LEM CT0.1-P

Current Transducers CT 0.1 .. 0.4-P
For the electronic measurement of small currents: AC,DC, mixed,
with a galvanic isolation between the primary circuit and the
secondary circuit.
IPN = ± 100..400 mA
VOUT = ± 5 V
Electrical data
Primary nominal
current rms
IPN (mA)
Primary current,
measuring range
IPM (mA)
100
200
400
VC
IC
RIS
VOUT
ROUT
RL
CL
± 180
± 360
± 720
Type
RoHS since
date code
CT 0.1-P
CT 0.2-P
CT 0.4-P
Supply voltage (± 5 %)
Current consumption
Isolation resistance @ 500 VDC
Output voltage (Analog) @ ± IPN, RL= 10kΩ , TA=25°C
Output internal resistance
Load resistance
Capacitive loading
46129
46054
46234
± 15
± 35
> 500
±5
< 51
≥ 10
≤5
V
mA
MΩ
V
Ω
kΩ
nF
ε
L
TCVOUT
VOE
VOH
TCVOE
tr
BW
Accuracy (excluding offset) @ IPN, TA = 25°C, RL = 10kΩ
Linearity error (0 .. ± IPN)
Temperature coefficient of VOUT (of reading)
Eletrical offset voltage @ IP = 0, TA = 25°C
Hysteresis offset voltage
@ IP = 0; after an excursion of 1 x IPN
@ IP = 0; after an excursion of 100 x IPN
Temperature coefficient of VOE @ -20..+85°C CT 0.1-P
CT 0.2-P
CT 0.4-P
Response time to 80% of IPN step
90% of IPN step
Frequency bandwidth (- 3 dB)
CT 0.1-P
CT 0.2-P
CT 0.4-P
<±1
%of IPN
< ± 0.5 %of IPN
< ± 0.05 %/K
< ± 50
mV
<±2
mV
< ± 20
mV
<±4
mV/K
<±3
mV/K
<±2
mV/K
≤ 20
ms
≤ 60
ms
DC .. 7000 Hz
DC .. 11000 Hz
DC .. 18000 Hz
General data
TA
TS
dCp
dCl
CTI
m
Ambient operating temperature
Ambient storage temperature
Creepage distance
Clearance distance
Comparative tracking index (Group IIIa)
Mass
Standards
• DC & AC earth leakage current
transducer using a flux-gate
principle
• PCB mounting
• ±15V power supply
• ±5V output @ IPN
• Insulated plastic case recognized
according to UL94-V0.
Advantages
Accuracy-Dynamic performance data
X
Features
- 20 .. + 85 °C
- 25 .. + 85 °C
> 5.5
mm
> 5.5
mm
> 220
25
g
EN 50178: 1997
• Small size
• Bandwidth : DC .. up to 18kHz
• Response time better than 60 ms
• Cost effective, compact
alternative to classical RCDs
(Residual Current Device)
Applications
• Earth leakage detection in
transformerless solar inverters
• 1st human contact protection of
PV arrays
• Failure detection in power sources
• Symmetrical fault detection
(e.g. after motor inverter)
• Current leakage detection in
stacked DC sources
• Single phase or three phase
differential current measurement up
to ±30A per wire (DC or AC)
Application Domain
• Industrial
copyright protected
Page 1/3
061017/9
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
Current Transducer CT 0.1 .. 0.4-P
Isolation characteristics
Vb
Vb
Vd
Ve
Vw
Rated isolation voltage rms
with IEC 61010-1 standard and following conditions
- Single insulation
- Over voltage category III
- Pollution degree 2
- Heterogeneous field
Rated isolation voltage rms
with EN 50178 standard and following conditions
- Reinforced insulation
- Over voltage category III
- Pollution degree 2
- Heterogeneous field
Rms voltage for AC isolation test, 50 Hz, 1 min
Partial discharge extinction voltage rms @ 10pC
Impulse withstand voltage 1.2/50µs
150
V rms
250
V rms
2.5
> 1.2
6
kV
kV
kV
If insulated cable is used for the primary circuit, the
voltage category could be improved with the following table :
Cable insulation (primary)
Category
HAR 03
300V CAT III
HAR 05
400V CAT III
HAR 07
500V CAT III
Page 2/3
061017/9
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
Dimensions CT 0.1 .. 0.4-P (in mm. 1 mm = 0.0394 inch)
20
11.0
30
Ø
fø11
11
30
M GND -Vcc+Vcc
12.6
17.8
5±2
-Vcc +Vcc
2-F 2
2-Ø2 (NC)
4- 0.7
5±2
0. 5
0.5±0.3
M GND
4- 0.7
± 0.3
17.8
± 0.3
I
+Vcc
Ip flux-gate
DC
M
transformer
AC
GND
+Vcc
+Vcc
Vcc
-Vcc
GND
10.5
11
4.3
10. 5
−Vcc
20.3
GND
M
M
2-F 5
2-Ø5 ± 0.3
RL
Vout
Mechanical characteristics
• General tolerance
(Unless otherwise specified in
• Aperture for primary conductor
• Connection of secondary
Recommended PCB hole
• PCB fixation
Recommended PCB hole
± 1 mm
the above drawings.)
Ø11 mm
4 pins 0.7 x 0.7 mm2
1.2 mm
2 pins Ø2 mm
2.2 mm
Safety
This transducer must be used in electric/electronic equipment
with respect to applicable standards and safety requirements
in accordance with the following manufacturer's operating
instructions.
Remarks
Caution, risk of electrical shock
• VOUT is positive when IP flows in the direction of the
arrow.
• This transducer induces into the primary circuit a
square wave of 500Hz. This voltage can induce an AC
current in the primary if the primary impedance is low.
• Primary impedance ≥10Ω CT0.1-P CT0.2-P CT0.4-P
VOUT by induced current
≤±0.5% ≤±0.4% ≤±0.2% of IPN
• Temperature of the primary conductor should not
exceed 100°C.
When operating the transducer, certain parts of the module can
carry hazardous voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious
damage.
This transducer is a built-in device, whose conducting parts
must be inaccessible after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
Page 3/3
061017/9
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com