POWER-ONE MPB80-3000

MPB80 SERIES
The MPB80 combines high density power and other standard features
usually found in premium power systems. The low-profile package
neatly fits 1U height constraints in an industry-standard 3" X 5"
footprint. This Power Factor Corrected (PFC), multiple output
product line features overvoltage and overcurrent protection. In
addition to UL, CSA, and TÜV, regulatory agency compliances
include the CE Marking and harmonic compliance to EN61000-3-2.
FEATURES
• Power Factor Correction (PFC) Meets EN61000-3-2
• Low-Profile Height Fits 1U Constraints
• High 3.3V and 5V Current Capabilities Available
• CE Marked to Low Voltage Directive
• Autoranging AC Input, 85-264 VAC
• Overvoltage Protection on the Main Output
SINGLE OUTPUT MODEL SELECTION CHART – UP TO 72W CONVECTION COOLED, UP TO 100W FORCED AIR COOLED (300 LFM)
MODEL
MPB80-1012
MPB80-1024
MPB80-1048
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
CONVECTION COOLED
OUTPUT CURRENT
FORCED AIR
OUTPUT CURRENT
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%p-p (NOTE 1)
INITIAL SETTING
ACCURACY
12V
24V
48V
11V to 13V
22V to 26V
46V to 50V
6A
3A
1.5A
8.4A
4.2A
2.1A
0.5%
0.5%
0.5%
1%
1%
1%
1%
1%
1%
11.94V to 12.06V
23.88V to 24.12V
47.76V to 48.24V
NOTES: 1) Maximum peak-to-peak noise, bandwidth limited to 20 MHz.
DUAL AND TRIPLE OUTPUT MODEL SELECTION CHART – UP TO 63W CONVECTION COOLED, UP TO 80W FORCED AIR COOLED (300 LFM)
MODEL
MPB80-2000
MPB80-3000
MPB80-3300
(Note 2)
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
CONVECTION
COOLED CURRENT
FORCED AIR
CURRENT
LINE
REGULATION
TOTAL
REGULATION
RIPPLE & NOISE
mV (NOTE 1)
INITIAL SETTING
ACCURACY
+5V
+12V
+5V
+12V
-12V
+3.3V
+5V
+12V
4.7V to 5.8V
Fixed
4.7V to 5.8V
Fixed
Fixed
3.0V to 3.9V
4.7V to 5.8V
Fixed
11A/15A PK
0.5A/1A PK
7A/8.5A PK
2.5A/3A PK
0.3A/0.7A PK
7A/8.5A PK
3A/5A PK
0.4A/0.65A PK
15A
1A
8.5A
3A
0.7A
8.5A
5A
0.65A
0.8%
0.5%
0.5%
1.5%
0.5%
0.7%
0.5%
1.5%
-4%, +2%
±5%
-4%, +6%
-7%, +13%
±4%
±2%
±2%
-15%, +17%
1%
1%
1%
1%
1%
1%
1%
1%
4.9V to 5.1V
11.5V to 12.5V
4.9V to 5.1V
11.5V to 12.5V
-11.5V to -12.5V
3.27V to 3.33V
4.95V to 5.05V
10.2V to 14.0V
NOTES: 1) Maximum peak-to-peak noise, bandwidth limited to 20 MHz.
2) MPB80-3300 has overvoltage protection on +3.3V and +5V outputs.
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
Rev. 10/2000
1
MPB80 SERIES
INPUT SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
Input Voltage - AC
Input Frequency
Brown Out Protection
Hold-Up Time
Autoranging AC input automatically adjusts, no manual strapping required.
AC input.
Lowest AC input voltage that regulation is maintained with full rated loads.
After last AC line peak.
Full load @ 120 VAC
Full load @ 220 VAC
Single Output Models, 120 VAC
Single Output Models, 230 VAC
Dual and Triple Output Models, 120 VAC
Dual and Triple Output Models, 230 VAC
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 230 VAC (one cycle).
Switching frequency of main transformer.
85
47
85
16
20
Input Current
Input Protection
Inrush Surge Current
Operating Frequency
NOM
MAX
UNITS
264
63
VAC
Hz
VAC
mS
60
1.5
0.75
1.1
0.55
ARMS
32
68
APK
kHz
MAX
UNITS
OUTPUT SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
Efficiency
Minimum Loads
Full rated load, 230 VAC. Varies with distribution of loads among outputs.
Single Output Models
Minimum load required on V1 for regulation of V2, V3.
MPB80-2000
All other Multiple Output Models
Full load, 20 MHz bandwidth
Convection cooled, continuous output power.
MPB80-10XX
MPB80-2000
MPB80-3000
MPB80-3300
Forced air cooled, 300 LFM, or convection cooled, peak
MPB80-10XX
output power 10% duty cycle, 30 seconds maximum.
MPB80-2000
MPB80-3000
MPB80-3300
Output voltage overshoot/undershoot at turn-on.
Varies by output. Total regulation includes: line changes from 85-132 VAC or
170-264 VAC, changes in load starting at 20% load and changing to 100% load.
Recovery time, to within 1% of initial set point due to a 50-100% load change,
5% max. deviation.
Time required for initial output voltage stabilization.
Time required for output voltage to rise from 10% to 90%.
Ripple and Noise
Output Power
Overshoot / Undershoot
Regulation
Transient Response
Turn-On Delay
Turn-On Rise Time
MIN
NOM
73
%
0.0
1.5
0.7
See Model Selection Chart
72
61
63
43
100
80
80
61
2
Amps
Watts
Watts
%
See Model Selection Chart
500
µS
2
20
Sec
mS
INTERFACE SIGNALS AND INTERNAL PROTECTION
PARAMETER
CONDITIONS/DESCRIPTION
Overvoltage Protection
+3.3V 3.9
4.7
+5V, V1 & V2 5.8
6.8
12V 17.3
20.2
24V 32.2
37.8
48V 55.2
64.8
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
Overload Protection
MIN
2
NOM
MAX
UNITS
V
MPB80 SERIES
SAFETY, REGULATORY, AND EMI SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
AC Input Harmonic Distortion
Agency Approvals
In compliance per EN61000-3-2.
UL1950.
CSA 22.2 No. 234/950.
EN60950 (TÜV).
Input to output, 1 second.
FCC CFR title 47 Part 15.
EN55022 / CISPR 22
EN61000-4-5 class 3.
Input to output.
Per EN60950, 264 VAC.
Dielectric Withstand Voltage
Electromagnetic Interference,
Conducted
Input Transient Protection
Insulation Resistance
Leakage Current
MIN
NOM
MAX
UNITS
Approved
2600
B
B
2
10
VDC
Class
1.0
kV
M
mA
MAX
UNITS
10k
30k
ASL Ft.
50
70
85
95
20
6
°C
ENVIRONMENTAL SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
Altitude
Operating.
Non-Operating.
See model selection table for individual convection/forced air rating.
At 100% load.
Derate linearly above 50°C by 2% per °C.
Cooling
Operating Temperature
Storage Temperature
Relative Humidity
Shock
Vibration
MIN
Non-condensing.
Peak acceleration.
Random vibration, 10 Hz to 2 kHz, 3 axis.
3
0
0
-40
NOM
°C
%
GPK
GRMS
MPB80 SERIES
OVERALL SIZE: 5.00" x 3.00" x 1.40" (127.0mm x 76.2mm x 35.6mm)
COMPONENT HEIGHT: 1.26" (32.0mm)
WEIGHT: 0.8 LBS (0.36 kg)
0.156" DIA THRU
(3.96mm)
4 PLACES
4.550"
0.225"
(5.7mm)
(115 .6mm)
J2
J1
PIN 1
L
Input
Output
N
3.00"
(76.2mm)
2.550"
(64.8mm)
J3: 0.250 FASTON
SAFETY EARTH GROUND
5.00"
(127.0mm)
0.225"
(5.7mm)
J2
MPB80-2000
MPB80-3000
MPB80-3300
PIN 1
V1
PIN 1
V2
PIN 1
2
V1
2
V1
2
3
V1
3
V1
4
RTN
4
5
RTN
6
RTN
7
V2
V2
MPB80-10XX
PIN 1
V1
RTN
2
V1
3
RTN
3
V1
RTN
4
RTN
4
RTN
5
RTN
5
V1
5
RTN
6
V3
6
V1
6
RTN
7
V3
7
NC
INPUT CONNECTIONS, J1: MOLEX 26-60-4030 OR EQUIVALENT HEADER MATES WITH MOLEX HOUSING 09-50-3031 OR
EQUIVALENT AND PINS 08-50-0106 (18-20 AWG) OR 08-50-0108 (22-26 AWG) OR EQUIVALENT.
OUTPUT CONNECTIONS
SIX CONNECTOR J2: MOLEX 26-60-4060 HEADER MATES WITH MOLEX 09-50-3061 OR EQUIVALENT AND PINS 08-50-0106
(18-20 AWG) OR 08-50-0108 (22-26 AWG) OR EQUIVALENT.
SEVEN CONNECTOR J2: MOLEX 26-60-4070 HEADER MATES WITH MOLEX 09-50-3071 OR EQUIVALENT AND PINS 08-50-0106
(18-20 AWG) OR 08-50-0108 (22-26 AWG) OR EQUIVALENT.
CHASSIS: 0.090" (2.3mm) ALUMINUM ALLOY, WITH CLEAR FINISH.
4