ROHM RPM6938-V4

Communication ICs
Remote control photosensitive IC
RPM6900 Series
The RPM6900 series are remote control photosensitive units in a compact, lightweight package made from a resin mold.
Applications
VCRs, TVs, movies, air conditioners, audio equipment,
and other household electrical appliances
RPM6900 series models
Features
1) Resin mold package enables a compact size and
light weight.
2) Built-in electromagnetic shield.
Absolute maximum ratings (Ta = 25C)
Recommended operating conditions
Note: Specifications may change without notice due to improvements in the product.
554
Communication ICs
RPM6900 Series
Block diagram
Electrical, optical characteristics (VCC = 5V, Ta = 25C)
555
Communication ICs
Measurement conditions
(1) Transmit signal
(2) Standard transmitter
λ peak=940nm
∆ λ=40nm
RPM6900 Series
(3) Measurement arrival distance, Horizontal & vertical
half angle
Arrival distance L:
Arrival distance at θ = 0 Fig.4
Horizontal & vertical half angle θ:
The angle which arrival distance became 50% of L.
(4) High level, low level output voltage
When standard transmitter output the signal at Fig.1
standard photodiode output become io = 5µ AP-P under
the measurement condition Fig2, Fig.3.
RPM-301B: standard photodiode has short current ISC
= 27µ A at E = 10001x
(using CIE standard light source A)
556
Communication ICs
RPM6900 Series
FMeasurement circuit
FRecommended application
S Please place filter (resistors and capacitors) as close to the receiver as possible.
S In order to stable operation, using serial resistor (47Ω) on power supply line and capacitor (more than 47µF) between
power supply and GND is recommended.
(This reduce influence by switching power supply ripple and ripple which caused by the change of micro controller load
and other circuits load.)
Without the above circuit, Arrival distance might be less due to noise pulse on output wave.
(In case even with the above mentioned value, please change bigger capacitance.)
FOperation notes
(1) All characteristics of the receiver in this specification
are specified by supplying burst wave form with ROHM
standard transmitter (Fig.2).
If in case of other burst wave form will be used, please
check these spec. Carefully under the evaluations.
(2) When the receiver will be used as the wire-less remote controller, please use the signal method the signal
format which refer to “Measures to prevent miss-functioning of IR remote-controlled electric home appliances”.
(Published July 1987 by Association of Electric Home
Appliances)
However, please use the standard pulse width (T) of
greater than 0.4ms and less than 0.6ms (0.4ms < T <
0.6ms)
If using other signal method, signal format, (ex: signal format which not including the leader signal) the receiver
might have chances to miss-function.
557
Communication ICs
RPM6900 Series
(3) Please set up transmitter’s carrier frequency as
same as the receiver’s f0 frequency. Otherwise error
might be occurred.
(4) If transmission signal has non-continues carrier, error might be occurred. Continuous carrier is necessary.
(5) The receiver was designed to use as in-door use
only. Therefore, please understand that the receiver cannot cover all characteristics, in case of using it out-door.
(6) Emitting unit (remove control transmitter) has to be
considered about its emitting device function, characteristics and characteristics of the receiver.
(7) Do not supply unnecessary stress to lead and holder.
(8) Please pay careful attention to the lens.
It might has a chance to miss-function when the lens get
dust or dirty. And also please do not touch the lens.
(9) In order to prevent IC from ESD, human body, solder
iron, etc are required to be grounded.
Electrical, optical characteristics curves
558
Communication ICs
RPM6900 Series
External dimensions (Units: mm)
559