PLN-100 100W Single Output Switching Power Supply series Features : Universal AC input / Full range Protections: Short circuit / Overload / Over voltage / Over temperature Built-in active PFC function IP64 design for indoor or outdoor installations UL1310 Class 2 power unit Cooling by free air convection 100% full load burn-in test High reliability Suitable for LED lighting and moving sign applications 2 years warranty 110 F M EQUIVALENT MODEL PLN-100-27 PLN-100-36 PLN-100-48 12V 15V 20V 24V 27V 36V 48V 7.5 ~ 15V 10 ~ 20V 12 ~ 24V 13.5 ~ 27V 18 ~ 36V 24 ~ 48V Note.6 5A 5A 4.8A 4A 3.55A 2.65A 2A CURRENT RANGE Note.6 0 ~ 5A 0 ~ 5A 0 ~ 4.8A 0 ~ 4A 0 ~ 3.55A 0 ~ 2.65A 0 ~ 2A RATED POWER Note.6 60W 75W 96W 96W 95.85W 95.4W 96W 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p VOLTAGE ADJ. RANGE 0% ~ -15%. Can be adjusted by internal potential meter SVR1 CURRENT ADJ. RANGE 3% ~ -25%. Can be adjusted by internal potential meter SVR2 VOLTAGE TOLERANCE Note.3 3.0% LINE REGULATION 1.0% Note.5 90 ~ 264VAC 3.0% 2.0% 2.0% 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.95/230VAC EFFICIENCY (Typ.) 83% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 12V:0.8A/115VAC 0.4A/230VAC COLD START 40A/230VAC PF>0.95/115VAC at full load 85% 87% 87% 15V:0.9A/115VAC 87% 0.45A/230VAC 87% 20V ~ 48V:1.1A/115VAC 87% 0.55A/230VAC 0.5mA / 240VAC LEAKAGE CURRENT Note.4 PROTECTION OVER VOLTAGE OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE 95 ~ 100% Protection type : Constant current limiting, recovers automatically after fault condition is removed 13 ~ 16V 16.5 ~ 20V 22 ~ 27V 27 ~ 34V 29 ~ 36V 39 ~ 48V 52 ~ 64V Protection type : Shut down and latch off o/p voltage, re-power on to recover 90 10 (RTH2) Protection type : Shut down o/p voltage, re-power on to recover -30 ~ +50 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +80 , 10 ~ 95% RH 0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL1310 Class 2, UL879 ( listed in UL Sign Components Manual (SAM) ), TUV EN60950-1, EN61347-1, EN61347-2-13 CAN/CSA C22.2 No. 223-M91(except for 48V), IP64 approved I/P-O/P:4.25KVDC ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH EMI CONDUCTION & RADIATION Compliance to EN55015, EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2 Class C (>50% load) ; EN61000-3-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, light industry level, criteria A EMS IMMUNITY MTBF 303.1Khrs min. MIL-HDBK-217F (25 ) DIMENSION PACKING NOTE 3.0% 60ms/230VAC 30ms/115VAC at full load HOLD UP TIME (Typ.) OVER CURRENT 3.0% 1200ms, 80ms/230VAC 1200ms, 80ms/115VAC at full load SETUP, RISE TIME VOLTAGE RANGE 3.0% 2.0% LOAD REGULATION OTHERS IP64 PLN-100-24 RIPPLE & NOISE (max.) Note.2 150mVp-p EMC ( except for 48V ) PLN-100-20 RATED CURRENT SAFETY & ( for 48V only) PLN-100-15 DC VOLTAGE INPUT LPS PLN-100-12 CONSTANT CURRENT REGION Note.7 6 ~ 12V OUTPUT SELV M SPECIFICATION 200*70.5*35mm (L*W*H) 0.52Kg; 20pcs/11.4Kg/0.76CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Please refer to OLP characteristics. 5. Derating may be needed under low input voltage. Please check the derating curve for more details. 6. This is the maximum possible output current and power. Over load protection may be activated slightly below this level to comply with the requirement of UL1310 class 2. 7. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. File Name:PLN-100-SPEC 2008-08-18 PLN-100 100W Single Output Switching Power Supply Mechanical Specification Case No.955A series Unit:mm 200 22.84 6.26 2-R2.5 +V(Red) -V(Black) 18AWG 2C 22.84 18AWG 3C 310 10 DC OUT AC IN AC/L(Brown) AC/N(Blue) FG (Greed/Yellow) 70.5 310 10 35 6.26 Output voltage and current adjustment : remove the upper case and adjust through SVR1 & SVR2 shown in the diagram. SVR1 SVR2 SVR1 Output voltage adjustment SVR2 Output current adjustment Fosc : 100KHz Block Diagram EMI FILTER & RECTIFIERS I/P POWER SWITCHING PFC CIRCUIT RECTIFIERS & FILTER +V -V O.L.P. FG O.L.P. PFC CONTROL DETECTION CIRCUIT PWM & PFC CONTROL O.V.P. Derating Curve Static Characteristics Ta=25 100 100 90 80 80 70 LOAD (%) LOAD (%) 60 40 20 -30 -15 -5 0 15 30 40 AMBIENT TEMPERATURE ( ) 50 (HORIZONTAL) 60 50 40 90 100 125 135 145 155 165 175 180 200 230 264 INPUT VOLTAGE (V) 60Hz File Name:PLN-100-SPEC 2008-08-18