2132 2116 d e v MODELS o r p m r i th me i i w t . . . Model 2132 1/32 DIN (48 x 24mm) EUROTHERM ON TROL S Model 2116 1/16 DIN (48 x 48mm) PID Temperature Controllers Ideal for: • Ovens • Chillers • Sterilisers • Trace heating • Heat sealing Available in compact 1/32 and 1/16 DIN panel sizes, the 2132 and 2116 temperature controllers are designed for accurate, trouble free control of ovens, chillers, sterilisers and other simple heating and cooling processes. Two outputs are configurable for heating, cooling and alarms. Eurotherm’s advanced control techniques give stable “straight-line” temperature control. Self tuning is included to optimise the control performance without the need for specialist knowledge or training. Heater failure can be detected when the controller is used with a Eurotherm TE10S Solid State Relay (requires PDSIO mode 1). Three internal alarm setpoints are provided, configurable as latching or non-latching. Alarms can be “blocked” on start-up to prevent unnecessary operator alerts. Calibration accuracy is maintained with a self-correcting input circuit. User calibration allows offsets to be applied to compensate for sensor and other system errors. Improved timer An improved timer can apply heating (and cooling) for a pre-set period, or delay heating to come on after a set time. The latter is useful for over-night batch processing. Features: • Universal input Covers a wide range of temperature and process inputs • Self tuning Easy commissioning • In-built timer Sets heating/cooling times • Setpoint rate limit Provides ramp-dwell heat treatment profile • Tactile buttons Friendly to use • Wide-range 85-264V ac, or 20-29Vac/dc supply Can be installed world-wide • Plug-in from front Rapid replacement - reducing downtime • IP65 and NEMA 4X panel sealing Can be used in wet and dusty atmospheres • Three year warranty Low ownership cost PID Temperature Controllers Dimensions 2132 2116 103 mm (4.01in) 48 mm (1.89in) - 0.0 + 0.3 22.2 2132 24 mm (0.95in) Panel cut-out Panel cut-out 103 mm (4.01in) 48 mm (1.89in) 2116 - 0.0 - 0.0 + 0.6 45 x 45 mm + 0.6 OP1 x 45 mm OP1 OP2 48 mm (1.89in) OP2 - 0.00 + 0.02 1.77 x 1.77in - 0.0 + 0.01 0.88 - 0.0 + 0.02 x 1.77in Electrical connections 2132 Low voltage supply 2116 External Relay Module 24 20-29Vac/dc L Line 85-264Vac Neutral N 1B 1A AA External Relay Module 24 Output 2 (Relay) AB OR 1A Solid State Relay OR 1B V+ + Output 1 1A (Logic) 1B - Solid State Relay T/C Output 1 (Logic) 1B - 1A + V- V+ AA Outpt 2 (Relay) T/C Supply voltage: 85-264Vac, 48-62Hz, or 20-29Vac/dc, 5watts max Operating ambients: 0-55°C, 5-95%RH non-condensing Output ratings: Logic: 9Vdc, 12mA (non-isolated) (Can also be used as alarm acknowledge, keylock and timer start/stop input) Relay: 2A, 264V ac resistive Calibration accuracy: ± 1°C or ± 0.25% of reading whichever is greater Cold junction compensation: >15 to 1 rejection of ambient temperature change Input filtering: Off to 999.9 seconds L N Neutral Line 85-264Vac PT100 20-29Vac/dc 24 24 mA Input 2.49Ω Low voltage supply Sensor inputs Ordering Code Model Number Model Number 2132 48 x 24mm unit 2116 48 x 48mm unit Function CC NF TC TN PID Controller ON/Off Controller PID Controller + Timer ON/Off Contr’ + Timer Supply Voltage VH 85-264Vac VL 20-29V dc or ac Function Supply Voltage Output 1 (Logic) XX No function Logic output LH Heating LC Cooling M1 PDS heater break detect (note 1) FH High alarm 1 FL Low alarm 1 DB Dev. band alarm 1 DL Dev. low larm 1 DH Dev. high alarm 1 NW New alarm Logic input AC Alarm ack/reset KL Keylock TM Timer Off/On Manual Output 2 (Relay) XX RH RC FH FL AL DB DL DH NW No function Heating Cooling High alarm 2 Low alarm 2 High alarm 2 & low alarm 3 Dev. band alarm 2 Dev. low larm 2 Dev. high alarm 2 New alarm Manual XXX ENG FRA GER NED SPA SWE ITA No manual English French German Dutch Spanish Swedish Italian Note 1. PDS heater break detect will transmit the power demand to a TE10S Solid State Relay and read beck a heater break alarm. EUROTHERM CONTROLS LIMITED http://www.eurotherm.co.uk Output 1 (Logic) Output 2 (Relay) Sensor Input Sensor Input Setpoint Min. Setpoint Max. note 2 note 2 Sales and support in over 30 countries worldwide Enquiries/orders to: Eurotherm Controls Limited Export Dept., Faraday Close, Durrington, Worthing. West Sussex BN13 3PL. Telephone (01903) 268500, Fax (01903) 265982 Units Ext. Relay Module Setpoint Min/Max Thermocouples J Type J K Type K T Type T L Type L N Type N R Type R S Type S B Type B P Platinell II Resistance thermometer Z Pt100 Custom downloaded inputs C Type C - W5%Re/W26%Re (default custom sensor) D Type D - W3%Re/W25%Re E E Thermocouple 1 Ni/Ni18%Mo 2 Pt20%Rh/Pt40%Rh 3 W/W26%Re (Englehard) 4 W/W26%Re (Hoskins) 5 W5%Re/W26%Re (Englehard) 6 W5%Re/W26%Re (Bucose) 7 Pt10%Rh/Pt40%Rh 8 Exegen K80 I.R. pyrometer Process inputs (linear) M -9.99 to +80mV Y 0 to 20mA (note 3) A 4 to 20mA (note 3) V 0 to 10Vdc (input adapter required) UK SALES OFFICE Eurotherm Controls Limited. Faraday Close, Durrington, Worthing, West Sussex BN13 3PL Telephone Sales: (01903) 695888; Technical: (01903) 695777; Service: (01903) 695444 Fax (01903) 695666 PT100 Timer range: 0-9999 minutes Setpoint rate limit adjustment: 0-999.9 least significant display unit per minute. Adjustable hysteresis Alarm configuration: High, low, deviation band, deviation high and low EMC standards: Meets generic emissions standard EN50081-2 and immunity standard EN50082-2 for industrial environments Safety standard: Meets EN61010, installation category II. Pollution degree 2 Atmospheres: Not suitable for use above 2000m or in explosive or corrosive atmospheres Specifications AB 2.49Ω Sensor inputs mA Input V- Units Min °C Max -210 to 1200 -200 to 1372 -200 to 400 -200 to 900 -200 to 1300 -50 to 1768 -50 to 1768 0 to 1820 0 to 1369 -200 0 Input Adaptor to C F K X °C °F Kelvin Linear input External Relay Module XX Not fitted R7 Fitted (Operated by the logic output) 850 to 2319 0 -200 0 0 0 0 10 0 200 -45 to to to to to to to to to to 2399 999 1399 1870 2000 2010 2300 2000 1800 650 -1999 -1999 -1999 -1999 to to to to 9999 9999 9999 9999 Input Adaptor XX Not fitted V1 0-10Vdc A1 0-20mA or 4-20mA 0.1% current sense resistor (2.49Ω) Note 2. Setpoint min and max: include the decimal position required in the display value; up to one for temperature input, up to two for process inputs. Note 3. An external 1% current sense resistor is supplied as standard. If greater accuracy is required specify ‘A1’ in the Input Adaptor field. © Copyright Eurotherm Controls Limited 1997 All rights strictly reserved. No part of this document may be stored in a retrieval system, or any form or by any means without prior written permission from Eurotherm Controls Limited. Every effort has been taken to ensure the accuracy of this specification. However in order to maintain our technological lead we are continuously improving our products which could, without notice, result in amendments or omissions to this specification. We cannot accept responsibility for damage, injury, loss or expenses resulting therefrom. Part No. HA026158 Issue 2