Freescale Semiconductor Technical Data MC33780 Rev 3.0, 5/2006 Document order number: Dual DBUS Master with Differential Drive and Frequency Spreading 33780 The 33780 is a master device for two differential DBUS buses. It contains the logic to interface the buses to a standard serial peripheral interface (SPI) port and the analog circuitry to drive data and power over the bus as well as receive data from the remote slave devices. DIFFERENTIAL DBUS MASTER The differential mode of the 33780 generates lower electromagnetic interference (EMI) in situations where data rates and wiring make this a problem. Frequency spreading further reduces interference by spreading the energy across many channels, reducing the energy in any single channel. Features • Two Independent DBUS I/Os • Common SPI Interface for All Operations • Open-Drain Interrupt Output with Pull-up • Maskable Interrupts for Send and Receive Data Status • Automatic Message Cyclical Redundancy Checking (CRC) Generation and Checking • Four-Stage Transmit and Receive Buffers • 8- to 16-Bit Messages with 0- to 8-Bit CRC • Independent Frequency Spreading for Each Channel • Pb-Free Packaging Designated by Suffix Code EG +5.0 V ORDERING INFORMATION Device Temperature Range (TA) Package MC33780EG/R2 -40°C to 85°C 16 SOICW +25 V MCU 33780 VCC VCC SCLK CS SCLK MOSI MISO RST INT CLK MOSI MISO GND EG (Pb-FREE SUFFIX) 98ASB42567B 16-TERMINAL SOICW VSUP CS D0H D0L RST INT CLK D1H D1L GND Twisted Pair DSI/DBUS SLAVE 33793 DSI/DBUS SLAVE 33793 4.7 nF capacitors from D0H, D0L, D1H and D1L to circuit ground are required for proper operation. Figure 1. 33780 Simplified Application Diagram * This document contains certain information on a new product. Specifications and information herein are subject to change without notice. © Freescale Semiconductor, Inc., 2006. All rights reserved. INTERNAL BLOCK DIAGRAM INTERNAL BLOCK DIAGRAM VCC VSUP CLK Protocol Engine DSIF DSIS Spreader DSIR DSIF DSIS DSIR SCLK MISO MOSI CS SPI, Registers and Interrupt Generator DBUS Driver/Receiver DBUS Driver/Receiver D0H D0L D1H D1L TLIM INT GND GND GND RST Figure 2. 33780 Internal Block Diagram 33780 2 Analog Integrated Circuit Device Data Freescale Semiconductor TERMINAL CONNECTIONS TERMINAL CONNECTIONS RST 1 16 GND CS 2 15 D0L INT 3 14 D0H MOSI 4 13 VSUP SCLK 5 12 D1H MISO 6 11 D1L CLK 7 10 GND GND 8 9 VCC Figure 3. 33780 Terminal Connections Table 1. 33780 Terminal Definitions A functional description of each terminal can be found in the Functional Terminal Descriptions section beginning on page 13. Terminal Terminal Name Terminal Function Formal Name 1 RST Reset IC Reset 2 CS Input SPI Chip Select Input When this signal is high, SPI signals are ignored. Asserting this terminal low starts an SPI transaction. The SPI transaction is signaled as completed when this signal returns high. 3 INT Output Interrupt Output This output will be asserted low when an enabled interrupt condition occurs. It contains a pullup current source that will perform a pullup when unasserted. 4 MOSI Input Master Out Slave In SPI data into this IC. This data input is sampled on the positive edge of SCLK. 5 SCLK Input Serial Data Clock Clocks in/out the data to/from the SPI. MISO data changes on the negative transition of the SCLK. MOSI is sampled on the positive edge of the SCLK. 6 MISO Output Master In Slave Out SPI data sent to the MCU by this device. This data output changes on the negative edge of SCLK. When CS is high, this terminal is high impedance. 7 CLK Input Clock Input 8 GND Ground Ground 9 VCC Input Logic Supply 10 GND Ground Power Ground Bus 1 power return. 11 D1L Output Driver Low-Side Bus 1 Bus 1 low side. 12 D1H Output Driver High-Side Bus 1 Bus 1 high side. 13 VSUP Output Positive Supply for Bus Output 14 D0H Output Driver High-Side Bus 0 Bus 0 high side. 15 D0L Output Driver Low-Side Bus 0 Bus 0 low side. 16 GND Ground Power Ground Bus 0 power return. Definition A low level on this terminal returns all registers to a known state as indicated in the section entitled Register and Bit Descriptions. 4.0 MHz clock input. Ground reference for analog and digital circuits. Logic power source input. This supply input is used to provide the positive level output of the bus. 33780 Analog Integrated Circuit Device Data Freescale Semiconductor 3 MAXIMUM RATINGS MAXIMUM RATINGS Table 2. Maximum Ratings All voltages are with respect to ground unless otherwise noted. Exceeding these ratings may cause a malfunction or permanent damage to the device. Ratings Symbol Value VSUP -0.3 to 26.5 Unit ELECTRICAL RATINGS Supply Voltages VSUP Load Dump VSUP (300 ms maximum) V VSUPLD 40 VCC -0.3 to 7.0 – -0.3 to VCC + 0.3 V Maximum Voltage on DBUS Terminals VDBUS -0.3 to VSUP + 0.3 V Maximum DBUS Terminal Current IDBUS 400 mA Maximum Logic Terminal Current ILOGIC 20 mA VESD ±2000 VCC Maximum Voltage on Logic Input/Output Terminals ESD Voltage (1) Human Body Model (HBM) V Machine Model (MM) ±200 Charge Device Model (CDM) ±750 for corner pins ±500 for others THERMAL RATINGS Storage Temperature Tstg -55 to 150 °C Operating Ambient Temperature TA -40 to 85 °C Operating Junction Temperature TJ -40 to 150 °C Thermal Shutdown TSD 155 to 190 °C Resistance, Junction-to-Ambient RθJA 109 °C/W Resistance, Junction-to-Board RθJB 50 °C/W Soldering Reflow Temperature TSOLDER 260 °C Notes 1. ESD1 testing is performed in accordance with the Human Body Model (HBM) (CZAP = 100 pF, RZAP = 1500 Ω); ESD2 testing is performed in accordance with the Machine Model (MM) (CZAP = 200 pF, RZAP = 0 Ω); and Charge Body Model (CBM). 33780 4 Analog Integrated Circuit Device Data Freescale Semiconductor STATIC ELECTRICAL CHARACTERISTICS STATIC ELECTRICAL CHARACTERISTICS Table 3. Static Electrical Characteristics Characteristics noted under conditions 4.75 V ≤ VCC ≤ 5.25 V, 9.0 V ≤ VSUP ≤ 25 V,-40°C ≤ TA ≤ 85°C unless otherwise noted. Voltages relative to GND unless otherwise noted. Typical values noted reflect the approximate parameter means at TA = 25°C under nominal conditions unless otherwise noted. Characteristic Symbol Min Typ Max Idle, HiZ – 6.5 10 Signal High, Signal Low – 15 23 – 4.5 6.0 Unit POWER INPUT REQUIREMENTS (VSUP, VCC) IVSUP Supply Current (| IBUS | ≤ 10 µA) (Test Mode, CLK = 4.0 MHz) IVCC Supply Current (Test Mode, CLK = 4.0 MHz) IVSUP mA IVCC Signal High, Signal Low mA MICROCONTROLLER INTERFACE (RST, CS, MOSI, SCLK, AND CLK) I/O Logic Levels (RST, CS, MOSI, SCLK, and CLK) Input High VIH 0.7 – – VCC Input Low VIL – – 0.3 VCC VHYST – 500 – mV – 10 20 0 – 0.8 VCC - 0.8 – VCC MISO Terminal = 0 V -10 – 10 MISO Terminal = VCC -10 – 10 -100 -75 -50 -20 -10 -5.0 4.0 7.0 10 5.0 10 20 VSUP - 2.5 – – 4.175 4.5 4.825 1.175 1.5 1.825 Input Hysteresis (2) Input Capacitance (2) CI RST, CS, MOSI, SCLK, and CLK Output Low Voltage pF VOL MISO and INT Terminals = 0.3 mA Output High Voltage V VOH MISO Terminal = -0.3 mA Output Leakage Current V µA IMISO INT Pullup Current µA IINTPU VOUT = VCC - 1.0 V SCLK, CS Pullup Current µA IPU VOUT = VCC - 1.0 V RST Pulldown Current µA IRSTPD VOUT = 1.0 V CLK, MOSI Pulldown Current µA IPD VOUT = 1.0 V BUS TRANSMITTER (D0H, D0L, D1H, D1L) VDnD(IDLE) (4) Output Bus Idle Voltage (Differential) InH = -200 mA, InL = 200 mA (3) VDnD(HIGH) (4) Output Signal High Voltage (Differential) -12.5 mA ≤ InH ≤ 1.0 mA, -1.0 mA ≤ InL ≤ 12.5 mA (3) V VDnD(LOW) (4) Output Signal Low Voltage (Differential) -12.5 mA ≤ InH ≤ 1.0 mA, -1.0 mA ≤ InL ≤ 12.5 mA V (3) V Notes 2. Not measured in production. 3. InH = bus current at DnH, InL = bus current at DnL. 4. VDnD = VDnH - VDnL. 33780 Analog Integrated Circuit Device Data Freescale Semiconductor 5 STATIC ELECTRICAL CHARACTERISTICS Table 3. Static Electrical Characteristics (continued) Characteristics noted under conditions 4.75 V ≤ VCC ≤ 5.25 V, 9.0 V ≤ VSUP ≤ 25 V,-40°C ≤ TA ≤ 85°C unless otherwise noted. Voltages relative to GND unless otherwise noted. Typical values noted reflect the approximate parameter means at TA = 25°C under nominal conditions unless otherwise noted. Characteristic Symbol Min Typ Max Unit Vmid VSUP/2 1.0 VSUP/2 VSUP / 2 +1.0 V VCMpp – 0.3 – V Source: DnH = 0 V -400 – -200 Sink: DnH = VSUP 100 – – Source: DnL = 0 V – – -100 Sink: DnL = VSUP 200 – 400 -100 – -30 30 – 100 -100 – -30 30 – 100 DnH = 0 V -1.0 -0.18 1.0 DnH = VSUP -1.0 0.25 1.0 DnL = 0 V -1.0 -0.4 1.0 DnL = VSUP -1.0 0.08 1.0 5.0 6.0 7.0 Vmid, (DnH + DnL)/2 (Voltage Halfway Between Bus High Side and Bus Low Side) VCM Peak-to-Peak, Vmid (Signal High) - Vmid (Signal Low) (5) Output High-Side (DnH) Idle Driver Current Limit (DnL open) Output Low-Side (DnL) Idle Driver Current Limit (DnH open) Output High-Side (DnH) Signal Driver Overcurrent Shutdown IICL(HIGH) IICL(LOW) Sink: Signal High, Signal Low Sink: Signal High, Signal Low Disabled Low-Side (DnL) Bus Leakage (DnH open) mA ISCL(LOW) Source: Signal High, Signal Low Disabled High-Side (DnH) Bus Leakage (DnL open) mA ISCL(HIGH) Source: Signal High, Signal Low Output Low-Side (DnL) Signal Driver Overcurrent Shutdown mA mA ILK(HIGH) mA ILK(LOW) mA BUS RECEIVER (D0H, D0L, D1H, D1L) Comparator Trip Point COMP(TRIP) mA Notes 5. Not measured in production. 33780 6 Analog Integrated Circuit Device Data Freescale Semiconductor DYNAMIC ELECTRICAL CHARACTERISTICS DYNAMIC ELECTRICAL CHARACTERISTICS Table 4. Dynamic Electrical Characteristics Characteristics noted under conditions 4.75 V ≤ VCC ≤ 5.25 V, 9.0 V ≤ VSUP ≤ 25 V, -40°C ≤ TA ≤ 85°C unless otherwise noted. Voltages relative to GND unless otherwise noted. Typical values noted reflect the approximate parameter means at TA = 25°C under nominal conditions unless otherwise noted. Characteristic Symbol Min Typ Max tCLKHI 75 – – Unit CLOCK CLK Periods Time High ns tCLKLO 75 – – tCLKPER 245 250 255 Time for Low-to-High Transition of the CLK Input Signal tCLKLH – – 50 Time for High-to-Low Transition of the CLK Input Signal tCLKHL – – 50 tRSTLO 100 – – ns SPI Clock Cycle Time tCYC 200 – – ns SPI Clock High Time tHI 80 – – ns SPI Clock Low Time tLO 80 – – ns SPI CS Lead Time (7) tLEAD 100 – – ns SPI CS Lag Time (7) tLAG 100 – – ns tHI 80 – – ns tCSHI 80 – – ns 25 – – Time Low Period (System requirement) (6) CLK Transition (System requirement) (6) Reset Low Time ns SPI INTERFACE TIMING SPI SCLK Time Between Bytes (6) SPI CS Time Between Bursts (6) Data Setup Time tSU MOSI Valid Before SCLK Rising Edge (7) ns Data Hold Time ns MOSI Valid After SCLK Rising Edge (7) tH 25 – – MISO Valid After SCLK Falling Edge (6) tHO 0 – – – – 50 – – 100 – – 25 – – 25 Data Valid Time tV SCLK Falling Edge to MISO Valid, C = 100 pF Output Disable Time tDIS CS Rise to MISO Hi-Z Rise Time (30% VCC to 70% VCC) (6) SCLK, MISO ns tR SCLK, MISO Fall Time (70% VCC to 30% VCC) (6) ns ns tF ns Notes 6. Not measured in production. 7. SPI signal timing from the production test equipment is programmed to ensure compliance. 33780 Analog Integrated Circuit Device Data Freescale Semiconductor 7 DYNAMIC ELECTRICAL CHARACTERISTICS Table 4. Dynamic Electrical Characteristics (continued) Characteristics noted under conditions 4.75 V ≤ VCC ≤ 5.25 V, 9.0 V ≤ VSUP ≤ 25 V, -40°C ≤ TA ≤ 85°C unless otherwise noted. Voltages relative to GND unless otherwise noted. Typical values noted reflect the approximate parameter means at TA = 25°C under nominal conditions unless otherwise noted. Characteristic Symbol Min Typ Max Unit tSLEW(IDLE) 2.0 4.5 8.0 V/µs tSLEW(SIGNAL) 3.0 4.5 8.0 V/µs DRATE – – 150 kbps tBIT 6.67 – – µs INT Turn ON Delay, DBUS Transaction End to Receive FIFO INT Low (9), (13) tINTON – – 1/3 * tBIT +0.2 µs INT Turn ON Delay (C = 100 pF) (10) tINTON – – 0.2 tINTOFF – – 0.2 Spread Spectrum Mode Disabled tDBUSSTART1 1/3 * tBIT – 2/3 * tBIT Spread Spectrum Mode Enabled tDBUSSTART2 1/3 * tBIT – 4/3 * tBIT DSIF (CS) = 0.5 * VCC to DnD Fall = 5.5 V tDVLD1 – 6.0 6.56 BUS TRANSMITTER Idle-to-Signal and Signal-to-Idle Slew Rate (12 ≤ VSUP ≤ 25 V) (8) Signal High-to-Low and Signal Low-to-High Slew Rate (See Data Valid DSIS to DnD Timing) (8), (11) Communication Data Rate Capability (11) (Ensured by Transmitter Data Valid and Receiver Delay Measurements) Signal Bit Time (1 / DRATE) (11) CS to INT Low INT Turn OFF Delay, CS/SCLK Rising Edge to INT High µs DBUS Start Delay, CS/SCLK Rising Edge to DBUS (9), (11), (13) µs Data Valid (8), (10) µs DSIS (MOSI) = 0.5 * VCC to DnD Fall = 0.2 * ∆VDnD (12) tDVLD2 0.25 0.8 1.3 DSIS (MOSI) = 0.5 * VCC to DnD Rise = 0.8 * ∆VDnD (12) tDVLD3 0.25 0.8 1.3 DSIF (CS) = 0.5 * VCC to DnD Rise = 6.5 V tDVLD4 – 0.8 1.3 Signal Driver Overcurrent Shutdown Delay tOC 2.0 – 20 Signal Low Time for Logic Zero t0LO 33.3% Duty Cycle (14) Signal Low Time for Logic One 66.7% Duty Cycle (14) µs µs µs 2/3 * tBIT-0.8 2/3 * tBIT-0.6 2/3 * tBIT-0.4 µs t1LO 1/3 * tBIT-0.8 1/3 * tBIT-0.6 1/3 * tBIT-0.4 Notes 8. C = 7.5 nF from DnH to DnL and 4.7 nF from DnH and DnL to GND, capacitor tolerance = ±10%. 9. In the case where the SPI write to DnL (initiating a DBUS transaction start or causing an interrupt) is the last byte in the burst sequence, timing is from rising edge of CS. Otherwise, timing is from the first SCLK rising edge of the next SPI burst byte. 10. Delays are measured in test mode to determine the delay for analog signal paths. 11. Not measured in production. 12. ∆VDnD = VDnD(HIGH) - VDnD(LOW). 13. 14. Internal digital delay only. Guaranteed by design. 33780 8 Analog Integrated Circuit Device Data Freescale Semiconductor DYNAMIC ELECTRICAL CHARACTERISTICS Table 4. Dynamic Electrical Characteristics (continued) Characteristics noted under conditions 4.75 V ≤ VCC ≤ 5.25 V, 9.0 V ≤ VSUP ≤ 25 V, -40°C ≤ TA ≤ 85°C unless otherwise noted. Voltages relative to GND unless otherwise noted. Typical values noted reflect the approximate parameter means at TA = 25°C under nominal conditions unless otherwise noted. Characteristic Symbol Min Typ Max IRSP = -6.0 mA to DSIR (INT) = 0.5 * VCC tDRH 250 – 750 IRSP = -6.0 mA to DSIR (INT) = 0.5 * VCC tDRL 250 – 750 Unit BUS RECEIVER Receiver Delay Time (IRSP = 0 mA / 11 mA step) (15) ns Receiver Delay Time (IRSP = COMP(TRIP) - 2.0 mA/COMP(TRIP) + 2.0 mA step) (15) ns IRSP = COMP(TRIP) to DSIR (INT) = 0.5 * VCC tDRH 500 – 1500 IRSP = COMP(TRIP) to DSIR (INT) = 0.5 * VCC tDRL 500 – 1500 fCEN 132 – 148 DEV[1:0] = 10 tDEV10 400 – 600 DEV[1:0] = 01 @ fCEN=138.5KHz (Typ) tDEV01 800 – 1100 DEV On JFRDEVON – – ±1.0 DEV Off JFRDEVOFF – – ±1.0 SPREAD SPECTRUM Central Frequency Range Bit Period Deviation (+/-) (fCENMin ≤ fCEN ≤ fCENMax) kHz ns Frame Jitter (Max) (fCENMin ≤ fCEN ≤ fCENMax) (PLL On) µs Notes 15. Delays are measured in test mode to determine the delay for analog signal path. 33780 Analog Integrated Circuit Device Data Freescale Semiconductor 9 TIMING DIAGRAMS TIMING DIAGRAMS t CYC t CYC Logic 1 t CYC t CYC Logic 0 5.0 V DSIS 0V 5.0 V DSIF 0V tDVLD4 t DVLD1 DnD t SLEW(FRAME) VSUP 6.5 V t DVLD3 5.5 V t SLEW(SIGNAL) t DVLD2 4.5 V 3.9 V 2.1 V 1.5 V t0LO t1LO IOUT 6.0 mA 0 mA tDRH tDRL 5.0 V DSIR 0V Figure 4. DBUS Timing Characteristics 33780 10 Analog Integrated Circuit Device Data Freescale Semiconductor TIMING DIAGRAMS DnH VSUP Vmid + 2.25 V Vmid + 0.75 V Vmid Vmid - 0.75 V Vmid - 2.25 V DnL 0V Figure 5. DBUS Normal Bus Waveforms DnH VSUP Overvoltage Threshold Vmid + 2.25 V Vmid + 0.75 V Vmid (Clamped) Vmid - 0.75 V Vmid - 2.25 V DnL 0V Figure 6. DBUS Overvoltage Bus Waveforms 33780 Analog Integrated Circuit Device Data Freescale Semiconductor 11 TIMING DIAGRAMS CS VIH VIL VIL tCYC tLEAD tHI tLO VIH VIL SCLK tR tF VIH VIH VIH VIL tSU tH VIH MOSI VOL tV tA LSB LSB MSB VIL VOH MISO tLAG tDIS tHO VOH X MSB LSB VOL X = Don’t care VIH = 70% VCC, VOH = 70% VCC VIL = 30% VCC, VOL = 30% VCC Figure 7. SPI Interface Timing DBUS (DnH-DnL) tDBUSSTART tINTON tINTOFF INT CS SCLK MOSI Figure 8. INT and Bus Start Timing 33780 12 Analog Integrated Circuit Device Data Freescale Semiconductor FUNCTIONAL DESCRIPTIONS INTRODUCTION FUNCTIONAL DESCRIPTIONS INTRODUCTION The 33780 is intended to be used as a master device in a distributed system. It contains both protocol generators and physical interfaces to allow an MCU to communicate with devices on the bus using only a simple SPI interface. Two differential busses are provided. Using a loop-back wire allows operation of the bus in the presence of an open circuit. This is immediate and no interruption is caused by the open circuit. The differential outputs have reduced electromagnetic radiation and susceptibility. The equivalent bus capacitance consists of capacitors connected between the two bus wires and capacitors between the bus wires and ground. Because the voltage change on either of the bus wires to ground is only 1/2 the amount of change between the two bus wires, the capacitance to ground only conducts half as much current as it would if connected directly across the bus. The equivalent bus capacitance of a capacitor to ground from the bus wires is one half of the actual amount of the capacitor. The amount of capacitance from either bus wire to ground should be kept the same in order to achieve the lowest radiated EMI energy. The 4.7 nF capacitors required between the bus wires and ground result in an equivalent of 2.35 nF of capacitance across the bus as seen by either bus wire. Table 5 shows the voltages used for operation. Low side (LS) is the bus wire that is the most negative and high side (HS) is the bus wire that is the most positive. Figure 5 shows the bus waveforms in normal operation. Table 5. High-Side and Low-Side Typical Voltages (Voltage Relative to Ground) Low Side High Side IDLE HIGH LOW IDLE HIGH LOW 0 Vmid-2.25 (16) Vmid-0.75 (16) VSUP Vmid+2.25 (16) Vmid+0.75 (16) Notes 16. Vmid = VSUP /2. FUNCTIONAL TERMINAL DESCRIPTIONS RESET (RST) SERIAL CLOCK (SCLK) When pulled low, this will reset all internal registers to a known state as indicated in the section entitled Register and Bit Descriptions. This is the clock signal from the SPI master device. It controls the clocking of data to the device and data read from the device. CHIP SELECT (CS) MASTER IN/SLAVE OUT (MISO) This input is used to select the SPI port when pulled to ground. When high, the SPI signals are ignored. The SPI transaction is signaled as completed when this signal returns high. This is the SPI data from the device to the SPI master (the MCU). Data changes on the negative (falling) transition of the SCLK. CLOCK (CLK) INTERRUPT (INT) This output will be asserted ow when an enabled interrupt condition occurs. It contains an internal current pull-up source so that it will remain high when not active. The output is open-drain so that it can be ORed together with other opendrain outputs so that this IC or any of the others can assert an interrupt. MASTER OUT/SLAVE IN (MOSI) This is the SPI data input to the device. This data is sampled on the positive (rising) edge of SCLK. This is the main clock source for the internal logic. It must be 4.0 MHz. GROUND (GND) Ground source for both logic and DBUS return. POWER SOURCE (VCC) Logic power source. Nominal value is +5.0 V. This should be bypassed with a small capacitor to ground (0.01-0.1 µF) LOW-SIDE BUS (DnL) There are two independent LOW-SIDE outputs, D0L and D1L They comprise the low-side differential output signal of 33780 Analog Integrated Circuit Device Data Freescale Semiconductor 13 FUNCTIONAL DESCRIPTIONS FUNCTIONAL INTERNAL BLOCK DESCRIPTION the DBUS physical layer as shown in Figure 5. They also provide power to the slave modules during the DBUS idle time. The output of DnL should have a bypass capacitor of 4.7 nF to ground. HIGH-SIDE BUS (DnH) There are two independent HIGH-SIDE outputs, D0H and D1H They comprise the high-side differential output signal of the DBUS physical layer. They also provide power to the slave modules during the DBUS idle time. See Figure 5. The output of DnL should have a bypass capacitor of 4.7 nF to ground. POSITIVE SUPPLY FOR BUS OUTPUT (VSUP) This 9.0 V to 25 V power supply is used to provide power to the slave devices attached to the DBUS. During the bus idle time, the storage capacitors in the slave modules are charged up to maintain a regulated supply to the slave device. FUNCTIONAL INTERNAL BLOCK DESCRIPTION SPI and Registers DBUS Driver /Receiver Interrupt Generator Protocol Engine Figure 9. Block Illustration The 33780 is controlled by an MCU through an SPI interface. It handles the digital and physical layer portions of a DBUS master node. Two separate DBUS channels are included, each capable of interfacing to up to 15 DBUS slave devices (nodes). The physical layer uses a two-wire bus with analog wave-shaped voltage and current signals. Refer to Figure 1. Major subsystems include the following: • • • • • • SPI interface to an MCU A register pointer block Two channels of DBUS protocol state logic CRC block for each channel Control and status registers 4-level FIFOs on each transmit and receive buffer SPI AND REGISTERS This block contains the SPI interface logic and the control and response registers that are written to and read from the SPI interface. The IC is an SPI slave-type device, so MOSI (Master-OutSlave-In) is an input and MISO (Master-In-Slave-Out) is an output. CS and SCLK are also inputs. The SPI port will handle byte and multi-byte transfers. It addresses 22 registers. The 33780 combines the functions of both the 68HC55 (DSID) and the 33790 (DSIP). The 33780 uses the eight control registers defined in the DSID, and the remaining registers are needed for the additional modes of operation in the 33780. The organization of the registers is described in the section entitled Register and Bit Descriptions. INTERRUPT GENERATOR This circuit accepts unmasked interrupt inputs for data flow. It drives an open-drain output that allows the output to be OR connected with other open-drain outputs so that this IC or any of the others can assert an interrupt. An unmasked interrupt will cause the INT to pull down the output. Interrupts can be generated by two circumstances: (1) a Transmit FIFO register becoming empty, or (2) the Receive FIFO becoming not empty. Both of these events occur at the end of a DBUS transaction. Either of these two events will generate an interrupt when enabled by setting bits in the DnCTRL registers. Similarly, the interrupt signal can be cleared in two ways: (1) the Transmit FIFO becomes not empty, or (2) the Receive FIFO becomes empty. Both of these events are checked at the end of an SPI word (either with CS rising or with the rising edge of SCLK of a new data byte in an SPI burst). 33780 14 Analog Integrated Circuit Device Data Freescale Semiconductor FUNCTIONAL DESCRIPTIONS FUNCTIONAL INTERNAL BLOCK DESCRIPTION PROTOCOL ENGINE This block converts the data to be transmitted from the registers into the DBUS sequences, and converts DBUS response sequences to data in the registers. It generates the proper DBUS timing. Comp. DSIR The DBUS transmit protocol uses a return to 1 type data with a duty cycle determined by the logic state. The protocol requires Cyclical Redundancy Check (CRC) generation and validation. Idle DnH Signal Differential Signal Generation DSIS Common Mode Correction DnL Signal Idle Control DSIF Overvoltage TLIM Figure 10. Driver/Receiver Block Diagram DBUS DRIVER /RECEIVER (PHYSICAL LAYER) This block translates the transmit data to the voltage and current needed to drive the DBUS. It also detects the response current from the slave devices and translates that current into digital levels. These circuits can drive their outputs to the levels listed in Table 5. The internal signal DSIF controls the Idle to Signalling state change, and internal signal DSIS controls the signal level, high or low. DSIR is the slave device response signal to the logic. This is shown in Table 6. Table 6. Internal Signal Truth Table DSIF DSIS TLIM DSIR DnD 0 0 0 Return Data Signal Low 0 1 0 Return Data Signal High 1 0 0 0 High Impedance 1 1 0 0 Idle X X 1 0 High Impedance The DBUS driver block diagram is shown in Figure 10. The circuit uses independent drivers for the Idle and Signal states. This allows each driver to be optimized for its function. The Idle driver is active in Idle and during the transitions from Idle to Signal high and Signal high to Idle. The Signal driver is only active during actual signaling. Both drivers are disabled in HiZ. The Idle driver is required to supply a high current to recharge the Slave device storage capacitors. It is also required to drive the DBUS load capacitances and control the slew rate over a wide supply voltage range. The DnH and DnL Idle drivers are each optimized for their specific drive requirements. The Signal driver is optimized for driving the DBUS load, and has the requirement of good slew rate control and stability over a wide range of load conditions. The DnH and DnL outputs use identical Signal driver circuits. To ensure stability of the Signal driver, capacitors must be connected between each output and ground. These are the DBUS common mode capacitors. In addition, a bypass capacitor is required at VSUP. These capacitors must be located close to the IC terminals and provide a low impedance path to ground. 33780 Analog Integrated Circuit Device Data Freescale Semiconductor 15 FUNCTIONAL DESCRIPTIONS FUNCTIONAL INTERNAL BLOCK DESCRIPTION The DSIF signal controls the state of the drivers, enabling the Idle drivers or Signal drivers as is appropriate. A comparator in the Control block compares the DnL output voltage with the internal Signal high voltage to determine the transition from Idle driver to Signal driver. The overvoltage signal modifies the driver characteristics. This is described in more detail in the Load Dump Operation section. The overtemperature signal is also applied to this block. The Differential Signal Generation block converts the DSIS signal to the DBUS differential signal voltage levels. This differential signal is buffered and slew rate controlled by the Signal drivers. This block is active in all driver modes. A special requirement of the differential bus is to maintain a low common mode voltage. This is especially important during the Idle to Signal transition in order to produce a smooth changeover to the Signal driver. This is accomplished by monitoring the common mode voltage and modifying the Idle driver slew rates. This is the function of the Common Mode Correction block. An additional feature to make a smooth changeover and minimize undershoot is to reduce the slew rate as the changeover point is approached. This block is not illustrated in Figure 10. A sense resistor between the Signal driver and the DnH output detects the Slave device response current. A comparator (Comp.) generates the signal DSIR that is supplied to the logic. The comparator consists of a sense amplifier with offset (VOS), a filter capacitor and logic gate with buffers to produce the logic signal (DSIR). The sense amplifier is a ‘gm’ stage that amplifies the voltage across the sense resistor (RS) to produce an output current that charges and discharges a filter capacitor. The voltage across the filter capacitor is compared with the threshold voltage of the logic gate to produce the output signal. The voltage across the filter capacitor is clamped between VCC and ground. See Figure 11. RS IBUS DnH VOS gm IO C VTH DSIR Figure 11. Receive Filter Definitions • C = value of filter capacitor = 2.0 pF • VTH = threshold of logic gate = VCC/2 = 2.5 V • A = current gain from sense resistor to filter capacitor = IO /IBUS = 3.0 µA/mA (the amplifier saturates with an output current of ±40 µA) • IBUS[mA] = bus response current. • ITH[mA] = response current threshold = VOS/RS = 6 The filter delay time is given by: t[µs] = (C * VTH)/A(IBUS -ITH) = 1.7/(IBUS -ITH) The filter characteristic can also be expressed as the product of the overdrive current (IBUS -ITH) and the duration of the interference pulse, which must be less than 1.7 µs * mA for the interference to be filtered. 33780 16 Analog Integrated Circuit Device Data Freescale Semiconductor FUNCTIONAL DESCRIPTIONS FUNCTIONAL INTERNAL BLOCK DESCRIPTION SPREAD SPECTRUM CLK (4.0 MHz typ) OFFSET[8:0] PLL Logic PLLOFF SSUD Center Frequency DAC VCO SSEN CLK_VCOn (408 kHz typ) DEV[1:0] PRBS[1:0] Modulation DAC Spreader Logic Figure 12. Spread Spectrum Block Diagram The dominant source of radiated electromagnetic interference (EMI) from the DBUS bus is due to the regular periodic frequency of the data bits. At a steady bit rate, the time period for each bit is the same, which results in a steady fundamental frequency plus harmonics. This results in undesired signals appearing at multiples of the frequency that can be strong enough to interfere with a desired signal. A significant decrease of radiated EMI can be achieved by randomly changing the duration of each bit. This can significantly reduce the amplitude by having the signal spend a much smaller percentage of time at any specific frequency. The signal strength of the fundamental and harmonics are reduced directly by the percentage of time it spends on a specific frequency. For instance, if the bit rate is 136 kbps, there will be a harmonic at 680 kHz. If it is changed in frequency so that only 1/10 of the bits are at the 136 kbps rate, the signal energy at 680 kHz will be reduced by 90%. A circuit to do this is included in this IC and can perform the spreading of the signal independently for each channel. This is done in the Spread Spectrum (SS) Block Diagram shown in Figure 12. Spreading can be enabled by setting the SSENn bits in the DnSSCTRL registers. There are 64 possible bit durations that are equally spaced between the shortest and longest bit times. Because they are evenly spaced by a time difference and not by a frequency difference (the reciprocal of time), all frequency domain parameters of the SS block are expressed in units of time. VCO The output of the voltage-controlled oscillator (VCO) is used as the bit rate clock. Three cycles of this clock are used to create each bit of data on the DBUS. There are two voltages that control the period (1/ frequency) of the signal coming from the VCO. The voltage coming from the Center Frequency DAC (Digital-to-Analog Converter) in Figure 12 is used to keep the average period constant. The voltage coming from the Spreader DAC changes the period in random steps to spread the signal. The Phase Locked Loop (PLL)-derived changes are much slower to update the period than the ones derived from the Spreader Logic. This prevents the two “loops” from interacting with each other. PLL The PLL loop compensates for temperature drift and the variations in processing of the IC that would otherwise change the average data rate (center frequency). It does this by comparing a time reference derived from the clock signal (4.0 MHz) to the period of the VCO output. If the ratio is not correct, it will change the frequency of the VCO by changing the digital value it sends to the Center Frequency DAC. The PLL has fast and slow update rates for making these changes. It enters a fast update mode automatically anytime the OFFSET register is written to using the SPI, or following a reset. This fast acquisition mode consists of 64 VCO update cycles (1.4 ms per update cycle) that last about 90 ms. This is done to quickly adjust the center frequency after changes 33780 Analog Integrated Circuit Device Data Freescale Semiconductor 17 FUNCTIONAL DESCRIPTIONS FUNCTIONAL INTERNAL BLOCK DESCRIPTION have been made. After the fast acquisition, the PLL switches automatically to a slow acquisition mode (180.224 ms per update cycle, based on 4.0 MHz clock). SPREADER LOGIC The Spreader Logic contains a pseudo-random binary sequence (PRBS) generator and time compensation circuitry. The PRBS can generate maximal length sequences of 6, 7, 11, and 15 bits. Maximal length means there is no repeat of the sequence until 2n counts have been reached, where n is the selected length. A special feature of the Spreader Logic is that the bit periods are chosen in a way to keep the length of the frame constant, provided that the total number of bits is even. This is useful if the time between samples made by the slaves must be kept relatively constant. Without this feature, the time from sample-to-sample would vary randomly. The DEV1 and DEV0 bits in the DnSSCTRL register control whether the deviation is enabled or disabled. The Spreader Logic is synchronized to only change the value of the digital word to the Spreader DAC at the beginning of a DBUS bit. When spreading is enabled, these changes will occur once per DBUS bit-time. 33780 18 Analog Integrated Circuit Device Data Freescale Semiconductor FUNCTIONAL DEVICE OPERATION LOGIC COMMANDS AND REGISTERS FUNCTIONAL DEVICE OPERATION LOGIC COMMANDS AND REGISTERS SPI COMMUNICATIONS All SPI transactions start with a command byte and can be followed by 1 or more bytes of data. The start of an SPI transaction is signaled by CS being asserted low. The first bit sent (bit 7) of the first byte signals a read or write (write = 1) of data. The last five bits (bits 4–0) of the command set a pointer to the desired register. Bits 5 and 6 are unused. See Figure 13. As long as CS is asserted low, each additional byte sent over the SPI will be a read/write of data to the sequential next register. After address 10101 is written to, the next write will wrap around to address 00000. Bit 7 6 5 4 3 2 1 0 R/W X X ADDR4 ADDR3 ADDR2 ADDR1 ADDR0 Figure 13. SPI Communications, First Byte of Burst Transfer The receive FIFO is popped only when the SPI reads or writes the low data register (DnL). The Control and Status registers can be read without affecting the receive FIFO. The transmit FIFO is popped at the end of the DBUS transaction. Figure 14 shows an example of a write operation. This example assumes the last SPI transaction read or wrote the data from register 00011 and is now pointing at 00100 (D01STAT). During the first byte of the SPI transaction, the first MOSI bit is 1 (write) and the last five are 00000. During this command byte, MISO returns the data from register 00100 (D01STAT). During the next SPI transactions, MOSI updates the data in register 00000 with new data while reading back the old data via MISO. Although it looks like the read and write for an address are occurring at the same time, the changes caused earlier during the same burst would not be reflected by the data returned, because the D01STAT is latched at CS going low. When a short word is selected for Bus 0 (MS0 in D0CTRL is set), the D0H register is skipped in the sequence. The same is true for the D1H register when MS1 is set and SWLEN1 = 1000. C LK SCLK MOS I WWRITE R IT E COMMAND CO MM AN D TO P POINT O IN T T O 00000 00 00 0 DA T A TO DS I0 H DATA TO D0H ((00000) 00 00 0) D AT A TTO O D0L DSI 0L DATA (00001) (00 00 1) D AT A TTO OD SI 1H DATA D1H (00010) (0 00 10 ) DADATA T A TO SI1 L TO D D1L (00011) (0 00 11 ) MI SO DDATA AT A FROM FR OM D01STAT D SI 01 ST A(00100) T( 00 10 0) D ATFROM A FR O M DATA D0H (00000) D SI 0H ( 00 000 ) DATA FROM D0L DA T A FR OM D SI0(00001) L (0 00 01 ) D AT FROM A F ROD1H M DATA (00010) DS I1H ( 0 001 0) D AT FROM A FRO M DATA D1L (00011) D SI 1L (00 01 1) C SB CS Figure 14. SPI Burst Transfer Example DBUS COMMUNICATIONS The DBUS messages contain data from the DnH and DnL registers. A CRC pattern is automatically appended to each Bit n . . . . . . . . . . . . . . . .. message. The data and CRC lengths are programmed by the DnLENGTH register. Figure 15 shows the structure of the DBUS message. Bit 0 CRC n ..... CRC 0 Figure 15. DBUS Communications Message DBUS Driver/Receiver communications involve a frame (DSIF), a data signal (DSIS), and a data return (DSIR) signal. These are signals internal to the IC associated with the protocol engine. A message starts with a falling edge on the DSIF signal, which marks the start of a frame. There is a one bit-time delay before the MSB of data appears on the DSIS terminal. Data bits start with a falling edge on DSIS. The low time is 1/3 of the bit time for a 1, and 2/3 of a bit time for a 0. Data is transmitted on DSIS and received on DSIR terminals simultaneously. Receive data is the captured level on the DSIR terminal at the end of each bit time. At the end of the bit time for the last CRC bit, the DSIF terminal returns to a logic high (Idle level). A minimum delay is imposed between successive frames as determined by the DnCTRL register. 33780 Analog Integrated Circuit Device Data Freescale Semiconductor 19 FUNCTIONAL DEVICE OPERATION LOGIC COMMANDS AND REGISTERS Users initiate a message by writing (via the SPI interface from the MCU) to the low byte of the data register (DnL). When 9- to 16-bit messages are to be sent, the user writes to the DnH register first and then the DnL register before the combined 9 to 16-bit data value DnH:DnL is sent on the DBUS. The user should first check the TFNFn status flag to be sure the transmit FIFO is not full before writing a new data value to DnH and/or DnL. When the minimum inter-frame delay has been satisfied, the DSIF terminal will go low, indicating the start of a new transfer frame. DBUS Driver/Receiver communications involve a frame (DSIF), a data signal (DSIS), and a data return (DSIR) signal. These are signals internal to the IC associated with the prData is shifted out of DSIS (MSB first) and shifted into DSIR at the same time. As a message is received, it is stored bitby-bit into the next available receive FIFO location. For each data value in the receive FIFO, there is a one-bit status flag to indicate whether or not there was a CRC error while receiving the data. At the end of a DBUS transfer (and after the CRC error status is stable), the RFNEn flag is set (if it was not already) to indicate there is data in the receive FIFO to be read. DATA RATE In non-spread spectrum mode, the data rate is determined by the system clock (CLK) and the programmable clock divider. (The Clock Divider ratio n is defined in Table 10.) Data Rate = f CLK / (27 * n) In spread spectrum mode, the data rate is determined by the system clock (CLK) and the DnOFFSETL/H register programming. Note the programmable clock divider does not control the data rate in Spread Spectrum mode. Refer to Register and Bit Descriptions section for details. The following table gives the correspondence between the offset and the data rate for f CLK = 4.0 MHz. Table 7. Data Rate versus OFFSET (Spread Spectrum) OFFSET Data Rate HEX DEC kHz 00 0 121.2 3F 63 136.1 7A 122 150.1 9F 159 158.9 For other clock frequencies, the data rate can be computed using the following formula: Data Rate = (fCLK / 33) * (1 + OFFSET / 512) CRC GENERATION /CHECKING Whenever a message is sent on the DBUS, a 0- to 8-bit CRC value is computed and serially sent as the next n bits after the LSB of the data. The CRC length, polynomial, and initial seed are determined by the CRCLEN[3:0], CRCPOLY[7:0], and CRCSEED[7:0] control register fields. The message, including the CRC bits, is passed along to a remote peripheral, which computes a separate CRC value as the message data is received. If this computed CRC does not agree with the CRC value received in the message, the peripheral device considers the message invalid. Messages received include a 0- to 8-bit CRC value, which was computed in the peripheral device that is responding. As the message is received, a separate 0- to 8-bit CRC value is computed and is compared with the CRC value in the received message. If these values do not agree, the message is considered invalid and the ERn status bits in the D01STAT register are set as the receive data is transferred into the receive data buffer. When no remote peripheral responds to a message, the data pattern received will be all zeros with a CRC value of 0, which may be detected as a CRC error depending on the values of CRCLEN[3:0], CRCPOLY[7:0], and CRCSEED[7:0]. On the other hand, if a remote peripheral is attached and responds with all zeros with a CRC value of 1010, this may be detected as a non-error condition. CRC COMPUTATION The CRC algorithm uses a programmable initialization value, or seed, of CRCSEED[7:0] and a programmable polynomial of CRCPOLY[7:0]. Figure 16 is a VHDL description of the CRC algorithm for the DBUS standard 4-bit CRC with its initial value of 1010. A seed value is chosen so that a zero data value will generate a CRC value of 1010. A block diagram of the default CRC calculation is shown in Figure 17. 33780 20 Analog Integrated Circuit Device Data Freescale Semiconductor FUNCTIONAL DEVICE OPERATION LOGIC COMMANDS AND REGISTERS --------------------------------------------------------------------------- Calculates the 4-bit CRC (x^4 + 1) serially for 8 to 16 bits of data. -------------------------------------------------------------------------constant CRCPoly: std_logic_vector: = “0001”; -- x^4 +1 constant InitCrc: std_logic_vector: = “1010”; procedure SerialCalculateCRC4(CRC: input std_logic_vector;Data: in std_logic) is variable Xor1: std_logic; begin Xor1: = CRC(3) xor Data; CRC: = CRC(2 downto 0) & ‘0’; -- Shift left 1 bit if Xor1 = ‘1’ then CRC: = CRC xor CRCPoly end if; end SerialCalculateCRC4; Figure 16. CRC Algorithm C3 C2 C1 C0 T T T T 1X4 + 0X3 + 0X2 + 0X1 Input Data + +X0 = X4+1 Figure 17. Default CRC Block Diagram MESSAGE SIZE SPECIAL CASES The response to any 8- to 15-bit message is expected to be another 8- to 15-bit message and the response to any 16-bit message is expected to be another 16-bit message. This gives rise to some special cases when there is a transition from one message size to a different message size. Some messages must be long words (16 bits of data), others can be short words (8 to 15 bits of data). The following are examples where the word is a standard DSI formatted short word (8 bits of data and 4 bits of CRC). Example 1: If the previous message was a short word and the current message is a long word, the response message (which is also a short word) finishes before the current message frame and the CRC bits look like data bits in the long word format. Since the CRC validation of this short word message response is not reliable, this short word response should not be used. Example 2: If the previous message was a long word and the current message is a short word, the response message (which is also a long word) cannot finish before the current message frame. Bits three to zero of the data and the CRC bits are lost. Data bits seven to four of the 16-bit response message look like the CRC bits of an 8-bit response and almost certainly would not be correct. Because the response is incomplete and the CRC check is probably not valid, this response is not useful. The long word to short word message size transition normally only occurs after setting up the DBUS peripherals. During address setup, a message with address 0000 is sent to attempt to set the address of the next peripheral on the daisy-chained bus. Before any peripherals have been assigned an address, their bus switches are opened so the addressing message only goes to the first peripheral in line. As each peripheral gets an address, it closes its bus switch so the next address assignment command can reach the next peripheral in line on the bus. Each peripheral responds to an address assignment only once (during the next message after the command that set its address). After the last peripheral has been assigned an address, any subsequent address assignments will receive no response. When the master MCU fails to receive a response, it knows it has passed the last peripheral. At this point, short word messages may be sent. The first such message will have no meaningful response associated with it. The first message after reset is also a special case because there was no previous message, therefore there will be no meaningful response during the first message transfer. 33780 Analog Integrated Circuit Device Data Freescale Semiconductor 21 FUNCTIONAL DEVICE OPERATION LOGIC COMMANDS AND REGISTERS Channel 0 Clock Select and Divider RX FIFO Bit Clock 0 RX Buffer RX0 Data RX Buffer RX Buffer SPI & Registers RX Buffer CH0 Interrupt TX FIFO RX0 Status TX Buffer status regs TX0 Data control regs enable regs RST CRC Generate INT TX Buffer TX Buffer TX0 Status TX Buffer poly regs To DBUS CH0 Physical Layer CLK CRC Check CLK_VCO0 seed regs CH0 Enable length regs CH1 Enable SS ctrl regs SS offset regs RX Buffer CRC Check RX1 Data RX Buffer register pointer RX1 Status RX Buffer RX Buffer bit pointer CH1 TX FIFO TX1Data TX Buffer SPI XFER TX Buffer TX1 Status TX Buffer TX Buffer CLK_VCO1 CLK Channel 1 Clock Select and Divider CRC Generate MISO SCLK CS MOSI To DBUS CH1 Physical Layer RX FIFO SS Up/Dwn regs Bit Clock 1 Figure 18. Logic Block Diagram LOGIC BLOCK DIAGRAM DESCRIPTION Figure 18, Logic Block Diagram, shows a block diagram of the major logic blocks in the IC. SPI. Its operation is described in detail in the section entitled SPI Communications. REGISTERS SPI The SPI is a standard serial peripheral interface. This interface provides two-way communications between the IC and an MCU. The MCU can write to registers that control the operation of the IC and read back the conditions in the IC using the SPI. It can also write data to be sent out on the DBUS and read data that was returned on the DBUS. The register pointer and bit pointer are used to control which registers and bits are being written to and read from using the The register set consists of control, status, transmit, and receive types. They are written and read using the SPI interface and are affected by events in the IC. Detailed descriptions of their operation and use can be found throughout later sections of this data sheet. INTERRUPT The Interrupt block controls the INT output terminal. The main purpose of the Interrupt is to quickly inform the MCU when data has been received via the DBUS or when the 33780 22 Analog Integrated Circuit Device Data Freescale Semiconductor FUNCTIONAL DEVICE OPERATION LOGIC COMMANDS AND REGISTERS DBUS transmit buffer is empty. The INT output can only drive the level on the terminal low. The internal pull-up current or an external resistor to VCC is used to pull this terminal high. This is done so that other ICs can be connected to the interrupt terminal on the MCU. If the DBUS IC or any of the other ICs want to assert an interrupt to the MCU, they can do so by pulling the terminal low. This is similar to a logical OR of the outputs because this IC or any of the others can assert the interrupt to the MCU. The operation of the Interrupt is described in detail in the section titled Interrupt Generator. CH0/CH1 OUTPUTS RST CRC GENERATORS Asserting this terminal low will cause the part to reset, forcing registers to a known state. The description for these registers shows the bit values that will occur due to a reset. All bus activity will be halted and not allowed to restart, and no SPI activity will be recognized until the RST goes to a logic high level. Each channel contains a CRC generator that adds a series of bits to each of the transmitted data words sent out on the DBUS. The CRC bits are created from the data pattern and are used by the slave devices to determine if one or more of the data bits sent was in error. The detailed operation and control of this function is covered in the section entitled CRC Generation /Checking. These signals control the physical layer drivers and receive data from the physical layer receivers. The physical layer will convert the 0 V to 5.0 V low power logic signals to the higher voltage (up to 26.5 V) and drive (150 mA nominal) levels necessary for the DBUS to be used. It also converts the low current (0 mA to 11 mA typical) loading of the response signal from the slave to logic voltage levels to allow the response from the slaves to be received. These internal signals are named DSIF, DSIS, and DSIR. CLOCK SELECT AND DIVIDER There is an independent Clock Select and Divider for each channel. These circuits are controlled by register writes to the SPI and can select whether the Spread Spectrum Clock (CLK_VCOn) is used for the bit clock or the unspread clock is used. They also contain dividers that can be selected to reduce the bit rate by integer ratios in the unspread mode only. RXFIFO The RXFIFO is an automatic register set that allows up to four responses to be stored without being transferred to the MCU via the SPI. This is done so that data will not be lost even if the MCU takes time to read the response data. When the MCU reads a response from one of the DBUS registers, the earliest response to be received is the one read. In other words, the first in response will be the first out (FIFO). When the RXFIFO becomes not empty and interrupts are enabled, the MCU receives an interrupt via INT. TXFIFO The TXFIFO is an automatic register set that allows up to four transmit data packets to be stored for future transmission on the DBUS. This is done to prevent the overwrite of transmit data if the transmission of the previous data has not been completed. The oldest data in the registers is the first to be sent when the DBUS is ready to send. In other words, the first data put into the registers to be sent will be the first out when the DBUS is available (FIFO). When the TXFIFO becomes empty and interrupts are enabled, the MCU receives an interrupt via INT. CH0/CH1 ENABLE The output of these signals control whether the DBUS can drive power and signalling onto the bus. These are directly controlled by bits written to the control registers. CRC CHECK This circuit checks the CRC bits that have been added to the end of the response by the slave device. For a given pattern of received data a new CRC is generated and compared to the CRC bits received. If they do not match, a bit is set in the status register indicating a CRC error for the response. This bit is read back using the SPI during the same SPI transaction that reads the response in order to keep them associated with each other. The CRC bits are removed by the IC and not seen by the MCU when reading the data registers. Operation of the CRC Check is covered in the section entitled CRC Generation /Checking. SPI AND PROTOCOL ENGINE STATE MACHINES Although the SPI clock and the DBUS input clock both typically come from the same MCU system clock in an MCU plus 33780 system, there is no guaranteed relationship between these clocks, so the system was designed as if these clocks were asynchronous. The FIFO architecture eliminated most of the cases where these clocks need to interact, and the remaining cases were designed with extra care to prevent asynchronous problems. Figure 19 explains the notation used in the subsequent state diagrams. Entry to the IDLE state is asynchronous and all other state transitions are synchronous. The note in the upper right corner of the figure identifies which edge of which clock or signal is used to synchronize state transitions. Each arrow or arc has a condition that must be true before the transition can take place. This condition can be the value of a single signal or a more complex logic function. A slash (/) indicates the end of the condition or equation, which must be true for a transition to occur. The statement or statements after the slash are executed during the transition to the next state. These state diagrams are not a complete description of the entire MC33780, they are intended to include just enough relevant data to understand the operation of the state machines and basic functions. 33780 Analog Integrated Circuit Device Data Freescale Semiconductor 23 FUNCTIONAL DEVICE OPERATION LOGIC COMMANDS AND REGISTERS ASYNCHRONOUS RESET/ ACTION(S); STATE TRANSITIONS OCCUR ON POS EDGE OF XXX CLK IDLE STATE_1 SYNCHRONOUS CONDITIONS/ ACTION(S); Figure 19. State Diagram Notation Figure 20, describes how SPI transfers lead to transmit FIFO push operations or transfer abort actions. State transitions in this state machine are synchronous with rising edges of the SPI clock (SCLK). The initial state, SPI_IDLE, is entered asynchronously whenever internal reset becomes active or the SPI chip select (CS) input is de-asserted. Upon entry to the idle state, the SPI_WRITE signal is deactivated and the SPI bit counter is set to 7 (it will count down as bits are received). When the CS goes low (active), the first SPI transfer will be a command byte and the first bit indicates a write or read command. The SPI_WRITE signal takes on the value of this first bit, and the state machine enters the SPI_CMD_XFER state, where the remaining bits of the command byte are received. The last five bits of the command set the initial value of the register pointer. After the command byte is complete, the state machine advances to the SPI_BURST state, which remains active until CS goes high (or the MC33780 is reset). In the SPI_BURST state, new SPI characters are readfrom, or written-to-and-read-from, MC33780 registers. If the control register (or CRC polynomial, CRC seed, CRC length, or spread spectrum control) is written, an ABORT request is generated that will immediately stop any DBUS transfer that was in progress (refer to the DBUS transfer state diagram). If the DATA register low byte is written, a transmit FIFO push operation is generated (see transmit FIFO state diagram). If the DATA register low byte is accessed (read or written) and there is at least one entry in the receive FIFO, a receive FIFO pop operation is generated. When a DBUS transfer results in both an R_FIFO_PUSH and an X_FIFO_POP, the R_FIFO_PUSH is performed first to avoid the possibility of the transmit FIFO from getting ahead of the receive FIFO. STATE TRANSITIONS OCCUR ON POS EDGE OF SCLK RSTB ACTIVE or CSB INACTIVE/ SPI_WRITE = 0; SPI_BIT_PTR = 7; SPI_IDLE CSB ACTIVE/ SPI_WRITE= MOSI; SPI_CMD_XFER ~LAST_SPI_BIT/ SPI_BIT_PTR = SPI_BIT_PTR-1; LAST_SPI_BIT/ SPI_BIT_PTR = 7; INIT_REG_PTR FROM CMD BITS[4:0] LAST_SPI_BIT/ SPI_BURST ~LAST_SPI_BIT/ SPI_BIT_PTR = SPI_BIT_PTR-1; SPI_BIT_PTR = 7; REG_PTR = REG_PTR +1 (rolls over to 0 after 21); if SPI_WRITE & REG_PTR = CTRL or POLY or SEED or LENGTH or SSCTRL then ABORT; if SPI_WRITE & REG_PTR = DATA_L then X_FIFO_PUSH; if R_FIFO_NOT_EMPTY & REG_PTR = DATA_L then R_FIFO_POP; Figure 20. State Diagram of SPI Transfer 33780 24 Analog Integrated Circuit Device Data Freescale Semiconductor FUNCTIONAL DEVICE OPERATION LOGIC COMMANDS AND REGISTERS Figure 21 describes what happens during DBUS serial transfers. State transfers in this state machine are synchronous with positive edges on the scaled DBUS 1/3rd bit clock and the initial state is WAIT_FRAME_DLY. Initial entry into this state is caused by a reset, abort, or by enable becoming inactive. These conditions cause an asynchronous entry into this state. The exit to the next state, WAIT_SIG_DLY_0, needs to be synchronous. When enable is true and there is at least one valid entry in the transmit FIFO, the DBUS frame signal is driven low to start a frame. States WAIT_SIG_DLY_0 through WAIT_SIG_DLY_2 create a one DBUS bit-time delay before the start of the first data bit. After WAIT_SIG_DLY_2, the DBUS_BIT_PTR gets initialized to the total word length, as determined by the MSx, SWLENx, and CRCLENx bits. The XFER_DBUS_BIT_0 state is then entered. XFER_DBUS_BIT_0 through XFER_DBUS_BIT_2 form a loop where each pass corresponds to one DBUS bit time. During the first third of the bit the DSIxS signal is low, during the second third DSIxS is low for a zero or high for a one, during the last third of the bit time DSIxS is high. Provided this is not the end of the last CRC bit, the bit pointer is decremented and the loop is repeated. After the last CRC bit, the DBUS_R_PUSH state is entered. This state ensures that the CRC flag is stable prior to adjusting the receive (and transmit) FIFO pointers. The DBUS_X_POP state prevents an X_FIFO_POP from occurring at the same time as an R_FIFO_PUSH. After DBUS_X_POP, the state transitions back to the WAIT_FRAME_DLY state. This state ensures proper frame spacing is allowed to charge up the storage capacitors in remote nodes. Notice that the delay counter was reset at the end of the last CRC bit so the delay period can start to time out even while the DBUS_R_PUSH and DBUS_X_POP states are being processed. Figure 22 describes the operation of the transmit FIFO. This FIFO is four levels deep, including the stage which is written into by the SPI and the stage which provides the data for the current DBUS serial transfer. State transitions in this state machine occur at the trailing edges of X_FIFO_PUSH and X_FIFO_POP. When this FIFO is completely empty, the SPI can write four new values to fill the FIFO without waiting for any action on the DBUS side of the FIFO. Values are pushed into the FIFO from the SPI interface and values are popped after they have been serially sent out of the DBUS interface. When the FIFO is full, additional attempts to write new data from the SPI side are ignored (the host MCU should be sure the TFNFx status bit is set before writing more data to the FIFO). Reset, abort, or enable going to zero causes asynchronous entry to the TX_IDLE state, which corresponds to the FIFO empty condition. The push and pop pointers are cleared and X_FIFO_EMPTY is set to true. X_FIFO_PUSH causes the push pointer to be incremental, X_FIFO_EMPTY to be set to false, and the state to transition to TX_NOT_EMPTY. The push request comes from the SPI transfer state machine after a new value has been written into the FIFO. STATE TRANSISITONS OCCUR ON POS EDGE OF SCALED DBUS 1/3RD BIT CLOCK RSTB ACTIVE or ABORT or ~EN/ RESET_DELAY_CNTR; DSIF = 1, DSIS = 1; WAIT_FRAME_DLY DELAY_OVER & X_FIFO_NOT_EMPTY/ DSIF = 0; WAIT_SIG_DLY[0..2] CAUSES 1 BIT-TIME DLY TO 1ST BIT FALLING EDGE WAIT_SIG_DLY_1 WAIT_SIG_DLY_0 WAIT_SIG_DLY_2 DBUS_BIT_PTR = 8 to 15, OR 23; DSIS = 0; ~LAST_CRC_BIT/ DBUS_BIT_PTR = DBUS_BIT_PTR-1; DSIS = 0; XFER_DBUS_BIT_0 XFER_DBUS_BIT_1 DSIS = DATA; XFER_DEBUS_BIT_2 DSIS = 1; R_FIFO_PUSH = 0; X_FIFO_POP = 0; DBUS_X_POP DBUS_R_PUSH LAST_CRC-BIT/ DSIF = 1, DSIS = 1; RESET DELAY_CNR; R_FIFO_PUSH = 1 X_FIFO_POP = 1; Figure 21. State Diagram of DBUS Transfer 33780 Analog Integrated Circuit Device Data Freescale Semiconductor 25 FUNCTIONAL DEVICE OPERATION LOGIC COMMANDS AND REGISTERS STATE TRANSISTIONS OCCUR ON NEG EDGES OF X_FIFO_PUSH AND X_FIFO_POP ~EN or ABORT or RSTB ACTIVE/ X_PUSH_PTR = 0; X_POP_PTR = 0; X_FIFO_EMPTY = TRUE; TX_IDLE X_FIFO_PUSH/ X_PUSH_PTR = X_PUSH_PTR+1; X_FIFO_EMPTY = FALSE; X_FIFO_POP & X_POP_PTR = X_PUSH_PTR-1/ X_POP_PTR = X_POP_PTR+1; X_FIFO_EMPTY = TRUE; X_FIFO_POP & X_POP_PTR != X_PUSH_PTR-1/ X_POP_PTR = X_POP_PTR+1; TX_NOT_EMPTY X_FIFO_PUSH & X_PUSHPTR != X_POP_PTR-1 X_PUSH_PTR = X_PUSH_PTR+1; X_FIFO_PUSH & X_PUSH_PTR = X_POP_PTR-1/ X_PUSH_PTR = X_PUSH_PTR+1; X_FIFO_POP/ X_FIFO_POP = X_FIFO_POP+1; TX_FULL Figure 22. State Diagram of Transmit FIFO From TX_NOT_EMPTY, several things can happen. Additional values can be pushed into the FIFO if the push pointer is the same as the pop pointer minus one. This push fills the FIFO so the state advances to TX_FULL. Each time a new data value is pushed into the FIFO, the push pointer is incriminated. From TX_NOT_EMPTY, values may also be popped from the FIFO, freeing a stage for additional data. If the pop pointer is the same as the push pointer minus one, the pop removes the last value in the FIFO, so X_FIFO_EMPTY is set to true and the state changes back to TX_IDLE. Each time a value is popped, the pop pointer is incremental. When the transmit FIFO is full, no additional data can be written into the FIFO, so no new push requests will be generated. From TX_FULL, the only valid change is caused by a pop, which causes the pop pointer to increment and the state goes back to TX_NOT_EMPTY. (Of course reset, abort, or disable could cause the state to asynchronously change to the TX_IDLE state.) Figure 23 describes the operation of the receive FIFO. State transitions in this state machine occur at the trailing edges of R_FIFO_PUSH and R_FIFO_POP. The receive FIFO is four levels deep, including the stage which receives serial data from the current DBUS transfer and the stage that is accessible for SPI reads. In order to assure coherence of data and status, each FIFO stage includes an extra bit for the CRC error status for each received data word. Also for coherency, the DBUS transfer state machine imposes a delay at the end of a DBUS transfer to assure that the CRC status is stable before issuing the R_FIFO_PUSH request. The RX_IDLE state is asynchronously entered at system reset, when the enable bit goes low, or when there is an abort. During normal operation of the receive FIFO, values are pushed into the FIFO from the DBUS serial interface, causing the push pointer to increment. After the SPI has read a data word, the receive FIFO is popped, which makes the location available for additional data from the DBUS interface (it is the user's responsibility to read status and data within the same burst to assure coherence). The RX_NOT_EMPTY state is active as long as there is some data in the FIFO. The RX_FULL state is entered when enough data has been pushed into the FIFO from the DBUS interface to cause the push pointer to catch up to the pop pointer. Since it is not possible to introduce another DBUS serial character without reading (pop) the receive FIFO, it is not possible to overflow the receive FIFO. 33780 26 Analog Integrated Circuit Device Data Freescale Semiconductor FUNCTIONAL DEVICE OPERATION LOGIC COMMANDS AND REGISTERS STATE TRANSISTIONS OCCUR ON NEGATIVE EDGES OF R_FIFO_PUSH AND R_FIFO_POP ~EN or ABORT or RSTB ACTIVE/ R_PUSH_PTR = 0; R_POP_PTR = 0; R_FIFO_EMPTY = TRUE; RX_IDLE R_FIFO_PUSH/ R_PUSH_PTR = R_PUSH_PTR+1; R_FIFO_EMPTY = FALSE; R_FIFO_POP & R_POP_PTR = R_PUSH_PTR-1/ R_POP_PTR = R_POP_PTR+1; R_FIFO_EMPTY = TRUE; R_FIFO_POP & R_POP_PTR != R_PUSH_PTR-1/ R_POP_PTR = R_POP_PTR+1; RX_NOT_EMPTY R_FIFO_PUSH & R_PUSHPTR != R_POP_PTR-1/ R_PUSH_PTR = R_PUSH_PTR+1; R_FIFO_PUSH & R_PUSH_PTR = R_POP_PTR-1/ R_PUSH_PTR = R_PUSH_PTR+1; R_FIFO_POP/ R_FIFO_POP = R_FIFO_POP+1; OVERFLOW = FALSE; RX_FULL Figure 23. State Diagram of Receive FIFO REGISTER AND BIT DESCRIPTIONS The 33780 has 22 registers, shown in Table 8. The lower 8 (00000 through 00111) are compatible with the 8 registers in the 68HC55. The remaining registers (01000 through 10101) are needed for the additional modes of operation. Table 8. Register List Register Address Register Name 00000 D0H DBUS 0 upper byte 00001 D0L DBUS 0 lower byte 00010 D1H DBUS 1 upper byte 00011 D1L DBUS 1 lower byte 00100 D01STAT DBUS 0 and 1 status 00101 D0CTRL DBUS 0 control 00110 D1CTRL DBUS 1 control 00111 DEN 01000 D0POLY DBUS 0 CRC polynomial 01001 D1POLY DBUS 1CRC polynomial 01010 D0SEED DBUS 0 CRC seed 01011 D1SEED DBUS 1 CRC seed 01100 D0LENGTH DBUS 0 short word and CRC lengths 01101 D1LENGTH DBUS 1 short word and CRC lengths 01110 D0SSCTRL DBUS 0 spread spectrum control 01111 D1SSCTRL DBUS 1spread spectrum control 10000 D0OFFSETH DBUS 0 spread spectrum offset high 10001 D0OFFSETL DBUS 0 spread spectrum offset low 10010 D1OFFSETH DBUS 1 spread spectrum offset high 10011 D1OFFSETL DBUS 1 spread spectrum offset low 10100 D0SSUD DBUS 0 spread spectrum up/down counter 10101 D1SSUD DBUS 1 spread spectrum up/down counter Register Definition DBUS enable bits 33780 Analog Integrated Circuit Device Data Freescale Semiconductor 27 FUNCTIONAL DEVICE OPERATION LOGIC COMMANDS AND REGISTERS DLYn[B:A] DBUS Encode/Decode Logic MSn Rx FIFOn Tx FIFOn DnH Rx DnL Rx ERn DnH Tx DnL Tx (Write-Only) RFNEn TFNFn ERn TFEn (Read-Only) DnSTAT Register (Read-Only) MSn TIEn TFEn TIEn RIEn DLYn[B:A] RFNEn RIEn DnCTRL Register 4 Interrupt Sources (2 shown) ENn Interrupt Request TSn DEN Register Figure 24. DBUS Master Registers and Interrupt Block Diagram DnH REGISTERS The bit assignments are shown in Figure 25. When a short word of 8 bits is selected for the DBUS (MSn = 1), this register is skipped in the SPI burst sequence. When the short word length is set at other than 8 bits, this register will contain the bits above eight, starting with the ninth bit in the least significant bit position of the register. Unused bit positions are don’t care values. These are read/write registers. There are two of these registers, one for each of the buses, as shown in Figure 24. When written to, the data is the high byte of a 9- to16-bit command. When read, it is the high byte of a 9- to 16-bit return on the DBUS. Writing to this register does not begin a DBUS transaction. The low byte must be written to initiate the DBUS transaction. SPI Data Bit Bit 7 6 5 4 3 2 1 0 Read/Write Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 0 0 0 0 0 0 0 0 Reset Figure 25. DnH Data Register Bit Assignments 33780 28 Analog Integrated Circuit Device Data Freescale Semiconductor FUNCTIONAL DEVICE OPERATION LOGIC COMMANDS AND REGISTERS DnL REGISTERS low byte of a 16-bit return on the DBUS. Writing to this register initiates a DBUS transaction. The bit assignments are shown in Figure 26 . These are read/write registers. There are two of these registers, one for each of the buses. When written to, the data is the low byte of a 16-bit command. When read, it is the SPI Data Bit Bit 7 6 5 4 3 2 1 0 Read/Write Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 0 0 0 0 0 0 0 0 Reset Figure 26. DnL Data Register Bit Assignments D01STAT REGISTER will not be transferred to the register until CS is deasserted. This is done to ensure that partial updates will not occur. The bit assignments are shown in Figure 27 . This is a read-only register. This register covers the status of DBUS 0 and 1. The values are latched when CS is asserted low. Any changes of the status that these bits detect SPI Data Bit Bit 7 6 5 4 3 2 1 0 Read ER1 TFE1 TFNF1 RFNE1 ER0 TFE0 TFNF0 RFNE0 Reset 0 1 1 0 0 1 1 0 Figure 27. Channel 1 and 2 Status Register Bit Assignments ERn–CRC Error Bit for Channel n • 0 = CRC value for the data in the read buffer was correct and no overcurrent condition exists. • 1 = CRC value for the data in the read buffer was not correct (data not valid) or that an overcurrent event has occurred. CRC errors are associated with each data value in the receive FIFO, so each FIFO entry has a bit to indicate whether the data in that stage of the FIFO was received correctly. Whenever a received data value is available in the DnH and DnL registers, the associated CRC error status is available at ERn in the D01STAT register. When a new data value becomes available owing to a pop (read) of a previous value, the ERn status flag reflects the CRC status of the new data value. There is no separate interrupt associated with ERn because it is always associated with the RFNEn status flag. TFEn–Transmit FIFO Empty Bit for Channel n • 0 = Transmit FIFO not empty. • 1 = Transmit FIFO empty. When the transmit FIFO is empty, four consecutive write bursts may be used to fill the FIFO without checking the flags between writes. INT will be asserted on the transmit FIFO empty condition if TIEn is set. INT will be de-asserted when TIEn is cleared or a byte is written to DnL. TFNFn–Transmit FIFO Not Full Bit for Channel n • 0 = Transmit FIFO full; no more room for additional data. • 1 = Transmit FIFO not full; there is room for more data in the transmit FIFO. There is no interrupt associated with the transmit FIFO not full condition. When the conclusion of a transfer frame would cause both TFNF and RFNE to become set, RFNE becomes set but TFNF is not set until one clock cycle later. When the transmit FIFO is full, attempts to write more data into the FIFO are ignored. RFNEn–Receive FIFO Not Empty Bit for Channel n • 0 = No new data ready. • 1 = One or more data entries in the receive FIFO; data is available to be read. It is not possible to overflow the receive FIFO because it is not possible to get more than four transmit messages into the system at a time. When there is any data in the receive FIFO, a write to the transmit buffer also pops data from the receive FIFO. If RIEn is set, INT will be asserted if this bit is set and data becomes available in the receive buffers. 33780 Analog Integrated Circuit Device Data Freescale Semiconductor 29 FUNCTIONAL DEVICE OPERATION LOGIC COMMANDS AND REGISTERS DnCTRL REGISTER each of the buses. The bit assignments are shown in Figure 28. The read/write DnCTRL register sets up conditions to be used on the DBUS. There are two of these registers, one for SPI Data Bit Bit 7 6 5 4 3 2 1 0 Read/Write DIV1 DIV0 DLYB DLYA RIE TIE 0 MS 0 0 0 0 0 0 0 0 Reset Figure 28. Dn Control Register Bit Assignment Each output n has an associated DnCTRL register. This register should be written to before data is sent over its bus. A write to the register will abort any current activity on the bus. Any bit changes will take place on the next DBUS transaction following the conclusion of the SPI write to the register. Refer to the Protocol Engine section for more detail. DLY[B:A]–Interframe Delay for Channel n These bits specify the minimum delay between transfer frames on the bus as illustrated in Table 9. For example, when DLY[B:A] is set to 00, there is a minimum of four bit times of IDLE voltage level. The time is measured from the end of a DBUS transaction (signaled by the start of the signal high to IDLE voltage transition) to the start of a new DBUS transaction (signaled by the start of the IDLE voltage to signal high transition). Table 9. DLY[B:A] Frame Spacing • 1 = Transmit interrupt enabled. Whenever the TFE status flag is 1, the INT terminal will be low to request an interrupt. MS–Message Size for Channel n • 0 = Long Word. • 1 = Short Word The Long Word will contain 16 bits of data and 0 to 8 bits of CRC. The Short Word can be made to have between 8 and 15 bits of data and 0 to 8 bits of CRC. Long words are generally used for configuration and setup messages. Short words are generally used for DBUS data transactions. DIV[1:0]–Clock Divider The DIV bits set a pre-scaler for the bit clock to allow the bit rate to be reduced by selectable integer values. The divider values are shown in Table 10. The clock divider is used during fixed frequency operation and is ignored when in the spread-spectrum mode. DLY[B:A] Minimum Delay Between Frames (Bit Times) 00 4 01 5 DIV[1:0] N 10 6 00 1 11 8 01 2 10 4 11 8 Table 10. Clock Divider RIE–Receive Interrupt Enable Channel n • 0 = Receive interrupt disabled. RFNE status does not affect INT terminal. • 1 = Receive interrupt enabled. Whenever the RFNE status flag is 1, the INT terminal will be low to request an interrupt. TIE–Transmit Interrupt Enable Channel n • 0 = Transmit interrupt disabled. TFE status does not affect INT terminal. SPI Data Bit Read/Write Reset Bit 7 6 TS1 TS0 (Read-Only) (Read-Only) 0 0 DEN Register This read/write register is used to enable or disable each of the busses. It also allows the state of the thermal shutdowns to be read. The bit assignments are shown in Figure 29. If a thermal shutdown occurs, the output of the bus driver will be tri-stated and the receive current detector disabled. This will result in an all 0 response, which will cause a CRC error. 5 4 3 2 1 0 0 0 0 0 EN1 EN0 0 0 0 0 0 0 Figure 29. DEN Register Bits 33780 30 Analog Integrated Circuit Device Data Freescale Semiconductor FUNCTIONAL DEVICE OPERATION LOGIC COMMANDS AND REGISTERS TSn – Indicates a Thermal Shutdown on Channel n The ENn bits are cleared and the channel disabled if a thermal shutdown occurs. It is necessary to write a 1 to the ENn bit to turn it back on. • 0 = No thermal shutdown occurring on Channel n. • 1 = Thermal shutdown has occurred on Channel n. The TSn bits are latched when a thermal shutdown occurs for a minimum of 16 clock cycles. The TSn bits are cleared after a read of the DEN register if no longer in thermal shutdown. DnPOLY REGISTERS These read/write registers control the polynomial used for calculating the CRC that is transmitted/received on the DBUS channels. There are two of these registers, one for each DBUS channel. The bit assignments are shown in Figure 30. ENn – Controls Enabling and Disabling of Channel n • 0 = Channel n is disabled. • 1 = Channel n is enabled. SPI Data Bit Read/Write Reset Bit 7 6 5 4 3 2 1 0 CRCPOLY7 CRCPOLY6 CRCPOLY5 CRCPOLY4 CRCPOLY3 CRCPOLY2 CRCPOLY1 CRCPOLY0 0 0 0 1 0 0 0 1 Figure 30. Dn Polynomial Register Bit Assignments Each bit represents a polynomial term in the CRC equation. Bit 7 represents x7, bit 6 represents x6, and so on. Both the short and long word command use the same polynomial. The polynomial bits beyond what is specified in the CRCLEN[3:0] registers are ignored, and the most significant term of each polynomial is assumed to be on. So, for example, to represent a 6-bit CRC with a polynomial of x6+ x3 + 1, the value in DnPOLY is xx001001. Bits 7 and 6 are ignored in this case. These registers reset to 00010001 (x4 + 1), which is the default DSI value (bit 4 does not need to be on for this case but is included for readability). SPI Data Bit Read/Write Reset Bit 7 6 CRCSEED7 CRCEED6 0 0 A write to the register will abort any current activity on the bus. Any bit changes will take place on the next DBUS transaction following the conclusion of the SPI write to the register. DnSEED REGISTERS These read/write registers control the initial value, or seed, used for calculating the CRC that is transmitted/received on the DBUS channels. There are two of these registers, one for each DBUS channel. The bit assignments are shown in Figure 31. 5 4 3 2 1 0 CRCEED5 CRCEED4 CRCEED3 CRCEED2 CRCEED1 CRCEED0 0 0 1 0 1 0 Figure 31. Dn CRC Seed Register Bit Assignments The bits in these registers form a word that is used as the seed for the CRC calculations. Both the short and long word commands use the same seed. The seed bits beyond what is specified in the CRCLEN[3:0] registers are ignored. So, for example, to represent a 6-bit CRC with a seed 010101, the value in DnSEED is xx010101. Bits 7 and 6 are ignored in this case. These registers reset to 00001010, which is the default DBUS value. A write to the register will abort any current activity on the bus. Any bit changes will take place on the next DBUS transaction following the conclusion of the SPI write to the register. DnLENGTH REGISTERS These read/write registers control the short word lengths and CRC lengths for data that is transmitted/received on the DBUS channels. There are two of these registers, one for each DBUS channel. The bit assignments are shown in Figure 32. SPI Data Bit Bit 7 6 5 4 3 2 1 0 Read/Write SWLEN3 SWLEN2 SWLEN1 SWLEN0 CRCLEN3 CRCLEN2 CRCLEN1 CRCLEN0 1 0 0 0 0 1 0 0 Reset Figure 32. Dn Short Word and CRC Length Register Bit Assignments 33780 Analog Integrated Circuit Device Data Freescale Semiconductor 31 FUNCTIONAL DEVICE OPERATION LOGIC COMMANDS AND REGISTERS A write to the register will abort any current activity on the bus. Any bit changes will take place on the next DBUS transaction following the conclusion of the SPI write to the register. The SWLEN3 bit is not used, since words less than 8 bits are not allowed. When reading the SWLEN3, bit 0 is always return; however, the logic interprets the bit as if it were a 1. CRCLEN[3:0]–CRC Length in Bits SWLEN[3:0]–Short Word Length in Bits These bits specify the bit length of CRCs that are sent out with commands and read back in. The length is valid for both short and long word commands. The reset value for these bits is 0100 (4 bits), which is the default DSI value. Allowed CRCLEN[3:0] values range from 0 bits (no CRC) to 8 bits. If an attempt is made to write a value that is greater than 8 bits, the value 8 (1000) is automatically written into this register. The CRCLEN[3:0] value overrides the CRCPOLY and CRCSEED bit values that are beyond what the CRCLEN[3:0] specifies. These bits specify the bit length of the short word command that will be sent onto the specified DBUS channel. The reset value for these bits is 1000 (8 bits), which is the default DSI value. Allowed SWLEN[3:0] values range from 8 bits to 15 bits. If an attempt is made to write a value that is less than 8 bits, a 1 is automatically written to SWLEN3, thereby making the register value greater than or equal to 8 bits. Note If a SWLEN[3:0] value greater than 8 bits is chosen, it is necessary to write a full 8 bits into both the DnL and DnH registers with an SPI command, even though there will be some MSBs of DnH that are not sent out on the DBUS. Similarly, to read the data back onto the SPI, it is necessary to read the full DnL and DnH registers, ignoring unused DnH bits. DnSSCTRL REGISTERS These registers control the operation of the spread spectrum circuits. A write to the register will abort any current activity on the bus. Any bit changes will take place on the next DBUS transaction following the conclusion of the SPI write to this register. The bit assignments are shown in Figure 33. SPI Data Bit Bit 7 6 5 4 3 2 1 0 Read/Write 0 0 SSEN PLLOFF PRBS1 PRBS0 DEV1 DEV0 Reset 0 0 0 0 0 0 0 0 Figure 33. Dn Spread Spectrum Control Register Bit Assignments SSEN–Spread Spectrum Enable for Channel n This bit enables spread spectrum on the particular channel that is specified. With deviation enabled, the DBUS bit periods will be pseudo-randomly varied from one bit to the next, while keeping the time between successive Frame edges constant. The DBUS data rate will be controlled by a programmable PLL loop, rather than the 4.0 MHz external clock. PLLOFF–Spread Spectrum PLL Disable for Channel n This bit disables the PLL loop updating of the DBUS frequency. The PLL adjusts the spread spectrum frequency up and down by comparing it to a divided down version of the external 4.0 MHz clock. If the internal spread spectrum clock is stable, then it is useful to be able to turn off the PLL updates, thus avoiding clock jitter. In order to change the frequency of the PLL, PLLOFF must be reset. A write operation to the frequency offset registers is not allowed while PLLOFF is set. PRBS[1:0]–Pseudo-Random Binary Sequence Register Length for Channel n These bits control the length of the Pseudo-Random Binary Sequence register (PRBS). The PRBS is used to randomize the DBUS spread spectrum frequencies, and choosing different lengths will change the XOR tap position on the PRBS. The following Table 11 describes the bit encoding of this field. Table 11. PRBS Bit Encoding PRBS[1:0] PRBS Reg Length XOR Input A XOR Input B 00 6 5 4 01 7 6 5 10 11 10 8 11 15 14 13 33780 32 Analog Integrated Circuit Device Data Freescale Semiconductor FUNCTIONAL DEVICE OPERATION LOGIC COMMANDS AND REGISTERS DEV[1:0]–Spread Spectrum Frequency Deviation for Channel n The mode with deviation disabled may be used to achieve fine control of the bit rate without frequency spreading. These bits control the frequency deviation of the spread spectrum signalling. DEV [1:0] is recommended to be programmed to either 10 or 11 whenever the spread spectrum is enabled. DEV = “00” (the default) and DEV = “01” (typical 1000 nsec) are optionally available under application usage. DEV[1:0] = 10 = Deviation enabled. DEV[1:0] = 11 = Deviation disabled. DnOFFSETH and DnOFFSETL REGISTERS These read/write registers control the spread spectrum PLL offset value. There are four of these registers, two for each DBUS channel. The bit assignments are shown in Figure 34 and Figure 35. SPI Data Bit Bit 7 6 5 4 3 2 1 0 Read/Write – – – – – – – OFFSETH8 Reset 0 0 0 0 0 0 0 0 Figure 34. Dn Spread Spectrum Offset High Register Bit Assignments SPI Data Bit Read/Write Reset Bit 7 6 5 4 3 2 1 0 OFFSETL7 OFFSETL6 OFFSETL5 OFFSETL4 OFFSETL3 OFFSETL2 OFFSETL1 OFFSETL0 0 0 0 0 0 0 0 0 Figure 35. Dn Spread Spectrum Offset Low Register Bit Assignments The OFFSETH[0] and OFFSETL[7:0] register bits control the updating of the PLL loop center frequency. After reset or when either of these registers is written to, the spread spectrum PLL loop goes into fast acquisition mode for 64 cycles. After this, the PLL switches to slow acquisition mode. The default value of 0 0000 0000 sets the PLL to the minimum data rate available. SPI Data Bit DnSSUD Registers These read-only registers reflect the spread spectrum PLL loop 6-bit update count. There are two of these registers, one for each DBUS channel. The bit assignments are shown in Figure 36 and Figure 37. D0SSUD also contains an ID bit in D0SSUD[2] which is hardwired to logic 1. This bit is a 1 regardless of the state of the spread-spectrum control bits in DOSSCTRL. Bit 7 6 5 4 3 2 1 0 Read 0 0 SSUD5 SSUD4 SSUD3 ID SSUD1 SSUD0 Reset 0 0 1 0 0 1 0 0 Figure 36. D0 Spread Spectrum Up/Down Register Bit Assignments SPI Data Bit Bit 7 6 5 4 3 2 1 0 Read 0 0 SSUD5 SSUD4 SSUD3 SSUD2 SSUD1 SSUD0 Reset 0 0 1 0 0 0 0 0 Figure 37. Dn Spread Spectrum Up/Down Register Bit Assignments The SSUD[5:0] value reflects the current state of the PLL loop up/down counter. This 6-bit value is the control input to the Center Frequency DAC of Figure 12. This 6-bit value is normalized to the center frequency of the PLL.A write to the register will be ignored. The 6-bit SSUD value will be latched whenever CS transitions low so that the value of SSUD will not change during an SPI command. The default value of 10 0000 puts the VCO at the center of its range to minimize the PLL acquisition time. 33780 Analog Integrated Circuit Device Data Freescale Semiconductor 33 FUNCTIONAL DEVICE OPERATION PROTECTION AND DIAGNOSIS FEATURES PROTECTION AND DIAGNOSIS FEATURES For handling fault conditions on the DBUS, the driver includes overcurrent and thermal protection and an overvoltage operating mode. See DEN Register section for a description of the fault reporting and clearing of the EN bits. LOAD DUMP OPERATION OVERCURRENT PROTECTION Current limiters on the outputs prevent damage in the case of shorts. Running in-current limit results in high power dissipation of the IC. If the power dissipation becomes high enough, the die temperature will rise above its maximum rating and an overtemperature circuit on the IC will shut down the DBUS Driver/Receiver block. The Idle driver has current limits for protection of both this device and slave devices connected on the DBUS. The DnH driver has a high value current limit when it is sourcing current to allow the driver to charge the slave power storage capacitors, and a lower value current limit when sinking current and slewing the load capacitance. Conversely, the DnL driver has a high value current limit when it is sinking current, and a lower value current limit when it is sourcing current. The overcurrent protection for the Signal driver incorporates a gross current limit and an over current shutdown. The current shutdown is set at a low value, such that the Signal driver will shut down if the sourcing or sinking current remains at a value larger than the response current. The overcurrent shutdown is delayed by a filter to allow the load capacitors to be slewed without causing a shutdown. The purpose of the gross current limit is to protect the drivers during the filter delay time. This current limit is set higher than the peak current required to slew the load capacitance. The signals from the sourcing and sinking current detection circuits are connected to a logical OR. The combined signal passes through a common filter before setting the overcurrent latch. In overcurrent shutdown the entire Signal driver will be shut down and the DBUS will be high impedance until the end of Frame, when the DBUS returns to the Idle state. In addition, the output of the OR gate is logically OR’ed with the CRC error hit ERx which can be read in register DO1STAT (see Figure 28). The end of Frame will clear the overcurrent shutdown state, allowing the Signal driver to retry in the next Frame. THERMAL PROTECTION Independent thermal protection is provided for each DBUS. The thermal limit cell is located adjacent to the Idle and Signal drivers for each channel, such that both drivers are protected. When a thermal fault is detected, the driver is disabled (Hi-Z) until it is re-enabled via the SPI. The thermal protection incorporates hysteresis preventing the DBUS from being re-enabled until the temperature has decreased. Thermal fault information is reported via the DEN register. During an overvoltage condition (e.g., when load dump is applied at the VSUP terminal), the DBUS voltage waveform is modified to ensure that power dissipation is minimized, DBUS timing is not violated, and internal components are protected. The midpoint of the signalling voltage is clamped at about 13 V such that, for VSUP greater than 26 V, the signalling voltage levels do not increase. An overvoltage detection circuit connected to DnH, having a threshold at about 26 V, causes the slew rates and driver conditions to be modified. For a Signal-to-Idle transition, this causes the DnH voltage to rise rapidly to the Idle state and the DnL voltage is maintained close to zero. For an Idle-to-Signal transition, the DnH voltage will decrease rapidly until the overvoltage threshold is reached, when normal operation resumes. During this rapid fall of DnH, the DnL voltage is maintained close to zero by forcing that driver on. See Figure 6. RESET FUNCTION A low level on RST forces the internal registers to a known state. The receive and transmit FIFO pointers are reset and the FIFOs are cleared. Because the DBUS channels are now disabled (ENn = 0), the DBUS lines are tri-stated. ABORT FUNCTION An abort is generated whenever a control register (DnCTRL, DnPOLY, DnSEED, DnLENGTH, or DnSSCTRL) is addressed while writing, even if the data is unchanged. No other register writes cause an abort. Reads of any register do not cause an abort. The DEN register is not affected by an abort. The abort occurs as soon as the address of the control register is received on the SPI. Any DBUS transfer that was in progress is stopped, and DBUS lines return to their Idle states. The abort condition remains true throughout the SPI write to the DBUS control registers. After the last bit of the DBUS control register is written, the transmit and receive FIFO pointers are reset and FIFO data is cleared. The programmed inter-frame delay is then enforced (using the new values of the delay control bits) to allow reservoir capacitors in remote nodes to charge. In the case of DLY changing, any partial inter-frame delay based on old control settings is lost. ENABLE (DISABLE) FUNCTION When a DBUS channel is disabled, the 33780 device forces its bus output to tri-state. The transmit and receive FIFO pointers are reset and the FIFO locations are forced to zero. Any DBUS transfer that was in progress is stopped. 33780 34 Analog Integrated Circuit Device Data Freescale Semiconductor PACKAGING PACKAGE DIMENSIONS PACKAGING PACKAGE DIMENSIONS For the most current package revision, visit www.freescale.com and perform a keyword search using the “98A” listed below. 33780 Analog Integrated Circuit Device Data Freescale Semiconductor 35 REVISION HISTORY PACKAGE DIMENSIONS REVISION HISTORY Revision Date Description of Changes 1.0 3/2006 • Initial Release 2.0 4/2006 • • Changed TA temperature from -40°C to 125°C to -40°C to 85°C Changed Soldering Reflow Temperature from 250 to 260 Maximum 3.0 5/2006 • Changed DnSSUD Registers on page 33. 33780 36 Analog Integrated Circuit Device Data Freescale Semiconductor How to Reach Us: Home Page: www.freescale.com E-mail: [email protected] USA/Europe or Locations Not Listed: Freescale Semiconductor Technical Information Center, CH370 1300 N. Alma School Road Chandler, Arizona 85224 +1-800-521-6274 or +1-480-768-2130 [email protected] Europe, Middle East, and Africa: Freescale Halbleiter Deutschland GmbH Technical Information Center Schatzbogen 7 81829 Muenchen, Germany +44 1296 380 456 (English) +46 8 52200080 (English) +49 89 92103 559 (German) +33 1 69 35 48 48 (French) [email protected] Japan: Freescale Semiconductor Japan Ltd. Headquarters ARCO Tower 15F 1-8-1, Shimo-Meguro, Meguro-ku, Tokyo 153-0064 Japan 0120 191014 or +81 3 5437 9125 [email protected] Asia/Pacific: Freescale Semiconductor Hong Kong Ltd. Technical Information Center 2 Dai King Street Tai Po Industrial Estate Tai Po, N.T., Hong Kong +800 2666 8080 [email protected] For Literature Requests Only: Freescale Semiconductor Literature Distribution Center P.O. Box 5405 Denver, Colorado 80217 1-800-441-2447 or 303-675-2140 Fax: 303-675-2150 [email protected] MC33780 Rev 3.0 5/2006 Information in this document is provided solely to enable system and software implementers to use Freescale Semiconductor products. There are no express or implied copyright licenses granted hereunder to design or fabricate any integrated circuits or integrated circuits based on the information in this document. Freescale Semiconductor reserves the right to make changes without further notice to any products herein. Freescale Semiconductor makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does Freescale Semiconductor assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation consequential or incidental damages. “Typical” parameters that may be provided in Freescale Semiconductor data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals”, must be validated for each customer application by customer’s technical experts. Freescale Semiconductor does not convey any license under its patent rights nor the rights of others. Freescale Semiconductor products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or other applications intended to support or sustain life, or for any other application in which the failure of the Freescale Semiconductor product could create a situation where personal injury or death may occur. Should Buyer purchase or use Freescale Semiconductor products for any such unintended or unauthorized application, Buyer shall indemnify and hold Freescale Semiconductor and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized use, even if such claim alleges that Freescale Semiconductor was negligent regarding the design or manufacture of the part. Freescale™ and the Freescale logo are trademarks of Freescale Semiconductor, Inc. All other product or service names are the property of their respective owners. © Freescale Semiconductor, Inc., 2006. All rights reserved.