SONY ICX069AKB

ICX069AKB
Diagonal 4.5mm (Type 1/4) CCD Image Sensor for PAL Color Video Cameras
Description
The ICX069AKB is an interline CCD solid-state
image sensor suitable for PAL color video cameras.
High resolution is achieved through the use of Ye, Cy,
Mg, and G complementary color mosaic filters. At the
same time, high sensitivity and low dark current are
achieved through the adoption of HAD (HoleAccumulation Diode) sensors.
This chip features a field period readout system and
an electronic shutter with variable charge-storage
time.
Also, this outline is miniaturized by using original
package.
13 pin PCA (Ceramic)
AAAAA
AAAAA
AAAAA
AAAAA
AAAAA
Pin 1
Features
• Maximum package dimensions: φ8mm
• High resolution, high sensitivity and low dark current
• Horizontal register: 3.6 to 5.0V drive
• No voltage adjustment
(Reset gate and substrate bias are not adjusted.)
• Low smear
• Excellent antiblooming characteristics
• Continuous variable-speed shutter
• Ye, Cy, Mg, and G complementary color mosaic filters on chip
Device Structure
• Image size:
• Number of effective pixels:
• Total number of pixels:
• Interline CCD image sensor
• Chip size:
• Unit cell size:
• Optical black:
• Number of dummy bits:
• Substrate material:
2
V
3
Pin 8
H
12
40
Optical black position
(Top View)
Diagonal 4.5mm (Type 1/4)
752 (H) × 582 (V) approx. 440K pixels
795 (H) × 596 (V) approx. 470K pixels
4.47mm (H) × 3.80mm (V)
4.85µm (H) × 4.65µm (V)
Horizontal (H) direction: Front 3 pixels, rear 40 pixels
Vertical (V) direction:
Front 12 pixels, rear 2 pixels
Horizontal 22
Vertical 1 (even fields only)
Silicon
Sony reserves the right to change products and specifications without prior notice. This information does not convey any license by
any implication or otherwise under any patents or other right. Application circuits shown, if any, are typical examples illustrating the
operation of the devices. Sony cannot assume responsibility for any problems arising out of the use of these circuits.
–1–
E94907D99
ICX069AKB
VOUT
GND
NC
Vφ1
Vφ2
Vφ3
Vφ4
Block Diagram and Pin Configuration
(Top View)
7
6
5
4
3
2
1
Vφ4
Vφ3
Hφ2
Vertical Register
1
Cy
Ye
Cy
Ye
Mg
G
Mg
G
Ye
Cy
Ye
G
Mg
G
Mg
Cy
Ye
Cy
Ye
G
Mg
G
Vφ1
Note)
11
4
5
NC
10
11
12
13
VDD
φSUB
VL
RG
Hφ1
Hφ2
Note)
9
RG
10
VL
Horizontal Register
8
Hφ1
12
3
Cy
Mg
13
2
Vφ2
6
: Photo sensor
9
7
8
φSUB
GND
VOUT
VDD
Pin Description
Pin No.
Symbol
Description
Pin No.
Description
Symbol
1
Vφ4
Vertical register transfer clock
8
VDD
Supply voltage
2
Vφ3
Vertical register transfer clock
9
φSUB
Substrate clock
3
Vφ2
Vertical register transfer clock
10
VL
Protective transistor bias
4
Vφ1
Vertical register transfer clock
11
RG
Reset gate clock
5
NC
12
Hφ1
Horizontal register transfer clock
6
GND
GND
13
Hφ2
Horizontal register transfer clock
7
VOUT
Signal output
Absolute Maximum Ratings
Item
Ratings
Unit
–0.3 to +40
V
VDD, VOUT – GND
–0.3 to +18
V
VDD, VOUT – φSUB
–30 to +9
V
Vφ1, Vφ2, Vφ3, Vφ4 – GND
–15 to +16
V
to +10
V
Voltage difference between vertical clock input pins
to +15
V
Voltage difference between horizontal clock input pins
to +16
V
Hφ1, Hφ2 – Vφ4
–16 to +16
V
Hφ1, Hφ2 – GND
–10 to +15
V
Hφ1, Hφ2 – φSUB
–55 to +10
V
VL – φSUB
–65 to +0.3
V
Vφ1, Vφ3, VDD, VOUT – VL
–0.3 to +27.5
V
RG – GND
–0.3 to +20.5
V
Vφ2, Vφ4, Hφ1, Hφ2, GND – VL
–0.3 to +17.5
V
Storage temperature
–30 to +80
°C
Operating temperature
–10 to +60
°C
Substrate clock φSUB–GND
Supply voltage
Clock input voltage
Vφ1, Vφ2, Vφ3, Vφ4 – φSUB
∗1 +24V (Max.) when clock width < 10µs, clock duty factor < 0.1%.
–2–
Remarks
∗1
ICX069AKB
Bias Conditions
Item
Symbol
Supply voltage
VDD
Protective transistor bias
VL
Substrate clock
φSUB
Min.
Typ.
Max.
Unit
14.55
15.0
∗1
15.45
V
Remarks
∗2
∗1 VL setting is the VVL voltage of the vertical transfer clock waveform, or the same power supply as the VL
power supply for the V driver should be used.
∗2 Do not apply a DC bias to the substrate clock pin, because a DC bias is generated within the CCD.
DC Characteristics
Symbol
Item
Supply current
Min.
IDD
Typ.
Max.
Unit
6
8
mA
Remarks
Clock Voltage Conditions
Item
Readout clock voltage
Vertical transfer clock
voltage
Horizontal transfer
clock voltage
Min.
Typ.
Max.
Unit
Waveform
diagram
VVT
14.55
15.0
15.45
V
1
VVH1, VVH2
–0.05
0
0.05
V
2
VVH3, VVH4
–0.2
0
0.05
V
2
VVL1, VVL2,
VVL3, VVL4
–8.0
–7.5
–7.0
V
2
VVL = (VVL3 + VVL4)/2
VφV
6.8
7.5
8.05
V
2
VφV = VVHn – VVLn (n = 1 to 4)
Symbol
VVH = (VVH1 + VVH2)/2
VVH3 – VVH
–0.25
0.1
V
2
VVH4 – VVH
–0.25
0.1
V
2
VVHH
0.3
V
2
High-level coupling
VVHL
0.3
V
2
High-level coupling
VVLH
0.3
V
2
Low-level coupling
VVLL
0.3
V
2
Low-level coupling
VφH
3.3
5.0
5.25
V
3
VHL
–0.05
0
0.05
V
3
4.5
5.0
5.5
V
4
Input through 0.01µF
capacitance
0.8
V
4
Low-level coupling
VDD + VDD + VDD +
0.3
0.6
0.9
V
4
21.5
V
5
VφRG
Reset gate clock
voltage
Remarks
VRGLH – VRGLL
VRGH
Substrate clock voltage VφSUB
22.5
–3–
23.5
ICX069AKB
Clock Equivalent Circuit Constant
Item
Symbol
Min.
Typ.
Max.
Unit
CφV1, CφV3
680
pF
CφV2, CφV4
470
pF
CφV12, CφV34
220
pF
CφV23, CφV41
220
pF
CφV13
75
pF
CφV24
75
pF
Capacitance between horizontal
transfer clock and GND
CφH1, CφH2
33
pF
Capacitance between horizontal
transfer clocks
CφHH
30
pF
Capacitance between reset gate clock
and GND
CφRG
5
pF
Capacitance between substrate clock
and GND
CφSUB
170
pF
Vertical transfer clock series resistor
R1, R2, R3, R4
82
Ω
Vertical transfer clock ground resistor
RGND
15
Ω
Horizontal transfer clock series resistor
RφH
39
Ω
Reset gate clock series resistor
RφRG
39
Ω
Capacitance between vertical transfer
clock and GND
Capacitance between vertical transfer
clocks
Remarks
Vφ2
Vφ1
CφV12
R1
R2
RφH
RφH
Hφ2
Hφ1
CφV1
CφV23
CφV41
CφV24
R4
CφHH
CφV2
CφH1
CφH2
CφV13
CφV4 RGND CφV3
R3
CφV34
Vφ4
Vφ3
Vertical transfer clock equivalent circuit
Horizontal transfer clock equivalent circuit
RφRG
RGφ
CφRG
Reset gate clock equivalent circuit
–4–
ICX069AKB
Drive Clock Waveform Conditions
(1) Readout clock waveform
100%
90%
II
II
φM
VVT
φM
2
10%
0%
tr
twh
0V
tf
(2) Vertical transfer clock waveform
Vφ1
Vφ3
VVHH
VVH1
VVHH
VVH
VVHL
VVHL
VVH3
VVHL
VVL1
VVH
VVHH
VVHH
VVHL
VVL3
VVLH
VVLH
VVLL
VVLL
VVL
VVL
Vφ2
Vφ4
VVHH
VVHH
VVH
VVH
VVHH
VVHH
VVHL
VVH2 VVHL
VVHL
VVH4
VVL2
VVHL
VVLH
VVLH
VVLL
VVLL
VVL
VVL4
VVH = (VVH1 + VVH2)/2
VVL = (VVL3 + VVL4)/2
VφV = VVHn – VVLn (n = 1 to 4)
–5–
VVL
ICX069AKB
(3) Horizontal transfer clock waveform
tr
twh
tf
90%
VφH
twl
10%
VHL
(4) Reset gate clock waveform
tr
twh
tf
VRGH
twl
Point A
RG waveform
VφRG
VRGL + 0.5V
VRGLH
VRGL
VRGLL
Hφ1 waveform
2.5V
VRGLH is the maximum value and VRGLL is the minimum value of the coupling waveform during the period from
Point A in the above diagram until the rising edge of RG. In addition, VRGL is the average value of VRGLH and
VRGLL.
VRGL = (VRGLH + VRGLL)/2
Assuming VRGH is the minimum value during the interval twh, then:
VφRG = VRGH – VRGL
(5) Substrate clock waveform
100%
90%
φM
VφSUB
10%
0%
VSUB
(A bias generated within the CCD)
tr
twh
–6–
φM
2
tf
ICX069AKB
Clock Switching Characteristics
Item
Symbol
VT
Vertical transfer
clock
Vφ1, Vφ2,
Vφ3, Vφ4
Horizontal
transfer clock
Readout clock
During
imaging
twh
twl
tr
tf
Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Min. Typ. Max.
2.3 2.5
0.5
0.5
µs
Hφ1
19
24
21
26
10
15
10
15
Hφ2
21
26
19
24
10
15
10
15
5.38
Reset gate clock
φRG
11
Substrate clock
φSUB
1.5 1.8
13
During
readout
250 ns ∗1
15
During
Hφ1
parallel-serial
Hφ2
conversion
Unit Remarks
0.01
0.01
5.38
0.01
0.01
51
3
3
0.5
ns ∗2
µs
ns
0.5
µs
During drain
charge
∗1 When vertical transfer clock driver CXD1267 is used.
∗2 tf ≥ tr –2ns, and the cross-point voltage (VCR) for the Hφ1 rising side of the Hφ1 and Hφ2 waveforms must be
at least VφH/2 [V].
Item
Horizontal transfer clock
Symbol
Hφ1, Hφ2
two
Min.
Typ.
16
20
Max.
Unit
Remarks
ns
∗3
∗3 The overlap period for twh and twl of horizontal transfer clocks Hφ1 and Hφ2 is two.
–7–
ICX069AKB
Image Sensor Characteristics
Item
(Ta = 25°C)
Symbol
Min.
Typ.
Sensitivity
S
220
280
Saturation signal
Ysat
540
Smear
Sm
Video signal shading
SHy
Unit
Measurement method
mV
1
mV
2
%
3
20
%
4
Zone 0 and I
25
%
4
Zone 0 to II'
∆Sr
10
%
5
∆Sb
10
%
5
Dark signal
Ydt
2
mV
6
Ta = 60°C
Dark signal shading
∆Ydt
1
mV
7
Ta = 60°C
Flicker Y
Fy
2
%
8
Flicker R-Y
Fcr
5
%
8
Flicker B-Y
Fcb
5
%
8
Line crawl R
Lcr
3
%
9
Line crawl G
Lcg
3
%
9
Line crawl B
Lcb
3
%
9
Line crawl W
Lcw
3
%
9
Lag
Lag
0.5
%
10
Uniformity between video
signal channels
Max.
0.009 0.015
Remarks
Ta = 60°C
Zone Definition of Video Signal Shading
752 (H)
12
12
8
V
10
H
8
H
8
Zone 0, I
Zone II, II'
V
10
582 (V)
6
Ignored region
Effective pixel region
Measurement System
[∗Y]
[∗A]
CCD output signal
Y signal output
LPF1
(3dB down 6.3MHz)
CCD
C.D.S
AMP
S
[∗C]
H
LPF2
S H
Chroma signal output
(3dB down 1MHz)
Note) Adjust the amplifier gain so that the gain between [∗A] and [∗Y] , and between [∗A] and [∗C] equals 1.
–8–
ICX069AKB
Image Sensor Characteristics Measurement Method
Measurement conditions
1) In the following measurements, the device drive conditions are at the typical values of the bias and clock
voltage conditions.
2) In the following measurements, spot blemishes are excluded and, unless otherwise specified, the optical
black level (OB) is used as the reference for the signal output, which is taken as the value of Y signal output
or chroma signal output of the measurement system.
Color coding of this image sensor & Composition of luminance (Y) and chroma (color difference) signals
Cy
Ye
Cy
Ye
A1
G
Mg
G
Mg
Cy
Ye
Cy
Ye
Mg
G
Mg
G
B
A2
As shown in the left figure, fields are read out. The charge is
mixed by pairs such as A1 and A2 in the A field. (pairs such
as B in the B field)
As a result, the sequence of charges output as signals from
the horizontal shift register (Hreg) is, for line A1, (G + Cy),
(Mg + Ye), (G + Cy), and (Mg + Ye).
Hreg
Color Coding Diagram
These signals are processed to form the Y signal and chroma (color difference) signal. The Y signal is formed
by adding adjacent signals, and the chroma signal is formed by subtracting adjacent signals. In other words,
the approximation:
Y = {(G + Cy) + (Mg + Ye)} × 1/2
= 1/2 {2B + 3G + 2R}
is used for the Y signal, and the approximation:
R – Y = {(Mg + Ye) – (G + Cy)}
= {2R – G}
is used for the chroma (color difference) signal. For line A2, the signals output from Hreg in sequence are
(Mg + Cy), (G + Ye), (Mg + Cy), (G + Ye).
The Y signal is formed from these signals as follows:
Y = {(G + Ye) + (Mg + Cy)} × 1/2
= 1/2 {2B + 3G + 2R}
This is balanced since it is formed in the same way as for line A1.
In a like manner, the chroma (color difference) signal is approximated as follows:
– (B – Y) = {(G + Ye) – (Mg + Cy)}
= – {2B – G}
In other words, the chroma signal can be retrieved according to the sequence of lines from R – Y and – (B – Y)
in alternation. This is also true for the B field.
–9–
ICX069AKB
Definition of standard imaging conditions
1) Standard imaging condition I:
Use a pattern box (luminance 706cd/m2, color temperature of 3200K halogen source) as a subject. (Pattern
for evaluation is not applicable.) Use a testing standard lens with CM500S (t = 1.0mm) as an IR cut filter and
image at F5.6. The luminous intensity to the sensor receiving surface at this point is defined as the standard
sensitivity testing luminous intensity.
2) Standard imaging condition II:
Image a light source (color temperature of 3200K) with a uniformity of brightness within 2% at all angles.
Use a testing standard lens with CM500S (t = 1.0mm) as an IR cut filter. The luminous intensity is adjusted
to the value indicated in each testing item by the lens diaphragm.
1. Sensitivity
Set to standard imaging condition I. After selecting the electronic shutter mode with a shutter speed of
1/250s, measure the Y signal (Ys) at the center of the screen and substitute the value into the following
formula.
S = Ys ×
250
[mV]
50
2. Saturation signal
Set to standard imaging condition II. After adjusting the luminous intensity to 10 times the intensity with
average value of the Y signal output, 200mV, measure the minimum value of the Y signal.
3. Smear
Set to standard imaging condition II. With the lens diaphragm at F5.6 to F8, adjust the luminous intensity to
500 times the intensity with average value of the Y signal output, 200mV. When the readout clock is
stopped and the charge drain is executed by the electronic shutter at the respective H blankings, measure
the maximum value YSm [mV] of the Y signal output and substitute the value into the following formula.
Sm =
1
YSm
1
×
×
× 100 [%] (1/10V method conversion value)
10
200
500
4. Video signal shading
Set to standard imaging condition II. With the lens diaphragm at F5.6 to F8, adjust the luminous intensity so
that the average value of the Y signal output is 200mV. Then measure the maximum (Ymax [mV]) and
minimum (Ymin [mV]) values of the Y signal and substitute the values into the following formula.
SHy = (Ymax – Ymin)/200 × 100 [%]
5. Uniformity between video signal channels
Set to standard imaging condition II. Adjust the luminous intensity so that the average value of the Y signal
output is 200mV, and then measure the maximum (Crmax, Cbmax [mV]) and minimum (Crmin, Cbmin
[mV]) values of the R – Y and B – Y channels of the chroma signal and substitute the values into the
following formula.
∆Sr = | (Crmax – Crmin)/200 | × 100 [%]
∆Sb = | (Cbmax – Cbmin)/200 | × 100 [%]
6. Dark signal
Measure the average value of the Y signal output (Ydt [mV]) with the device ambient temperature 60°C and
the device in the light-obstructed state, using the horizontal idle transfer level as a reference.
– 10 –
ICX069AKB
7. Dark signal shading
After measuring 6, measure the maximum (Ydmax [mV]) and minimum (Ydmin [mV]) values of the Y signal
output and substitute the values into the following formula.
∆Ydt = Ydmax – Ydmin [mV]
8. Flicker
1) Fy
Set to standard imaging condition II. Adjust the luminous intensity so that the average value of the Y signal
output is 200mV, and then measure the difference in the signal level between fields (∆Yf [mV]). Then
substitute the value into the following formula.
Fy = (∆Yf/200) × 100 [%]
2) Fcr, Fcb
Set to standard imaging condition II. Adjust the luminous intensity so that the average value of the Y signal
output is 200mV, insert an R or B filter, and then measure both the difference in the signal level between
fields of the chroma signal (∆Cr, ∆Cb) as well as the average value of the chroma signal output (CAr, CAb).
Substitute the values into the following formula.
Fci = (∆Ci/CAi) × 100 [%] (i = r, b)
9. Line crawls
Set to standard imaging condition II. Adjust the luminous intensity so that the average value of the Y signal
output is 200mV, and then insert a white subject and R, G, and B filters and measure the difference
between Y signal lines for the same field (∆Ylw, ∆Ylr, ∆Ylg, ∆Ylb [mV]). Substitute the values into the
following formula.
Lci = (∆Yli/200) × 100 [%] (i = w, r, g, b)
10. Lag
Adjust the Y signal output value generated by strobe light to 200mV. After setting the strobe light so that it
strobes with the following timing, measure the residual signal (Ylag). Substitute the value into the following
formula.
Lag = (Ylag/200) × 100 [%]
FLD
SG1
Light
Strobe light
timing
Y signal output 200mV
Output
– 11 –
Ylag (lag)
RG
Hφ1
Hφ2
XV4
XSG2
XV3
XSG1
XV1
XV2
XSUB
16
5
22/20V
10
11
12
13
8
9
14
7
15
17
CXD1267
18
4
6
19
22/16V
0.01
1/35 V
13 12 11 10
1/20V
100k
7
6
ICX069AKB
(BOTTOM VIEW)
5
4
3
2
1
0.1
Hφ1
3
100k
RG
20
Vφ4
VL
2
GND
1
VOUT
15V
Vφ2
Vφ3
Hφ2
NC
Vφ1
9
φSUB
– 12 –
8
VDD
Drive Circuit
3.3/20V
0.01
2SK523
3.9k
100
2200p
3.3/16V
1M
CCD OUT
–7.5V
ICX069AKB
ICX069AKB
Spectral Sensitivity Characteristics
(excludes both lens characteristics and light source characteristics)
1.0
Ye
0.8
Relative Response
Cy
G
0.6
0.4
Mg
0.2
0.0
400
450
500
550
600
650
700
Wave length [nm]
Sensor Readout Clock Timing Chart
HD
V1
2.6
V2
Odd Field
V3
V4
1.5
41.6
2.6 2.6 2.6
0.2
V1
V2
Even Field
V3
V4
Unit : µs
– 13 –
– 14 –
CLP1
CCD
OUT
V4
V3
V2
V1
SG2
SG1
HD
BLK
VD
FLD
581
582
625
1
2
3
4
5
620
Drive Timing Chart (Vertical Sync)
15
2 4 6
1 3 5
20
2 4 6
1 3 5
315
582
581
1 3 5
2 4 6
335
1 3 5
2 4 6
ICX069AKB
340
330
325
320
310
25
10
– 15 –
SUB
CLP1
V4
V3
V2
V1
SHD
SHP
RG
H2
H1
BLK
HD
10
1
5
750
752
Drive Timing Chart (Horizontal Sync)
ICX069AKB
20
10
5
20
1
1
10
1
5
40
30
20
ICX069AKB
Notes on Handling
1) Static charge prevention
CCD image sensors are easily damaged by static discharge. Before handling be sure to take the following
protective measures.
a) Either handle bare handed or use non-chargeable gloves, clothes or material.
Also use conductive shoes.
b) When handling directly use an earth band.
c) Install a conductive mat on the floor or working table to prevent the generation of static electricity.
d) Ionized air is recommended for discharge when handling CCD image sensor.
e) For the shipment of mounted substrates, use boxes treated for the prevention of static charges.
2) Soldering
a) Make sure the package temperature does not exceed 80°C.
b) Solder dipping in a mounting furnace causes damage to the glass and other defects. Use a ground 30W
soldering iron and solder each pin in less than 2 seconds. For repairs and remount, cool sufficiently.
c) To dismount an image sensor, do not use a solder suction equipment. When using an electric desoldering
tool, use a thermal controller of the zero cross On/Off type and connect it to ground.
3) Dust and dirt protection
Image sensors are packed and delivered by taking care of protecting its glass plates from harmful dust and
dirt. Clean glass plates with the following operation as required, and use them.
a) Operate in clean environments (around class 1000 is appropriate).
b) Do not either touch glass plates by hand or have any object come in contact with glass surfaces. Should
dirt stick to a glass surface, blow it off with an air blower. (For dirt stuck through static electricity ionized air
is recommended.)
c) Clean with a cotton bud and ethyl alcohol if the grease stained. Be careful not to scratch the glass.
d) Keep in a case to protect from dust and dirt. To prevent dew condensation, preheat or precool when
moving to a room with great temperature differences.
e) When a protective tape is applied before shipping, just before use remove the tape applied for
electrostatic protection. Do not reuse the tape.
4) Do not expose to strong light (sun rays) for long periods, color filters will be discolored. When high
luminance objects are imaged with the exposure level control by electronic-iris, the luminance of the imageplane may become excessive and discolor of the color filter will possibly be accelerated. In such a case, it is
advisable that taking-lens with the automatic-iris and closing of the shutter during the power-off mode should
be properly arranged. For continuous using under cruel condition exceeding the normal using condition,
consult our company.
5) Exposure to high temperature or humidity will affect the characteristics. Accordingly avoid storage or usage
in such conditions.
6) CCD image sensors are precise optical equipment that should not be subject to too much mechanical
shocks.
7) Eclipse (to get dark around the four corners of the picture) may occur when some object lenses are in the
open iris state.
Top view
AAAAAA
AAAAAA
AAAAAA
AAAAAA
AAAAAA
AAAAAA
Effective
image
sensor
area
– 16 –
4.14
φ5
.1
2
Sealed resin exuded area
1.4
2.0
H
Ceramic
GOLD PLATING
Fe-Ni-Co Alloy
0.4g
LEAD TREATMENT
LEAD MATERIAL
PACKAGE WEIGHT
+ 0.1
φ0.25 – 0.05
~
1.5
3.80
7.25 ± 0.1
7.60 ± 0.25
V
PACKAGE MATERIAL
PACKAGE STRUCTURE
~
A
0
25
0.
B'
±
6
5
11
4
3
C
1
13
2
12
71
φ5.
φ0.3
M
∗ Center of the package: The center is halfway between two pairs of opposite sides,
as measured from “B”, “B'”.
8. The thickness of the cover glass is 0.75mm, and the refractive index is 1.5.
7. The tilt of the effective image area relative to the bottom “C” is less than 60µm.
6. The height from the bottom “C” to the effective image area is 1.44 ± 0.15mm.
5. The rotation angle of the effective image area relative to H and V is ± 1°.
4. The center of the effective image area relative to the center of the package (∗)
is (H, V) = (0, 0) ± 0.15mm.
3. The bottom “C” of the package is the height reference.
2. The point “B” of the package is the horizontal reference.
The point “B'” of the package is the vertical reference.
1. “A” is the center of the effective image area.
7
9
10
12- .71°
25
8
0
B
φ8
.0
.4
φ4
~
13pin PCA
12
.86
°
Unit: mm
7.60 ± 0.25
7.25 ± 0.1
3.80
3.15
2.50 ± 0.3
– 17 –
1.4
Package Outline
ICX069AKB