GPFC160 Commercial 160 Watt Global Performance Switchers FEATURES: • • • • • • 3.0 watts/cu.in. power density Compact size (4.5" x 7.0" x 1.7"; meets 1U height) Power factor corrected to IEC 1000-3-2; Class A Less than 300 µA leakage EMI compliance to CISPR22, FCC Class B Commercial Approved to UL1950, IEC950, EN60950 and CSA 22.2 No. 950 • 2-year warranty marked to LVD • SPECIFICATIONS: Ac Input 85-264 Vac, 47-63 Hz single phase. Input Current Maximum input current 2.3 A at 90 Vac, 60 Hz with full rated load. Input current harmonic content meets the requirements of IEC1000-3-2. Hold-upTime 25 ms minimum from loss of ac input at full load, nominal line (115 Vac). Output Power Total regulation is the maximum deviation from the nominal voltage for all steady-state loading conditions. Each individual output is to be used within its specified limits of that output. Peak ratings are for 60 s maximum duration, 10% duty cycle. Overload Protection Fully protected against short circuit and output overload. Short circuit protection is cycling type power limit. Recovery after fault is automatic. Output Noise 0.5% rms, 1% pk-pk, 20 MHz Bandwidth, differential mode. Measured with noise probe directly across output terminals of the power supply. Transient Response 500 ms typical response time for return to within 0.5% of final value for a 50% load step change, ∆i/∆t< 0.2 A/ms. Maximum voltage deviation is 3.5%. Remote Sense Provided as a standard feature. Capable of compensating for 0.25 V total of cabling losses. Overvoltage Protection Built in on all models. OVP crowbar reduces output voltage below nominal rating in less than 50 ms. Voltage Adjustment Main output ±5%. 62 Input Protection Internal ac fuse provided on all models. Fuse does not blow on overload or short circuit—fuse blows only if catastrophic failure occurs in the unit. Inrush Current Inrush 240 Vac is less than 37 A, averaged over the first ac half-cycle under cold start conditions. Limiting provided by internal thermistors. Fan Output An additional 12 Vdc, 250 mA output suitable for powering a dc fan is included in all models. The output is protected by an internal PTC in the event of an overload. Thermal Shutdown Provided as a standard feature. Designed to protect the unit from prolonged over temperature. Power Fail TTL or CMOS compatible output goes low (<0.5 V) 8 ms before output voltage drops more than 4% below nominal voltage upon loss of ac power. The signal is factory set to trip when input power can no longer sustain the output. Temperature Coefficient 0.03%/°C typical on all outputs. EMI/EMC Compliance All models include built-in EMI filtering to meet the following emissions requirements: EMI SPECIFICATIONS Conducted Emissions Static Discharge RF Field Susceptibility Fast Transients/Bursts Surge Susceptibility COMPLIANCE LEVEL EN55022 Class B; FCC Class B EN61000-4-2, 6 kV contact, 8 kV air EN61000-4-3, 3 V/meter EN61000-4-4, 2 kV, 5 kHz EN61000-4-5, 1 kV diff., 2 kV com. Commercial Safety Approved to UL1950, CSA22.2 950, IEC950, and EN60950. UL file #E135803 commercial; CSA #LR46516. The output(s) are intended for safety earthed Signal Output and Intermediate Circuits only. All dc outputs are SELV under normal and single fault conditions. Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com GPFC160 Commercial 160 Watt Single Output Output No. Output Output Maximum (A) Output Peak (B) OVP Setpoint Ripple & Noise GPFC160-5 1 5.1 V 25 A 31.3 A 6.2 ± 0.6 V 1% GPFC160-12 1 12 V 11.7 A 13.3 A 14 ± 1.1 V 1% GPFC160-15 1 15 V 9.3 A 10.7 A 18.5 ± 1.5 V 1% GPFC160-24 1 24 V 5.8 A 6.7 A 28 ± 2.5 V 1% GPFC160-28 1 28 V 5A 5.7 A 34 ± 2.8 V 1% GPFC160-48 1 48 V 2.9 A 3.4 A 55 ± 4.0 V 1% Model A. Output rating with unrestricted convection cooling. B. Output rating with 26 cfm airflow. GPFC160 MECHANICAL SPECIFICATIONS Environmental Specification Operating Non-operating Temperature (A) 0 to 50oC -40 to +85oC 0 to 95% RH 0 to 95% RH 20 gpk 40 gpk Humidity (A) Shock (B) Altitude Vibration (C) -500 to 10,000 ft -500 to 40,000 ft 1.5 grms, 0.003 g2/Hz 5 grms, 0.026 g2/Hz A. Units should be allowed to warm up/operate under non-condensing conditions before application of power. Derated output current and total output power by 2.5% per 50ºC. B. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating. C. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes, total 6 shocks. Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com 63