E Series Multifunction DAQ – 333 kS/s, 16-Bit, 16 Analog Inputs NI 6052E NI 6052E Driver Software PCI-6052E PXI-6052E NI-DAQ Windows 2000/NT/Me/9x Mac OS Analog Inputs 16 single-ended, 8 differential channels 333 kS/s sampling rate 333 kS/s stream-to-disk rate 16-bit resolution Analog Output Real-Time See page 184. Application Software LabVIEW Measurement Studio ComponentWorks VirtualBench Measure Lookout 2 channels,16-bit resolution Digital I/O 8 (5 V/TTL) lines Counter/Timers Calibration Certificate Included 2 up/down, 24-bit resolution See page 256. Triggering Analog and digital Overview Ordering Information NI 6052E PCI-6052E...........................................................777745-01 PXI-6052E ..............................................................777962-01 Includes NI-DAQ for Windows 2000/NT/Me/9x and Mac OS. Extended warranty and value added services ...........................................page 880 Recommended Configurations DAQ Device PCI-6052E PXI-6052E Accessory SCB-68 (776844-01) TBX-68 (777141-01) Cable SH6868-EP (184749-01) SH6868-EP (184749-01) See page 334 for accessory and cable information. Analog Bus Inputs PCI, PXI/CPCI 16 SE/8 DI Resolution 16 bits Sampling Rate 333 kS/s Input Range ±0.05 to ±10 V Analog Outputs 2 Resolution 16 bits Output Rate 333 kS/s Output Range ±10 V Digital I/O 8 Counter/ Timers 2, 24-bit Triggers Analog and Digital Table 1. NI 6052E Channel, Speed, and Resolution Specifications (see page 349 for detailed specifications) National Instruments Tel: (512) 794-0100 • Fax: (512) 683-9300 • [email protected] • ni.com Measurements Device NI 6052E EXPRESS The NI 6052E DAQ devices use E Series CODES technology to deliver high-performance and reliable data acquisition capabilities to For information or to meet a wide range of application buy products online, visit ni.com/catalog requirements. You get up to 333 kS/s, and enter: 16-bit performance on 16 single-ended pci6052e analog inputs. Depending on your type of pxi6052e hard drive, these devices can stream to disk at rates up to 333 kS/s. These NI 6052E DAQ devices feature analog and digital triggering capability, as well as two 24-bit, 20 MHz counter/timers, and eight digital I/O lines. The NI 6052E DAQ devices also feature two 16-bit analog outputs. See the E Series Multifunction DAQ Overview on page 306 for a more detailed hardware overview. 319 NI 6052E E Series Multifunction DAQ – 333 kS/s, 16-Bit, 16 Analog Inputs Absolute Accuracy Nominal Range (V) Positive FS % of Reading Negative FS 24 Hrs 1 Year Relative Accuracy Noise + Quantization (µV) Offset (µV) Single Pt. Averaged Temp Absolute Accuracy Drift (%/°C) at Full Scale (mV) Resolution (µV) Single Pt. Averaged 10 -10 0.0354 0.0371 947 981 87.0 0.0006 4.747 1145 5 -5 0.0054 0.0071 476 491 43.5 0.0001 0.876 573 115 2.5 -2.5 0.0354 0.0371 241 245 21.7 0.0006 1.190 286 28.6 1 -1 0.0354 0.0371 99.2 98.1 8.7 0.0006 0.479 115 11.5 0.5 -0.5 0.0354 0.0371 52.1 56.2 5.0 0.0006 0.243 66.3 6.6 0.25 -0.25 0.0404 0.0421 28.6 32.8 3.0 0.0006 0.137 39.2 3.9 0.1 -0.1 0.0454 0.0471 14.4 22.4 2.1 0.0006 0.064 27.7 2.8 0.05 -0.05 0.0454 0.0471 9.7 19.9 1.9 0.0006 0.035 25.3 0.0001 1.232 57.3 2.5 10 0 0.0054 0.0071 476 491 43.5 573 57.3 5 0 0.0354 0.0371 241 245 21.7 0.0006 2 0 0.0354 0.0371 99.2 98.1 8.7 0.0006 2.119 286 28.6 0.850 115 1 0 0.0354 0.0371 52.1 56.2 5.0 0.0006 0.428 66.3 11.5 6.6 0.5 0 0.0404 0.0421 28.6 39.8 3.0 0.0006 0.242 48.2 3.9 0.2 0 0.0454 0.0471 14.4 22.4 2.1 0.0006 0.111 27.7 2.8 0.1 0 0.0454 0.0471 9.7 19.9 1.9 0.0006 0.059 25.3 2.5 Note: Accuracies are valid for measurements following an internal E Series Calibration. Averaged numbers assume dithering and averaging of 100 single-channel readings. Measurement accuracies are listed for operational temperatures within ±1 °C of internal calibration temperature and ±10 °C of external or factory-calibration temperature. One-year calibration interval recommended. The Absolute Accuracy at Full Scale calculations were performed for a maximum range input voltage (for example, 10 V for the ±10 V range) after one year, assuming 100 pt averaging of data. See overview on page 312 for an example calculation of this type. Table 2. NI 6052E Analog Input Accuracy Specifications Nominal Range (V) Absolute Accuracy % of Reading Positive FS Negative FS Absolute Temp Accuracy at Full Scale (mV) 24 Hrs 90 Days 1 Year Offset (µV) Drift (%/°C) 10 -10 0.0044 0.0052 0.0061 798 0.0001 1.405 10 0 0.0044 0.0052 0.0061 569 0.0001 1.176 Note: Temp Drift applies only if ambient is greater than ±10 °C of previous external calibration. See page 312 for example calculations. See page 349 for more detailed specifications. Measurements Table 3. NI 6052E Analog Output Accuracy Specifications Figure 1. NI 6052E Hardware Block Diagram 320 National Instruments Tel: (512) 794-0100 • Fax: (512) 683-9300 • [email protected] • ni.com See page 310 in the E Series Multifunction DAQ Overview for I/O connector diagrams.