DKE10 10W DC-DC Regulated Dual Output Converter series Features : 2:1 wide input range 4:1 wide input range(option) 1000VDC I/O isolation 3000VDC I/O isolation(option) Built-in EMI filter Protections: Short circuit / Overload Cooling by free air convection Six-sided shield metal case 100% burn-in test Low cost / High reliability Approvals: FCC / CE 2 years warranty SPECIFICATION ORDER NO. DKE10A- DKE10B- DKE10C- DKE10A- DKE10B- DKE10C- DKE10A- DKE10B- DKE10C- DKE10A- DKE10B- DKE10C05 05 05 12 12 12 15 15 15 24 24 24 5V 12V 15V 24V DC VOLTAGE CURRENT RANGE 100 ~ 1000mA OUTPUT RIPPLE & NOISE (max.) Note.2 50mVp-p LINE REGULATION Note.3 0.3% LOAD REGULATION Note.4 0.5% DC CURRENT 60mVp-p 80mVp-p Full load A: 1100mA B: 530mA C: 270mA No load A: 30mA C: 8mA B: 16mA 83% 82% 80% 80% FILTER PROTECTION Pi network Fuse recommended OVER CURRENT 160% ~ 250% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed PROTECTION 82% 81% 85% All output equipped with short circuit SHORT CIRCUIT Protection type : Hiccup mode, recovers automatically after fault condition is removed WORKING TEMP. -25 ~ +71 WORKING HUMIDITY 20% ~ 90% RH non-condensing (Refer to output load derating curve) -25 ~ +105 , 10 ~ 95% RH 0.03% / (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE OTHERS 60mVp-p A: 9 ~ 18VDC B: 18 ~ 36VDC C: 36 ~ 72VDC 80% 78% 82% 80% 81% EFFICIENCY (Typ.) EMC 21 ~ 210mA 250KHz min. SWITCHING FREQUENCY VOLTAGE RANGE (Note. 5) 33.3 ~ 333mA 2.0% VOLTAGE ACCURACY INPUT 42 ~ 420mA 10W RATED POWER I/P-O/P:1KVDC I/P-O/P: 100M Ohms / 500VDC / 25 / 70% RH EMI CONDUCTION & RADIATION EMS IMMUNITY MTBF DIMENSION Compliance to EN55022 Class B, FCC part 15 Class B Compliance to EN61000-4-2,3,4,5,6,8, light industry level, criteria A 500Khrs min. MIL-HDBK-217F(25 ) WEIGHT 32g 50.8*25.4*11.2mm or 2"*1"*0.44" inch (L*W*H) Derating Curve Pin Configuration Mechanical Specification Unit: mm 50.8 11.27 4 2 5 2.5 BOTTOM VIEW 10.2 10.2 5.1 10.1 25.4 3 1 1.0 5.8 Pin No. Output 1 2 3 4 5 + Vi n - Vi n + Vo u t COM - Vo u t 100 LOAD (%) 20.3 2.5 15.3 80 + 0.2/-0.1 -25 0 25 50 60 71 Ta ( NOTE 100 ) 1.All parameters are specified at normal input, rated load, 25 70% RH Ambient. 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 3.Line regulation is measured from low line to high line at rated load. 4.Load regulation is measured from 10% to 100% rated load. 5.Please prevent the converter from operating in overload or short circuit condition for more than 30 seconds. File Name:DKE10-SPEC 2008-05-20