POWERDYNAMICS HGN-375

HGN-375
IEC 60320 INLET SOCKET WITH SWITCH, SINGLE AND DOUBLE FUSE HOLDER,
FLANGE MOUNT
MECHANICAL DIMENSIONS (Unit: mm)
52.0
67.0
Use only with a 250V Fuse
Employer uniqement avec
un fusible de 250V
O
33.5
40.0+- 0.2
0.8 TYP.
FEATURES
The HGN-375 protects electronic equipment from common
and differential mode line interference in the range of
10KHz up to 30MHz. This “combi-unit” is equipped with
IEC connector, fuse holder for one or two 5 x 20 mm fuses,
2 pole on/off switch and fully enclosed metal housing.
60.5
These filters are also available for Medical equipment
with low leakage current. HGN-375 series filters are high
performance filters and have been designed to bring various
medical equipments into compliance with EN55011 and
FCC Part 15J, Class B conducted emissions limits.
28.5
6.30 TYP.
APPLICATIONS
57.5
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
TECHNICAL DATA
• Rated Voltage: 125/250VAC
• Rated Current: 1A, 2A, 4A, 6A, 10A
• Power Line Frequency: 50/60Hz
• Max. Leakage Current each
Line to Ground:
@ 250VAC 50Hz: 0.5mA, max
@ 250VAC 50Hz: 2µA*, max
• Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
• Temperature Range: -25C to +85C
45.0
6.0
40.0+- 0.2
29.5
4x R0.5
61.5
2x M3
* Medical application
Specifications subject to change without notice. Dimensions (mm). See Appendix A for
recommended power cord. See PDI full line catalog for detailed specifications on power cords.
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: [email protected] • www.powerdynamics.com
79
HGN-375 Series Example & Ordering Code
HGN-375 - 1
CURRENT RATING (A):
=
=
=
=
=
SCHEMATIC:
M - F2
1
2
4
6
10
STANDARD TYPE
=
WITHOUT C(Y); C(X) ONLY
=M
FUSE OPTION:
BLANK
1 FUSE (5X20MM), 6.3/0.25 QUICK CONNECT
= F1
2 FUSE (5X20MM), 6.3/0.25 QUICK CONNECT
= F2
Attenuation Tables & Schematics
Non-Medical Applications
Insertion loss in dB (50 Ohm circuit)
40
37
22
19
17
51
41
30
26
30
46 35
42 37
32 32
29 29
51 79
31
29
30
29
80
21
21
23
25
51
3 10 7 16 60 75
5 12 10 11 60 73
8 10 16 19 40 67
5 8 15 16 30 51
2 9 13 17 26 33
89
82
84
79
53
80
82
80
80
60
39
39
40
50
40
E
P
FUSE
L(mH)
FUSE
L(mH)
2200pF
E'
2200pF
LOAD
38
35
20
17
15
N'
0.01 F
33
30
17
13
6
0.033 F
24
16
10
8
5
L(mH)
FUSE
0.068 F
10.3mA
4.6mA
2.5mA
1.2mA
0.8mA
LINE
1A
2A
4A
6A
10A
N
1M
Current
L
Comm. Mode(L-G) MHz
Diff. mode(L-L) MHz
Rating Value .01 .05 .1 .15 .5 1 5 10 30 .01 .05 .1 .15 .5 1 5 10 30
P'
Medical Applications
80
32
30
18
13
13
38
35
20
17
16
41
36
22
19
19
51
41
30
26
25
48 36
42 37
32 32
29 29
28 29
31
30
30
29
29
22
21
22
24
24
2 10 8 15 60 75
5 12 10 10 60 73
8 10 17 19 40 67
5 7 15 17 30 51
5 5 15 18 30 51
84
82
84
80
79
80
83
80
80
80
39
36
33
41
51
E
P
FUSE
L(mH)
E'
LOAD
23
18
10
8
8
N'
0.01 F
10.3mA
4.6mA
2.5mA
1.2mA
0.8mA
N
0.033 F
1A
2A
3A
4A
6A
Comm. Mode(L-G) MHz
Diff. mode(L-L) MHz
.01 .05 .1 .15 .5 1 5 10 30 .01 .05 .1 .15 .5 1 5 10 30
0.068 F
L
Value
LINE
Current
Rating
1M
Insertion loss in dB (50 Ohm circuit)
P'
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: [email protected] • www.powerdynamics.com