M41T00AUD Serial real-time clock with audio Features ■ ■ Combination real-time clock with audio – Serial RTC based on M41T00 – Audio section provides: – 300mW differential audio amplifier – 256 and 512Hz tone generation – -33 to +12dB gain, 3dB steps (16 steps plus MUTE) Real-time clock details: – Superset of M41T00 – 3.0 to 3.6V operation DFN16 (5mm x 4mm) “D” Suffix ■ – Timekeeping down to 1.7V – Automatic backup switchover circuit – Ultra low 400nA backup current at 3.0V (typ) – Suitable for battery or capacitor backup Audio section – Power amplifier – Provides 300mW into 8Ω (THD+N = 2% (max), fin = 1kHz) – Summing node at audio input On-chip trickle charge circuit for backup capacitor – 400kHz I2C bus – M41T00 compatible register set with counters for seconds, minutes, hours, day, date, month, years, and century – Inverting configuration with summing resistors into the minus (-) terminal – 0dB gain with 10kΩ feedback resistor and 20kΩ input summing resistors – Signal input centered at VDD/2 – – – 1.6VP-P analog input range (max) – 256 or 512 Hz signal multiplexing with analog input to provide audio with beep tones – Volume control, 4-bit register Automatic leap year compensation – HT bit set when clock goes into backup mode – RTC operates using 32,768Hz quartz crystal – Calibration register provides for adjustments of -63 to +126ppm Oscillator supports crystals with up to 40kΩ series resistance, 12.5pF load capacitance – Oscillator fail detect circuit OF bit indicates when oscillator has stopped for four or more cycles – Allows gain adjustment from -33dB to +12dB – 3dB steps – MUTE bit – Audio automatically shuts off in backup mode – December 2007 Differential output amplifier – ■ 0°C to 70°C operation ■ Small DFN16 package (5mm x 4mm) Rev 2 1/44 www.st.com 1 Contents M41T00AUD Contents 1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 2 Pin settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2.1 Pin connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2.2 Pin description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 3 Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 4 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 5 4.1 2-wire bus characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 4.2 Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 4.3 READ mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 4.4 WRITE mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 4.5 Data retention mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 M41T00AUD clock operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 5.1 6 5.1.1 Halt bit operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 5.1.2 Oscillator fail detect operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 5.1.3 Trickle charger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 5.2 Reading and writing the clock registers . . . . . . . . . . . . . . . . . . . . . . . . . . 18 5.3 Priority for IRQ/FT/OUT pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 5.4 Switchover thresholds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 5.5 Trickle charge circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Clock calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 6.1 7 Clock registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Digital calibration (periodic counter correction) . . . . . . . . . . . . . . . . . . . . 24 Audio section operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 7.1 Gain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 7.1.1 7.2 2/44 Gain tolerance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Wake-up time: TWU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 M41T00AUD Contents 8 Initial conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 9 Maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 10 DC and AC parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 11 Package mechanical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 12 Part numbering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 13 Revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 3/44 List of tables M41T00AUD List of tables Table 1. Table 2. Table 3. Table 4. Table 5. Table 6. Table 7. Table 8. Table 9. Table 10. Table 11. Table 12. Table 13. Table 14. Table 15. Table 16. Table 17. Table 18. Table 19. 4/44 Pin description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 List of registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 AC characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 M41T00AUD register map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Priority for IRQ/FT/OUT pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Digital calibration values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 MUTE and GAIN values (VCC = 3.3V and ambient temperature = 25°C). . . . . . . . . . . . . . 30 Initial values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Absolute maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Operating and AC measurement conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Input/output characteristics (25°C, f = 1MHz) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 DC characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Crystal electrical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 RTC power down/up AC characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 RTC power down/up trip points DC characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Audio section electrical characteristics, valid for VCC = 3.3V and TAMB = 25°C (except where otherwise noted)38 DFN16 (5mm x 4mm) package mechanical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Ordering information scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Document revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 M41T00AUD List of figures List of figures Figure 1. Figure 2. Figure 3. Figure 4. Figure 5. Figure 6. Figure 7. Figure 8. Figure 9. Figure 10. Figure 11. Figure 12. Figure 13. Figure 14. Figure 15. Figure 16. Figure 17. Figure 18. Figure 19. Logic diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Pin connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Application diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Typical hookup example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Serial bus data transfer sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Acknowledgement sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Bus timing requirements sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Slave address location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 READ mode sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Alternate READ mode sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 WRITE mode sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Counter update diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Switchover thresholds. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Trickle charge circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Crystal accuracy across temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Audio section diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 AC testing Input/Output waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Power down/up mode AC waveforms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 DFN16 (5mm x 4mm) package outline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 5/44 Description 1 M41T00AUD Description The M41T00AUD is a low power serial real-time clock (RTC) with an integral audio section with tone generator and 300mW output amplifier. The RTC is a superset of the M41T00 with enhancements such as a precision reference for switchover, an oscillator fail detect circuit and storing of the time at power down. The audio section includes a summing amplifier (inverting) at the input. An 8kHz low pass filter follows that with a 16 step programmable gain stage next. A 256 or 512Hz audio tone can be switched into the filter in place of the input signal. From the gain stage, the 300mW amplifier drives the output pins. The M41T00AUD has a built-in power sense circuit which detects power failures and automatically switches to the backup input when VCC is removed. Backup power can be supplied by a capacitor or by a battery such as a Lithium coin cell. The device includes a trickle charge circuit for charging the capacitor. The RTC includes a built-in 32.768kHz oscillator controlled by an external crystal. Eight register bytes are used for the clock/calendar functions and are superset compatible with the M41T00. Two additional registers control the audio section and the trickle charger. The 10 registers (see Table 2) are accessed over a 400kHz I2C bus. The address register increments automatically after each byte READ or WRITE operation thus streamlining transfers by eliminating the need to send a new address for each by to be transferred. Typical data retention times will be in excess of 5 years with a 50mAh 3V lithium cell (see RTC DC characteristics, Table 12 for more information). Figure 1. Logic diagram VCC VBIAS OSCI OSCO IRQ/FT/OUT SCL SDA M41T00AUD AIN VBACK FBK AOUT+ AOUT – NC VSS ai13322 6/44 M41T00AUD Pin settings 2 Pin settings 2.1 Pin connection Figure 2. Pin connection OSCI OSCO VSS VCC IRQ/FT/OUT VBACK SCL SDA 1 2 3 4 5 6 7 8 16 15 14 13 12 11 10 9 AOUT– VCC VSS AOUT+ FBK VBIAS AIN NC ai13323 2.2 Pin description Table 1. Pin description Symbol Name and function VCC Supply voltage OSCI Oscillator input OSCO Oscillator output SCL I2C serial clock SDA I2C serial data AIN Audio input VBIAS Input for decoupling capacitor VSS Ground AOUT– Analog out, 180 phase AOUT+ Analog out, 0 phase IRQ/FT/OUT Interrupt output for oscillator fail detect, frequency test output for calibration, or discrete logic output VBACK Backup supply voltage FBK Feedback; connect feedback resistor between this pin and AIN NC No connection No name; exposed pad on back of IC package Must be connected to ground 7/44 Application 3 M41T00AUD Application Figure 3. Application diagram M41T00AUD VCC VCC AUTOMATIC BATTERY VINT SWITCHOVER & DESELEC T VCC REFERENCE VPFD =2.80V I2C (SDA, SCL) uC I2 C OSCI 32KHz OSCILL ATOR OSCO Audio-in WRITE PROTECT 400kHz I2C INTER FACE 2 VBACK TRICKLE CHARGE SECS MINS HOURS DATE DAY MONTH YEAR CENTURY BIT CALIBRATION OUT OSCILLATOR FAIL DETECT 256/512Hz IRQ/FT/OUT AUDIO ADJ BPF GAIN FBK AIN VSS AOUT+ AOUT– VBIAS ai13324 8/44 M41T00AUD Figure 4. Application Typical hookup example Place near pin 15 1.0μF 15 VCC Place near pin 4 0.1μF 4 VCC 3.3V Either/or, but not both M41T00AUD 6 VBACK TRICKLE CHARGE 3.3V *optional 4.7kΩ 4.7kΩ + BATTERY SWITCHOVER VINT SDA 8 4.7kΩ I2C 5 OSCI 1 R1x 20kΩ FBK 12 R2 10kΩ AIN 10 VDD 2 VDD 2 8Ω or higher 1μF R1x 20kΩ Optional: can sum additional audio inputs 13 AOUT+ 16 AOUT– AUDIO SECTION VSS 14 Set R1’s to 2x R2 for unity gain Optional connection to micro 256/512Hz ONE GEN VSS 3 R1 20kΩ 32KHz OSC PMH Audio In OSCO 2 0.1μF 32.768kHz R2 should be a minimum of 10kΩ IRQ/FT/OUT RTC VBIAS 11 SDA Lithium Cell Battery (alternative) 3.3V SCL 7 SCL 0.22μF (typical) 3.3V Package Metal Heatsink: exposed pad on back of IC package ai13325 9/44 Operation 4 M41T00AUD Operation The M41T00AUD clock operates as a slave device on the serial bus. Access is obtained by implementing a start condition followed by the correct slave address (D0h). The 10 bytes contained in the device can then be accessed sequentially in the following order: Table 2. List of registers Byte address Contents 00h Seconds register 01h Minutes register 02h Century/hours register 03h Day register 04h Date register 05h Month register 06h Years register 07h Calibration/control register 08h Audio register 09h Control2 register The M41T00AUD continually monitors VCC for an out of tolerance condition. Should VCC fall below VPFD, the device terminates an access in progress and resets the device address counter. Inputs to the device will not be recognized at this time to prevent erroneous data from being written to the device from an out of tolerance system. When VCC falls below VSO, the device automatically switches over to the backup battery or capacitor and powers down into an ultra low current mode of operation to conserve battery life. Upon power-up, the device switches from battery to VCC at VSO and recognizes inputs. 10/44 M41T00AUD 4.1 Operation 2-wire bus characteristics This bus is intended for communication between different ICs. It consists of two lines: one bi-directional for data signals (SDA) and one for clock signals (SCL). Both the SDA and the SCL lines must be connected to a positive supply voltage via a pull-up resistor. The following protocol has been defined: ● Data transfer may be initiated only when the bus is not busy. ● During data transfer, the data line must remain stable whenever the clock line is high. Changes in the data line while the clock line is high will be interpreted as control signals. Accordingly, the following bus conditions have been defined: ● Bus not busy. Both data and clock lines remain high. ● Start data transfer. A change in the state of the data line, from high to Low, while the clock is high, defines the START condition. ● Stop data transfer. A change in the state of the data line, from low to high, while the clock is high, defines the STOP condition. ● Data valid. The state of the data line represents valid data when after a start condition, the data line is stable for the duration of the high period of the clock signal. The data on the line may be changed during the low period of the clock signal. There is one clock pulse per bit of data. Each data transfer is initiated with a start condition and terminated with a stop condition. The number of data bytes transferred between the start and stop conditions is not limited. The information is transmitted byte-wide and each receiver acknowledges with a ninth bit. By definition, a device that gives out a message is called "transmitter", the receiving device that gets the message is called "receiver". The device that controls the message is called "master". The devices that are controlled by the master are called "slaves". ● Acknowledge. Each byte of eight bits is followed by one acknowledge bit. This acknowledge bit is a low level put on the bus by the receiver, whereas the master generates an extra acknowledge related clock pulse. A slave receiver which is addressed is obliged to generate an acknowledge after the reception of each byte. Also, a master receiver must generate an acknowledge after the reception of each byte that has been clocked out of the slave transmitter. The device that acknowledges has to pull down the SDA line during the acknowledge clock pulse in such a way that the SDA line is a stable Low during the High period of the acknowledge related clock pulse. Of course, setup and hold times must be taken into account. A master receiver must signal an end-of-data to the slave transmitter by not generating an acknowledge on the last byte that has been clocked out of the slave. In this case, the transmitter must leave the data line High to enable the master to generate the STOP condition. 11/44 Operation M41T00AUD Figure 5. Serial bus data transfer sequence DATA LINE STABLE DATA VALID CLOCK DATA START CONDITION CHANGE OF DATA ALLOWED STOP CONDITION AI00587 Figure 6. Acknowledgement sequence CLOCK PULSE FOR ACKNOWLEDGEMENT START SCLK FROM MASTER 1 DATA OUTPUT BY TRANSMITTER 2 8 MSB 9 LSB DATA OUTPUT BY RECEIVER AI00601 Figure 7. Bus timing requirements sequence SDA tBUF tHD:STA tHD:STA tR tF SCL tHIGH P S tLOW tSU:DAT tHD:DAT tSU:STA SR tSU:ST P AI00589 1. P = STOP and S = START 12/44 M41T00AUD 4.2 Operation Characteristics Table 3. AC characteristics Parameter(1) Symbol Min Typ Max Units 400 kHz fSCL SCL clock frequency tLOW Clock Low period 1.3 µs tHIGH Clock High period 600 ns 0 tR SDA and SCL Rise time 300 ns tF SDA and SCL Fall time 300 ns tHD:STA START condition Hold time (after this period the first clock pulse is generated) 600 ns tSU:STA START condition Setup time (only relevant for a repeated start condition) 600 ns tSU:DAT(2) Data Setup time 100 ns tHD:DAT Data Hold time 0 µs tSU:STO STOP condition Setup time 600 ns Time the bus must be free before a new transmission can start 1.3 µs tBUF 1. Valid for ambient operating temperature: TA = 0 to 70°C; VCC = 3.0 to 3.6V (except where noted). 2. Transmitter must internally provide a hold time to bridge the undefined region (300ns max) of the falling edge of SCL. 4.3 READ mode In this mode, the master reads the M41T00AUD slave after setting the slave address (see Figure 8). Following the WRITE mode control bit (R/W = 0) and the acknowledge bit, the word (register) address An is written to the on-chip address pointer. Next the START condition and slave address are repeated, followed by the READ mode control bit (R/W = 1). At this point, the master transmitter becomes the master receiver. The data byte which was addressed will be transmitted and the master receiver will send an acknowledge bit to the slave transmitter. The address pointer is only incremented on reception of an acknowledge bit. The device slave transmitter will now place the data byte at address An+1 on the bus. The master receiver reads and acknowledges the new byte and the address pointer is incremented to An+2. This cycle of reading consecutive addresses will continue until the master receiver sends a STOP condition to the slave transmitter. An alternate READ mode may also be implemented, whereby the master reads the M41T00AUD slave without first writing to the (volatile) address pointer. The first address that is read is the last one stored in the pointer (see Figure 10). 13/44 Operation Figure 8. M41T00AUD Slave address location R/W SLAVE ADDRESS 1 A LSB MSB START 1 0 1 0 0 0 AI00602 R/W SLAVE ADDRESS DATA n+1 ACK DATA n ACK BUS ACTIVITY: S ACK WORD ADDRESS (An) ACK S R/W SDA LINE ACK BUS ACTIVITY: MASTER START READ mode sequence START Figure 9. STOP SLAVE ADDRESS DATA n+X P NO ACK AI00899 SLAVE ADDRESS P ACK DATA n+X ACK DATA n+1 ACK DATA n BUS ACTIVITY: 14/44 STOP R/W S ACK SDA LINE ACK BUS ACTIVITY: MASTER START Figure 10. Alternate READ mode sequence AI00895 M41T00AUD 4.4 Operation WRITE mode In this mode the master transmitter transmits to the M41T00AUD slave receiver. Bus protocol is shown in Figure 11. Following the START condition and slave address, a logic '0' (R/W = 0) is placed on the bus and indicates to the addressed device that word address An will follow and is to be written to the on-chip address pointer. The data word to be written to the device is strobed in next and the internal address pointer is incremented to the next location within the device on the reception of an acknowledge clock. The M41T00AUD slave receiver will send an acknowledge clock to the master transmitter after it has received the slave address and again after it has received the word address and each data byte (see Figure 8). STOP SLAVE ADDRESS 4.5 DATA n+X P ACK DATA n+1 ACK BUS ACTIVITY: DATA n ACK WORD ADDRESS (An) ACK S R/W SDA LINE ACK BUS ACTIVITY: MASTER START Figure 11. WRITE mode sequence AI00591 Data retention mode With valid VCC applied, the M41T00AUD can be accessed as described above with READ or WRITE cycles. Should the supply voltage decay, the M41T00AUD will automatically deselect, write protecting itself when VCC falls (see Figure 13). 15/44 M41T00AUD clock operation 5 M41T00AUD clock operation 5.1 Clock registers M41T00AUD The 10-byte Register Map (see Table 2) is used to both set the clock and to read the date and time from the clock, in a binary coded decimal format. Seconds, Minutes, and Hours are contained within the first three registers. Bits D6 to D0 or register 00h (seconds register) contain the seconds count in BCD format with values in the range 0 to 59. Bit D7 is the ST or stop bit, described below, and is not affected by the timekeeping operation, but users must avoid inadvertently altering it when writing the seconds register. Setting the ST bit to a 1 will cause the oscillator to stop. If the device is expected to spend a significant amount of time on the shelf, the oscillator may be stopped to reduce current drain on the backup battery. When reset to a 0 the oscillator restarts within one second. In order to ensure oscillator start-up after the initial power-up, set the ST bit to a 1 then write it to 0. This sequence enables the "kick start" circuit which aids the oscillator start-up by temporarily increasing the oscillator current. This will guarantee oscillator start-up under worst case conditions of voltage and temperature. This feature can be employed anytime the oscillator is being started but should not occur on subsequent power-ups when the oscillator is already running. Bits D6 to D0 of register 01h (Minutes Register) contain the minutes count in BCD format with values in the range 0 to 59. Bit D7 always reads 0. Writing it has no effect. Bits D5 to D0 of register 02h (Century/ Hours Register) contain the hours in BCD format with values in the range 0 to 23. Bits D7 and D6 contain the century enable bit (CEB) and the century bit (CB). CB provides a one-bit indicator for the century. The user can apply his preferred convention for defining the meaning of this bit. For example, 0 can mean the current century, and 1 the next, or the opposite meanings may be used. When enabled, CB will toggle every 100 years. Setting CEB to a 1 enables CB to toggle at the turn of the century, either from 0 to 1 or from 1 to 0, depending on its initial state, as programmed by the user. When CEB is a 0, CB will not toggle. Bits D2 through D0 of Register 03h (day register) contain the day of the week in BCD format with values in the range 0 to 7. Bits D3 and D7 will always read 0. Writes to them have no effect. Bits D6, D5 and D4 will power up in an indeterminate state. Register 04h contains the date (day of month) in BCD format with values in the range 01 to 31. Bits D7 and D6 always read 0. Writes to them have no effect. Register 05 h is the Month in BCD format with values in the range 1 to 12. Bits D7, D6 and D5 always read 0. Writes to them have no effect. Register 06h is the years in BCD format with values in the range 0 to 99. Writing to any of the registers 00h to 06h, including the control bits therein, will result in updates to the counters and resetting of the internal clock divider chain including the 256/512Hz tone generator. The updates do not occur immediately after the write(s), but occur upon completion of the current write access. This is described in greater detail in the next section. Registers 07h and 09h also contain clock control and status information. These registers can be written at any time without affecting the timekeeping function. 16/44 M41T00AUD M41T00AUD clock operation Register 08 is the calibration register. Calibration is described in detail in the Clock calibration section. Bit D7 is the OUT bit and controls the discrete output pin IRQ/FT/OUT as described in Table 5. 5.1.1 Halt bit operation Bit D7 of register 09 h is the HT or halt bit. Whenever the device switches to backup power, it sets the HT bit to 1 and stores the time of power down in the transfer buffer registers. This is known as power-down time stamp. During normal timekeeping, once per second, the transfer buffer registers are updated with the current time. When HT is 1, that updating is halted. The clock continues to keep time but the periodic updates do not occur. Upon power up, reads of the clock registers will return the time of power down (assuming adequate backup power was maintained while VCC was off). After the user clears the HT bit by writing it to 0, subsequent reads of the clock registers will return the current time. At power up, the user can read the time of power down, and then clear the HT bit to allow updates. The next read will return the current time. Knowing both the power up time and the power down time allows the user to calculate the duration of power off. In addition to the HT bit getting set to 1 automatically at power down, the user can also write it to 1 to halt updating of the registers. 5.1.2 Oscillator fail detect operation Bits D5 and D4 of register 09 h contain the oscillator fail flag (OF) and the oscillator fail interrupt enable bit (OFIE). If the 32 KHz oscillator drops four or more pulses in a row, as might occur during an extended outage while backed up on a capacitor, the OF bit will be set to 1. This provides an indication to the user of the integrity of the timekeeping operation. Whenever the OF bit is a 1, the system should consider the time to be possibly corrupted due to operating at too low a voltage. The OF bit will always be 1 at the initial power up of the device. The OF bit is cleared by writing it to 0. At the initial power up, users should wait three seconds for the oscillator to stabilize before clearing the OF bit. OFIE can be used to enable the device to assert its interrupt output whenever an oscillator failure is detected. The oscillator fail interrupt will drive the IRQ/FT/OUT pin as described in Table 5. The interrupt is cleared by writing the OF bit to 0. Setting OFIE enables the oscillator fail interrupt. Clearing it to 0 disables it, but the OF will continue to function regardless of OFIE. 5.1.3 Trickle charger Bits D6 and D3 to D0, of register 09h, control the trickle charge function. It is described in detail in the Trickle Charge Circuit section. 17/44 M41T00AUD clock operation 5.2 M41T00AUD Reading and writing the clock registers The counters used to implement the timing chain in the real-time clock are not directly accessed by the serial interface. Instead, as depicted in Figure 12, reads and writes are buffered through a set of transfer registers. This ensures coherency of the timekeeping function. During writes of the timekeeping registers (00h to 06h), the write data is stored in the buffer transfer registers until all the data is written, then the register contents are simultaneously transferred to the counters thus updating them. The update is triggered either by a STOP condition or by a write to one of the non RTC registers, 07h to 09h. If any of the buffer transfer registers are not written, then the corresponding counters are not updated. Instead, those counters will retain their previous contents when the update occurs. Similar to the writes, reads access the buffer transfer registers. The device periodically updates the registers with the counter contents. But during reads, the updates are suspended. Timekeeping continues, but the registers are frozen until after a STOP condition or a non RTC register (07h to 09h) is read. Suspending the updates ensures that a clock roll-over does not occur during a user read cycle. The seven clock registers may be read one byte at a time, or in a sequential block. The calibration, audio and Control2 registers, location 07 h to 09 h, may be accessed independently. Provision has been made to ensure that a clock update does not occur while any of the seven clock addresses are being read. During a clock register read (addresses 00h to 06h), updates of the clock transfer buffer registers are halted. The clock counters continue to keep time, but the contents of the transfer buffer registers is frozen at the time that the read access began. This prevents a transition of data during the READ. For example, without the halt function, if the time incremented past midnight in the middle of an access sequence, the user might begin reading at 11:59:59pm and finish at 12:00:00am. The data read might appear as 12:59:59 because the seconds and minutes were read before midnight while the hours were read after. The device prevents this by halting the updates of the registers until after the read access has occurred. 18/44 M41T00AUD M41T00AUD clock operation M41T00AUD register map(1) Table 4. Bit Addr D7 00h ST 10 seconds 01h 0 (2) 10 minutes 02h CEB CB 03h 0 Y(3) 04h 0 0 05h 0 0 06h D6 D5 D4 10 hours Y Register name Range Seconds Seconds 00-59 Minutes Minutes 00-59 Hours (24 hour format) Century/hours 0-1/00-23 Day 1-7 Date: day of month Date 01-31 Month Month 01-12 Year Year 00-99 D3 Y D2 0 10M 10 years 07h OUT FT S 08h 256/512 TONE TCH2 MUTE 09h HT TCFE OF OFIE D0 Day of week 10 date 0 D1 <------------- Calibration ------------> <--------------GAIN ------------> TCHE3 TCHE2 TCHE1 TCHE0 Cal/control Audio Control2 1. Key: S = SIGN bit FT = Frequency Test bit' ST = STOP bit OF = Oscillator Fail Detect Flag OFIE = Oscillator Fail Interrupt Enable OUT = Logic Output TCHE3:TCHEO = Trickle Charge Enable bits TCFE = Trickle Charge FET bypass Enable HT = Halt bit TCH2 = Trickle Charge Enable #2 TONE = Tone on/off select CB = Century bit CEB = Century Enable bit 256/512 = Tone frequency select bit 2. 0 bits always read as 0. Writing them has no effect. 3. Y bits are indeterminate at power-up. These are the factory test mode bits, and must be written to 0. 19/44 M41T00AUD clock operation M41T00AUD Figure 12. Counter update diagram 32KHz OSC READ/WRITE BUFFER TRANSFER REGISTERS REGISTER REGISTER 12C SERIAL BUS SERIAL TRANSFER REGISTER REGISTER REGISTER REGISTER REGISTER REGISTER DIVIDE BY 32768 1 Hz SECONDS MINUTES HOURS DAY DATE MONTHS YEARS CENTURIES COUNTER COUNTER COUNTER COUNTER COUNTER COUNTER COUNTER ai13329 20/44 M41T00AUD 5.3 M41T00AUD clock operation Priority for IRQ/FT/OUT pin Three functions share pin 5 of the M41T00AUD. The oscillator fail interrupt (IRQ), the calibration frequency test output (FT) and the discrete logic output (OUT) all use this pin. In normal operation, when operating from VCC, the interrupt function has priority over the frequency test function which in turn has priority over the discrete output function. In the backup mode, when operating from VBACK, the priorities are different. The interrupt and frequency test functions are disabled, and only the discrete output function can be used. When operating from VCC, if the oscillator fail interrupt enable bit is set (OFIE, D4 of register 09h), the pin is an interrupt output which will be asserted anytime the OF bit (D5 of register 09h) goes true. (See Section 5 for more details.) During calibration, the pin can be used as a frequency test output. When FT is a 1 (and OFIE a 0), the device will output a 512Hz test signal on this pin. Users can measure this with a frequency counter and use that result to determine the appropriate calibration register value. Otherwise, when OFIE is a 0 and FT is a 0, it becomes the discrete logic OUT pin and reflects the value of the OUT bit (D7 of register 07h). When operating from VBACK, the discrete output function can still be used. The IRQ/FT/OUT pin will reflect the contents of the out bit. Note: The IRQ/FT/OUT pin is open drain and requires an external pull-up resistor. Table 5. Priority for IRQ/FT/OUT pin Register bits State On VCC On VBACK IRQ/FT/OUT pin OFIE FT OUT 1 X X OF 0 1 X 512 Hertz 0 0 1 1 0 0 0 0 X X 1 1 X X 0 0 21/44 M41T00AUD clock operation 5.4 M41T00AUD Switchover thresholds While the M41T00AUD includes a precision reference for the backup switchover threshold, it is not a fixed value, but depends on the backup voltage, VBACK. The device will always switchover at the lesser of the reference voltage (VPFD, approximately 2.8V) and VBACK. This ensures that it stays on VCC as long as possible before switching to the backup supply. As shown in Figure 13, whenever VBACK is greater than VPFD, switchover occurs when VCC drops below VPFD. Conversely, when VBACK is less than VPFD, switchover occurs when VCC drops below VBACK. Table 14 provides the values of these voltages. Figure 13. Switchover thresholds Condition 1: VBACK > 2.8V (VPFD) VCC (= 3.3V) VBACK (> VPFD) Switchover voltage VSO = VPFD (= 2.8V) STATE On VCC On VBACK On VCC Condition 2: VBACK < 2.8V (VPFD) VCC (= 3.3V) VPFD = 2.8V Switchover voltage VSO = VBACK (< VPFD) STATE On VCC On VBACK On VCC ai13326 22/44 M41T00AUD 5.5 M41T00AUD clock operation Trickle charge circuit The M41T00AUD includes a trickle charge circuit to be used with a backup capacitor. It is illustrated in Table 14. VBACK is a bi-directional pin. Its primary function is as the backup supply input. (The input nature is not depicted in the figure.) The trickle charge output function is a secondary capability, and reduces the need for external components. To enable trickle charging, two switches must be closed. A diode is present to prevent current from flowing backwards from VBACK to VCC. A current limiting resistor is also in the path. An additional switch allows the diode to be bypassed through a 20k resistor. This should charge the capacitor to a higher level thus extending backup life. This switch automatically opens when the device switches to backup thus preventing capacitor discharge to VCC. Furthermore, at switchover to backup, the other switches open as well. The application must close them after power up to re-enable the trickle charge function. The use of two switches in the chain is to protect against accidental, unwanted charging as might be the case when using battery backup. Additionally, one of the two switches requires four bits to be changed from the default value before it will close. This prevents single bit errors from closing the switch. The four bits, TCHE3:TCHE0, reside in register 09h at bits D3 to D0. The control bit for the second switch, TCH2, resides in register 08h at bit D5. With this bit in a separate register, two bytes must be written before charging will occur, again protecting against inadvertent charging due to errors. The control bit for the bypass switch, TCFE, resides in register 09h at bit D6. To enable trickle charging, the user must set TCHE3:TCHE0 to 5h, and TCH2 to 1. To bypass the diode, TCFE must be set to 1. All three fields must be enabled after each power up. Figure 14. Trickle charge circuit TCFE VCC TCFE = 0 OPEN 20 Ω TCH2 TCHE TCHE/ = 5h OPEN TCHE = 5h CLOSED TCH2 = 0 OPEN TCH2 = 1 CLOSED TCFE=1 CLOSED 940 Ω VBACK 180 Ω ai13327 23/44 Clock calibration 6 M41T00AUD Clock calibration The M41T00AUD oscillator is designed for use with a 12.5pF crystal load capacitance. With a nominal ±20 ppm crystal, the M41T00AUD will be accurate to ±35 ppm. When the calibration circuit is properly employed, accuracy improves to better than ±2 ppm at 25°C. The M41T00AUD design provides the following method for clock error correction. 6.1 Digital calibration (periodic counter correction) This method employs the use of periodic counter correction by adjusting the number of cycles of the internal 512Hz signal counted in a second. By adding an extra cycle, for 513, a long second is counted for slowing the clock. By reducing it to 511 cycles, a short second is counted for speeding up the clock. Not every second is affected. The calibration value (bits D4-D0 of register 07h) and its sign bit (D5 of same register) control how often a short or long second is generated. The basic nature of a 32KHz crystal is to slow down at temperatures above and below 25°C. Whether the temperature is above or below 25°C, the device will tend to run slow. Therefore, most corrections will need to speed the clock up. Hence, the M41T00AUD calibration circuit uses a non-symmetric calibration scheme. Positive values, for speeding the clock up, have more effect than negative values, for slowing it down. A positive value will speed the clock up by approximately 4ppm per step. A negative value will slow it by approximately 2ppm per step. In the M41T00AUD's calibration circuit, positive correction is applied every 8th minute whereas negative correction is applied every 16th minute. Because positive correction is applied twice as often, it has twice the effect for a given calibration number, N. When the calibration sign bit is positive, N seconds of every 8th minute will be shortened to 511 cycles of the 512Hz clock. When the calibration sign bit is negative, N seconds of every 16th minute will be lengthened to 513 cycles of the 512Hz clock. When N is positive, one minute will have N seconds which are 511 cycles and the remaining seconds will be 512 cycles. The next seven minutes are nominal with all seconds 512 cycles each. Example 1: Sign is 1 and N is 2 (00010b) The 8-minute interval will be: 2 * 511 + (60-2) * 512 + 7 * 60 * 512 = 245758 cycles long out of a possible 512 * 60 * 8 = 245760 cycles of the 512Hz clock in an 8-minute span. This gives a net correction of (245760-245758) / 245760 = -8.138ppm When N is negative, one minute will have N seconds which are 513 cycles and the remaining seconds will be 512 cycles. The next 15 minutes are nominal with all seconds 512 cycles each 24/44 M41T00AUD Clock calibration Example 2: Sign is 0 and N is 3 (00010b). The 16-minute interval will be: 3 * 513 + (60-3) * 512 + 15 * 60 * 512 = 491523 cycles long out of a possible 512 * 60 * 16 = 491520 cycles of the 512Hz clock in an 16-minute span. This gives a net correction of (491520-491523) / 491520 = +6.104ppm Therefore, each calibration step has an effect on clock accuracy of either -4.068 or +2.034 ppm. Assuming that the oscillator is running at exactly 32,768Hz, each of the 31 steps in the calibration byte would represent subtracting 10.7 or adding 5.35 seconds per month, which corresponds to a total range of -5.5 or +2.75 minutes per month. Note: The modified pulses are not observable on the frequency test (FT) output, nor will the effect of the calibration be measurable real-time, due to the periodic nature of the error compensation. 25/44 Clock calibration M41T00AUD Table 6. Digital calibration values Calibration value DC4-DC0 Decimal Binary Slowing sign DCS = 0 Speeding sign DCS = 1 0 00000 + 0 ppm – 0 ppm 1 00001 + 2 ppm – 4 ppm 2 00010 + 4 ppm – 8 ppm 3 00011 + 6 ppm – 12 ppm 4 00100 + 8 ppm – 16 ppm 5 00101 + 10 ppm – 20 ppm 6 00110 + 12 ppm – 24 ppm 7 00111 + 14 ppm – 28 ppm 8 01000 + 16 ppm – 33 ppm 9 01001 + 18 ppm – 37 ppm 10 01010 + 20 ppm – 41 ppm 11 01011 + 22 ppm – 45 ppm 12 01100 + 24 ppm – 49 ppm 13 01101 + 26 ppm – 53 ppm 14 01110 + 28 ppm – 57 ppm 15 01111 + 31 ppm – 61 ppm 16 10000 + 33 ppm – 65 ppm 17 10001 + 35 ppm – 69 ppm 18 10010 + 37 ppm – 73 ppm 19 10011 + 39 ppm – 77 ppm 20 10100 + 41 ppm – 81 ppm 21 10101 + 43 ppm – 85 ppm 22 10110 + 45 ppm – 90 ppm 23 10111 + 47 ppm – 94 ppm 24 11000 + 49 ppm – 98 ppm 25 11001 + 51 ppm – 102 ppm 26 11010 + 53 ppm – 106 ppm 27 11011 + 55 ppm – 110 ppm 28 11100 + 57 ppm – 114 ppm 29 11101 + 59 ppm – 118 ppm 30 11110 + 61 ppm – 122 ppm 31 11111 + 63 ppm – 126 ppm +N/491520 (per minute) –N/245760 (per minute) N 26/44 Calibration result, in ppm, rounded to the nearest integer M41T00AUD Clock calibration Figure 15. Crystal accuracy across temperature Frequency (ppm) 20 0 –20 –40 –60 –80 DF = K x (T –T )2 O F –100 K = –0.036 ppm/˚C2 ± 0.006 ppm/˚C2 –120 TO = 25˚C ± 5˚C –140 –160 –40 –30 –20 –10 0 10 20 30 40 50 60 70 80 Temperature °C AI00999b 27/44 Audio section operation 7 M41T00AUD Audio section operation The audio section is comprised of five main parts. The input includes a summing amplifier. A minimum 10kΩ feedback resistor is required. With that and 20kΩ input resistors, the input signals will be summed at unity gain. An audio switch follows the amplifier. A tone, selectable between 256 and 512 Hz, can be inserted into the audio stream in lieu of the input amplifier's output. A low pass filter is next with a cut off of 8 kHz. To get a band pass with a 100 Hz low end, the user should place an appropriate coupling capacitor at the input pin. 28/44 0.1μF Set R1’s to 2x R2 for unity gain AIN R2 10kΩ FBK VDD 2 VDD From internal RTC timing chain Sum multiple audio signals through external resistors, but single input R1x 20kΩ R1 20kΩ SIN R2 should be a minimum of 10kOhm 512Hz 256Hz 256/512 SELECT 100Hz - 8kHz BPF Switch 256/512 signal in place of audio signal VBIAS GAIN, 3dB steps, –33dB to +12dB (4-bit register) Low end of band pass filter is actually implemented by blocking capacitor at input pin. Only the high end (low-pass section) is implemented at this point in the audio section. TONE ON/OFF register bits 1μF VDD 2 ai13328 AOUT– 300mW @ 8Ω AOUT+ M41T00AUD Audio section operation Figure 16. Audio section diagram 29/44 Audio section operation Table 7. M41T00AUD MUTE and GAIN(1) values (VCC = 3.3V and ambient temperature = 25°C) MUTE GAIN Audio gain (dB) Min Binary Hex 1 XXXX X Off Off 0 1111 F +12 4 0 1110 E 0 1101 D +6 2 0 1100 C +3 1.4 0 1011 B 0 1010 A -3 0.708 0 1001 9 -6 0.5 0 1000 8 -9 0.355 0 0111 7 -12 0.251 0 0110 6 -15 0.178 0 0101 5 -20 -18 -16 0.126 0 0100 4 -23 -21 -19 0.089 0 0011 3 -24 0.063 0 0010 2 -27 0.045 0 0001 1 -30 0.032 0 0000 0 -33 0.022 +7 -1 Typ AV. scalar gain +9 0 Max +11 +1 Typ 2.8 1 1. Target specification. Further testing will determine final min/max limits for GAIN values of E, B, 5 and 4. 30/44 M41T00AUD 7.1 Audio section operation Gain The programmable gain stage follows the band pass filter. It provides between –33 and +12dB of gain, in 3dB steps (+/-1dB per step). The gain is selected by the GAIN bits, D3-D0 of register 08h, as listed in Table 4. A MUTE bit, D4 of the same register, allows the audio to be cut off altogether. At the first power up, GAIN will be initialized to its lowest value, 0, corresponding to a gain of –33dB. Furthermore, MUTE will be set thus cutting off all audio. On subsequent power ups, GAIN is unaffected, but the MUTE bit is always set to turn off the audio at power up. The final section is the output driver. It has a differential output capable of driving 300mW into an 8Ω load. The overall gain of the M41T00AUD is defined as the ratio of the AC output voltage, AOUT, and the AC input voltage, SIN, as shown in Figure 16. The 0.1uF input coupling capacitor blocks any DC in the input signal. Overall gain = AOUT / SIN Equation 1 AOUT is measured between the output pins AOUT+ and AOUT–. AOUT = AOUT+ - AOUT– Each of the output levels is determined by the ratio of the feedback and input resistors along with the GAIN value. AOUT+ = SIN x AV x R2/R1 AOUT– = -SIN x AV x R2/R1 where AV is the scalar gain as shown in Table 7. Substituting these into Equation 1 above yields: AOUT = SIN x AV x R2/R1 - (-SIN x AV x R2/R1) = 2 SIN x AV x R2/R1 With R1 = 2*R2, this reduces to AOUT = SIN x AV. Thus, when R1 = 2*R2, the gain levels in Table 7 reflect overall gain of the circuit (at mid-band frequencies, about 1kHz with the indicated 0.1uF capacitor). For GAIN set to B (0dB, AV = 1), the output voltage will be equal to the input (±1dB). 7.1.1 Gain tolerance Two tolerance parameters apply to the gain levels. As shown in Table 7, upper and lower limits are listed for four of the GAIN values (4, 5, Bh and Eh). For GAIN=Bh, the tolerance is ±1dB. This means the end-to-end gain of the part, with R1 = 2*R2, will be 0±1dB. For GAIN=4, 5 and Eh, the tolerance is ±2dB. At each of these three settings, as shown in table 7, the gain will be within 2dB of the listed typical value. For GAIN =E, the end-to-end gain will be between +7 and +11 dB (9±2dB). 31/44 Audio section operation M41T00AUD The other parameter pertains to the gain step size, a relative measurement. It is shown in Table 16 as 3±1dB. For any gain setting in Table 7, the next higher (or lower) setting is guaranteed to be between 2 and 4 dB higher (or lower). For example, even though no upper and lower limits are shown for GAIN = Ch, it is tested to be at 3±1dB of the case when GAIN=Bh, one step below. If GAIN=Bh tests to -0.5dB, then GAIN=Ch is tested to have an end-to-end gain of 2.5±1dB. If GAIN=Bh tests to +0.5dB, then GAIN=Ch is tested to be 3.5±1dB. This applies to all steps except the lowest one (from GAIN=0 to GAIN=1) which is not tested. In summary, for GAIN=1 to GAIN=Fh, all steps are tested to have a 1dB step size tolerance of the listed 3dB step size. The unity gain setting, Bh, will have an end-to-end gain of 0±1dB while the three levels for GAIN=4, 5 and Eh are tested to be within ±2dB of the typical gain values listed in Table 7. 7.2 Wake-up time: TWU When the device powers on, the bypass capacitor CBIAS will not be charged immediately. As CBIAS is directly linked to the bias of the amplifier, the amplifier will not work properly until the capacitor is charged. The time to reach this voltage is called the wake-up time or TWU and is specified in the electrical characteristics, table 15, for CBIAS = 1μF. 32/44 M41T00AUD 8 Initial conditions Initial conditions The first time the M41T00AUD is powered up, some of its registers will automatically have their bits set to pre-determined levels as depicted in the Table 5. Typically, these values are set to benign levels to ensure predictable operation of the device. ST, the stop bit, is a 0 at first power up thus enabling the oscillator to run without need of user intervention. On subsequent power ups, it is not altered by the device and remains at the last value programmed by the user. All other bits listed as unchanged (UC) in the table behave similarly during power cycles. The HT or halt bit is always set to 1 thus halting updates of the transfer buffer registers. The user must write it to 0 to allow updates to resume. The discrete output function available on the IRQ/FT/OUT pin is set to 1. This is an open drain output, and thus a 1 represents a high impedance condition. FT or frequency test is always disabled on power ups. The OF or oscillator fail bit will always be 1 on the first power up since the oscillator is always off prior to the first application of VCC. The trickle charger is always turned completely off after any power up. The bits affecting it are set to levels which keep all the trickle charge switches open. Both TCH2 and TCFE are 0 which opens their corresponding switches. TCHE3:TCHE0 are set to Ah, which is the exact opposite of the value (5) required to close the corresponding switch. On first power up, the tone selects bits, /256/512 and TONE, are set to select the 512 hertz tone, but have the function disabled (see Section 7). On subsequent power ups, the /256/512 select bit remains unchanged, but TONE is always cleared. Furthermore, the MUTE bit is always set to MUTE on all power ups, disabling all audio. The four-bit audio gain value is always set to the lowest setting (0) on initial power up, but remains unaffected by subsequent power cycles. The 5-bit calibration register and its associated sign bit are set to 0 on initial power up thus resulting in no correction applied to the timekeeping operation. On subsequent power ups, the contents are not altered. Table 8. Initial values Condition ST Initial power-up(1) 0 On Subsequent power-up (with UC(2) battery back-up) HT OUT FT OF OFIE TCHE /256/ TCH2 TCFE TONE MUTE GAIN 3:0 512 1 1 0 1 0 Off Ah Off 0 Off 0 Off 1 512 0 Off 1 0 MUTE -33dB 1 UC 0 UC UC Ah Off 0 Off 0 Off UC 0 Off 1 MUTE UC Calibration 0 UC 1. State of other control bits undefined 2. UC = unchanged 33/44 Maximum ratings 9 M41T00AUD Maximum ratings Stressing the device above the rating listed in the "Absolute maximum ratings" table may cause permanent damage to the device. These are stress ratings only and operation of the device at these or any other conditions above those indicated in the operating sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Refer also to the STMicroelectronics SURE Program and other relevant quality documents Table 9. Absolute maximum ratings Symbol TSTG TJ RTHJA VCC TSLD(1) Parameter Value Unit –55 to 150 °C Maximum junction temperature 150 °C Thermal resistance junction to ambient 200 °C/W –0.3 to 4.5 V 260 °C –0.3 to Vcc+0.3 V Storage temperature (VCC off, oscillator off) Supply voltage Lead solder temperature for 10 seconds VIO Input or output voltages IOA Audio output current 300 mA IOD Digital output current 20 mA PD Power dissipation Internally limited 1. Reflow at peak temperature of 255°C to 260°C for < 30 seconds (total thermal budget not to exceed 180°C for between 90 to 150 seconds). Caution: 34/44 Negative undershoots below -0.3V are not allowed on any pin while in the back-up mode. M41T00AUD 10 DC and AC parameters DC and AC parameters This section summarizes the operating and measurement conditions, as well as the DC and AC characteristics of the device. The parameters in the following DC and AC Characteristic tables are derived from tests performed under the measurement conditions listed in the relevant tables. Designers should check that the operating conditions in their projects match the measurement conditions when using the quoted parameters. Table 10. Operating and AC measurement conditions(1) Parameter M41T00AUD Supply voltage (VCC) 3.0 to 3.6V Ambient operating temperature (TA) 0 to 70°C Digital load capacitance (CL) 100pF Audio load resistance (RL) ≥ 8Ω Digital input Rise and Fall times ≤ 5ns Digital input pulse voltages 0.2VCC to 0.8VCC Digital input and output timing reference voltages 0.3VCC to 0.7VCC 1. Output Hi-Z is defined as the point where data is no longer driven. Figure 17. AC testing Input/Output waveform 0.8VCC 0.7VCC 0.3VCC 0.2VCC AI02568 Table 11. Input/output characteristics (25°C, f = 1MHz) Parameter (1) Symbol CIND Min Input capacitance, digital inputs COUTD(2) Output capacitance, digital outputs tLP I2C low-pass filter input time constant (SDA and SCL) Max Unit 7 pF 10 pF 50 ns 1. Effective capacitance measured with power supply at 3.3V; sampled only, not 100% tested 2. Outputs deselected 35/44 DC and AC parameters Table 12. Symbol M41T00AUD DC characteristics Test condition(1) Parameter ILI Input leakage current ILO Output leakage current ICC1 Active supply current Min Max Unit 0V ≤ VIN ≤ VCC, SCL pin ±1 µA 0V ≤ VOUT ≤ VCC, OUT and SDA pins ±1 µA 6.6 14.7 mA 6.4 14.3 mA No audio (AIN = VBIAS), I2C bus active at 400kHz Typ No audio (AIN = VBIAS), ICC2 Standby supply current I2C bus not active, SCL = 0Hz All inputs ≥ VCC – 0.2V or ≤ VSS + 0.2V VIL Input Low voltage –0.3 0.3VCC V VIH Input High voltage 0.7VCC VCC + 0.3 V VOL Output Low voltage IOL = 3.0mA 0.4 V Output Low Voltage (open drain)(2) IOL = 3.0mA 0.4 V IRQ/FT/OUT, SDA, SCL Vcc V VCC V 1 µA Pull-up supply voltage (open drain) VBACK(3) IBACK RTC back-up supply voltage RTC backup supply current 1.7 TA = 25°C, VCC = 0V oscillator ON, VBACK = 3V 0.6 1. Valid for ambient operating temperature: TA = 0 to 70°C; VCC = 3.0 to 3.6V (except where otherwise noted). 2. For open drain pins IRQ/FT/OUT and SDA 3. STMicroelectronics recommends the RAYOVAC BR1225 or BR1632 (or equivalent) when a battery is used. Table 13. Crystal electrical characteristics Parameter (1)(2) Symbol fO Resonant frequency RS Series resistance CL Load capacitance Min Typ Max 32.768 kHz 40 12.5 Units KΩ pF 1. Externally supplied if using the SO8 package. STMicroelectronics recommends the KDS DT-38: 1TA/1TC252E127, Tuning Fork Type (thru-hole) or the DMX-26S: 1TJS125FH2A212, (SMD) quartz crystal for industrial temperature operations. KDS can be contacted at http://xxx.kds.info/index_en.htm for further information on this crystal type. 2. Load capacitors are integrated within the M41T00AUD. Circuit board layout considerations for the 32.768kHz crystal of minimum trace lengths and isolation from RF generating signals should be taken into account. 36/44 M41T00AUD DC and AC parameters Figure 18. Power down/up mode AC waveforms VCC VSO tPD tREC SDA SCL DON'T CARE AI00596 Table 14. RTC power down/up AC characteristics Parameter(1)(2) Symbol Min Typ Max Unit tPD SCL and SDA at VIH before power down 0 ns trec SCL and SDA at VIH after power up 10 µs 1. Valid for ambient operating temperature: TA = 0 to 70°C; VCC = 3.0 to 3.6V (except where otherwise noted). 2. VCC fall time should not exceed 5mV/µs. Table 15. RTC power down/up trip points DC characteristics Parameter(1)(2) Symbol VPFD Power-fail deselect Hysteresis VSO Back-up switchover voltage (VCC < VBACK; VCC < VPFD) Hysteresis Min Typ Max Unit 2.60 2.8 2.95 V 10 mV 2.0 < VBACK < VPFD VBACK V VBACK > VPFD VPFD V 10 mV 1. All voltages referenced to VSS. 2. Valid for ambient operating temperature: TA = 0 to 70°C; VCC = 3.0 to 3.6V (except where otherwise noted). 37/44 DC and AC parameters Table 16. Symbol VOO PO-MAX PSRR TWU M41T00AUD Audio section electrical characteristics, valid for VCC = 3.3V and TAMB = 25°C (except where otherwise noted)(1) Parameter Condition Typ Max Unit 10 100 mV Output offset voltage No input signal, RL = 8Ω Maximum output power THD = 2% Max, f = 1kHz, RL = 8Ω 300 375 mW Power supply rejection ratio RL = 8Ω, Av = 2, VRIPPLE = 200mVPP audio input grounded f = 217Hz 55 61 dB Gain step size GAIN steps 1-2 to E-F (1) 2 3 Wake-up time after power up CBIAS = 1µF 1. The lowest step, from GAIN = 0 to GAIN = 1, is not tested. 38/44 Min 4 dB 150 ms M41T00AUD 11 Package mechanical data Package mechanical data In order to meet environmental requirements, ST offers these devices in ECOPACK® packages. These packages have a lead-free second level interconnect. The category of second level interconnect is marked on the package and on the inner box label, in compliance with JEDEC Standard JESD97. The maximum ratings related to soldering conditions are also marked on the inner box label. ECOPACK is an ST trademark. ECOPACK specifications are available at: www.st.com 39/44 Package mechanical data M41T00AUD A Figure 19. DFN16 (5mm x 4mm) package outline SEATING PLANE -C- A3 A1 SIDE VIEW D D2 PIN 1 E L E2 e b e BTM VIEW DFN16_ME 1. Drawing is not to scale. 40/44 M41T00AUD Package mechanical data Table 17. DFN16 (5mm x 4mm) package mechanical data mm inches Sym Min Typ Max Min Typ Max A 0.80 0.90 1.00 0.032 0.035 0.040 A1 0.00 0.02 0.05 0.00 0.0007 0.002 A3 b 0.20 0.20 0.25 0.008 0.30 0.008 0.010 D 5.00 0.197 E 4.00 0.157 0.012 D2 4.20 4.35 4.45 0.165 0.171 0.175 E2 2.30 2.45 2.55 0.091 0.096 0.100 e 0.50 L 0.30 K 0.20 0.40 0.020 0.50 0.012 0.016 0.020 0.008 41/44 Part numbering 12 M41T00AUD Part numbering Table 18. Ordering information scheme Example: Device type M41T00AUD Package D = Lead-free 5mm x 4mm DFN Temperature range 1 = 0°C to 70°C Shipping method E = ECOPACK® lead-free ICs in tube F = ECOPACK® lead-free ICs in tape & reel 42/44 M41T00AUD D 1 F M41T00AUD 13 Revision history Revision history Table 19. Document revision history Date Revision Changes 01-May-2007 1 Initial release. 13-Dec-2007 2 Minor text changes; updated footnote 1 in Table 13. 43/44 M41T00AUD Please Read Carefully: Information in this document is provided solely in connection with ST products. STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, modifications or improvements, to this document, and the products and services described herein at any time, without notice. All ST products are sold pursuant to ST’s terms and conditions of sale. Purchasers are solely responsible for the choice, selection and use of the ST products and services described herein, and ST assumes no liability whatsoever relating to the choice, selection or use of the ST products and services described herein. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted under this document. If any part of this document refers to any third party products or services it shall not be deemed a license grant by ST for the use of such third party products or services, or any intellectual property contained therein or considered as a warranty covering the use in any manner whatsoever of such third party products or services or any intellectual property contained therein. UNLESS OTHERWISE SET FORTH IN ST’S TERMS AND CONDITIONS OF SALE ST DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY WITH RESPECT TO THE USE AND/OR SALE OF ST PRODUCTS INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION), OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. UNLESS EXPRESSLY APPROVED IN WRITING BY AN AUTHORIZED ST REPRESENTATIVE, ST PRODUCTS ARE NOT RECOMMENDED, AUTHORIZED OR WARRANTED FOR USE IN MILITARY, AIR CRAFT, SPACE, LIFE SAVING, OR LIFE SUSTAINING APPLICATIONS, NOR IN PRODUCTS OR SYSTEMS WHERE FAILURE OR MALFUNCTION MAY RESULT IN PERSONAL INJURY, DEATH, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE. ST PRODUCTS WHICH ARE NOT SPECIFIED AS "AUTOMOTIVE GRADE" MAY ONLY BE USED IN AUTOMOTIVE APPLICATIONS AT USER’S OWN RISK. Resale of ST products with provisions different from the statements and/or technical features set forth in this document shall immediately void any warranty granted by ST for the ST product or service described herein and shall not create or extend in any manner whatsoever, any liability of ST. ST and the ST logo are trademarks or registered trademarks of ST in various countries. Information in this document supersedes and replaces all information previously supplied. The ST logo is a registered trademark of STMicroelectronics. All other names are the property of their respective owners. © 2007 STMicroelectronics - All rights reserved STMicroelectronics group of companies Australia - Belgium - Brazil - Canada - China - Czech Republic - Finland - France - Germany - Hong Kong - India - Israel - Italy - Japan Malaysia - Malta - Morocco - Singapore - Spain - Sweden - Switzerland - United Kingdom - United States of America www.st.com 44/44