MEANWELL NID30S48-24

NID30
12.5~30W DC-DC Non-isolated Single Output Converter
series
Features :
Economical open frame design
Wide input range
High efficiency up to 96%
Built-in remote ON / OFF control
Compact size 2.0" 0.512" 0.421"(SIP package)
Cooling by free air convection
Protections: Short circuit / Overload / Over voltage
100% burn-in test
Low cost / High reliability
2 years warranty
SPECIFICATION
ORDER NO.
OUTPUT
NID30S24-05
NID30S24-12
5V
12V
15V
24V
CURRENT RANGE
0 ~ 2.5A
0 ~ 2.5A
0 ~ 2A
0 ~ 1.25A
RATED POWER
12.5W
30W
30W
30W
120mVp-p
150mVp-p
200mVp-p
RIPPLE & NOISE (max.) Note.2 100mVp-p
LINE REGULATION
Note.3 0.5%
LOAD REGULATION
0.5%
Note.4
2.0%
SWITCHING FREQUENCY (Typ.) 250KHz
EXTERNAL CAPACITANCE LOAD (max.) 100uF / 25V low ESR
68uf/16V low ESR
47uf/50V low ESR
VOLTAGE RANGE
NORMAL VOLTAGE
20 ~ 53VDC
24VDC (or 48VDC)
20 ~ 53VDC
20 ~ 53VDC
24VDC (or 48VDC)
24VDC (or 48VDC)
48VDC
EFFICIENCY (Typ.)
91%
95%
96%
93%
Full load 590mA
1310mA
1320mA
700mA
No load
30mA
30mA
50mA
DC CURRENT
20mA
30 ~ 53VDC
Fuse recommended (3A)
120 ~ 300% rated output power
PROTECTION
OVERLOAD (Typ.)
Protection type : Hiccup mode, recovers automatically after fault condition is removed
All output equipped with short circuit
PROTECTION SHORT CIRCUIT
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Shut off o/p voltage, clamp by TVS diode
OVER VOLTAGE
-25 ~ +65
20% ~ 85%
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY -25 ~ +105
0.03% /
TEMP. COEFFICIENT
WORKING TEMP.
OTHERS
NID30S48-24
DC VOLTAGE
VOLTAGE ACCURACY
INPUT
NID30S24-15
(Refer to output load derating curve)
RH non-condensing
, 10 ~ 85% RH
(0 ~ 50
)
VIBRATION
10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes
REMOTE CONTROL
DIMENSION
Power on : 3.3VDC < R.C ~ com < 12VDC or open circuit ; power off : R.C ~ com < 0.4VDC or short circuit (PIN5,6 & PIN11)
50.8*13*10.7mm or 2.0"*0.512"*0.421" inch (L*W*H)
WEIGHT
8g
Derating Curve
Pin Configuration
Mechanical Specification
Unit:mm(inch)
8 [0.315]
6 7 8 9 1011
0.64 [0.025]
10.16 [0.40]
25.4 [1]
13 [0.512]
3.6 +1/-0[0.142]
1 2 3 4 5
1.3 [0.051]
SIDE
VIEW
Pin No.
Output
1,2,3,4
5,6
7,8
9,10
11
+ Vo u t
Com
+ Vi n
N.C.
R.C.
100
LOAD (%)
10.7[0.421]max.
50.8 [2]
80
50
5.6 [0.22]
2.54 [0.1]
-25
0
25
55 60 65
Ta (
NOTE
100
)
1.All parameters are specified at normal input, rated load, 25 70% RH Ambient.
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
3.Line regulation is measured from low line to high line at rated load.
4.Load regulation is measured from 10% to 100% rated load.
File Name:NID30-SPEC 2009-09-04