MA-COM LTP180S

PolySwitch™ Resettable Device Short Form Catalog
MAY 2005
www.circuitprotection.com
For over 20 years, Raychem Circuit Protection, a unit of Tyco Electronics, has
pioneered the technology behind PolySwitch™ PPTC (Polymeric Positive
Temperature Coefficient) devices. The use of PPTC devices as a variable resistor
in circuit protection applications was first pioneered by Raychem several
decades ago. They were first used to help protect nickel-cadmium battery packs
against excessive discharge and are still being used in that application today.
For the latest product information please
visit us at:
Raychem Circuit Protection PolySwitch devices are commonly called resettable
devices to distinguish them from traditional one-shot fuses that work only once
and then must be replaced—an expensive and inconvenient proposition. While
the generic term for these devices is “resettable fuses”, technically they are not
fuses but actually non-linear thermistors.
Americas:
Europe:
Asia Pacific:
Japan:
Designed for use in a wide range of electronic devices, these thermistor-type
devices limit the flow of dangerously high current during fault conditions. But
unlike traditional fuses that work one time and must be replaced, Raychem
Circuit Protection’s PPTC devices reset after the fault is cleared and power to the
circuit is removed. This reduces service and repair costs, resulting in improved
customer satisfaction and reduced warranty costs.
To date, billions of PolySwitch products are used to help protect a wide range of
electronic products in automotive, battery and portable electronics, computer
and peripherals, consumer, industrial, and telecommunication markets. In
addition, Raychem Circuit Protection continues to expand their circuit protection
offerings with Telecom Fuses, ROV Radial-leaded Metal Oxide Varistors, SiBar™
Thyristor surge protectors, Raychem Gas Discharge Tubes for overvoltage
protection, and most recently, Polymer electrostatic discharge (PESD) protection
devices.
Raychem Circuit Protection is recognized as a leader for operational excellence
and customer service. A dedicated direct engineering sales force, world-wide
manufacturing and design centers, and local engineering support help them to
think, manage and share globally, yet act locally, to meet customer needs. They
are in compliance with globally recognized ISO9000 standards and certified to
QS9000 standards.
The division is headquartered in Menlo Park, CA with manufacturing facilities in
California (USA), China, and Japan, with sales offices worldwide.
www.circuitprotection.com
www.circuitprotection.com.hk (Chinese)
www.raychem.co.jp/polyswitch (Japanese)
(800) 227-7040 or (650) 361-6900
32-16-35 1321
852-2738-3401
81-44-900-5110
PolySwitch Resettable Device
Benefits:
• Reduced warranty and service costs
• Increased reliability
• Superior shock and vibration withstand
• Wide variety of applications
Features:
• Remotely resettable
• Testable
• Solid-state
• Variety of form factors
• Low resistance devices available
PolySwitch devices can be used in a wide variety of applications:
Automotive
• Actuators and medium motors
• Trace protection
• Powered outputs
• Electronic control modules
• Telematics
Battery Protection
• Lithium cells and battery packs
• Rechargeable battery packs
• Chargers
Computers and Peripherals
• DDC.2 computer video ports
• Hard disk drives/storage devices
• IEEE 1394 ports
• Mouse and keyboard ports
• USB (Universal Serial Bus) ports
• PC (PCMCIA) cards and sockets
• SCSI
Industrial
• MOSFET device protection
• Motors, fans, and blowers
• POS equipment
• Process and industrial controls
• Security and fire alarm systems
• Test and measurement equipment
• Transformers
• Power supplies
Consumer
• Loudspeakers
• Satellite video receivers
Telecommunications & Networking
• Central office equipment
• Customer premise equipment
• Primary protection: MDF modules,
Network Interface Devices (NIDs)
• xDSL modems and ISDN equipment
• WAN, LAN, T1/E1 equipment
• Cable power passing taps
• UL 60950, Telcordia GR-1089, GR-974
compliant equipment
• Equipment compliant with ITU-T K.20, K.21,
K.45 resistibility recommendations
• Distributed power supplies
What’s New Inside:
• Radial-leaded Products
- RoHS compliant RHE
• Surface-mount Products
- RoHS compliant nanoSMD
- RoHS compliant microSMD
- RoHS compliant miniSMD
- RoHS compliant decaSMD
- RoHS compliant SMDH
• Automotive Products
- RoHS compliant AHR
• Telecom Products
- RoHS compliant TR600
- RoHS compliant TS600
- RoHS compliant TSM600
D E V I C E S F O R A U T O M O T I V E A P P L I C AT I O N S
The AGRF, AHRF, AHS and ASMD series devices are
qualified to operate in automotive environments per
the AEC-Q200 Stress Test Qualification for Passive
Electronics in automotive applications. This specification requires devices to pass a rigorous test plan
designed for automotive environments. Raychem
Circuit Protection’s document is PS400.
Figure 2
Figure 1
A
B
C
AGRF: Radial-leaded
Part
number
AGRF400
AGRF500
AGRF600
AGRF700
AGRF800
AGRF900
AGRF1000
AGRF1100
AGRF1200
AGRF1400
IH* (A)
R1max.
4.0
5.0
6.0
7.0
8.0
9.0
10.0
11.0
12.0
14.0
Lead size
AGRF400-1100, AHRF450-1000
Ø 0.81 (0.032)
20 AWG
Lead size
AGRF1200-1400, AHRF1300-1500
Ø 1.0 (0.04)
18 AWG
B
C
C
A
Side view
End view
End view
(AHS080 only)
ELV Compliant, RoHS Compliant
IH* (A)
Ramax.
3.0
4.3
5.3
6.5
7.6
8.6
9.6
10.5
11.5
13.0
IT (A)
7.6
9.4
10.7
13.2
15.0
16.5
18.5
20.3
22.1
27.3
V max.
(Vdc)
16
16
16
16
16
16
16
16
16
16
I max.
(A)
100
100
100
100
100
100
100
100
100
100
R min.
(Ω)
0.0186
0.0140
0.0095
0.0066
0.0049
0.0041
0.0034
0.0033
0.0030
0.0022
R1max.
(Ω)
0.0610
0.0340
0.0280
0.0200
0.0175
0.0135
0.0102
0.0089
0.0086
0.0064
Ramax.
(Ω)
0.0850
0.0480
0.0320
0.0220
0.0181
0.0140
0.0106
0.0093
0.0091
0.0067
Dimensions (millimeters/inches)
A
B
C
(max.)
(max.)
(typ.)
8.90 (0.35)
14.1 (0.56)
5.08
10.40 (0.41)
15.6 (0.61)
5.08
10.70 (0.42)
18.4 (0.73)
5.08
11.20 (0.44)
21.0 (0.83)
5.08
12.70 (0.50)
22.2 (0.88)
5.08
14.00 (0.55)
23.0 (0.91)
5.08
16.51 (0.65)
25.7 (1.01)
5.08
17.50 (0.69)
26.5 (1.04)
5.08
17.50 (0.69)
28.8 (1.14)
10.90
23.50 (0.93)
28.7 (1.13)
10.90
(0.20)
(0.20)
(0.20)
(0.20)
(0.20)
(0.20)
(0.20)
(0.20)
(0.43)
(0.43)
Fig.
1
1
1
1
1
1
1
1
1
1
Ramax.
(Ω)
0.054
0.032
0.026
0.022
0.0170
0.015
0.010
0.0092
Dimensions (millimeters/inches)
A
B
C
(max.)
(max.)
(typ.)
10.4 (0.41)
15.6 (0.61)
5.08
11.2 (0.44)
21.0 (0.83)
5.08
12.7 (0.50)
22.2 (0.88)
5.08
14.0 (0.55)
23.5 (0.93)
5.08
16.5 (0.65)
25.7 (1.01)
5.08
17.5 (0.69)
26.5 (1.04)
10.90
23.5 (0.93)
28.7 (1.13)
10.90
23.5 (0.93)
28.7 (1.13)
10.90
(0.20)
(0.20)
(0.20)
(0.20)
(0.20)
(0.43)
(0.43)
(0.43)
Fig.
1
1
1
1
1
1
1
1
* Hold current @ 25°C.
AHRF: High Temp Radial-leaded
New
New
Part
number
AHRF450
AHRF600
AHRF650
AHRF750
AHRF900
AHRF1000
AHRF1300
AHRF1500
IH* (A)
R1max.
4.5
6.0
6.5
7.5
9.0
10.0
13.0
15.0
IH* (A)
Ramax.
4.5
6.0
6.5
7.5
9.0
10.0
13.0
15.0
ELV Compliant, RoHS Compliant
IT (A)
8.7
12.0
13.7
14.8
18.5
20.5
27.0
33.0
V max.
(Vdc)
16
16
16
16
16
16
16
16
I max.
(A)
100
100
100
100
100
100
100
100
R min.
(Ω)
0.0170
0.0100
0.0090
0.0074
0.0061
0.0051
0.0034
0.0027
R1max.
(Ω)
0.054
0.032
0.026
0.022
0.012
0.015
0.010
0.0063
* Hold current @ 25°C.
AHS: High Temp Surface-mount
Part
IH (A)
number
R1max.
AHS080-2018 0.80
AHS160
1.60
IH (A)
Ramax.
0.80
1.60
ELV Compliant, RoHS Compliant
IT (A)
2.00
3.20
ASMD: Surface-mount
Part
number
ASMD030
ASMD050
ASMD075
ASMD100
ASMD125
ASMD150
ASMD200
ASMD250
IH (A)
R1max.
0.23
0.39
0.60
0.900
1.040
1.270
1.730
1.970
V max.
(Vdc)
16
16
I max.
(A)
70
70
R min.
(Ω)
0.130
0.050
R1max.
(Ω)
0.550
0.150
Ramax.
(Ω)
0.550
0.150
Dimensions (millimeters/inches)
A
B
C
(max.)
(max.)
(typ.)
5.44 (0.214)
1.52 (0.060) 4.93 (0.194)
9.40 (0.370)
3.00 (0.118) 6.71 (0.264)
Fig.
2
2
R min.
(Ω)
0.980
0.290
0.290
0.098
0.057
0.049
0.050
0.035
R1max.
(Ω)
4.800
1.400
1.000
0.480
0.250
0.250
0.120
0.085
Ramax.
(Ω)
4.800
1.400
1.000
0.480
0.250
0.250
0.120
0.085
Dimensions (millimeters/inches)
A
B
C
(max.)
(max.)
(max.)
7.98 (0.314)
3.18 (0.125) 5.44 (0.214)
7.98 (0.314)
3.18 (0.125) 5.44 (0.214)
7.98 (0.314)
3.18 (0.125) 5.44 (0.214)
7.98 (0.314)
3.00 (0.118) 5.44 (0.214)
7.98 (0.314)
3.00 (0.118) 5.44 (0.214)
9.40 (0.370)
3.00 (0.118) 6.71 (0.264)
9.40 (0.370)
3.00 (0.118) 6.71 (0.264)
9.40 (0.370)
3.00 (0.118) 6.71 (0.264)
Fig.
2
2
2
2
2
2
2
2
ELV Compliant
IH (A)
Ramax.
0.23
0.39
0.60
0.90
1.04
1.27
1.73
1.97
IT (A)
0.59
0.98
1.48
2.16
2.46
2.95
3.93
5.00
V max.
(Vdc)
60
60
30
30
15
15
15
15
I max.
(A)
10
10
40
40
40
40
40
40
1
R A D I A L - L E A D E D D E V I C E S F O R E L E C T R O N I C S A P P L I C AT I O N S
240V
ELV Compliant, RoHS Compliant
Figure 1
The LVR series is the first PolySwitch device family
designed for use at line voltages of 120VAC to
240VAC. They may be used to help provide primary
side protection of chargers, power supplies, and control transformers in many industrial, commercial and
consumer applications. They are also appropriate to
help protect many 120VAC or 240VAC motors. In
addition, the LVR series is RoHS compliant.
Figure 3
Figure 2
A
A
CALIPER
CALIPER
B
B
CALIPER
CALIPER
Lead size
LVR025–040
Ø 0.64 (0.025)
22 AWG
B
CALIPER
LVR055
Ø 0.81 (0.032)
20 AWG
C
C
center-to-center
center-to-center
center-to-center
A
CALIPER
B
C
C
Figure 4
A
Lead size
LVR005-016
Ø 0.51 (0.020)
24 AWG
center-to-center
Dimensions (millimeters/inches)
Part
number
LVR005K
LVR005S
LVR008K
LVR008S
LVR012K
LVR012S
LVR016K
LVR016S
LVR025K
LVR025S
LVR033K
LVR033S
LVR040K
LVR040S
LVR055K
LVR055S
60V – 72V
IH
(A)
0.05
0.05
0.08
0.08
0.12
0.12
0.16
0.16
0.25
0.25
0.33
0.33
0.40
0.40
0.55
0.55
IT
(A)
0.12
0.12
0.19
0.19
0.30
0.30
0.37
0.37
0.56
0.56
0.74
0.74
0.90
0.90
1.25
1.25
I max.
V max. 135Vac/240Vac
(Vac)
(A)
240
20/1.0
240
20/1.0
240
20/1.2
240
20/1.2
240
20/1.2
240
20/1.2
240
20/2.0
240
20/2.0
240
20/3.5
240
20/3.5
240
20/4.5
240
20/4.5
240
20/5.5
240
20/5.5
240
20/5.5
240
20/5.5
ELV Compliant, RoHS Compliant
IH
(A)
0.05
0.10
0.17
0.20
0.25
0.30
0.40
0.50
0.65
0.75
0.90
1.10
1.35
1.60
1.85
2.50
3.00
3.75
IT
(A)
0.10
0.20
0.34
0.40
0.50
0.60
0.80
1.00
1.30
1.50
1.80
2.20
2.70
3.20
3.70
5.00
6.00
7.50
V max.
(V)
60
60
60
72
72
72
72
72
72
72
72
72
72
72
72
72
72
72
Agency
recognition
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
Figure 5
B
Lead size
RXEF005
Ø 0.40 (0.016)
26 AWG
C
I max.**
(A)
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
A
(max.)
8.3 (0.33)
8.3 (0.33)
8.3 (0.33)
8.3 (0.33)
8.3 (0.33)
8.3 (0.33)
9.9 (0.39)
9.9 (0.39)
9.6 (0.38)
9.6 (0.38)
11.4 (0.45)
11.4 (0.45)
11.5 (0.46)
11.5 (0.46)
14.0 (0.55)
14.0 (0.55)
B
(max.)
12.9 (0.51)
10.7 (0.43)
12.9 (0.51)
10.7 (0.43)
12.9 (0.51)
10.7 (0.43)
13.8 (0.54)
12.5 (0.50)
18.8 (0.74)
17.4 (0.69)
19.0 (0.75)
16.5 (0.65)
20.9 (0.82)
19.5 (0.77)
21.7 (0.85)
21.7 (0.85)
Figure 6
A
The RXEF series devices offer hold currents ranging
from 50mA to 3.75A while offering voltage ratings of
60V to 72V. The RXEF products are used in a wide
range of applications such as power input, and I/O
port protection. They are also used in many markets
including computer/multimedia, industrial equipment
and controls, consumer, general electronics and communications and networking.
Part
number
RXEF005
RXEF010
RXEF017
RXEF020
RXEF025
RXEF030
RXEF040
RXEF050
RXEF065
RXEF075
RXEF090
RXEF110
RXEF135
RXEF160
RXEF185
RXEF250
RXEF300
RXEF375
R1max.
(Ω)
65.0
65.0
26.0
26.0
12.0
12.0
7.8
7.8
3.8
3.8
1.24
1.24
1.9
1.9
1.45
1.45
Agency
recognition
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
B
Lead size
RXEF010–090
Ø 0.51 (0.020)
24 AWG
A
B
Lead size
RXEF110-375
Ø 0.81 (0.032)
20 AWG
C
Dimensions (millimeters/inches)
A
B
C
(max.)
(max.)
(nom.)
8.0 (0.32)
8.3 (0.33)
5.08 (0.20)
7.4 (0.29)
11.6 (0.46)
5.08 (0.20)
7.4 (0.29)
12.7 (0.50)
5.08 (0.20)
7.4 (0.29)
11.7 (0.46)
5.08 (0.20)
7.4 (0.29)
12.7 (0.50)
5.08 (0.20)
7.4 (0.29)
12.7 (0.50)
5.08 (0.20)
7.6 (0.30)
13.5 (0.53)
5.08 (0.20)
7.9 (0.31)
13.7 (0.54)
5.08 (0.20)
9.4 (0.37)
14.5 (0.57)
5.08 (0.20)
10.2 (0.40)
15.2 (0.60)
5.08 (0.20)
11.2 (0.44)
15.8 (0.62)
5.08 (0.20)
12.8 (0.50)
17.5 (0.69)
5.08 (0.20)
14.5 (0.57)
19.1 (0.75)
5.08 (0.20)
16.3 (0.64)
20.8 (0.82)
5.08 (0.20)
17.5 (0.69)
22.4 (0.88)
5.08 (0.20)
20.8 (0.82)
25.4 (1.00)
10.90 (0.43)
23.9 (0.94)
28.6 (1.13)
10.90 (0.43)
27.2 (1.07)
31.8 (1.25)
10.90 (0.43)
** Device may withstand higher interrupt current at lower voltages. Each application will need to be individually evaluated.
2
Fig.
1
2
1
2
1
2
1
1
3
4
3
4
3
4
3
4
Figure 7
A
C
R1max.
(Ω)
20.00
7.50
8.00
4.40
3.00
2.10
1.29
1.17
0.72
0.60
0.47
0.38
0.30
0.22
0.19
0.13
0.10
0.08
C
(nom.)
5.08 (0.20)
5.08 (0.20)
5.08 (0.20)
5.08 (0.20)
5.08 (0.20)
5.08 (0.20)
5.08 (0.20)
5.08 (0.20)
5.08 (0.20)
5.08 (0.20)
5.08 (0.20)
5.08 (0.20)
5.08 (0.20)
5.08 (0.20)
5.08 (0.20)
5.08 (0.20)
Fig.
5
6
6
6
6
6
6
6
6
6
6
7
7
7
7
7
7
7
R A D I A L - L E A D E D D E V I C E S F O R E L E C T R O N I C S A P P L I C AT I O N S
33V
ELV Compliant, RoHS Compliant
Figure 8
A
The RTEF series devices offer a 33V rating and
tighter trip-to-hold ratios than other radial-leaded
devices to help comply with the IEEE 1394 specification. These devices can also be used in other
applications where the benefit of a tighter trip-tohold ratio is desired.
Part
number
RTEF120
RTEF135
RTEF190
IH
(A)
1.20
1.35
1.90
IT
(A)
2.3
2.5
3.0
V max.
(V)
33
33
33
Lead size
RTEF120–190
Ø 0.51 (0.020)
24 AWG
B
C
I max.**
(A)
40
40
40
R1max.
(Ω)
0.180
0.143
0.092
Agency
recognition
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
Dimensions (millimeters/inches)
A
B
C
(max.)
(max.)
(nom.)
7.4 (0.29)
12.2 (0.48)
5.08 (0.20)
7.4 (0.29)
14.2 (0.56)
5.08 (0.20)
8.9 (0.35)
13.5 (0.53)
5.08 (0.20)
Fig.
8
8
8
** Device may withstand higher interrupt current at lower voltages. Each application will need to be individually evaluated.
30V
ELV Compliant, RoHS Compliant
Figure 9
Figure 10
A
The RUEF series devices offer hold currents from
900mA to 9.0A. They are used in many markets
including computer/multimedia, industrial equipment
and controls, as well as consumer and general
electronics.
B
Lead size
RUEF090–250
Ø 0.51 (0.020)
24 AWG
C
Part
number
RUEF090
RUEF110
RUEF135
RUEF160
RUEF185
RUEF250
RUEF300
RUEF400
RUEF500
RUEF600
RUEF700
RUEF800
RUEF900
IH
(A)
0.90
1.10
1.35
1.60
1.85
2.50
3.00
4.00
5.00
6.00
7.00
8.00
9.00
IT
(A)
1.8
2.2
2.7
3.2
3.7
5.0
6.0
8.0
10.0
12.0
14.0
16.0
18.0
V max.
(V)
30
30
30
30
30
30
30
30
30
30
30
30
30
I max.**
(A)
40
40
40
40
40
40
40
40
40
40
40
40
40
A
B
Lead size
RUEF300–900
Ø 0.81 (0.032)
20 AWG
C
R1max.
(Ω)
0.22
0.17
0.13
0.11
0.09
0.07
0.08
0.05
0.05
0.04
0.03
0.02
0.02
Agency
recognition
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
Dimensions (millimeters/inches)
A
B
C
(max.)
(max.)
(nom.)
7.4 (0.29)
12.2 (0.48)
5.08 (0.20)
7.4 (0.29)
14.2 (0.56)
5.08 (0.20)
8.9 (0.35)
13.5 (0.53)
5.08 (0.20)
8.9 (0.35)
15.2 (0.60)
5.08 (0.20)
10.2 (0.40)
15.7 (0.62)
5.08 (0.20)
11.4 (0.45)
18.3 (0.72)
5.08 (0.20)
11.4 (0.45)
17.3 (0.68)
5.08 (0.20)
14.0 (0.55)
20.1 (0.79)
5.08 (0.20)
14.0 (0.55)
24.9 (0.98)
10.90 (0.43)
16.5 (0.65)
24.9 (0.98)
10.90 (0.43)
19.1 (0.75)
26.7 (1.05)
10.90 (0.43)
21.6 (0.85)
29.2 (1.15)
10.90 (0.43)
24.1 (0.95)
29.7 (1.17)
10.90 (0.43)
** Device may withstand higher interrupt current at lower voltages. Each application will need to be individually evaluated.
3
Fig.
9
9
9
9
9
9
10
10
10
10
10
10
10
R A D I A L - L E A D E D D E V I C E S F O R E L E C T R O N I C S A P P L I C AT I O N S
16V High Temperature
ELV Compliant, RoHS Compliant
The RHEF series devices offer a high operating temperature (up to 125C) and the broadest range of hold
currents available in the radial-leaded form factor
(70mA to 15A). The RHEF series devices can also be
advantageous for use in standard operating temperatures of up to 85C because they have a flatter thermal
derating curve than other radial-leaded devices. Over
the same temperature range, the trip-to-hold ratio is
lower for an RHEF device compared with other PPTC
devices.
New
New
New
New
Part
number
RHEF 30V
RHEF050
RHEF070
RHEF100
RHEF 16V
RHEF200
RHEF400
RHEF450
RHEF600
RHEF650
RHEF750
RHEF900
RHEF1000
RHEF1300
RHEF1500
A
V max.
(Vdc)
I max.**
(A)
0.5
0.7
1.0
0.92
1.4
1.8
30
30
30
40
40
40
16
16
16
16
16
16
16
16
16
16
100
100
100
100
100
100
100
100
100
100
Figure 13
A
A
B
Lead size
RHEF070
Ø 0.51 (0.020)
24 AWG
B
C
C
C
IT
(A)
3.8
7.0
7.8
10.8
12.0
13.1
16.5
18.5
24.0
28.0
Lead size
RHEF050, 100, 200
Ø 0.51 (0.020)
24 AWG
B
IH*
(A)
2.0
4.0
4.5
6.0
6.5
7.5
9.0
10.0
13.0
15.0
Figure 12
Figure 11
Lead size
RHEF400-1000
Ø 0.81 (0.032)
20 AWG
RHEF1300,
RHEF1500
Ø 1.0 (0.04)
18 AWG
Agency
recognition
Dimensions (millimeters/inches)
A
B
C
(max.)
(max.)
(nom.)
Fig.
1.1
0.8
0.43
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
7.4 (0.29)
6.9 (0.27)
9.7 (0.38)
5.08 (0.20)
5.08 (0.20)
5.08 (0.20)
11
12
11
0.110
0.044
0.054
0.032
0.026
0.022
0.017
0.015
0.010
0.0092
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
(0.20)
(0.20)
(0.20)
(0.20)
(0.20)
(0.20)
(0.20)
(0.43)
(0.43)
(0.43)
11
13
13
13
13
13
13
13
13
13
R1max.
(Ω)
9.40
11.40
10.40
11.20
12.70
14.00
16.50
17.50
23.50
23.50
(0.37)
(0.45)
(0.41)
(0.44)
(0.50)
(0.55)
(0.65)
(0.69)
(0.925)
(0.925)
12.7 (0.50)
10.8 (0.43)
13.6 (0.54)
14.4
18.0
15.6
21.0
22.2
23.5
25.7
26.5
28.7
28.7
(0.57)
(0.71)
(0.61)
(0.83)
(0.88)
(0.93)
(1.01)
(1.04)
(1.13)
(1.13)
5.08
5.08
5.08
5.08
5.08
5.08
5.08
10.90
10.90
10.90
* Hold current @ 25°C.
** Device may withstand higher interrupt current at lower voltages. Each application will need to be individually evaluated.
16V High Temperature
ELV Compliant, RoHS Compliant
The RGEF series devices are rated for 16V and have
hold current ranges of 2.5A to 14A. These parts are
smaller and trip faster than the RUEF devices with the
same hold currents. In addition, they have tight trip-tohold ratios. If the application requires 16V rather than
30V and there are limitations on space, the RGEF
devices can be the preferred choice. Like the RXEF
and RUEF series devices, the RGEF devices are
used in many markets including computer/multimedia,
industrial equipment and controls, consumer and
general electronics, as well as motor protection.
Part
number
RGEF250
RGEF300
RGEF400
RGEF500
RGEF600
RGEF700
RGEF800
RGEF900
RGEF1000
RGEF1100
RGEF1200
RGEF1400
IH*
(A)
2.5
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
11.0
12.0
14.0
IT
(A)
4.7
5.1
6.8
8.5
10.2
11.9
13.6
15.3
17.0
18.7
20.4
23.8
V max.
(Vdc)
16
16
16
16
16
16
16
16
16
16
16
16
Figure 14
Figure 15
A
B
Lead size
RGEF250
Ø 0.51 (0.020)
24 AWG
C
I max.**
(A)
100
100
100
100
100
100
100
100
100
100
100
100
A
B
C
R1max.
(Ω)
0.0530
0.0980
0.0600
0.0340
0.0280
0.0220
0.0175
0.0135
0.0102
0.0089
0.0086
0.0064
Agency
recognition
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
Lead size
RGEF300-RGE1100
Ø 0.81 (0.032)
20 AWG
RGEF1200-RGE1400
Ø 1.0 (0.04)
18 AWG
Dimensions (millimeters/inches)
A
B
C
(max.)
(max.)
(nom.)
8.9 (0.35)
12.8 (0.50)
5.08 (0.20)
7.1 (0.28)
11.0 (0.43)
5.08 (0.20)
8.9 (0.35)
12.8 (0.50)
5.08 (0.20)
10.4 (0.41)
14.3 (0.56)
5.08 (0.20)
10.7 (0.42)
17.1 (0.67)
5.08 (0.20)
11.2 (0.44)
19.7 (0.78)
5.08 (0.20)
12.7 (0.50)
20.9 (0.82)
5.08 (0.20)
14.0 (0.55)
21.7 (0.85)
5.08 (0.20)
16.5 (0.65)
25.2 (0.99)
5.08 (0.20)
17.5 (0.69)
26.0 (1.02)
5.08 (0.20)
17.5 (0.69)
28.0 (1.10)
10.90 (0.43)
23.5 (0.92)
27.9 (1.10)
10.90 (0.43)
* Hold current @ 25°C.
** Device may withstand higher interrupt current at lower voltages. Each application will need to be individually evaluated.
4
Fig.
14
15
15
15
15
15
15
15
15
15
15
15
R A D I A L - L E A D E D D E V I C E S F O R E L E C T R O N I C S A P P L I C AT I O N S
16V High Temperature
ELV Compliant, RoHS Compliant
Figure 16
The RUSBF series devices were developed for the
USB serial bus specification in computer and multimedia applications.
A
Lead size
Ø 0.51 (0.020)
24 AWG
B
C
Part
number
RUSBF090
RUSBF110
RUSBF135
RUSBF160
RUSBF185
RUSBF250
IH
(A)
0.90
1.10
1.35
1.60
1.85
2.50
IT
(A)
1.8
2.2
2.7
3.2
3.7
5.0
V max.
(V)
16
16
16
16
16
16
I max.**
(A)
40
40
40
40
40
40
R1max.
(Ω)
0.18
0.14
0.12
0.11
0.09
0.06
Agency
recognition
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
Dimensions (millimeters/inches)
A
B
C
(max.)
(max.)
(nom.)
7.4 (0.29)
12.2 (0.48)
5.08 (0.20)
7.4 (0.29)
14.2 (0.56)
5.08 (0.20)
8.9 (0.35)
13.5 (0.53)
5.08 (0.20)
8.9 (0.35)
15.2 (0.60)
5.08 (0.20)
10.2 (0.40)
15.7 (0.62)
5.08 (0.20)
11.4 (0.45)
18.3 (0.72)
5.08 (0.20)
Fig.
16
16
16
16
16
16
** Device may withstand higher interrupt current at lower voltages. Each application will need to be individually evaluated.
6V
ELV Compliant, RoHS Compliant
Figure 17
The RUSBF series devices were developed for the
USB serial bus specification in computer and multimedia applications. These 6V products are particularly well suited for USB computer monitor protection
applications where through-hole devices are still the
preferred solution.
A
B
Lead size
Ø 0.51 (0.020)
24 AWG
C
Part
number
RUSBF075
RUSBF120
RUSBF155
IH
(A)
0.75
1.20
1.55
IT
(A)
1.30
2.00
2.65
V max.
(V)
6
6
6
I max.**
(A)
40
40
40
R1max.
(Ω)
0.23
0.14
0.10
Agency
recognition
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
Dimensions (millimeters/inches)
A
B
C
(max.)
(max.)
(nom.)
6.9 (0.27)
11.4 (0.45)
5.08 (0.20)
6.9 (0.27)
11.7 (0.46)
5.08 (0.20)
6.9 (0.27)
11.7 (0.46)
5.08 (0.20)
** Device may withstand higher interrupt current at lower voltages. Each application will need to be individually evaluated.
5
Fig.
17
17
17
TELECOM AND BROADBAND PRODUCTS
These product lines consist of radial-leaded and
surface-mount devices that help protect against short
duration high voltage faults (250-600Vrms). TR and
TS products are designed to help meet the protection
needs of telecommunications applications. BBR
devices help provide overcurrent protection of the
power tap in hybrid-coaxial applications.
Figure 2
Figure 1
A
C
A
B
B
φ 0.65mm
φ 0.65mm
D
E
E
TR250
Part
number
TR250-080T
TR250-080U
TR250-110U
TR250-120
TR250-120T
TR250-120T-RA
TR250-120T-RC
TR250-120T-RF
TR250-120T-R1
TR250-120T-R2
TR250-120U
TR250-120UT
TR250-145
TR250-145-RA
TR250-145-RB
TR250-145T
TR250-145U
TRF250-180†
IH
(A)
0.080
0.080
0.110
0.120
0.120
0.120
0.130
0.120
0.120
0.120
0.120
0.120
0.145
0.145
0.145
0.145
0.145
0.180
IT
(A)
0.160
0.160
0.220
0.240
0.240
0.240
0.240
0.240
0.240
0.240
0.240
0.240
0.290
0.290
0.290
0.290
0.290
0.650
V max. Operating
(Vdc)
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
100
V max. Interrupt
(Vrms)
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
I max.
(A)
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
10.0
R min.
(Ω)
15.0
14.0
5.0
4.0
7.0
7.0
5.4
6.0
6.0
8.0
6.0
7.0
3.0
3.0
4.5
5.4
3.5
0.8
R max.
(Ω)
22.0
20.0
9.0
8.0
12.0
9.0
7.5
10.5
9.0
10.5
10.0
12.0
6.0
5.5
6.0
7.5
6.5
2.2
R1 max.
(Ω)
33.0
33.0
16.0
16.0
16.0
16.0
14.0
16.0
16.0
16.0
16.0
16.0
14.0
12.0
14.0
14.0
12.0
4.0
Agency
recognition
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
These products are intended for telecom applications. For continuous line voltage applications, see LVR product line. Please see the Raychem Circuit Protection Databook for
application details. Most products are available in binned versions for resistance-matched applications. Please see Raychem Circuit Protection Databook for performance details.
† F is for RoHS compliant devices.
Part
number
TR250-080T
TR250-080U
TR250-110U
TR250-120
TR250-120U
TR250-145
TR250-145U
TRF250-180
Dimensions (millimeters/inches)
A
B
(max.)
(max.)
5.8 (0.228)
9.9 (0.390)
4.8 (0.189)
9.3 (0.366)
5.3 (0.210)
9.4 (0.370)
6.5 (0.256)
11.0 (0.433)
6.0 (0.236)
10.0 (0.394)
6.5 (0.256)
11.0 (0.433)
6.0 (0.236)
10.0 (0.394)
9.0 (0.354)
12.0 (0.472)
C
(max.)
4.6 (0.181)
3.8 (0.150)
3.8 (0.150)
4.6 (0.180)
3.8 (0.150)
4.6 (0.180)
3.8 (0.150)
3.8 (0.150)
D
(min.)
4.7 (0.185)
4.7 (0.185)
4.7 (0.185)
4.7 (0.185)
4.7 (0.185)
4.7 (0.185)
4.7 (0.185)
4.7 (0.185)
6
E
(typ.)
5.0 (0.197)
5.0 (0.197)
5.0 (0.197)
5.0 (0.197)
5.0 (0.197)
5.0 (0.197)
5.0 (0.197)
5.0 (0.197)
Fig.
1
1
1
2
2
2
2
1
Fig.
1
1
1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
1
TELECOM AND BROADBAND PRODUCTS
TS250
Figure 3
Figure 4
Figure 5
C
A
C
B
C
B
D
A
E
side view
top view
D
B
D
A
E
Coming Soon
Coming Soon
Coming Soon
Coming Soon
Coming Soon
Coming Soon
Part
number
TS250-130
TS250-130-RA
TS250-130-RB
TS250-130-RC
TS250-130F
TS250-130F-RA
TS250-130F-RB
TS250-130F-RC
TSL250-080
TSL250-080F
TSV250-130
TSV250-130F
IH
(A)
0.130
0.130
0.130
0.130
0.130
0.130
0.130
0.130
0.080
0.080
0.130
0.130
IT
(A)
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.160
0.160
0.260
0.260
V max. Operating
(Vdc)
60
60
60
60
60
60
60
60
80
80
60
60
V max. Interrupt
(Vrms)
250 (650)
250 (650)
250 (650)
250 (650)
250 (650)
250 (650)
250 (650)
250 (650)
250
250
250
250
I max.
(A)
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
R min.
(Ω)
6.5
6.5
9.0
7.0
6.5
6.5
9.0
7.0
5.0
5.0
4.0
4.0
R max.
(Ω)
12.0
9.0
12.0
10.0
12.0
9.0
12.0
10.0
11.0
11.0
7.0
7.0
R1 max.
(Ω)
20.0
15.0
20.0
17.0
20.0
15.0
20.0
17.0
20.0
20.0
12.0
12.0
Agency
recognition
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
Fig.
3
3
3
3
3
3
3
3
4
4
5
5
These products are intended for telecom applications. For continuous line voltage applications, see LVR product line. Please see the Raychem Circuit Protection Databook for
application details. Most products are available in binned versions for resistance-matched applications. Please see Raychem Circuit Protection Databook for performance details.
Coming Soon
Coming Soon
Coming Soon
Coming Soon
Part
number
TS250-130
TS250-130-RA
TS250-130-RB
TS250-130-RC
TS250-130F
TS250-130F-RA
TS250-130F-RB
TS250-130F-RC
Part
number
TSL250-080
Coming Soon TSL250-080F
TSV250-130
Coming Soon TSV250-130F
Dimensions (millimeters/inches)
A
B
(max.)
(max.)
9.4 (0.370)
3.4 (0.135)
9.4 (0.370)
3.4 (0.135)
9.4 (0.370)
3.4 (0.135)
9.4 (0.370)
3.4 (0.135)
9.4 (0.370)
3.4 (0.135)
9.4 (0.370)
3.4 (0.135)
9.4 (0.370)
3.4 (0.135)
9.4 (0.370)
3.4 (0.135)
C
(max.)
7.4 (0.290)
7.4 (0.290)
7.4 (0.290)
7.4 (0.290)
7.4 (0.290)
7.4 (0.290)
7.4 (0.290)
7.4 (0.290)
D
(typ.)
0.3 (0.011)
0.3 (0.011)
0.3 (0.011)
0.3 (0.011)
0.3 (0.011)
0.3 (0.011)
0.3 (0.011)
0.3 (0.011)
Fig.
3
3
3
3
3
3
3
3
Dimensions (millimeters/inches)
A
B
(max.)
(max.)
7.9 (0.310)
3.7 (0.145)
7.9 (0.310)
3.7 (0.145)
6.1 (0.240)
6.9 (0.270)
6.1 (0.240)
6.9 (0.270)
C
(max.)
5.3 (0.210)
5.3 (0.210)
3.0 (0.126)
3.0 (0.126)
D
(max.)
0.4 (0.015)
0.4 (0.015)
1.9 (0.075)
1.9 (0.075)
E
(max.)
3.1 (0.120)
3.1 (0.120)
2.3 (0.091)
2.3 (0.091)
TR600
Figure 6
A
Fig.
4
4
5
5
C
B
φ 0.65mm
D
E
New
Part
number
TRF600-150*
TRF600-150-RB*
TR600-160
TR600-160-RA
TR600-160-R1
IH
(A)
0.150
0.130
0.160
0.160
0.160
IT
(A)
0.300
0.260
0.320
0.320
0.320
V max. Operating
(Vdc)
250
250
250
250
250
V max. Interrupt
(Vrms)
600
600
600
600
600
I max.
(A)
3.0
3.0
3.0
3.0
3.0
R min.
(Ω)
6.0
9.0
4.0
4.0
4.0
R max.
(Ω)
10.0
12.0
10.0
7.0
8.0
R1 max.
(Ω)
17.0
20.0
18.0
16.0
17.0
Agency
recognition
Pending
UL, CSA
UL, CSA
UL, CSA
UL, CSA
Fig.
6
6
6
6
6
These products are intended for telecom applications. For continuous line voltage applications, see LVR product line. Please see the Raychem Circuit Protection Databook for
application details. Most products are available in binned versions for resistance-matched applications. Please see Raychem Circuit Protection Databook for performance details.
* These parts are RoHS compliant. TRF600-150 replaces TR600-150 and TR600-150-RA devices in new designs. TRF600-150-RB replaces TR600-150-RB devices in new designs.
Part
number
TRF600-150*
TR600-160
Dimensions (millimeters/inches)
A
B
(max.)
(max.)
9.0 (0.354)
12.5 (0.492)
16.0 (0.630)
12.6 (0.496)
C
(max.)
4.6 (0.180)
6.0 (0.236)
D
(min.)
4.7 (0.185)
4.7 (0.185)
* This part is RoHS compliant and replaces TR600-150 and TR600-150-RA devices in new designs.
7
E
(max.)
5.0 (0.197)
5.0 (0.197)
Fig.
6
6
TELECOM AND BROADBAND PRODUCTS
TS600
Figure 7
Figure 8
C
B
F
E
D
D
A
New
New
New
New
Part
number
TS600-170
TS600-200-RA-B-0.5
TS600-170F*
TS600-200F-RA-B-0.5*
TSM600-250
TSM600-250-RA
TSM600-250F*
TSM600-250F-RA*
IH
(A)
0.170
0.200
0.170
0.200
0.250
0.250
0.250
0.250
IT
(A)
0.400
0.400
0.400
0.400
0.860
0.860
0.860
0.860
V max. Operating
(Vdc)
60
60
60
60
250
250
250
250
V max. Interrupt
(Vrms)
600
600
600
600
600
600
600
600
I max.
(A)
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
E
G
R min.
(Ω)
4.0
4.0
4.0
4.0
1.0
1.0
1.0
1.0
R max.
R1 max.
(Ω)
(Ω)
9.0
18.0
7.5
13.5
9.0
18.0
7.5
13.5
3.5 (typ.)
7.0
3.0 (typ.)
5.0
3.5 (typ.)
7.0
3.0 (typ.)
5.0
Agency
recognition
UL, CSA
UL, CSA
UL, CSA
UL, CSA
UL, CSA
UL, CSA
UL, CSA
UL, CSA
Fig.
7
7
7
7
8
8
8
8
These products are intended for telecom applications. For continuous line voltage applications, see LVR product line. Please see the Raychem Circuit Protection Databook for
application details.
* These parts are the RoHS compliant versions; they should be used for new designs.
New
New
Part
number
TS600-170
TS600-200-RA-B-0.5
TS600-170F*
TS600-200F-RA-B-0.5*
Dimensions (millimeters/inches)
A
B
(max.)
(max.)
19.4 (0.765)
12.3 (0.485)
19.4 (0.765)
12.3 (0.485)
19.4 (0.765)
12.3 (0.485)
19.4 (0.765)
12.3 (0.485)
C
(max.)
8.3 (0.325)
8.3 (0.325)
8.3 (0.325)
8.3 (0.325)
Fig.
7
7
7
7
* These parts are the RoHS compliant versions; they should be used for new designs.
New
New
Part
number
TSM600-250
TSM600-250-RA
TSM600-250F*
TSM600-250F-RA*
Dimensions (millimeters/inches)
A
B
(max.)
(max.)
17.6 (0.691)
11.7 (0.460)
17.6 (0.691)
11.7 (0.460)
17.6 (0.691)
11.7 (0.460)
17.6 (0.691)
11.7 (0.460)
BBR
C
(max.)
11.2 (0.440)
11.2 (0.440)
11.2 (0.440)
11.2 (0.440)
D
(max.)
5.2 (0.230)
5.2 (0.230)
5.2 (0.230)
5.2 (0.230)
E
(max.)
2.8 (0.111)
2.8 (0.111)
2.8 (0.111)
2.8 (0.111)
F
(max.)
1.0 (0.038)
1.0 (0.038)
1.0 (0.038)
1.0 (0.038)
G
(min.)
2.0 (0.080)
2.0 (0.080)
2.0 (0.080)
2.0 (0.080)
Fig.
8
8
8
8
Figure 9
A
B
Lead size
Ø 0.81 (0.032)
20 AWG
D
C
Part
number
BBR550
BBR750
IH
(A)
0.55
0.75
IT
(A)
1.1
1.5
V max.
(Vdc)
99
99
I max.
(A)
20
20
R min.
(Ω)
0.80
0.40
R max.
(Ω)
1.30
0.75
R1 max.
(Ω)
1.95
1.20
Agency
recognition
UL, CSA
UL, CSA
These products are intended for telecom applications. For continuous line voltage applications, see LVR product line. Please see the Raychem Circuit Protection Databook for
application details.
Part
number
BBR550
BBR750
Dimensions (millimeters/inches)
A
B
(max.)
(max.)
10.9 (0.43)
14.0 (0.55)
11.9 (0.47)
15.5 (0.61)
C
(nom.)
5.80 (0.23)
5.80 (0.23)
D
(min.)
7.6 (0.3)
7.6 (0.3)
8
Fig.
9
9
Fig.
9
9
S U R F A C E - M O U N T D E V I C E S F O R E L E C T R O N I C A P P L I C AT I O N S
These product lines are designed for surface-mount
applications. The variety of sizes enables installation
in limited space applications such as crowded printed
circuit boards, digital cameras, PC cards, subnotebook
computers, computer peripheral equipment, and
general electronics. These devices are designed for
applications where such space is constrained and
resettable circuit protection is desired.
Figure 1
D
E
D
E
C
A
Top view
nanoSMDC Series Size: 3216 (mm), 1206 (mils)
Agency
recognition
Dimensions (millimeters/inches)
A
B
C
(max.)
(max.)
(max.)
D
(min.)
E
(min.)
6.50
Pending
3.4 (0.134)
1.00 (0.039)
1.8 (0.071)
0.25 (0.010)
0.076 (0.003)
1
1.10
5.00
Pending
3.4 (0.134)
1.00 (0.039)
1.8 (0.071)
0.25 (0.010)
0.076 (0.003)
1
100
0.65
2.60
UL, TÜV, CSA
3.4 (0.134)
0.64 (0.025)
1.8 (0.071)
0.25 (0.010)
0.076 (0.003)
1
20
0.45
1.40
UL, TÜV, CSA
3.4 (0.134)
0.64 (0.025)
1.8 (0.071)
0.25 (0.010)
0.076 (0.003)
1
13.2
100
0.20
0.80
UL, TÜV, CSA
3.4 (0.134)
0.64 (0.025)
1.8 (0.071)
0.25 (0.010)
0.076 (0.003)
1
1.50
6
100
0.12
0.40
UL, TÜV, CSA
3.4 (0.134)
0.48 (0.019)
1.8 (0.071)
0.25 (0.010)
0.076 (0.003)
1
1.10
2.20
6
100
0.07
0.20
UL, TÜV, CSA
3.4 (0.134)
1.00 (0.039)
1.8 (0.071)
0.25 (0.010)
0.076 (0.003)
1
1.50
3.00
6
100
0.04
0.11
UL, TÜV, CSA
3.4 (0.134)
0.89 (0.035)
1.8 (0.071)
0.25 (0.010)
0.076 (0.003)
1
2.00
4.00
6
100
0.02
0.07
Pending
3.4 (0.134)
1.25 (0.049)
1.8 (0.071)
0.25 (0.010)
0.076 (0.003)
1
IT
Rmin
(Ω)
R1 max.
(Ω)
30
10
1.40
0.40
30
10
0.20
0.42
24
nanoSMDC035F
0.35
0.75
16
nanoSMDC050F/13.2
0.50
1.10
nanoSMDC075F
0.75
nanoSMDC110F
nanoSMDC150F
IH
(A)
(A)
Coming Soon nanoSMDC012F*
0.12
0.30
Coming Soon nanoSMDC016F*
0.16
nanoSMDC020F
Coming Soon nanoSMDC200F*
Side view
ELV Compliant, RoHS Compliant
I max.
(A)
Part
number
B
V max.
(Vdc)
Fig.
* Data is preliminary.
microSMD Series Size: 3225 (mm), 1210 (mils)
ELV Compliant, RoHS Compliant
Agency
recognition
Dimensions (millimeters/inches)
A
B
C
(max.)
(max.)
(max.)
D
(min.)
E
(min.)
50.0
UL, TÜV, CSA
3.43 (0.135)
0.85 (0.034)
2.80 (0.110)
0.25 (0.010)
0.20 (0.008)
1
2.10
15.00
UL, TÜV, CSA
3.43 (0.135)
0.85 (0.034)
2.80 (0.110)
0.25 (0.010)
0.20 (0.008)
1
40
0.32
1.30
UL, TÜV, CSA
3.43 (0.135)
0.62 (0.025)
2.80 (0.110)
0.25 (0.010)
0.20 (0.008)
1
13.2
40
0.25
0.90
UL, TÜV, CSA
3.43 (0.135)
0.62 (0.025)
2.80 (0.110)
0.25 (0.010)
0.20 (0.008)
1
1.50
6
40
0.11
0.40
UL, TÜV, CSA
3.43 (0.135)
0.62 (0.025)
2.80 (0.110)
0.25 (0.010)
0.20 (0.008)
1
1.10
2.20
6
40
0.07
0.21
UL, TÜV, CSA
3.43 (0.135)
0.48 (0.019)
2.80 (0.110)
0.25 (0.010)
0.20 (0.008)
1
microSMD150F
1.50
3.00
6
40
0.04
0.11
UL, TÜV, CSA
3.43 (0.135)
1.22 (0.048)
2.80 (0.110)
0.25 (0.010)
0.20 (0.008)
1
New microSMD175F
1.75
3.50
6
40
0.02
0.08
UL, TÜV, CSA
3.43 (0.135)
0.76 (0.030)
2.80 (0.110)
0.25 (0.010)
0.20 (0.008)
1
IT
V max.
(Vdc)
I max.
(A)
Rmin
(Ω)
Part
number
IH
(A)
(A)
microSMD005F
0.05
0.15
30
10
3.6
microSMD010F
0.10
0.25
30
10
microSMD035F
0.35
0.75
6
microSMD050F
0.50
1.00
microSMD075F
0.75
microSMD110F
miniSMDC Series Size: 4532 (mm), 1812 (mils)
R1 max.
(Ω)
Fig.
ELV Compliant, RoHS Compliant
Agency
recognition
Dimensions (millimeters/inches)
A
B
C
(max.)
(max.)
(max.)
D
(min.)
E
(min.)
6.000
UL, TÜV, CSA
4.73 (0.186)
0.89 (0.035)
3.41 (0.134)
0.25 (0.010)
0.20 (0.008)
1
0.600
3.300
UL, TÜV, CSA
4.73 (0.186)
0.89 (0.035)
3.41 (0.134)
0.25 (0.010)
0.20 (0.008)
1
100
0.150
1.000
UL, TÜV, CSA
4.73 (0.186)
0.62 (0.025)
3.41 (0.134)
0.25 (0.010)
0.20 (0.008)
1
100
0.110
0.450
UL, TÜV, CSA
4.73 (0.186)
0.62 (0.025)
3.41 (0.134)
0.25 (0.010)
0.20 (0.008)
1
24
40
0.090
0.290
UL, TÜV, CSA
4.73 (0.186)
1.07 (0.042)
3.41 (0.134)
0.25 (0.010)
0.20 (0.008)
1
2.20
8
100
0.040
0.210
UL, TÜV, CSA
4.73 (0.186)
0.62 (0.025)
3.41 (0.134)
0.25 (0.010)
0.20 (0.008)
1
1.10
2.20
16
100
0.060
0.180
UL, TÜV, CSA
4.73 (0.186)
0.48 (0.019)
3.41 (0.134)
0.25 (0.010)
0.20 (0.008)
1
1.10
2.20
24
20
0.060
0.180
UL, TÜV, CSA
4.73 (0.186)
1.07 (0.042)
3.41 (0.134)
0.25 (0.010)
0.20 (0.008)
1
miniSMDC125F
1.25
2.50
6
100
0.050
0.140
UL, TÜV, CSA
4.73 (0.186)
0.48 (0.019)
3.41 (0.134)
0.25 (0.010)
0.20 (0.008)
1
miniSMDC125F/16
1.25
2.50
16
100
0.050
0.140
UL, TÜV, CSA
4.73 (0.186)
0.48 (0.019)
3.41 (0.134)
0.25 (0.010)
0.20 (0.008)
1
miniSMDC150F
1.50
3.00
6
100
0.040
0.110
UL, TÜV, CSA
4.73 (0.186)
0.48 (0.019)
3.41 (0.134)
0.25 (0.010)
0.20 (0.008)
1
New miniSMDC150F/12
1.50
3.00
12
100
0.040
0.110
UL, TÜV, CSA
4.73 (0.186)
0.48 (0.019)
3.41 (0.134)
0.25 (0.010)
0.20 (0.008)
1
New miniSMDC150F/24
1.50
3.00
24
20
0.040
0.120
UL, TÜV, CSA
4.73 (0.186)
1.50 (0.060)
3.41 (0.134)
0.25 (0.010)
0.20 (0.008)
1
miniSMDC160F
1.60
3.20
9
100
0.030
0.100
UL, TÜV, CSA
4.73 (0.186)
0.48 (0.019)
3.41 (0.134)
0.25 (0.010)
0.20 (0.008)
1
miniSMDC200F
2.00
4.00
8
100
0.020
0.070
UL, TÜV, CSA
4.73 (0.186)
1.22 (0.048)
3.41 (0.134)
0.25 (0.010)
0.20 (0.008)
1
miniSMDC260F
2.60
5.00
6
100
0.015
0.043
UL, TÜV, CSA
4.73 (0.186)
1.25 (0.050)
3.41 (0.134)
0.25 (0.010)
0.20 (0.008)
1
miniSMDC260F/12
2.60
5.00
12
100
0.015
0.047
UL, TÜV, CSA
4.73 (0.186)
1.25 (0.050)
3.41 (0.134)
0.25 (0.010)
0.20 (0.008)
1
2.60
5.00
16
100
0.015
0.047
Pending
4.73 (0.186)
1.25 (0.050)
3.41 (0.134)
0.25 (0.010)
0.20 (0.008)
1
E
(min.)
IT
I max.
(A)
Rmin
(Ω)
R1 max.
(Ω)
60
10
1.500
0.40
30
10
0.50
1.00
24
0.75
1.50
13.2
0.75
1.50
miniSMDC110F
1.10
miniSMDC110F/16
New miniSMDC110F/24
Part
number
IH
(A)
(A)
miniSMDC014F
0.14
0.34
miniSMDC020F
0.20
miniSMDC050F
miniSMDC075F
New miniSMDC075F/24
Coming Soon miniSMDC260F/16*
V max.
(Vdc)
Fig.
* Data is preliminary.
miniSMDE Series Size: 11550 (mm), 4420 (mils)
Part
number
New miniSMDE190F
IT
IH
(A)
(A)
1.90
3.80
V max.
(Vdc)
16
ELV Compliant, RoHS Compliant
I max.
(A)
Rmin
(Ω)
R1 max.
(Ω)
100
0.024
0.080
Agency
recognition
Dimensions (millimeters/inches)
A
B
C
(max.)
(max.)
(max.)
D
(min.)
UL, TÜV, CSA
11.51 (0.453)
0.510 (0.020) 0.381 (0.015)
9
0.53 (0.021)
5.33 (0.210)
Fig.
1
S U R F A C E - M O U N T D E V I C E S F O R E L E C T R O N I C A P P L I C AT I O N S
These product lines are also designed for surfacemount applications. The products range in hold currents from 0.3A to 3.0A and voltages from 6V to 60V.
These devices are suited for high-density board applications in computer and computer peripheral products,
telecommunications, and general electronics applications. They are designed to be reflowed onto a printed
circuit board using standard surface-mount processes.
Figure 2
C
C
B
A
Side view
End view
End view
(midSMD products only)
midSMD Series Size: 5050 (mm), 2018 (mils)
IT
Dimensions (millimeters/inches)
A
B
C
(max.)
(max.)
(max.)
2.30
UL, TÜV, CSA
5.44 (0.214)
1.78 (0.070)
4.93 (0.194)
0.40
1.10
UL, TÜV, CSA
5.31 (0.209)
0.89 (0.035)
4.80 (0.189)
40
0.100
0.40
UL, TÜV, CSA
5.44 (0.214)
1.52 (0.060)
4.93 (0.194)
2
40
0.070
0.18
UL, TÜV, CSA
5.44 (0.214)
1.52 (0.060)
4.93 (0.194)
2
40
0.048
0.10
UL, TÜV, CSA
5.44 (0.214)
1.52 (0.060)
4.93 (0.194)
2
Rmin
(Ω)
R1 max.
(Ω)
60
20
0.500
1.10
60
10
1.10
2.20
15
1.50
3.00
15
2.00
4.20
6
IH
(A)
(A)
SMD030F-2018
0.30
0.80
0.55
SMD100F-2018
SMD150F-2018
SMD200F-2018
New decaSMDC050F/60
Agency
recognition
I max.
(A)
Part
number
V max.
(Vdc)
ELV Compliant, RoHS Compliant
SMD Series Size: 7555 (mm), 2920 (mils)
D
(min.)
E
(min.)
0.25 (0.010)
0.20 (0.008)
2
ELV Compliant, RoHS Compliant
Agency
recognition
Dimensions (millimeters/inches)
A
B
C
(max.)
(max.)
(max.)
Fig.
4.800
UL, TÜV, CSA
7.98 (0.314)
3.18 (0.125)
5.44 (0.214)
2
0.350
1.400
UL, TÜV, CSA
7.98 (0.314)
3.18 (0.125)
5.44 (0.214)
2
40
0.350
1.000
UL, TÜV, CSA
7.98 (0.314)
3.18 (0.125)
5.44 (0.214)
2
60
10
0.350
1.000
UL, TÜV, CSA
7.98 (0.314)
3.18 (0.125)
5.44 (0.214)
2
2.20
30
40
0.120
0.480
UL, TÜV, CSA
7.98 (0.314)
3.00 (0.118)
5.44 (0.214)
2
1.10
2.20
33
40
0.120
0.410
UL, TÜV, CSA
7.98 (0.314)
3.00 (0.118)
5.44 (0.214)
2
New SMDH120
1.20
1.50
16
50
0.150
0.340
Pending
7.98 (0.314)
3.00 (0.118)
5.44 (0.214)
2
SMD125F
1.25
2.50
15
40
0.070
0.250
UL, TÜV, CSA
7.98 (0.314)
3.00 (0.118)
5.44 (0.214)
2
SMD260F
2.60
5.20
6
40
0.025
0.075
UL, TÜV, CSA
7.98 (0.314)
3.00 (0.118)
5.44 (0.214)
2
SMD300F
3.00
6.00
6
40
0.015
0.048
UL, TÜV, CSA
7.98 (0.314)
3.00 (0.118)
5.44 (0.214)
2
IT
I max.
(A)
Rmin
(Ω)
R1 max.
(Ω)
60
10
1.20
1.00
60
10
0.75
1.50
30
SMD075F/60
0.75
1.50
SMD100F
1.10
SMD100F/33
Part
number
IH
(A)
(A)
SMD030F
0.30
0.60
SMD050F
0.50
SMD075F
V max.
(Vdc)
SMD2 Series Size: 8763 (mm), 3425 (mils)
IT
ELV Compliant, RoHS Compliant
Agency
recognition
Dimensions (millimeters/inches)
A
B
C
(max.)
(max.)
(max.)
Fig.
0.250
UL, TÜV, CSA
9.40 (0.370)
3.00 (0.118)
6.71 (0.264)
2
0.080
0.230
UL, TÜV, CSA
9.40 (0.370)
3.00 (0.118)
6.71 (0.264)
2
0.050
0.150
Pending
9.40 (0.370)
3.00 (0.118)
6.71 (0.264)
2
40
0.065
0.165
UL, TÜV, CSA
9.40 (0.370)
3.00 (0.118)
6.71 (0.264)
2
15
40
0.050
0.125
UL, TÜV, CSA
9.40 (0.370)
3.00 (0.118)
6.71 (0.264)
2
15
40
0.035
0.085
UL, TÜV, CSA
9.40 (0.370)
3.00 (0.118)
6.71 (0.264)
2
I max.
(A)
Rmin
(Ω)
R1 max.
(Ω)
15
40
0.060
3.00
33
40
3.20
16
70
1.80
3.60
33
SMD200F
2.00
4.00
SMD250F
2.50
5.00
Part
number
IH
(A)
(A)
SMD150F
1.50
3.00
SMD150F/33
1.50
SMDH160
1.60
SMD185F
V max.
(Vdc)
10
Fig.
1
D E V I C E S F O R B AT T E R Y PA C K A P P L I C AT I O N S
VLR: 85˚C Typical Activation
ELV Compliant, RoHS Compliant
This product line is designed for battery
pack applications. Several material platforms are available to help meet the specific protection needs of different cell
chemistries (e.g. Li-ion, NiMH, and NiCd).
A variety of space efficient form factors
helps the designer minimize pack size.
Part
number
VLR170F
VLR170L†
VLR170UF
VLR175F
VLR175LF
VLR175UF
VLR230F
VLR230-C36†
VLR230S†
VLR230SU†
VLR230UF
IH*
(A)
1.7
1.7
1.7
1.75
1.75
1.75
2.3
2.3
2.3
2.3
2.3
IT
(A)
4.1
4.1
4.1
4.2
4.2
4.2
5
5
5
5
5
Figure 1
Slit: 0.5 mm x 4.0 mm nom.
.02 in x .16 in
C
C
A
A
Top View
I max.
(A)
100
100
100
100
100
100
100
100
100
100
100
Top View
Side View
R max. initial
(Ω)
0.032
0.032
0.032
0.031
0.031
0.031
0.018
0.018
0.018
0.018
0.018
Agency
recognition
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
C
B
B
B
V max.
(Vdc)
12
12
12
12
12
12
12
12
12
12
12
Figure 3
Figure 2
A
Side View
Top View
Dimensions (millimeters/inches)
A
B
(max.)
(max.)
23.2 (0.913)
3.9 (0.153)
41.2 (1.622)
3.9 (0.153)
23.2 (0.913)
3.7 (0.146)
24.5 (0.965)
3.3 (0.130)
31.7 (1.248)
3.3 (0.130)
24.5 (0.96)
3.1 (0.12)
23.1 (0.909)
5.3 (0.208)
27.7 (1.091)
3.9 (0.153)
23.1 (0.909)
5.3 (0.208)
23.1 (0.909)
5.1 (0.201)
23.1 (0.909)
5.1 (0.201)
C
(max.)
0.8 (0.032)
0.8 (0.032)
0.7 (0.028)
0.8 (0.032)
0.8 (0.032)
0.7 (0.028)
0.8 (0.032)
0.8 (0.032)
0.8 (0.032)
0.7 (0.028)
0.7 (0.028)
Side View
Fig.
1
1
3
1
1
3
1
1
2
2
3
* Hold current @ 25°C.
† Please contact Raychem Circuit Protection for RoHS compliant version.
VLP: 90˚C Typical Activation
ELV Compliant, RoHS Compliant
Providing both overcurrent and overtemperature
protection, the low-resistance characteristics of the
VLP devices help battery pack designers lower pack
impedance. In addition, the VLP devices narrow,
low-profile form factor and axial leads allow them
to be welded directly to battery cells, conserving
valuable space in portable electronics applications.
Part
number
VLP210†
VLP220F
VLP270F
IH*
(A)
2.1
2.2
2.7
IT
(A)
5
5.3
6.5
V max.
(Vdc)
16
16
16
Figure 4
Figure 5
A
C
A
B
B
Top View
I max.
(A)
60
60
60
C
Side View
R max. initial
(Ω)
0.030
0.029
0.018
Agency
recognition
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
* Hold current @ 25°C.
† Please contact Raychem Circuit Protection for RoHS compliant version.
11
Top View
Side View
Dimensions (millimeters/inches)
A
B
(max.)
(max.)
17.5 (0.689)
7.3 (0.287)
23.3 (0.917)
3.9 (0.154)
23.1 (0.909)
5.3 (0.208)
C
(max.)
0.8 (0.032)
0.8 (0.032)
0.8 (0.032)
Fig.
4
5
5
D E V I C E S F O R B AT T E R Y PA C K A P P L I C AT I O N S
VTP: 90˚C Typical Activation
ELV Compliant, RoHS Compliant
Figure 6
The conductive polymer composite in
the VTP battery overcurrent protection
devices helps provide increased safety
with extended battery run time. These
devices reach a high-resistance state
at lower temperatures in NiMH and
rechargeable lithium temperaturesensitive chemistries.
Figure 7
A
Figure 8
C
A
B
A
B
Top View
Side View
Top View
Slit: 0.5 mm x 4.0 mm nom.
.02 in x .16 in
IT
(A)
2.7
3.4
3.4
3.4
3.6
3.6
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
5.9
A
V max.
(Vdc)
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
I max.
(A)
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
Top View
Side View
R max. initial
(Ω)
0.070
0.052
0.052
0.052
0.051
0.051
0.039
0.039
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.026
C
B
B
Top View
IH*
(A)
1.1
1.7
1.7
1.7
1.75
1.75
2.0
2.0
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.4
C
A
B
Side View
Figure 11
Slit: 0.5 mm x 4.0 mm nom.
.02 in x .16 in
C
A
Part
number
VTP110F
VTP170F
VTP170X†
VTP170XSF
VTP175LF
VTP175UF
VTP200GF
VTP200U†
VTP210GF
VTP210LF
VTP210SF
VTP210SLF
VTP210SL-19.2/5.8†
VTP210SSF
VTP210ULD†
VTP240F
Top View
Side View
Figure 10
Figure 9
C
B
Agency
recognition
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
Side View
Top View
Dimensions (millimeters/inches)
A
B
(max.)
(max.)
25.6 (1.007)
2.9 (0.114)
17.5 (0.689)
7.4 (0.292)
22.9 (0.90)
5.3 (0.21)
22.9 (0.90)
5.3 (0.21)
28.0 (1.10)
3.9 (0.15)
23.2 (0.91)
3.7 (0.15)
23.1 (0.91)
4.5 (0.18)
23.1 (0.91)
4.3 (0.17)
23.1 (0.91)
5.3 (0.21)
26.0 (1.02)
5.3 (0.21)
23.1 (0.91)
5.3 (0.21)
32.0 (1.26)
5.3 (0.21)
37.0 (1.46)
5.3 (0.21)
23.1 (0.91)
5.3 (0.21)
25.2 (1.00)
5.1 (0.20)
26.2 (1.03)
5.3 (0.21)
Side View
C
(max.)
0.7 (0.028)
0.8 (0.03)
0.8 (0.03)
0.8 (0.03)
0.8 (0.03)
0.7 (0.03)
0.8 (0.03)
0.7 (0.03)
0.8 (0.03)
0.8 (0.03)
0.8 (0.03)
0.8 (0.03)
0.8 (0.03)
0.8 (0.03)
0.8 (0.03)
0.8 (0.03)
Fig.
11
6
8
9
8
11
8
11
8
8
9
9
9
10
11
8
* Hold current @ 25°C.
† Please contact Raychem Circuit Protection for RoHS compliant version.
LTP, miniSMDE: 110˚C Typical Activation
LTP devices help provide reliable,
noncycling protection for rechargeable batteries. LTP devices also
help provide additional protection
at elevated temperatures.
ELV Compliant, RoHS Compliant
Figure 12
Figure 13
A
B
C
Top View
Figure 15
Figure 14
Slit: 0.5 mm x 4.0 mm nom.
.02 in x .16 in
A
C
D
E
Slit: 0.5 mm x 4.0 mm nom.
.02 in x .16 in
A
C
B
D
E
C
B
Side View
Top View
Side View
Top View
Side View
A
Top View
Part
number
LTP
LTP070†
LTP070SF
LTP100F
LTP100SF
LTP100SL†
LTP100SS†
LTP180F
LTP180LF
LTP180S†
LTP190F
LTP260†
LTP300F
LTP340†
miniSMDE
miniSMDE190F
IH
(A)
IT
(A)
0.7
0.7
1.0
1.0
1.0
1.0
1.8
1.8
1.8
1.9
2.6
3.0
3.4
1.9
Agency
recognition
Dimensions (millimeters/inches)
A
B
C
(max.)
(max.)
(max.)
0.200
0.200
0.130
0.130
0.130
0.130
0.068
0.068
0.068
0.057
0.042
0.031
0.027
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
22.1
22.1
23.1
23.1
32.0
23.1
26.0
37.5
26.0
23.4
26.0
31.8
26.0
0.040
UL, TÜV, CSA
11.51 (0.453)
V max.
(Vdc)
I max.
(A)
R max. initial
(Ω)
1.45
1.45
2.5
2.5
2.5
2.5
3.8
3.8
3.8
4.2
5.2
6.3
6.8
15
15
24
24
24
24
24
24
24
24
24
24
24
100
100
100
100
100
100
100
100
100
100
100
100
100
3.8
16
100
† Please contact Raychem Circuit Protection for RoHS compliant version.
12
(0.87)
(0.87)
(0.91)
(0.91)
(1.26)
(0.91)
(1.02)
(1.48)
(1.02)
(0.92)
(1.02)
(1.25)
(1.02)
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
11.0
11.9
13.5
15.9
(0.20)
(0.20)
(0.20)
(0.20)
(0.20)
(0.20)
(0.20)
(0.20)
(0.20)
(0.43)
(0.47)
(0.53)
(0.63)
0.53 (0.021)
B
Side View
Fig.
(0.048)
(0.048)
(0.04)
(0.04)
(0.04)
(0.04)
(0.04)
(0.04)
(0.04)
(0.04)
(0.04)
(0.04)
(0.04)
12
13
12
13
13
14
12
12
13
12
12
12
12
5.33 (0.21)
15
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.1
1.0
1.1
1.0
D E V I C E S F O R B AT T E R Y PA C K A P P L I C AT I O N S
LR4, SRP: 120˚C Typical Activation
The LR4 devices’ smaller thermal mass
means reduced reaction time to overcurrent events. The LR4 devices are
suited for battery packs intended for
computer and camcorder applications.
The SRP products help provide reliable,
non-cycling protection for rechargeable
batteries. Weldable nickel leads and a
narrow, low-profile design make these
devices easy to install directly onto
battery cells.
ELV Compliant, RoHS Compliant
Figure 16
Figure 18
Figure 17
Slit: 0.5 mm x 4.0 mm nom.
.02 in x .16 in
A
Top View
B
Top View
Side View
Slit: 0.5 mm x 4.0 mm nom.
.02 in x .16 in
A
B
B
C
Top View
C
C
Top View
Side View
Side View
Figure 21
Slit: 0.5 mm x 4.0 mm nom.
.02 in x .16 in
A
B
Top View
Side View
Side View
Agency
recognition
Dimensions (millimeters/inches)
A
B
C
(max.)
(max.)
(max.)
0.078
0.072
0.072
0.042
0.042
0.026
0.026
0.020
0.016
0.014
0.014
0.012
0.0105
0.010
0.0065
0.005
UL
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
21.0
22.1
22.1
23.1
23.1
26.0
35.8
26.0
37.0
26.0
42.7
29.1
65.2
47.6
66.5
60.0
(0.83)
(0.87)
(0.87)
(0.91)
(0.91)
(1.02)
(1.41)
(1.02)
(1.46)
(1.02)
(1.68)
(1.15)
(2.57)
(1.874)
(2.62)
(2.36)
4.0
5.5
5.5
5.5
5.5
7.5
5.5
10.5
7.5
14.5
7.5
14.5
8.5
8.5
10.0
14.0
(0.16)
(0.22)
(0.22)
(0.22)
(0.22)
(0.30)
(0.22)
(0.41)
(0.30)
(0.57)
(0.30)
(0.57)
(0.33)
(0.335)
(0.39)
(0.55)
0.7
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.3
1.3
1.3
(0.03)
(0.04)
(0.04)
(0.04)
(0.04)
(0.04)
(0.04)
(0.04)
(0.04)
(0.04)
(0.04)
(0.04)
(0.04)
(0.05)
(0.05)
(0.05)
18
16
17
16
17
16
16
16
16
16
16
16
17
16
17
16
0.160
0.160
0.160
0.090
0.090
0.090
0.090
0.060
0.031
0.024
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
UL, TÜV, CSA
22.1
27.1
22.1
23.1
32.1
23.1
23.1
23.4
31.8
32.4
(0.87)
(1.07)
(0.87)
(0.91)
(1.26)
(0.91)
(0.91)
(0.92)
(1.25)
(1.28)
5.2
5.2
5.2
5.2
5.2
5.2
5.2
11.0
13.5
13.6
(0.20)
(0.20)
(0.20)
(0.20)
(0.20)
(0.20)
(0.20)
(0.43)
(0.53)
(0.54)
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.1
1.1
1.1
(0.04)
(0.04)
(0.04)
(0.04)
(0.04)
(0.04)
(0.04)
(0.04)
(0.04)
(0.04)
19
19
20
19
19
20
21
19
19
19
IH
(A)
IT
(A)
V max.
(Vdc)
I max.
(A)
R max. initial
(Ω)
1.7
1.9
1.9
2.6
2.6
3.8
3.8
4.5
5.5
6.0
6.0
7.3
8.8
9.0
13.0
14.1
3.4
3.9
3.9
5.8
5.8
8.3
8.3
8.9
10.5
11.7
11.7
14.1
16
16.7
21.2
26.2
15
15
15
15
15
15
15
20
20
20
20
20
20
20
20
20
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
2.7
2.7
2.7
3.8
3.8
3.8
3.8
4.4
6.3
7.6
15
15
15
15
15
15
15
30
30
30
100
100
100
100
100
100
100
100
100
100
1.2
1.2
1.2
1.75
1.75
1.75
1.75
2.0
3.5
4.2
Top View
Side View
Figure 20
Figure 19
C
C
B
B
A
Part
number
LR4
LR4-170UF
LR4-190F
LR4-190S†
LR4-260F
LR4-260SF
LR4-380F
LR4-380X†
LR4-450F
LR4-550F
LR4-600F
LR4-600X†
LR4-730F
LR4-880SS†
LR4-900F
LR4-1300SSF
LR4-1410†
SRP
SRP120F
SRP120L†
SRP120SF
SRP175F
SRP175LF
SRP175SF
SRP175SS†
SRP200F
SRP350F
SRP420F
A
A
C
† Please contact Raychem Circuit Protection for RoHS compliant version.
13
Fig.
Definitions
Voltage Rating for Telecom Devices
Agency approvals for PolySwitch devices:
IH = Hold current—maximum current at which the
device will not trip under specified conditions at
20°C unless otherwise specified.
For Raychem Circuit Protection telecom
devices (TC, TGC, TRx, TSx) there are
two applicable voltage ratings. These are
Vmax. Operating and Vmax. Interrupt. To
help understand the nature of these two
different voltage ratings the following
definitions are provided:
PolySwitch devices, where appropriate,
have been tested and have gained the
following safety agency approvals:
• UL Component Recognition in Category
XGPU2, Thermistor Type Devices
• CSA Component Acceptance Class
9073 32, Thermistors—PTC Type
• TU¨V Rheinland Certification, PTC
Resistors
Imax. = The highest fault current that can safely
be used to trip a PolySwitch device under
specified conditions.
Vmax. = The highest voltage that can safely be
dropped across a PolySwitch device
continuously in its tripped state under specified
fault conditions.
R1max. = Maximum device resistance under
specified conditions measured 1 hour post trip or
post reflow.
Ramax. = Maximum device resistance under
automotive conditions specified in PS400
measured 1 hour after stress has been removed.
Rmax. Initial = Maximum device resistance
under specified conditions as supplied.
IT = Minimum current at which a device will trip
under specified conditions.
WARNING!
Vmax. Interrupt: Under specified
conditions this is the highest voltage
that can be applied to the device at the
maximum current. Devices have been
designed to trip safely under higher power
level cross conditions, as listed above, to
assist equipment in meeting the
appropriate industry conditions.
Vmax. Operating: For telecom devices
this is the voltage we have used to obtain
component recognition under UL1434.
Most Raychem Circuit Protection devices
(TC, TGC, TRx, TSx) are certified at 60V
but can withstand higher Vmax. TR600 and
TS600 product families are certified at
250V but can withstand higher Vmax.
Interrupt conditions as noted above.
For the purposes of this brochure we have
included in the table of electrical ratings
the more applicable Vmax. Interrupt value.
• Operation beyond maximum ratings or improper
use may result in device damage and possible
electrical arcing and flame.
• These devices are intended for protection
against occasional overcurrent or overtemperature fault conditions, and should not be used
when repeated fault conditions are anticipated.
• TR and TS devices are not intended for continuous utility line voltage such as 120/220V or
240V.
• LVR Product Notes:
1. A PTC device is not a fuse—it is a nonlinear
thermistor that limits current. Because under a
fault condition all PTC devices go into a high
resistance state but not open circuit, hazardous
voltage may be present at PTC locations.
2. The devices are intended for protection
against occasional overcurrent or
overtemperature fault conditions and should not
be used when repeated fault conditions or
prolonged trip events are anticipated.
3. Please refer to the SCD for complete
information and applications limitations, which
can be obtained from product management
(650-361-6900) or the web:
www.circuitprotection.com/lvr/
Standard PolySwitch product families
include, RGEF, RHEF, RTEF, RUEF, RXEF,
LVR, SMDF, nanoSMDF, microSMDF,
miniSMDF, BBRF, LR4F, LTPF, SRPF,
VTPF, VLRF, VLPF, AHRF, AGRF, and
AHS. PolySwitch TS, TR and ASMD
product families offer a selected number of
RoHS compliant parts. In addition, special
devices, such as speaker devices (SPK),
terminal devices (TD) and custom chip
devices, can be manufactured to meet
performance requirements that could be
outside of the performance band of the
standard products listed in this short form
catalog. Please contact a Raychem Circuit
Protection Customer Service representative
to discuss your special product needs.
14
®
®
Worldwide Headquarters
308 Constitution Drive, MS R21/2A
Menlo Park, CA USA 94025-1164
Tel (800) 227-7040
(650) 361-6900
Fax (650) 361-2508
www.circuitprotection.com
www.circuitprotection.com.hk (Chinese)
www.raychem.co.jp/polyswitch (Japanese)
South America
Europe
Asia/Pacific
Argentina
Tel 54-11-4394-5150
Fax 54-11-4326-9985
UK/EIRE/
Nordic Countries
Tel (32) 16-352028
Fax (32) 16-351319
China, Beijing
Tel 86-10-6581-5606
Fax 86-10-6581-5608
Japan
Tel 81-44-900-5110
Fax 81-44-900-5140
China, Guangzhou
Tel 86-20-8330-9933
Fax 86-20-8385-6139
Korea
Tel 82-2-3415-4654
Fax 82-2-3486-1786
Chile
Tel 56-2-209-8211
Fax 56-2-223-1477
Germany/Austria/
Switzerland/
Eastern Europe
Tel (49) 89-6089386
Fax (49) 89-6089394
China, Hong Kong
Tel 852-2738-3401
Fax 852-2735-1185
Colombia
Tel 57-1-218-2460
Fax 57-1-218-2472
France/Benelux/
Italy/Iberia
Tel (33) 1-34202114
Fax (33) 1-34202324
China, Shanghai
Tel 86-21-6485-3288
Fax 86-21-6485-5109
Peru
Tel 51-1-221-4165
Fax 51-1-421-0368
Other Countries
Tel (32) 16-351321
Fax (32) 16-351319
China, Shenzhen
Tel 86755-25154797
Fax 86755-25980419
Uruguay
Tel 59-8-982-2428
Fax 59-8-982-2430
Venezuela
Tel 58-2-242-6475
Fax 58-2-241-8260
India, Bangalore
Tel 91-80-51121776
Fax 91-80-25586039
Malaysia
Tel 6-04-611-2119
Fax 6-04-644-9521
Australia/Philippines
Tel 63-2-848-0171
Fax 63-2-867-8661
Singapore
Tel 65-6416-4205
Fax 65-6484-0661
Taiwan
Tel 886-2-2662-9788
Fax 886-2-2662-4684
Thailand
Tel 66-1-875-5758
Fax 66-2-617-1939
PolySwitch, SiBar, miniSMD, microSMD, and nanoSMD are trademarks of Tyco Electronics Corporation.
All information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their application. Tyco
Electronics Corporation makes no warranties as to the accuracy or completeness of the information, and disclaims any liability regarding its use. Tyco Electronics’ only
obligations are those in the Company’s Standard Terms and Conditions of Sale for this product, and in no case will Tyco Electronics be liable for any incidental, indirect,
or consequential damages arising from the sale, resale, use, or misuse of the product. Specifications are subject to change without notice. In addition, Tyco Electronics
reserves the right to make changes—without notification to Buyer—to materials or processing that do not affect compliance with any applicable specification.
©2005 Tyco Electronics Corporation. Printed in USA. RCP0014.0505.5000
Brazil
Tel 55-11-5181-4788
Fax 55-11-5181-4790