Features 2” x 4” x 1.3” Package Suitable for 1U Applications Class I and Class II versions 110W w/air, 80W convection cooled Universal Input 90-264Vac Efficiency 87% typical Approved to CSA/EN/IEC/UL60601-1, 3rd Edition 2 x MOPP Isolation Power Fail Signal Remote Sense (optional) 3 Year Warranty RoHS Compliant Description The MINT3110 Series are medical grade, high efficiency, triple output power supplies in a small 2” x 4” size. The MINT3110 family is ideal for medical applications in surgical and laboratory instruments requiring low leakage, multiple rd outputs and small footprint. Surpassing the strict requirements of IEC 60601-1 3 edition, the MINT3110 models feature outputs of 5/±12V, 5/±15V, 5/±24V, Power Fail/DC OK signal, very low earth leakage current of 200μA, Class B Conducted EMI, 2 MOPP (means of patient protection) isolation, and are available in Class I and Class II configurations. Model Selection Model Number Volts* V1 MINT3110A0508K01 MINT3110A1708K01 MINT3110A1908K01 Notes: Output Current** w/200LFM air Convection Ripple & Noise*** Total Regulation OVP Threshold 2% 7.5V max. 5V 14.0A 10.0A 1.0% pk-pk V2 12V 6.0A 4.5A 1.0% pk-pk 3% 115%-135% V3 -12V 1.0A 1.0A 2.0% pk-pk 10% 115%-135% V1 5V 14.0A 10.0A 1.0% pk-pk 2% 7.5V max. V2 15V 4.5A 3.5A 1.0% pk-pk 3% 115%-135% V3 -15V 1.0A 1.0A 2.0% pk-pk 10% 115%-135% V1 5V 12.0A 8.0A 1.0% pk-pk 2% 7.5V max. V2 24V 4.0A 3.0A 1.0% pk-pk 3% 115%-135% V3 -24V 1.0A 1.0A 2.0% pk-pk 10% 115%-135% * 5V output is adjustable with +/-10% range ** Total convection power is 80 Watts. *** Measured with noise probe directly across output terminals, and load terminated with 0.1μF ceramic and 10μF low ESR capacitors. Ripple & Noise of V2 at no load is 2% maximum. General Specifications AC Input Input Current 100-240Vac, ±10%, 47-63Hz, 1 120–370Vdc Turn On Time Less than 2 sec. @115Vac (inversely proportional to input voltage and thermistor temperature) 115Vac: 1.5A, 230Vac: 0.75A Hold-up Time 16mS typical at 110W, 120Vac input MINT3110 110W Triple Output Medical Series General Specifications (continued) Inrush Current Input Fuses Earth Leakage Current Efficiency Output Power Transient Response Signals 264Vac, cold start: will not exceed 45A Overload Protection F1, F2: 2.5A, 250Vac fuses provided on all models Short Circuit Protection <290μA@264Vac, 60Hz, NC Overvoltage Protection 87% typical at 230Vac 110W continuous with 200 lfm airflow, 80W convection cooled – See chart for specific voltage model ratings. Switching Frequency 500µS typ. for return to within 0.5% of nominal, 50% load step. i/t <0.2A/μS. Max Volt Deviation = 3% Isolation AC Power Fail, DC OK 150%-300% above rating for V2 & V3, 110%200% for V1. Hiccup Mode Provided - no damage will occur if the output is shorted. See models chart for trip range. PFC: Variable 30-400kHz. Main Converter: Variable 35-180kHz, 65-70kHz at full load. Input-Output: 4000Vac, 2 x MOPP Input-Ground: 1800Vac, 1 x MOPP Output-Ground: 500Vac Ripple and Noise See models chart Operating Temperature -10°C to +70°C Output Voltage See models chart Temperature Derating Derate output power linearly above 50°C to 50% at 70°C +/-10% from nominal on 5V output Storage Temperature -40°C to +85°C Voltage Adjustability Minimum Load Total Regulation Vibration Dimensions Weight Altitude Not required Relative Humidity See models chart Operating: 0.003g²/Hz, 1.5grms overall, 3 axes, 10 min/axis Non-Operating: 0.026g²/Hz, 5.0grms overall, 3 axes, 1 hr/axis Shock Safety Standards W: 2.0” x L: 4.0” x H: 1.3” MTBF 200g Operating: -500 to 10,000 ft. Non-operating: -500 to 40,000 ft. 5% to 95%, non-condensing Operating: Half-sine, 20gpk, 10ms, 3 axes, 6 shocks total Non-Operating: Half-sine, 40 gpk, 10 ms, 3 axes, 6 shocks total EN/CSA/UL/IEC 60601-1, 3rd Edition 245,000 hours, 25°C Ambient, 110Vac input Auxiliary Signals AC Power Fail: During normal operation, stays HIGH. Signal goes LOW with at least 6mS warning before loss of DC output from AC failure. Remote Sense: (5V output, optional) Will compensate for 0.5V drop min. Will operate without remote sense connected. Reverse connection protected. DC OK: Open collector logic signal goes and stays HIGH 100mS to 500mS after main output reaches regulation. Notes: 1. Specifications are for convection rating at factory settings at 115 Vac input, 25°C ambient unless otherwise stated. 2. For DC input an external DC safety rated fuse must be used. www.slpower.com MINT3110 REV 1.3, 12-NOV-12 2 MINT3110 110W Triple Output Medical Series Connector Information Input Connector J100 Ground J101 DC Output Connector J200 PIN 1) AC NEUTRAL PIN 2) EMPTY PIN 3) AC LINE 0.187” FASTON TAB PIN 1) +V1 PIN 2) +V1 PIN 3) GND PIN 4) GND PIN 5) GND PIN 6) GND Mating Connector: Molex 09-50-3031 Pins= 08-52-0072 Mating Connector: Molex 01-90020001 Mating Connector: JST VHR-8N Pins = SVH-21T-P1.1 Signal Connector J300 PIN 1) Power Fail/DC OK PIN 2) GND PIN 3) +Remote Sense PIN 4) –Remote Sense PIN 7) V2 PIN 8) V3 Mating Connector: Molex 51065-0400 Pins = 50212-8100 Isolation Specifications Parameter Conditions/Description Insulation Safety Rating Input/Ground Input/Output Output/Ground Electric Strength Test Voltage Input/Ground Input/Output Output/Ground Min Nom Max Units Basic (1 MOPP) Reinforced (2 MOPP) Operational 1800 4000 500 - Vac Vac Vac - Leakage Current Parameter Conditions/Description Max Earth Leakage Current Normal Condition (NC) Single Fault Condition (SFC) 290µA 420µA Touch Current Normal Condition (NC) Single Fault Condition (SFC) 90µA 170µA Input Specifications All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. Parameter Conditions/Description Min Nom Max Units Input Voltage 90 115/230 264 Vac Input Frequency 47 50/60 63 Hz Input Current 115Vac/max load 1.5 A Input Current 230Vac/max load 0.75 A Inrush Current 264Vac, cold start, 25°C - - 45 A Efficiency Vi nom, Io nom MINT3110A0508K01 MINT3110A1708K01 MINT3110A1908K01 - 87% - % Parameter Conditions/Description Min Nom Max Units Output Current V1 Output Current V2 Output Current V3 MINT3110A0508K01 0 0 0 10.0 4.5 1 14.0 6.0 1 ADC Output Current V1 Output Current V2 Output Current V3 MINT3110A1708K01 0 0 0 10.0 3.5 1 14.0 4.5 1 ADC Output Current V1 Output Current V2 Output Current V3 MINT3110A1908K01 0 0 0 8.0 3.0 1 12.0 4.0 1 ADC Output Specifications www.slpower.com MINT3110 REV 1.3, 12-NOV-12 4 MINT3110 110W Triple Output Medical Series Output Specifications (continued) Parameter Conditions/Description Min Nom Max Units Static Line Regulation V1 Vi min-Vi max, Vi nom, 0-100% Io1 max -2 - 2 % Vo nom Static Line Regulation V2 Vi min-Vi max, Vi nom, 0-100% Io2 max -3 - 3 % Vo nom Static Line Regulation V3 Vi min-Vi max, Vi nom, 0-100% Io3 max -10 - 10 % Vo nom Static Load Regulation V1 (Droop Characteristic) Vi min-Vi max, Vi nom, 0-100% Io1 max -2 - 2 % Vo nom Static Load Regulation V2 (Droop Characteristic) Vi min-Vi max, Vi nom, 0-100% Io2 max -3 - 3 % Vo nom Static Load Regulation V3 (Droop Characteristic) Vi min-Vi max, Vi nom, 0-100% Io3 max -10 - 10 % Vo nom Hold-Up Time Vin = 120Vac, Po = 110W 16 - - mS Dynamic Load Regulation V1, V2, V3 Load change =50%, di/dt = 0.2A/μS 0 3 % Vo nom Start-Up Time Vin = 115Vac, Io nom 0 2 S Ripple & Noise V1 20MHz bandwidth 0 1% % Vo nom Ripple & Noise V2 20MHz bandwidth 0 1% % Vo nom Ripple & Noise V3 20MHz bandwidth 0 2% % Vo nom Max Units - Protection All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. Parameter Conditions/Description Input Fuse T2.5A/250V internal fuse in both line & neutral Min Input Transient Protection 2KV(CM) and 1KV(DM) surge Nom Not user accessible 2 Short Circuit Protection Hiccup Mode Overload Protection Hiccup Mode Overvoltage Protection Latching Type, recycle AC input to reset KV (CM) See models chart for trip ranges Characteristic Curves Output vs. Temperature 80W convection cooled and 110W continuous with 200 LFM airflow. Derate output power to 50% at 70C. Output Power (W) 120 100 80 60 40 20 0 -10 0 10 20 30 40 50 60 70 Temperature (°C) Convection www.slpower.com 200LFM Cooling MINT3110 REV 1.3, 12-NOV-12 5