
TA = -55oC
6
0
25
20
7
104
FIGURE 7. EQUIVALENT INPUT NOISE VOLTAGE vs
FREQUENCY
SUPPLY VOLTAGE: V+ = 15V, V- = -15V
TA = +25oC
100
CA3140B
80
CA3140A
60
40
-PSRR
20
POWER SUPPLY REJECTION RATIO
(PSRR) = ∆VIO/∆VS
0
101
105
+PSRR
CA3140,
102
103
104
105
106
107
FREQUENCY (Hz)
FIGURE 8. POWER SUPPLY REJECTION RATIO vs FREQUENCY
2-130
CA3140, CA3140A
Applications Considerations
Wide dynamic range of input and output characteristics with
the most desirable high input impedance characteristics is
achieved in the CA3140 by the use of an unique design based
upon the PMOS Bipolar process. Input common mode voltage
range and output swing capabilities are complementary,
allowing operation with the single supply down to 4V.
The wide dynamic range of these parameters also means
that this device is suitable for many single supply applications, such as, for example, where one input is driven below
the potential of terminal 4 and the phase sense of the output
signal must be maintained – a most important consideration
in comparator applications.
Figure 10 shows output current sinking capabilities of the
CA3140 at various supply voltages. Output voltage swing to
the negative supply rail permits this device to operate both
power transistors and thyristors directly without the need for
level shifting circuitry usually associated with the 741 series
of operational amplifiers.
Figure 13 shows some typical configurations. Note that a
series resistor, RL, is used in both cases to limit the drive
available to the driven device. Moreover, it is recommended
that a series diode and shunt diode be used at the thyristor
input to prevent large negative transient surges that can
appear at the gate of thyristors, from damaging the integrated circuit.
Output Circuit Considerations
7
OFFSET-VOLTAGE SHIFT (mV)
Excellent interfacing with TTL circuitry is easily achieved
with a single 6.2V zener diode connected to terminal 8 as
shown in Figure 9. This connection assures that the maximum output signal swing will not go more positive than the
zener voltage minus two base-to-emitter voltage drops within
the CA3140. These voltages are independent of the operating supply voltage.
V+
5V TO 36V
LOGIC
SUPPLY
5V
7
8
2
6.2V
6
DIFFERENTIAL DC VOLTAGE
(ACROSS TERMS 2 AND 3) = 2V
OUTPUT STAGE TOGGLED
5
4
3
2
DIFFERENTIAL DC VOLTAGE
(ACROSS TERMS 2 AND 3) = 0V
OUTPUT VOLTAGE = V+ / 2
1
0
≈5V
6
CA3140
TA = +125oC
FOR TO-5 PACKAGES
0
500 1000 1500 2000 2500 3000 3500 4000 4500
TYPICAL
TTL GATE
TIME (HOURS)
3
4
FIGURE 11. TYPICAL INCREMENTAL OFFSET VOLTAGE SHIFT
vs OPERATING LIFE
Offset Voltage Nulling
FIGURE 9. ZENER CLAMPING DIODE CONNECTED TO TERMINALS 8 AND 4 TO LIMIT CA3140 OUTPUT SWING
TO TTL LEVELS
OUTPUT STAGE TRANSISTOR (Q15, Q16)
SATURATION VOLTAGE (mV)
1000
8
6
4
SUPPLY VOLTAGE (V-) = 0V
TA = +25oC
2
100
SUPPLY VOLTAGE (V+) = +5V
+15V
8
6
An alternate system is shown in Figure 12(C). This circuit
uses only one additional resistor of approximately the value
shown in the table. For potentiometers, in which the resistance does not drop to zero Ω at either end of rotation, a
value of resistance 10% lower than the values shown in the
table should be used.
+30V
4
2
10
The input offset voltage can be nulled by connecting a 10kΩ
potentiometer between terminals 1 and 5 and returning its
wiper arm to terminal 4, see Figure 12(A). This technique,
however, gives more adjustment range than required and
therefore, a considerable portion of the potentiometer rotation is not fully utilized. Typical values of series resistors that
may be placed at either end of the potentiometer, see Figure
12(B), to optimize its utilization range are given in the table
“Electrical Specifications” shown in this bulletin.
8
6
4
Low Voltage Operation
2
1
0.01
2
4
6
8
0.1
2
4
6
8
2
1.0
4
6
8
10
LOAD (SINKING) CURRENT (mA)
FIGURE 10. VOLTAGE ACROSS OUTPUT TRANSISTORS Q15
AND Q16 vs LOAD CURRENT
Operation at total supply voltages as low as 4V is possible
with the CA3140. A current regulator based upon the PMOS
threshold voltage maintains reasonable constant operating
current and hence consistent performance down to these
lower voltages.
The low voltage limitation occurs when the upper extreme of
the input common mode voltage range extends down to the
2-131
CA3140, CA3140A
V+
2
V+
2
7
CA3140
3
2
7
3
3
4
5
1
5
1
10kΩ
6
CA3140
4
5
7
6
CA3140
6
4
V+
1
10kΩ
10kΩ
V-
VV-
(A) BASIC
(B) IMPROVED
RESOLUTION
(C) SIMPLER
IMPROVED
RESOLUTION
FIGURE 12. THREE OFFSET VOLTAGE NULLING METHODS
V+
RS
2
LOAD
30V
NO LOAD
120VAC
LOAD
6
CA3140
MT2
7
+HV
7
RL
2
3
4
6
CA3140
MT1
RL
3
4
FIGURE 13. METHODS OF UTILIZING THE VCE(SAT) SINKING CURRENT CAPABILITY OF THE CA3140 SERIES
FOLLOWER
+15V
7
0.1µF
3
LOAD RESISTANCE (RL) = 2kΩ
LOAD CAPACITANCE (CL) = 100pF
CA3140
SUPPLY VOLTAGE: V+ = +15V, V- = -15V
TA = +25oC
6
2kΩ
100pF
2
4
0.1µF
10
1mV
1mV
-15V
8
INPUT VOLTAGE (V)
SIMULATED
LOAD
10kΩ
10mV
6
10mV
2kΩ
4
0.05µF
2
FOLLOWER
0
INVERTING
INVERTING
-2
5kΩ
-4
+15V
-6
1mV
-8
-10
0.1
10mV
2
4
6
1mV
7
10mV
8
2
1.0
SETTLING TIME (µs)
0.1µF
2
4
6
8
SIMULATED
LOAD
5kΩ
10
CA3140
200Ω
6
100pF
3
4
(A)
0.1µF
4.99kΩ
5.11kΩ
-15V
SETTLING POINT
D1
IN914
D2
IN914
(B) TEST CIRCUITS
FIGURE 14. INPUT VOLTAGE vs SETTLING TIME
2-132
2kΩ
CA3140, CA3140A
voltage at terminal 4. This limit is reached at a total supply
voltage just below 4V. The output voltage range also begins
to extend down to the negative supply rail, but is slightly
higher than that of the input. Figure 17 shows these
characteristics and shows that with 2V dual supplies, the
lower extreme of the input common mode voltage range is
below ground potential.
Bandwidth and Slew Rate
For those cases where bandwidth reduction is desired, for
example, broadband noise reduction, an external capacitor
connected between terminals 1 and 8 can reduce the open
loop -3dB bandwidth. The slew rate will, however, also be
proportionally reduced by using this additional capacitor.
Thus, a 20% reduction in bandwidth by this technique will
also reduce the slew rate by about 20%.
100
φOL
RL = 2kΩ,
CL = 0pF
-90
-105
-120
-135
80
-150
As mentioned previously, the amplifier inputs can be driven
below the terminal 4 potential, but a series current limiting
resistor is recommended to limit the maximum input terminal
current to less than 1mA to prevent damage to the input protection circuitry.
Moreover, some current limiting resistance should be
provided between the inverting input and the output when
the CA3140 is used as a unity gain voltage follower. This
resistance prevents the possibility of extremely large input
signal transients from forcing a signal through the input
protection network and directly driving the internal constant
current source which could result in positive feedback via the
output terminal. A 3.9kΩ resistor is sufficient.
10K 8
6
4
60
RL = 2kΩ,
CL = 100pF
40
SUPPLY VOLTAGE: V+ = 15V, V- = -15V
2
INPUT CURRENT (pA)
SUPPLY VOLTAGE: V+ = 15V, V- = -15V
TA = +25oC
-75
Input Circuit Considerations
OPEN LOOP PHASE
(DEGREES)
OPEN LOOP VOLTAGE GAIN (dB)
Figure 14 shows the typical settling time required to reach
1mV or 10mV of the final value for various levels of large
signal inputs for the voltage follower and inverting unity gain
amplifiers. The exceptionally fast settling time characteristics
are largely due to the high combination of high gain and wide
bandwidth of the CA3140; as shown in Figure 15.
1K 8
6
4
2
100
8
6
4
2
10 8
6
4
20
2
0
101
102
103
104
105
106
107
1
108
-60
-40
-20
FREQUENCY (Hz)
RL = ∞
0
+125oC
-0.5 +VICR AT TA =
+VICR AT TA = +25oC
-1.0 +V
AT T = -55oC
ICR
A
+VOUT AT TA = +125oC
+VOUT AT TA = +25oC
+VOUT AT TA = -55oC
-1.5
-2.0
-2.5
-3.0
0
5
10
15
SUPPLY VOLTAGE (V+, V-)
20
120
140
FIGURE 16. INPUT CURRENT vs AMBIENT TEMPERATURE
INPUT AND OUTPUT VOLTAGE EXCURSIONS
FROM TERMINAL 4 (V-)
INPUT AND OUTPUT VOLTAGE EXCURSIONS
FROM TERMINAL 7 (V+)
FIGURE 15. OPEN LOOP VOLTAGE GAIN AND PHASE vs
FREQUENCY
0
20
40
60
80 100
AMBIENT TEMPERATURE (oC)
25
1.5
-VICR AT TA = +125oC
1.0
-VICR AT TA = +25oC
0.5
-VOUT FOR TA =
oC
-55
to
-VICR AT TA = -55oC
+125oC
0
-0.5
-1.0
-1.5
0
5
10
15
SUPPLY VOLTAGE (V+, V-)
20
25
FIGURE 17. OUTPUT VOLTAGE SWING CAPABILITY AND COMMON MODE INPUT VOLTAGE RANGE vs SUPPLY VOLTAGE AND
TEMPERATURE
2-133
CA3140, CA3140A
The typical input current is in the order of 10pA when the
inputs are centered at nominal device dissipation. As the
output supplies load current, device dissipation will increase,
raising the chip temperature and resulting in increased input
current. Figure 16 shows typical input terminal current versus ambient temperature for the CA3140.
It is well known that MOSFET devices can exhibit slight
changes in characteristics (for example, small changes in
input offset voltage) due to the application of large differential input voltages that are sustained over long periods at elevated temperatures.
Both applied voltage and temperature accelerate these
changes. The process is reversible and offset voltage shifts
of the opposite polarity reverse the offset. Figure 11 shows
the typical offset voltage change as a function of various
stress voltages at the maximum rating of +125oC (for TO-5);
at lower temperatures (TO-5 and plastic), for example, at
+85oC, this change in voltage is considerably less. In typical
linear applications, where the differential voltage is small and
symmetrical, these incremental changes are of about the
same magnitude as those encountered in an operational
amplifier employing a bipolar transistor input stage.
Super Sweep Function Generator
A function generator having a wide tuning range is shown in
Figure 18. The 1,000,000/1 adjustment range is accomplished by a single variable potentiometer or by an auxiliary
sweeping signal. The CA3140 functions as a non-inverting
readout amplifier of the triangular signal developed across
the integrating capacitor network connected to the output of
the CA3080A current source.
Buffered triangular output signals are then applied to a second CA3080 functioning as a high speed hysteresis switch.
Output from the switch is returned directly back to the input
of the CA3080A current source, thereby, completing the positive feedback loop
The triangular output level is determined by the four 1N914
level limiting diodes of the second CA3080 and the resistor
divider network connected to terminal No. 2 (input) of the
CA3080. These diodes establish the input trip level to this
switching stage and, therefore, indirectly determine the
amplitude of the output triangle.
Compensation for propagation delays around the entire loop
is provided by one adjustment on the input of the CA3080.
This adjustment, which provides for a constant generator
amplitude output, is most easily made while the generator is
sweeping. High frequency ramp linearity is adjusted by the
single 7-to-6pF capacitor in the output of the CA3080A.
It must be emphasized that only the CA3080A is
characterized for maximum output linearity in the current
generator function.
Meter Driver and Buffer Amplifier
Figure 19 shows the CA3140 connected as a meter driver
and buffer amplifier. Low driving impedance is required of
the CA3080A current source to assure smooth operation of
the Frequency Adjustment Control. This low-driving
impedance requirement is easily met by using a CA3140
connected as a voltage follower. Moreover, a meter may be
placed across the input to the CA3080A to give a logarithmic
analog indication of the function generators frequency.
Analog frequency readout is readily accomplished by the
means described above because the output current of the
CA3080A varies approximately one decade for each 60mV
change in the applied voltage, VABC (voltage between
terminals 5 and 4 of the CA3080A of the function generator).
Therefore, six decades represent 360mV change in VABC.
Now, only the reference voltage must be established to set
the lower limit on the meter. The three remaining transistors
from the CA3086 Array used in the sweep generator are
used for this reference voltage. In addition, this reference
generator arrangement tends to track ambient temperature
variations, and thus compensates for the effects of the normal negative temperature coefficient of the CA3080A VABC
terminal voltage.
Another output voltage from the reference generator is used
to insure temperature tracking of the lower end of the
Frequency Adjustment Potentiometer. A large series
resistance simulates a current source, assuring similar
temperature coefficients at both ends of the Frequency
Adjustment Control.
To calibrate this circuit, set the Frequency Adjustment
Potentiometer at its low end. Then adjust the Minimum
Frequency Calibration Control for the lowest frequency. To
establish the upper frequency limit, set the Frequency
Adjustment Potentiometer to its upper end and then adjust
the Maximum Frequency Calibration Control for the
maximum frequency. Because there is interaction among
these controls, repetition of the adjustment procedure may
be necessary. Two adjustments are used for the meter. The
meter sensitivity control sets the meter scale width of each
decade, while the meter position control adjusts the pointer
on the scale with negligible effect on the sensitivity
adjustment. Thus, the meter sensitivity adjustment control
calibrates the meter so that it deflects 1/6 of full scale for
each decade change in frequency.
Sine Wave Shaper
The circuit shown in Figure 20 uses a CA3140 as a voltage
follower in combination with diodes from the CA3019 Array
to convert the triangular signal from the function generator to
a sine-wave output signal having typically less than 2% THD.
The basic zero crossing slope is established by the 10kΩ
potentiometer connected between terminals 2 and 6 of the
CA3140 and the 9.1kΩ resistor and 10kΩ potentiometer
from terminal 2 to ground. Two break points are established
by diodes D1 through D4. Positive feedback via D5 and D6
establishes the zero slope at the maximum and minimum
levels of the sine wave. This technique is necessary because
the voltage follower configuration approaches unity gain
rather than the zero gain required to shape the sine wave at
the two extremes.
2-134
CA3140, CA3140A
CENTERING
-15V 10kΩ
7.5kΩ
+15V
360Ω
3
7
+
15kΩ
-
2
4
5
2MΩ
51
pF
7-60
pF
-15V
+15V
39Ω
-15V
120Ω
+
CA3140
3
-
2
HIGH
FREQ.
SHAPE
0.1
µF
FREQUENCY
ADJUSTMENT
+15V
THIS NETWORK IS USED WHEN THE
OPTIONAL BUFFER CIRCUIT IS NOT USED
5.1
kΩ
+15V
62kΩ
10kΩ
5
6
CA3080
+
4
3
EXTERNAL
OUTPUT
EXTERNAL
OUTPUT
7
-
2
11kΩ
11kΩ
10kΩ
-15V
2kΩ
10kΩ
910
kΩ
6
4
100kΩ
FROM BUFFER METER
DRIVER (OPTIONAL)
0.1
µF
7
6
CA3080A
360Ω
SYMMETRY
-15V
+15V
HIGH
FREQUENCY
LEVEL
7-60pF
2.7kΩ
-15V
13kΩ
TO OUTPUT
AMPLIFIER
TO
SINE WAVE
SHAPER
IN914
OUTPUT
AMPLIFIER
(A) CIRCUIT
FREQUENCY
ADJUSTMENT
(B1) FUNCTION GENERATOR SWEEPING
+15V
METER DRIVER
AND BUFFER
AMPLIFIER
Top Trace: Output at junction of 2.7Ω and 51Ω resistors
5V/Div and 500ms/Div
Center Trace: External output of triangular function generator
2V/Div and 500ms/Div
POWER
SUPPLY ±15V
M
-15V
FUNCTION
GENERATOR
Bottom Trace: Output of “Log” generator; 10V/Div and 500ms/Div
WIDEBAND
LINE DRIVER
SINE WAVE
SHAPER
51Ω
FINE
RATE
SWEEP
GENERATOR
GATE DC LEVEL
SWEEP ADJUST
OFF INT.
COARSE
RATE
V-
EXT.
SWEEP
LENGTH
V-
(B2) FUNCTION GENERATOR WITH FIXED FREQUENCIES
(C) INTERCONNECTIONS
1V/Div and 1sec/Div
Three tone test signals, highest frequency ≥0.5MHz. Note the slight
asymmetry at the three second/cycle signal. This asymmetry is due
to slightly different positive and negative integration from the
CA3080A and from the pc board and component leakages at the
100pA level.
FIGURE 18. FUNCTION GENERATOR
2-135
EXTERNAL
INPUT
CA3140, CA3140A
500kΩ
FREQUENCY
ADJUSTMENT
10kΩ
FREQUENCY
CALIBRATION
MAXIMUM
620kΩ
7
51kΩ
3
+
6
CA3140
SWEEP IN
3MΩ
-
2
4.7kΩ
4
+15V
2kΩ
0.1µF
12
kΩ
FREQUENCY 2.4kΩ
CALIBRATION
MINIMUM
2.5
kΩ
0.1µF
5.1kΩ
6
3/
5
10kΩ
D4
5
8
3.6kΩ 13
3
4
D5
CA3019
DIODE ARRAY
OF CA3086
-15V
FIGURE 19. METER DRIVER AND BUFFER AMPLIFIER
FIGURE 20. SINE WAVE SHAPER
750kΩ
“LOG”
100kΩ
SAWTOOTH 18MΩ
IN914
IN914
SAWTOOTH
SYMMETRY
0.47µF
0.047µF
FINE
RATE
100kΩ
1MΩ
22MΩ
8.2kΩ
+15V SAWTOOTH AND
RAMP LOW LEVEL
SET (-14.5V)
COARSE
RATE
4700pF
50kΩ
75kΩ
470pF
+15V
2
-
3
+
7
“LOG” +15V
+15V
36kΩ
TRIANGLE
6
CA3140
51kΩ
SAWTOOTH
0.1
µF
4
50kΩ
LOG
RATE
ADJUST
-15V
43kΩ
TO OUTPUT
AMPLIFIER
10kΩ
10kΩ
7
-
3
10kΩ
6
CA3140
100kΩ
30kΩ
0.1
µF
+
2
4
-15V
EXTERNAL OUTPUT
TO FUNCTION GENERATOR “SWEEP IN”
SWEEP WIDTH
-15V
3
6
CA3140
2
LOGVIO
+15V
7
+
5
1
51kΩ
4
6.8kΩ
91kΩ
10kΩ
TRIANGLE
25kΩ
3.9Ω
-15V
5
1
4
2
100Ω
390Ω
2
D3 D6
D2
1
9
12
METER
POSITION
ADJUSTMENT
TO
WIDEBAND
OUTPUT
AMPLIFIER
9.1kΩ
R1
10kΩ
14
10
2kΩ
7
D1
-15V
7.5
kΩ
EXTERNAL
OUTPUT
1MΩ
100
kΩ
510Ω
SUBSTRATE
OF CA3019
7
-15V
R3 10kΩ
+15V
9
6
4
0.1µF
1kΩ
11
8
-
620Ω
5.6
kΩ
6
CA3140
200µA
M METER
510Ω
7
+
3
2
METER
SENSITIVITY
ADJUSTMENT
-15V
+15V
TO CA3080A
OF FUNCTION CA3080A
GENERATOR
(FIGURE 18)
4
5
TRANSISTORS
FROM CA3086
ARRAY
3
FIGURE 21. SWEEPING GENERATOR
2-136
SAWTOOTH
“LOG”
GATE
PULSE
OUTPUT
430Ω
R2
1kΩ
CA3140, CA3140A
This circuit can be adjusted most easily with a distortion
analyzer, but a good first approximation can be made by
comparing the output signal with that of a sine wave
generator. The initial slope is adjusted with the
potentiometer R1, followed by an adjustment of R2. The final
slope is established by adjusting R3, thereby adding
additional segments that are contributed by these diodes.
Because there is some interaction among these controls,
repetition of the adjustment procedure may be necessary.
REFERENCE
VOLTAGE
VOLTAGE
ADJUSTMENT
3
+
7
CA3140
INPUT
2
-
6
REGULATED
OUTPUT
4
Sweeping Generator
Figure 21 shows a sweeping generator. Three CA3140's are
used in this circuit. One CA3140 is used as an integrator, a
second device is used as a hysteresis switch that determines the starting and stopping points of the sweep. A third
CA3140 is used as a logarithmic shaping network for the log
function. Rates and slopes, as well as sawtooth, triangle,
and logarithmic sweeps are generated by this circuit.
Wideband Output Amplifier
Figure 22 shows a high slew rate, wideband amplifier
suitable for use as a 50Ω transmission line driver. This
circuit, when used in conjunction with the function generator
and sine wave shaper circuits shown in Figures 18 and 20
provides 18V peak-to-peak output open circuited, or 9V
peak-to-peak output when terminated in 50Ω. The slew rate
required of this amplifier is 28V/µs (18V peak-to-peak x π x
0.5MHz).
+15V
+
SIGNAL
LEVEL
ADJUSTMENT
2.5kΩ
3
7
+
2
-
-15V
200Ω
4
+
2.4pF
2pF
1.8kΩ
2N3053
IN914
2.7Ω
IN914
2.7Ω
51Ω
OUT
2W
8
1
OUTPUT
DC LEVEL +15V
ADJUSTMENT
3kΩ
2.2
kΩ
6
CA3140
200Ω
50µF
25V
50µF
25V
2.2
kΩ
2N4037
-15V
NOMINAL BANDWIDTH = 10MHz
tr = 35ns
FIGURE 22. WIDEBAND OUTPUT AMPLIFIER
Power Supplies
High input impedance, common mode capability down to the
negative supply and high output drive current capability are
key factors in the design of wide range output voltage
supplies that use a single input voltage to provide a
regulated output voltage that can be adjusted from
essentially 0V to 24V.
Unlike many regulator systems using comparators having a
bipolar transistor input stage, a high impedance reference
voltage divider from a single supply can be used in
connection with the CA3140 (see Figure 23).
FIGURE 23. BASIC SINGLE SUPPLY VOLTAGE REGULATOR
SHOWING VOLTAGE FOLLOWER CONFIGURATION
Essentially, the regulators, shown in Figures 24 and 25, are
connected as non inverting power operational amplifiers with
a gain of 3.2. An 8V reference input yields a maximum output voltage slightly greater than 25V. As a voltage follower,
when the reference input goes to 0V the output will be 0V.
Because the offset voltage is also multiplied by the 3.2 gain
factor, a potentiometer is needed to null the offset voltage.
Series pass transistors with high ICBO levels will also prevent
the output voltage from reaching zero because there is a
finite voltage drop (VCEsat) across the output of the CA3140
(see Figure 10). This saturation voltage level may indeed set
the lowest voltage obtainable.
The high impedance presented by terminal 8 is advantageous in effecting current limiting. Thus, only a small signal
transistor is required for the current-limit sensing amplifier.
Resistive decoupling is provided for this transistor to minimize damage to it or the CA3140 in the event of unusual
input or output transients on the supply rail.
Figures 24 and 25, show circuits in which a D2201 high
speed diode is used for the current sensor. This diode was
chosen for its slightly higher forward voltage drop characteristic, thus giving greater sensitivity. It must be emphasized
that heat sinking of this diode is essential to minimize variation of the current trip point due to internal heating of the
diode. That is, 1A at 1V forward drop represents one watt
which can result in significant regenerative changes in the
current trip point as the diode temperature rises. Placing the
small signal reference amplifier in the proximity of the current
sensing diode also helps minimize the variability in the trip
level due to the negative temperature coefficient of the
diode. In spite of those limitations, the current limiting point
can easily be adjusted over the range from 10mA to 1A with
a single adjustment potentiometer. If the temperature stability of the current limiting system is a serious consideration,
the more usual current sampling resistor type of circuitry
should be employed.
A power Darlington transistor (in a heat sink TO-3 case), is used
as the series pass element for the conventional current limiting
system, Figure 24, because high power Darlington dissipation
will be encountered at low output voltage and high currents.
A small heat sink VERSAWATT transistor is used as the
series pass element in the fold back current system, Figure
25, since dissipation levels will only approach 10W. In this
system, the D2201 diode is used for current sampling. Fold-
2-137
CA3140, CA3140A
back is provided by the 3kΩ and 100kΩ divider network connected to the base of the current sensing transistor.
+30V
3
2N6385
CURRENT
POWER DARLINGTON LIMITING
ADJUST
D2201
2
75Ω
1kΩ
OUTPUT
0.1 ⇒ 24V
AT 1A
1kΩ
1kΩ
2
2N2102
100Ω
1
8
Figure 28 (a) shows the turn ON and turn OFF characteristics of both regulators. The slow turn on rise is due to the
slow rate of rise of the reference voltage. Figure 26 (B)
shows the transient response of the regulator with the
switching of a 20Ω load at 20V output.
1
3kΩ
Both regulators, Figures 24 and 25, provide better than 0.02%
load regulation. Because there is constant loop gain at all voltage settings, the regulation also remains constant. Line regulation is 0.1% per volt. Hum and noise voltage is less than
200µV as read with a meter having a 10MHz bandwidth.
3
1kΩ
56pF
7
180kΩ
2
6
2.7kΩ 10µF
5
-
1kΩ
CA3140
+
1
100kΩ
82kΩ
3
4
INPUT
+
2.2kΩ
-
10 11
1 2
9
3
8 7
5
6
4
VOLTAGE
ADJUST
5µF 50kΩ
-
100kΩ
14
+
250µF
12
0.01µF
13
CA3086
1kΩ
(A) SUPPLY TURN-ON AND TURNOFF CHARACTERISTICS
62kΩ
HUM AND NOISE OUTPUT <200µVRMS
(MEASUREMENT BANDWIDTH ~10MHz)
LINE REGULATION 0.1%/VOLT
5V/Div and -1s/Div
LOAD REGULATION
(NO LOAD TO FULL LOAD)
<0.02%
FIGURE 24. REGULATED POWER SUPPLY
OUTPUT ⇒ 0V TO 25V
25V AT 1A
“FOLDS BACK”
TO 40mA
“FOLDBACK” CURRENT
LIMITER
2N5294
D2201
2
3
+30V
1kΩ 200Ω
1
100kΩ
3kΩ
100kΩ
2N2102
8
1kΩ
56pF
7
180kΩ
2
2.7kΩ 10µF
5
-
1kΩ
CA3140
6
+
1
100kΩ
82kΩ
(B) TRANSIENT RESPONSE
3
4
Top Trace: Output voltage
200mV/Div and 5µs/Div
INPUT
+
2.2kΩ
-
10 11
1 2
9
3
8 7
5
6
4
5µF 50kΩ
14
VOLTAGE
ADJUST
100kΩ
+
-
250µF
Bottom Trace: Collector of load switching transistor, load = 1A
5V/Div and 5µs/Div
FIGURE 26. WAVEFORMS OF DYNAMIC CHARACTERISTICS
OF POWER SUPPLY CURRENTS SHOWN IN FIGURES 24 AND 25
12
0.01µF
13
CA3086
Tone Control Circuits
1kΩ
High slew rate, wide bandwidth, high output voltage capability and high input impedance are all characteristics required
of tone control amplifiers. Two tone control circuits that
exploit these characteristics of the CA3140 are shown in Figures 27 and 28.
62kΩ
HUM AND NOISE OUTPUT <200µVRMS
(MEASUREMENT BANDWIDTH ~10MHz)
LINE REGULATION 0.1%/VOLT
LOAD REGULATION
(NO LOAD TO FULL LOAD)
<0.02%
FIGURE 25. REGULATED POWER SUPPLY WITH “FOLDBACK”
CURRENT LIMITING
2-138
CA3140, CA3140A
Figure 27 shows another tone control circuit with similar
boost and cut specifications. The wideband gain of this circuit is equal to the ultimate boost or cut plus one, which in
this case is a gain of eleven. For 20dB boost and cut, the
input loading of this circuit is essentially equal to the value of
the resistance from terminal No. 3 to ground. A detailed
analysis of this circuit is given in “An IC Operational
TransconductanceAmplifier (OTA) With Power Capability” by
L. Kaplan and H. Wittlinger, IEEE Transactions on Broadcast
and Television Receivers, Vol. BTR-18, No. 3, August, 1972.
The first circuit, shown in Figure 28, is the Baxandall tone
control circuit which provides unity gain at midband and uses
standard linear potentiometers. The high input impedance of
the CA3140 makes possible the use of low-cost, low-value,
small size capacitors, as well as reduced load of the driving
stage.
Bass treble boost and cut are ±15dB at 100Hz and 10kHz,
respectively. Full peak-to-peak output is available up to at
least 20kHz due to the high slew rate of the CA3140. The
amplifier gain is 3dB down from its “flat” position at 70kHz.
FOR SINGLE SUPPLY
20dB Flat Position Gain
±15dB Bass and Treble Boost and Cut at
100Hz and 10kHz, respectively
25VP-P output at 20kHz
-3dB at 24kHz from 1kHz reference
+30V
2.2MΩ
7
0.005µF
5.1
MΩ
3
+
CA3140
2
-
0.1µF
6
4
BOOST
2.2MΩ
0.1
µF
0.012µF
TREBLE
CUT
200kΩ
(LINEAR) 0.001µF
18kΩ
100
pF
FOR DUAL SUPPLIES
+15V
3
7
+
CA3140
2
-
0.005µF
100pF
5.1MΩ
4
0.022µF
2µF
- +
0.0022µF
0.1µF
6
0.1µF
-15V
10kΩ
1MΩ
100kΩ
CCW (LOG)
BOOST
BASS
CUT
TONE CONTROL NETWORK
TONE CONTROL NETWORK
FIGURE 27. TONE CONTROL CIRCUIT USING CA3130 SERIES (20dB MIDBAND GAIN)
FOR SINGLE SUPPLY
BOOST
0.047µF
BASS
CUT
(LINEAR)
240kΩ
5MΩ
240kΩ
FOR DUAL SUPPLIES
2.2MΩ
750
pF
+32V
750
pF
+15V
7
3
2.2MΩ
0.1
µF
22
MΩ 2
+
CA3140
0.1
µF
6
0.047µF
4
TONE CONTROL
NETWORK
20pF
51kΩ
5MΩ
51kΩ
(LINEAR)
BOOST TREBLE
CUT
TONE CONTROL NETWORK
3
7
+
CA3140
2
4
-15V
±15dB Bass and Treble Boost and Cut at
100Hz and 10kHz, respectively
25VP-P output at 20kHz
-3dB at 70kHz from 1kHz reference
0dB Flat Position Gain
FIGURE 28. BAXANDALL TONE CONTROL CIRCUIT USING CA3140 SERIES
2-139
0.1µF
6
0.1µF
CA3140, CA3140A
Wien Bridge Oscillator
Another application of the CA3140 that makes excellent use
of its high input impedance, high slew rate, and high voltage
qualities is the Wien Bridge sine wave oscillator. A basic Wien
Bridge oscillator is shown in Figure 29. When R1 = R2 = R and
C1 = C2 = C, the frequency equation reduces to the familiar
f = 1/2 π RC and the gain required for oscillation, AOSC is
equal to 3. Note that if C2 is increased by a factor of four and
R2 is reduced by a factor of four, the gain required for
oscillation becomes 1.5, thus permitting a potentially higher
operating frequency closer to the gain bandwidth product of
the CA3140.
C2
R2
NOTES:
f
2π
A
Rf
C1
OS
C1
C2
RS
C1 2
1000
pF
R1
7
+
CA3140
4
0.1µF
CA3109
DIODE
ARRAY
6
SUBSTRATE
OF CA3019
8
9
1
2
6
0.1µF
3
7
0.1µF
-15V
7.5kΩ
5
4
R1 = R2 = R
50Hz, R =
100Hz, R =
1kHz, R =
10kHz, R =
30kHz, R =
3.3MΩ
1.6MΩ
160MΩ
16MΩ
5.1MΩ
3.6kΩ
500Ω
FIGURE 30. WIEN BRIDGE OSCILLATOR CIRCUIT USING
CA3140 SERIES
R2
R1
= 1 + ------- + -------
Simple Sample-and-Hold System
R
R1
3
R1C1R2C2
OUTPUT
-
1000pF
1
= ---------------------------
+
+15V
R2
C2
OUTPUT
19VP-P TO 22VP-P
THD <0.3%
A
CL
f
= 1 + ------R
S
FIGURE 29. BASIC WIEN BRIDGE OSCILLATOR CIRCUIT USING AN OPERATIONAL AMPLIFIER
Oscillator stabilization takes on many forms. It must be
precisely set, otherwise the amplitude will either diminish or
reach some form of limiting with high levels of distortion. The
element, RS, is commonly replaced with some variable
resistance element. Thus, through some control means, the
value of RS is adjusted to maintain constant oscillator output.
A FET channel resistance, a thermistor, a lamp bulb, or other
device whose resistance is made to increase as the output
amplitude is increased are a few of the elements often
utilized.
Figure 30 shows another means of stabilizing the oscillator
with a zener diode shunting the feedback resistor (Rf of
Figure 29). As the output signal amplitude increases, the
zener diode impedance decreases resulting in more
feedback with consequent reduction in gain; thus stabilizing
the amplitude of the output signal. Furthermore, this
combination of a monolithic zener diode and bridge rectifier
circuit tends to provide a zero temperature coefficient for this
regulating system. Because this bridge rectifier system has
no time constant, i.e., thermal time constant for the lamp
bulb, and RC time constant for filters often used in detector
networks, there is no lower frequency limit. For example,
with 1µF polycarbonate capacitors and 22MΩ for the
frequency determining network, the operating frequency is
0.007Hz.
As the frequency is increased, the output amplitude must be
reduced to prevent the output signal from becoming slewrate limited. An output frequency of 180kHz will reach a slew
rate of approximately 9V/µs when its amplitude is 16V peakto-peak.
Figure 31 shows a very simple sample-and-hold system
using the CA3140 as the readout amplifier for the storage
capacitor. The CA3080A serves as both input buffer amplifier and low feed-through transmission switch.* System offset nulling is accomplished with the CA3140 via its offset
nulling terminals. A typical simulated load of 2kΩ and 30pF
is shown in the schematic.
0
30kΩ
SAMPLE
STROBE
-15
IN914
HOLD
+15V
IN914
INPUT
+15V
5
2kΩ
+
3
CA3080A
-
2
0.1µF
7
4
6
3
+
CA3140
2
-
0.1µF
2kΩ
6
0.1
µF
4
5
-15V
3.5kΩ
7
1
100kΩ
-15V
2kΩ
200pF
200pF
2kΩ
400Ω
0.1µF
SIMULATED LOAD
NOT REQUIRED
30pF
FIGURE 31. SAMPLE AND HOLD CIRCUIT
In this circuit, the storage compensation capacitance (C1) is
only 200pF. Larger value capacitors provide longer “hold”
periods but with slower slew rates. The slew rate
i
dv
------ = --- = 0.5mA ⁄ 200pF = 2.5V ⁄ µs
c
dt
* ICAN-6668 “Applications of the CA3080 and CA 3080A High Performance Operational Transconductance Amplifiers”.
Pulse “droop” during the hold interval is 170pA/200pF which
is = 0.85µV/µs; (i.e., 170pA/200pF). In this case, 170pA
2-140
CA3140, CA3140A
represents the typical leakage current of the CA3080A when
strobed off. If C1 were increased to 2000 pF, the “hold-droop”
rate will decrease to 0.085µV/µs, but the slew rate would
decrease to 0.25V/µs. The parallel diode network connected
between terminal 3 of the CA3080A and terminal 6 of the
CA3140 prevents large input signal feedthrough across the
input terminals of the CA3080A to the 200pF storage capacitor
when the CA3080A is strobed off. Figure 32 shows dynamic
characteristic waveforms of this sample-and-hold system.
Current Amplifier
The low input terminal current needed to drive the CA3140
makes it ideal for use in current amplifier applications such
as the one shown in Figure 33.* In this circuit, low current is
supplied at the input potential as the power supply to load
resistor RL. This load current is increased by the multiplication factor R2/R1, when the load current is monitored by the
power supply meter M. Thus, if the load current is 100nA,
with values shown, the load current presented to the supply
will be 100µA; a much easier current to measure in many
systems.
R1
10kΩ
+15V
IL
R2
R1
0.1µF
3
M
2
POWER
SUPPLY
Top Trace: Output; 50mV/Div and 200ns/Div
Bottom Trace: Input; 50mV/Div and 200ns/Div
7
+
CA3140
5
4
1
R2
6
0.1µF
10MΩ
IL
RL
100kΩ
4.3kΩ
-15V
FIGURE 33. BASIC CURRENT AMPLIFIER FOR LOW CURRENT
MEASUREMENT SYSTEMS
Note that the input and output voltages are transferred at the
same potential and only the output current is multiplied by
the scale factor.
The dotted components show a method of decoupling the
circuit from the effects of high output load capacitance and
the potential oscillation in this situation. Essentially, the
necessary high frequency feedback is provided by the
capacitor with the dotted series resistor providing load
decoupling.
LARGE SIGNAL RESPONSE AND SETTLING TIME
Top Trace: Output Signal; 5V/Div and 2µs/Div
Center Trace: Difference of Input and Output Signals through
Tektronix Amplifier 7A13; 5mV/Div and 2µs/Div
Bottom Trace: Input Signal; 5V/Div and 2µs/Div
Figure 34 shows a single supply, absolute value, ideal fullwave rectifier with associated waveforms. During positive
excursions, the input signal is fed through the feedback
network directly to the output. Simultaneously, the positive
excursion of the input signal also drives the output terminal
(No. 6) of the inverting amplifier in a negative going
excursion such that the 1N914 diode effectively disconnects
the amplifier from the signal path. During a negative going
excursion of the input signal, the CA3140 functions as a
normal inverting amplifier with a gain equal to -R2/R1. When
the equality of the two equations shown in Figure 34 is
satisfied, the full wave output is symmetrical.
SAMPLING RESPONSE
* “Operational Amplifiers Design and Applications”, J. G. Graeme,
McGraw-Hill Book Company, page 308 - “Negative Immittance
Converter Circuits”.
Top Trace: Output; 100mV/Div and 500ns/Div
Bottom Trace: Input; 20V/Div and 500ns/Div
FIGURE 32. SAMPLE AND HOLD SYSTEM DYNAMIC CHARACTERISTICS WAVEFORMS
2-141
CA3140, CA3140A
+15V
R2
5kΩ
+15V
0.1µF
R1
2
-
10kΩ
+
8
3
1
5
6
4
2
1N914
SIMULATED
LOAD
+
CA3140
CA3140
3
0.1µF
7
7
100kΩ
6
-
100pF
4
2kΩ
10kΩ
R3
100kΩ
OFFSET
ADJUST
0.1µF
PEAK
ADJUST
10kΩ
-15V
2kΩ
R2
R3
GAIN = ------- = X = ---------------------------------R1
R1 + R2 + R3
BW (-3dB) = 4.5MHz
SR = 9V/µs
0.05µF
2

X+X
R3 =  ----------------  R1
 1–X 
5kΩ
R2
FORX = 0.5 ------------- = ------10kΩ
R1
 0.75 
R3 = 10kΩ  ----------  = 15kΩ
0.5
20Vp-p Input BW(-3dB) = 290kHz, DCOutput (Avg) = 3.2V
(A) SMALL SIGNAL RESPONSE
50mV/Div and 200ns/Div
OUTPUT
0
Top Trace: Output; 50mV/Div and 200ns/Div
Bottom Trace: Input; 50mV/Div and 200ns/Div
INPUT
0
FIGURE 34. SINGLE SUPPLY, ABSOLUTE VALUE, IDEAL FULL
WAVE RECTIFIER WITH ASSOCIATED WAVEFORMS
+15V
7
RS
3
1MΩ
0.01µF
+
6
CA3140
2
-
NOISE VOLTAGE
OUTPUT
(B) INPUT-OUTPUT DIFFERENCE SIGNAL
SHOWING SETTLING TIME
(measurement made with Tektronix 7A13 differential amplifier)
4
0.01µF
30.1kΩ
-15V
BW (-3dB) = 140kHz
TOTAL NOISE VOLTAGE
(REFERRED TO INPUT ) = 48µV TYP.
Top Trace: Output Signal; 5V/Div and 5µs/Div
Center Trace: Difference Signal; 5mV/Div and 5µs/Div
Bottom Trace: Input Signal; 5V/Div and 5µs/Div
1kΩ
FIGURE 35. TEST CIRCUIT AMPLIFIER (30dB GAIN) USED FOR
WIDEBAND NOISE MEASUREMENT
FIGURE 36. SPLIT SUPPLY VOLTAGE FOLLOWER TEST CIRCUIT AND ASSOCIATED WAVEFORMS
2-142