Filename: tfs 70ax.doc Version 1.2 VI TELEFILTER 28.07.2006 Filter specification TFS 70AX 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 0 °C dBm 1580 Ω || -11,1 pF 1360 Ω || -12,3 pF Characteristics Remark: The reference level for the relative attenuation arel of the TFS 70AX is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 2 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 70 MHz without any tolerance. The given values for both the relative attenuation arel and the group delay ripple have to be achieved at the frequencies given below even if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc. Data typ. value Insertion loss (reference level) ae 8,1 Nominal frequency fN - Centre frequency fC 70,0 Pass band ripple max. MHz fN 0,7 2,0 5,0 10,6 dB 70,0 MHz fN ± 0,25 MHz 0,3 dB max. 1 dB 0,7 dB max. 1 dB dB dB dB min. min. min. 35 45 50 dB dB dB µs max. 3 µs 225 ns max. 500 ns - 95 dBm min. -70 dBm - max. 15 dBm - - 40 °C ... + 85°C arel Relative attenuation ± ± ± dB PB Passband fN fN fN tolerance / limit … fN ± MHz … fN MHz … fN MHz … fN ± ± ± 0,25 2,0 5,0 69,7 Group delay MHz MHz MHz MHz mean value in PB Group delay ripple within PB Intermodulation ** Input power level Operating temperature range OTR 2,6 - Storage temperature range Frequency inversion temperature Temperature coefficient of frequency 40 52 60 TCf *** - 55 °C ... +105°C 20 °C -0,04 ppm/K 2 *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) fin1= 69,95 MHz; fin2= 69,9 MHz; Pin= -10 dBm fmeasurement = 70,0 MHz and fin1= 70,05 MHz; fin2= 70,1 MHz; Pin= - 10 dBm fmeasurement = 70,0 MHz. ***) ∆f(Hz) = TCf(ppm/K²) x (T-T0)² x fTo(MHz) Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 70ax.doc Version 1.2 VI TELEFILTER 28.07.2006 Filter specification TFS 70AX 2/5 0 0 5.8 -7 -1 5.44 -14 -2 5.08 -3 4.72 -4 4.36 -5 4 -6 3.64 -7 3.28 -8 2.92 -9 2.56 -21 magnitude in dB magnitude in dB -28 -35 -42 delay in µs Filter characteristic -49 -56 -63 -70 60 62 64 66 68 70 frequency in MHz 72 74 76 78 -10 69.5 80 69.6 69.7 69.8 69.9 70 70.1 frequency in MHz 70.2 70.3 70.4 2.2 70.5 Construction and pin connection (All dimensions in mm) 10 +0,20 6,50 - 0,10 6 TFS 70AX ● U30 5 Date code Input RF Return Ground Ground Ground Output Output RF Return Ground Ground Ground Input Date code: U V W ... Year + week 2006 2007 2008 1,02 2,31 1 +0,20 19 - 0,10 2,0 Max. 1 1 2 3 4 5 6 7 8 9 10 1,91 7,62 50 Ω Test circuit L1 10 1 5 SAW L2 6 C2 C1 2, 3, 4, 7, 8, 9 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 70ax.doc Version 1.2 VI TELEFILTER 28.07.2006 Filter specification TFS 70AX 3/5 Stability characteristics, reliability After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: three times max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; This filter is RoHS compliant (2002/95/EG, 2005/618/EG) Packing Tape & Reel: IEC 286 – 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer: Pull Off Direction Po Date Code P1 P2 Ao Ct Bo So Do E t Ko W Tape (all dimensions in mm) W : 32,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,1 F : 14,20 ± 0,1 P2 : 2,00 ± 0,1 P1 : 12,00 ± 0,1 D1(min) : 2,00 Ao : 7,10 ± 0,1 Bo : 19,60 ± 0,1 So : 28,40 ± 0,1 Ct : 25,5 ± 0,1 2000 min. 300 mm min. 500 mm min. 300 mm Type Reel (all dimensions in mm) A : 330 W1 : 32,4 +2/-0 W2(max) : 38,4 N(min) : 100 C : 13,0 +0,5/-0,2 PIN Marker D1 W2 C A N W1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 70ax.doc Version 1.2 VI TELEFILTER 28.07.2006 Filter specification TFS 70AX 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s History Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 70ax.doc VI TELEFILTER Version 1.2 Filter specification 28.07.2006 TFS 70AX 5/5 Version Reason of Changes Name Date 1.0 - Generation of development specification Strehl 20.02.2006 1.1 - Change relative attenuation and add group delay ripple Strehl 23.03.2006 1.2 - add of terminating impedances, typical values, filter characteristics and matching configuration Pfeiffer 28.07.2006 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.