MEANWELL PLN-100-48

PLN-100
100W Single Output Switching Power Supply
series
Features :
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage / Over temperature
Built-in active PFC function
IP64 design for indoor or outdoor installations
UL1310 Class 2 power unit
Cooling by free air convection
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications
2 years warranty
110
F
M
EQUIVALENT
MODEL
PLN-100-27
PLN-100-36
PLN-100-48
12V
15V
20V
24V
27V
36V
48V
7.5 ~ 15V
10 ~ 20V
12 ~ 24V
13.5 ~ 27V
18 ~ 36V
24 ~ 48V
Note.6 5A
5A
4.8A
4A
3.55A
2.65A
2A
CURRENT RANGE
Note.6 0 ~ 5A
0 ~ 5A
0 ~ 4.8A
0 ~ 4A
0 ~ 3.55A
0 ~ 2.65A
0 ~ 2A
RATED POWER
Note.6 60W
75W
96W
96W
95.85W
95.4W
96W
150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
200mVp-p
VOLTAGE ADJ. RANGE
0% ~ -15%. Can be adjusted by internal potential meter SVR1
CURRENT ADJ. RANGE
3% ~ -25%. Can be adjusted by internal potential meter SVR2
VOLTAGE TOLERANCE Note.3
3.0%
LINE REGULATION
1.0%
Note.5 90 ~ 264VAC
3.0%
2.0%
2.0%
127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/230VAC
EFFICIENCY (Typ.)
83%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
12V:0.8A/115VAC 0.4A/230VAC
COLD START 40A/230VAC
PF>0.95/115VAC at full load
85%
87%
87%
15V:0.9A/115VAC
87%
0.45A/230VAC
87%
20V ~ 48V:1.1A/115VAC
87%
0.55A/230VAC
0.5mA / 240VAC
LEAKAGE CURRENT
Note.4
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
95 ~ 100%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
13 ~ 16V
16.5 ~ 20V
22 ~ 27V
27 ~ 34V
29 ~ 36V
39 ~ 48V
52 ~ 64V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
90
10
(RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
-30 ~ +50
(Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
0.03%/
(0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL1310 Class 2, UL879 ( listed in UL Sign Components Manual (SAM) ), TUV EN60950-1, EN61347-1, EN61347-2-13
CAN/CSA C22.2 No. 223-M91(except for 48V), IP64 approved
I/P-O/P:4.25KVDC
ISOLATION RESISTANCE
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
EMI CONDUCTION & RADIATION Compliance to EN55015, EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2 Class C (>50% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, light industry level, criteria A
EMS IMMUNITY
MTBF
303.1Khrs min. MIL-HDBK-217F (25 )
DIMENSION
PACKING
NOTE
3.0%
60ms/230VAC 30ms/115VAC at full load
HOLD UP TIME (Typ.)
OVER CURRENT
3.0%
1200ms, 80ms/230VAC 1200ms, 80ms/115VAC at full load
SETUP, RISE TIME
VOLTAGE RANGE
3.0%
2.0%
LOAD REGULATION
OTHERS
IP64
PLN-100-24
RIPPLE & NOISE (max.) Note.2 150mVp-p
EMC
( except for 48V )
PLN-100-20
RATED CURRENT
SAFETY &
( for 48V only)
PLN-100-15
DC VOLTAGE
INPUT
LPS
PLN-100-12
CONSTANT CURRENT REGION Note.7 6 ~ 12V
OUTPUT
SELV
M
SPECIFICATION
200*70.5*35mm (L*W*H)
0.52Kg; 20pcs/11.4Kg/0.76CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to OLP characteristics.
5. Derating may be needed under low input voltage. Please check the derating curve for more details.
6. This is the maximum possible output current and power. Over load protection may be activated slightly below this level to comply with the requirement
of UL1310 class 2.
7. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
File Name:PLN-100-SPEC 2008-08-18
PLN-100
100W Single Output Switching Power Supply
Mechanical Specification
Case No.955A
series
Unit:mm
200
22.84
6.26
2-R2.5
+V(Red)
-V(Black)
18AWG 2C
22.84
18AWG 3C
310 10
DC OUT
AC IN
AC/L(Brown)
AC/N(Blue)
FG (Greed/Yellow)
70.5
310 10
35
6.26
Output voltage and current adjustment : remove the upper case and adjust through SVR1 & SVR2
shown in the diagram.
SVR1
SVR2
SVR1 Output voltage adjustment
SVR2 Output current adjustment
Fosc : 100KHz
Block Diagram
EMI FILTER
&
RECTIFIERS
I/P
POWER
SWITCHING
PFC
CIRCUIT
RECTIFIERS
&
FILTER
+V
-V
O.L.P.
FG
O.L.P.
PFC
CONTROL
DETECTION
CIRCUIT
PWM & PFC
CONTROL
O.V.P.
Derating Curve
Static Characteristics
Ta=25
100
100
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
-30
-15
-5
0
15
30
40
AMBIENT TEMPERATURE ( )
50 (HORIZONTAL)
60
50
40
90
100
125
135
145
155 165
175
180
200
230
264
INPUT VOLTAGE (V) 60Hz
File Name:PLN-100-SPEC 2008-08-18