ETC G3MC-202P

9
Solid State Relay
G3MC
Compact, Low-cost Fail-safe SSR that
Switches up to 2 Amps
1 Unlike conventional solid-state devices,
Omron’s new fail-safe technology
eleminates the need for external fuse or
safety circuitry in many applications
1 Smaller footprint (approximately 20%
smaller than G3MB) is ideal for close
PCB mounting applications
èòå
1 Built in snubber circuit
1 VDE versions available
Ordering Information
To Order: Select the part number and add the desired coil voltage rating, (e.g., G3MC-101P-DC12).
Isolation
Zero-cross function
Built-in snubber
circuit
Rated output load
Rated input voltage
Part number
Phototriac
Yes
Yes
1 A at 100 to 120 VAC
(75 to 132 VAC)
5 VDC
G3MC-101P
12 VDC
24 VDC
No
5 VDC
G3MC-101PL
12 VDC
24 VDC
Yes
2 A at 100 to 120 VAC
(75 to 132 VAC)
5 VDC
G3MC-102P
12 VDC
24 VDC
No
5 VDC
G3MC-102PL
12 VDC
24 VDC
Yes
1 A at 100 to 240 VAC
(75 to 264 VAC)
5 VDC
G3MC-201P
12 VDC
24 VDC
No
5 VDC
G3MC-201PL
12 VDC
24 VDC
Yes
2 A at 100 to 240 VAC
(75 to 264 VAC)
5 VDC
G3MC-202P
12 VDC
24 VDC
No
5 VDC
12 VDC
24 VDC
Note: VDE versions available. Contact your local Omron representitive
G3MC-202PL
G3MC
G3MC
Specifications
3 RATINGS (AMBIENT TEMPERATURE 25°C)
Input
Rated voltage
Operating voltage
Impedance
Voltage levels
Must operate voltage
Must dropout voltage
1 VDC min.
5 VDC
4 to 6 VDC
300Ω ±20%
4 VDC max.
12 VDC
9.6 to 14.4 VDC
800Ω ±20%
9.6 VDC max.
24 VDC
19.2 to 28.8 VDC
1.6kΩ ±20%
19.2 VDC max.
Note:
Each model has 5-VDC, 12-VDC, and 24-VDC input versions.
Output
Part number
Applicable load
Rated load voltage
Load voltage range
Load current
Surge current
G3MC-101P(L)
100 to 120 VAC
75 to 132 VAC
0.1 to 1 A
8 A (60 Hz, 1 cycle)
G3MC-201P(L)
100 to 240 VAC
75 to 264 VAC
G3MC-102P(L)
100 to 120 VAC
75 to 132 VAC
0.1 to 2 A
30 A (60 Hz, 1 cycle)
G3MC-202P(L)
100 to 240 VAC
75 to 264 VAC
3 CHARACTERISTICS
Item
G3MC-101P /
G3MC-102P
G3MC-101PL /
G3MC-102PL
G3MC-201P /
G3MC-202P
G3MC-201PL /
G3MC-202PL
Operate time
1/2 of load power source
cycle + 1 ms
1 ms max.
1/2 of load power source
cycle + 1 ms
1 ms max.
Release time
1/2 of load power source cycle + 1 ms)
Output ON voltage drop
1.6 V (RMS) max.
Leakage current
1 mA max. (at 100 VAC)
Insulation resistance
1,000 MΩ min. (at 500 VDC)
Dielectric strength
2,500 VAC, 50/60 Hz for 1 min
Vibration resistance
Malfunction: 10 to 55 Hz, 0.75-mm double amplitude
Shock resistance
Malfunction: 1,000 m/s2 (approx. 100G)
Ambient temperature
Operating: --30°C to 80°C (with no icing or condensation)
Storage:
--30°C to 100°C (with no icing or condensation)
Approved standards
UL508 File No. E64562, CSA C22.2 (No. 14, No. 950) File No. LR35535, EN60950 File No. 5925UG
Ambient humidity
Operating: 45% to 85%
Weight
Approx. 2.5 g
1.5 mA max. (at 200 VAC)
7
G3MC
G3MC
Engineering Data
3 G3MC-101P(L), G3MC-201P(L)
Load Current vs. Ambient
Temperature Characteristics
Inrush Current Resistivity
Load current (A)
Inrush current (A. Peak)
Non-repetitive (Keep the inrush current to
half the rated value if it occurs repeatedly.)
Energizing time (ms)
Ambient temperature (°C)
3 G3MC-102P(L), G3MC-202P(L)
Load Current vs. Ambient
Temperature Characteristics
Inrush Current Resistivity
Non-repetitive (Keep the inrush current to
half the rated value if it occurs repeatedly.)
Inrush current (A. Peak)
Load current (A)
2.5
2.0
1.5
1.0
0.5
0
--30 --20
0
20 25
40
60
Ambient temperature (°C)
8
80
100
30
20
10
0
10
30 50 100 200
500 1000
Energizing time (ms)
5000
G3MC
G3MC
Dimensions
Unit: mm (inch)
G3MC-101P
G3MC-101PL
G3MC-201P
G3MC-201PL
PCB Dimensions
(Bottom View)
Four, 1.0-dia. holes
4.5 max.
24.5 max.
13.5 max.
Terminal Arrangement
(Bottom View)
G3MC-102P
G3MC-102PL
G3MC-202P
G3MC-202PL
PCB Dimensions
(Bottom View)
4.50 max.
(0.18)
24.5 max.
(0.97)
2.54
(0.10)
Four, 1.0
(0.04) dia. holes
2.54
(0.10)
0.8.
(0.03)
20.5 max.
(0.81)
4-- 3+
2
Terminal Arrangement
(Bottom View)
1
(--)4 3(+)
3.5
(0.14)
Four, 1.6
(0.06)
2.54
(0.10)
2.54
(0.10)
10.16
(0.40)
Four, 0.7
(0.03)
0.25
(0.01)
INPUT
2
1
LOAD
1.2
(0.05)
7.62
(0.30)
9
G3MC
G3MC
Precautions
3 GENERAL PRECAUTIONS
Do not touch the terminals of the SSR while power is being
supplied to the SSR. The terminals are charged with the power, and
an electric shock may be received by touching the terminals.
closely, make sure that the Units are properly ventilated by taking ambient temperature rises into consideration. If Units are closely
mounted and used in places with no ventilation, the load current of
each Unit must be 1/2 of the rated load current.
The built-in capacitor may have a residual voltage after the SSR is
turned off. Be sure to discharge the residual voltage before
touching the terminals of the SSR, otherwise an electric shock may
be received.
3 MOUNTING
1.
Make sure that no excessive voltage or current is imposed on
or flows to the input or output circuit of the SSR, otherwise
the SSR may malfunction or burn.
2.
Solder the terminals of the SSR properly under the required
soldering conditions. The SSR may be abnormally heated and
burn if power is supplied to the terminals soldered incorrectly.
3.
Do not short-circuit the load of the SSR while power is supplied
to the SSR. Do not short-circuit the power supply through the
SSR. The SSR may be damaged, malfunction, or burn if the
load or power supply is short-circuited.
3 CORRECT USE
The terminals of the SSR are highly heat-conductive. Each terminal
must be soldered within 10 s at 260°C or within 5 s at 350°C.
The SSR is of a thin-profile construction. To maintain the vibration resistance of the SSR, make sure that the space between the SSR and
PCB is 0.1 mm maximum. Lifting of the PCB can be prevented by setting the hole diameter of the PCBs on both sides slightly smaller than
the actual terminal dimension.
Select the model without the zero-cross function when using the Unit
for phase control output.
The casing works as a heat sink. When mounting two or more Units
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
9
OMRON ELECTRONICS, INC.
OMRON CANADA, INC.
One East Commerce Drive
Schaumburg, IL 60173
885 Milner Avenue
Scarborough, Ontario M1B 5V8
1-800-55-OMRON
416-286-6465
Cat. No. GC RLY7
01/00
Specifications subject to change without notice.
Printed in U.S.A.