TFS70AX

Filename: tfs 70ax.doc
Version 1.2
VI TELEFILTER
28.07.2006
Filter specification
TFS 70AX
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
0
°C
dBm
1580 Ω || -11,1 pF
1360 Ω || -12,3 pF
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 70AX is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 2 dB
filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 70 MHz without any tolerance. The given values for both the
relative attenuation arel and the group delay ripple have to be achieved at the frequencies given below even if the centre frequency fc is shifted due to the
temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc.
Data
typ. value
Insertion loss
(reference level)
ae
8,1
Nominal frequency
fN
-
Centre frequency
fC
70,0
Pass band ripple
max.
MHz
fN
0,7
2,0
5,0
10,6
dB
70,0
MHz
fN
±
0,25 MHz
0,3
dB
max.
1
dB
0,7
dB
max.
1
dB
dB
dB
dB
min.
min.
min.
35
45
50
dB
dB
dB
µs
max.
3
µs
225
ns
max.
500
ns
- 95
dBm
min.
-70
dBm
-
max.
15
dBm
-
- 40 °C ... + 85°C
arel
Relative attenuation
±
±
±
dB
PB
Passband
fN
fN
fN
tolerance / limit
… fN
±
MHz … fN
MHz … fN
MHz … fN
±
±
±
0,25
2,0
5,0
69,7
Group delay
MHz
MHz
MHz
MHz
mean value in PB
Group delay ripple within PB
Intermodulation
**
Input power level
Operating temperature range
OTR
2,6
-
Storage temperature range
Frequency inversion temperature
Temperature coefficient of frequency
40
52
60
TCf ***
- 55 °C ... +105°C
20
°C
-0,04
ppm/K
2
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) fin1= 69,95 MHz; fin2= 69,9 MHz; Pin= -10 dBm fmeasurement = 70,0 MHz and fin1= 70,05 MHz; fin2= 70,1 MHz; Pin= - 10 dBm fmeasurement = 70,0 MHz.
***) ∆f(Hz) = TCf(ppm/K²) x (T-T0)² x fTo(MHz)
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 70ax.doc
Version 1.2
VI TELEFILTER
28.07.2006
Filter specification
TFS 70AX
2/5
0
0
5.8
-7
-1
5.44
-14
-2
5.08
-3
4.72
-4
4.36
-5
4
-6
3.64
-7
3.28
-8
2.92
-9
2.56
-21
magnitude in dB
magnitude in dB
-28
-35
-42
delay in µs
Filter characteristic
-49
-56
-63
-70
60
62
64
66
68
70
frequency in MHz
72
74
76
78
-10
69.5
80
69.6
69.7
69.8
69.9
70
70.1
frequency in MHz
70.2
70.3
70.4
2.2
70.5
Construction and pin connection
(All dimensions in mm)
10
+0,20
6,50 - 0,10
6
TFS 70AX
●
U30
5
Date code
Input RF Return
Ground
Ground
Ground
Output
Output RF Return
Ground
Ground
Ground
Input
Date code:
U
V
W
...
Year + week
2006
2007
2008
1,02
2,31
1
+0,20
19 - 0,10
2,0 Max.
1
1
2
3
4
5
6
7
8
9
10
1,91
7,62
50 Ω Test circuit
L1
10
1
5
SAW
L2
6
C2
C1
2, 3, 4, 7, 8, 9
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 70ax.doc
Version 1.2
VI TELEFILTER
28.07.2006
Filter specification
TFS 70AX
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: three times max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
Pull Off Direction
Po
Date Code
P1
P2
Ao
Ct
Bo
So
Do
E
t
Ko
W
Tape (all dimensions in mm)
W
: 32,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 14,20 ± 0,1
P2
: 2,00 ± 0,1
P1
: 12,00 ± 0,1
D1(min)
: 2,00
Ao
: 7,10 ± 0,1
Bo
: 19,60 ± 0,1
So
: 28,40 ± 0,1
Ct
: 25,5 ± 0,1
2000
min. 300 mm
min. 500 mm
min. 300 mm
Type
Reel (all dimensions in mm)
A
: 330
W1
: 32,4 +2/-0
W2(max) : 38,4
N(min)
: 100
C
: 13,0 +0,5/-0,2
PIN Marker
D1
W2
C
A
N
W1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 70ax.doc
Version 1.2
VI TELEFILTER
28.07.2006
Filter specification
TFS 70AX
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
History
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 70ax.doc
VI TELEFILTER
Version 1.2
Filter specification
28.07.2006
TFS 70AX
5/5
Version
Reason of Changes
Name
Date
1.0
- Generation of development specification
Strehl
20.02.2006
1.1
- Change relative attenuation and add group delay ripple
Strehl
23.03.2006
1.2
- add of terminating impedances, typical values, filter characteristics and matching configuration Pfeiffer
28.07.2006
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.