HRPG-450 450W Single Output with PFC Function series Features : Universal AC input / Full range Built-in active PFC function, PF>0.95 High efficiency up to 89.5% Withstand 300VAC surge input for 5 seconds Protections: Short circuit / Overload / Over voltage / Over temperature Built-in constant current limiting circuit Built-in cooling Fan ON-OFF control Built-in DC OK signal Built-in remote ON-OFF control Stand by [email protected] Built-in remote sense function No load power consumption<0.5W (Note.7) 5 years warranty SPECIFICATION MODEL OUTPUT HRPG-450-3.3 HRPG-450-5 HRPG-450-7.5 HRPG-450-12 HRPG-450-15 HRPG-450-24 HRPG-450-36 HRPG-450-48 DC VOLTAGE 3.3V 5V 7.5V 12V 15V 24V 36V RATED CURRENT 90A 90A 60A 37.5A 30A 18.8A 12.5A 9.5A CURRENT RANGE 0 ~ 90A 0 ~ 90A 0 ~ 60A 0 ~ 37.5A 0 ~ 30A 0 ~ 18.8A 0 ~ 12.5A 0 ~ 9.5A RATED POWER 297W 450W 450W 450W 450W 451.2W 450W 456W RIPPLE & NOISE (max.) Note.2 80mVp-p 80mVp-p 100mVp-p 120mVp-p 150mVp-p 150mVp-p 240mVp-p 240mVp-p VOLTAGE ADJ. RANGE 4.3 ~ 5.8V 2.0% 6.8 ~ 9V 2.0% 10.2 ~ 13.8V 1.0% 13.5 ~ 18V 1.0% 21.6 ~ 28.8V 1.0% 28.8 ~ 39.6V 1.0% 40.8 ~ 55.2V 1.0% VOLTAGE TOLERANCE Note.3 2.8 ~ 3.8V 2.0% LINE REGULATION 0.5% 0.5% 0.5% 0.3% 0.3% 0.2% 0.2% 0.2% LOAD REGULATION 1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% SETUP, RISE TIME 1000ms, 100ms/230VAC HOLD UP TIME (Typ.) 16ms/230VAC 120 ~ 370VDC POWER FACTOR (Typ.) PF>0.95/230VAC EFFICIENCY (Typ.) 80% 83% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 5A/115VAC 35A/115VAC 2.4A/230VAC 70A/230VAC LEAKAGE CURRENT <1.5mA / 240VAC OVERLOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE FUNCTION 2500ms, 100ms/115VAC at full load 16ms/115VAC at full load VOLTAGE RANGE Note.5 85 ~ 264VAC 47 ~ 63Hz FREQUENCY RANGE INPUT 48V PF>0.99/115VAC at full load 86.5% 88% 89% 88% 105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 6 ~ 7V 9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V 3.96 ~ 4.62V 89% 89.5% 41.4 ~ 48.6V 57.6 ~ 67.2V Protection type : Shut down o/p voltage, re-power on to recover 90 5 (70 5 5V only) (TSW1 : detect on heatsink of power transistor) ; 90 5 (TSW2 : detect on heatsink of power doide ) 5V STANDBY Protection type : Shut down o/p voltage, recovers automatically after temperature goes down 5VSB : [email protected] ; tolerance 5%, ripple : 50mVp-p(max.) DC OK SIGNAL PSU turn on : 3.3 ~ 5.6V ; PSU turn off : 0 ~ 1V REMOTE CONTROL RC+ / RC-: 4 ~ 10V or open = power on ; 0 ~ 0.8V or short = power off FAN CONTROL (Typ.) Load 20 10% or RTH2 50 WORKING TEMP. -40 ~ +70 Fan on (Refer to "Derating Curve") 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH TEMP. COEFFICIENT 0.03%/ (0 ~ 50 ) VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 4) EMC EMISSION EMC IMMUNITY OTHERS I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A MTBF 130.5K hrs min. DIMENSION 218*105*41mm (L*W*H) 1.19Kg; 12pcs/15.3Kg/0.82CUFT PACKING NOTE UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC MIL-HDBK-217F (25 ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 5. Derating may be needed under low input voltages. Please check the derating curve for more details. 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. No load power consumption<0.5W when RC- & RC+ (CN100 pin1,2) 0 ~ 0.8V or short. File Name:HRPG-450-SPEC 2011-08-09 HRPG-450 450W Single Output with PFC Function Mechanical Specification Case No. 995A Unit:mm 32.8 20.75 152.4 series O/P 11 1 2 4 I/P 105 3 63.5 FAN 9.2 Air flow direction 6 4-M4 L=5 3 1 7 2 8 CN100 10 2 218 152.4 32.8 18max. LED (Vo ADJ.)SVR1 8.2 5 1 12.5 41 18 12max. AC Input Terminal Pin No. Assignment Pin No. 1 2 3 8-M4 L=4 (Both Sides) Connector Pin No. Assignment(CN100) : HRS DF11-8DP-2DS or equivalent DC Output Terminal Pin No. Assignment Assignment AC/L AC/N FG Pin No. 1~3 4~6 Assignment RC+ RCAUX AUXG Pin No. 1 2 3 4 Assignment -V +V Pin No. 5 6 7 8 Assignment DC-OK GND +S -S Mating Housing HRS DF11-8DS HRS DF11-**SC or equivalent or equivalent Block Diagram PMW fosc : 70KHz ACTIVE INRUSH CURRENT LIMITING EMI FILTER I/P Terminal RECTIFIERS & PFC AUX POWER RECTIFIERS & FILTER AUX AUXG +S POWER SWITCHING RECTIFIERS & FILTER +V -V -S DETECTION CIRCUIT O.L.P. O.T.P. FG DC OK O.T.P. PFC CONTROL PWM CONTROL Derating Curve O.V.P. RC+ REMOTE CONTROL RC- Output Derating VS Input Voltage 100 125 90 100 80 70 LOAD(%) LOAD (%) 80 50 20 -40 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 70 (HORIZONTAL) 60 50 40 85 100 125 135 155 264 INPUT VOLTAGE (V) 60Hz File Name:HRPG-450-SPEC 2011-08-09 HRPG-450 450W Single Output with PFC Function series Function Description of CN100 Pin No. Function Description 1 RC+ Turns the output on and off by electrical or dry contact between pin 2 (RC-), Short: Power OFF, Open: Power ON. RC- Remote control ground. 2 Auxiliary voltage output, 4.75~5.25V, referenced to pin 4(AUXG). The maximum load current is 0.3A. This output has the built-in oring 3 AUX diodes and is not controlled by the "remote ON/OFF control". 4 5 6 7 8 AUXG Auxiliary voltage output ground. The signal return is isolated from the output terminals (+V & -V). DC-OK DC-OK Signal is a TTL level signal, referenced to pin6(DC-OK GND). High when PSU turns on. GND This pin connects to the negative terminal(-V). Return for DC-OK signal output. Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to +S minimize noise pick-up effect. The maximum line drop compensation is 0.5V. -S Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V. Function Manual 1.Remote Sense The remote sensing compensates voltage drop on the load wiring up to 0.5V. CN100 CN100 2 1 8 7 2 RC- RC+ 1 AUXG AUX GND DC-OK 8 +S (Pin7) - + LOAD Fig 1.1 -S +S 7 -S (Pin8) Sense lines should be twisted in pairs 2.DC-OK Signal DC-OK signal is a TTL level signal. High when PSU turns on. Between DC-OK(pin5) and GND(pin6) CN100 Output Status CN100 3.3 ~ 5.6V ON 0 ~ 1V OFF 2 1 8 7 2 RC- RC+ 1 AUXG AUX GND DC-OK 8 -S +S 7 Fig 2.1 3.Remote Control The PSU can be turned ON/OFF by using the "Remote Control" function. Between RC+(pin1) and RC-(pin2) Output Status SW ON (Short) OFF SW OFF (Open) ON CN100 2 1 8 7 1 2 CN100 RC- RC+ AUXG AUX GND DC-OK 8 -S +S 7 SW Fig 3.1 File Name:HRPG-450-SPEC 2011-08-09