VI TELEFILTER Filter specification TFS 90B 1/5

Filename: tfs 90b.doc
Version 1.5
VI TELEFILTER
11.01.2008
Filter specification
TFS 90B
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
0
°C
dBm
1000 Ω || -18,0 pF
900 Ω || -17,9 pF
Characteristics
Remark:
The nominal frequency fN is fixed at 90,0 MHz. The insertion loss ae is defined as loss value determined at fN. Reference level for the relative attenuation
arel of the TFS 90B is the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 2 dB filter
attenuation level relative to the insertion loss ae. All specified data are met within the operating temperature range.
Data
typ. value
Insertion loss
(reference level)
ae
10,9
Nominal frequency
fN
-
Centre frequency
fC
90,0
PB
Passband
p-p
Pass band ripple
dB
tolerance / limit
max.
MHz
-
13,0
dB
90,0
MHz
fN
±
max.
1,8
MHz
2
dB
0,7
dB
3,8
4,2
MHz
MHz
0,3
0,6
dB
dB
max.
max.
0,6
2,5
dB
dB
dB
dB
dB
dB
dB
dB
min.
min.
min.
min.
min.
min.
40
30
25
6,5
40
30
dB
dB
dB
dB
dB
dB
µs
max.
Bandwidth
1
3
dB
dB
arel
Relative attenuation
fN
fN
±
fN
fN
fN
fN
fN
fN
±
±
±
+
+
1,5
80
15
10
6
15
80
-
... fN
MHz ... fN
±
±
1,5
1,8
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
±
±
±
+
+
15
10
6
2,5
80
910
MHz
MHz
MHz
MHz
MHz
MHz
...
...
...
...
...
...
fN
fN
fN
fN
fN
fN
Group delay
48
38
30
13
44
38
0,65
at fN
0,75
µs
Group delay variation in fN ± 1,2 MHz
p-p
80
ns
max.
120
ns
Group delay variation in PB
p-p
100
ns
max.
180
ns
dBm
min.
30
dBm
max.
6
dBm
42
Intermodulation **
-
Input power level
Operating temperature range
OTR
Storage temperature range
Temperature coefficient of frequency
TCf ***
-
-40 °C..... +85 °C
-
-55 °C..... +85 °C
-33
ppm/K
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values
only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) fin1= 89,4 MHz; fin2= 89,7 MHz; Pin= 0 dBm fmeasurement = 90,0 MHz
***) ∆fc(Hz) = TCf(ppm/K) x (T - To) x fTo (MHz).
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 90b.doc
Version 1.5
VI TELEFILTER
11.01.2008
Filter specification
TFS 90B
2/5
0
1.68
-1
1.56
-12
-2
1.44
-18
-3
1.32
-24
-4
1.2
-5
1.08
-6
0.96
-42
-7
0.84
-48
-8
0.72
-54
-9
0.6
-30
-36
-60
40
50
60
70
80
90
100
frequency in MHz
110
120
130
-10
88
140
88.4
88.8
89.2
89.6
90
90.4
frequency in MHz
90.8
91.2
91.6
delay in µs
0
-6
magnitude in dB
magnitude in dB
Filter characteristic
0.48
92
Construction and pin connection
(All dimensions in mm)
S 90B
● W02
3
Date code
2 Max.
1
Input
Input RF Return
Ground
Ground
Ground
Ground
Output
Output RF Return
Ground
Ground
Ground
Ground
Date code:
W
X
A
...
Year + week
2008
2009
2010
1
5,2 Max.
2,54 ±0,2
7,2 Max.
2,54 ±0,2
1
1
2
3
4
5
6
7
8
9
10
11
12
0,80
Base material ceramic; plating Au >1,0µm over Ni >2µm
50 Ohm Test circuit
1
L1
2
7
SAW
L2
L3
8
L4
3, 4, 5, 6, 9, 10, 11, 12
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 90b.doc
Version 1.5
VI TELEFILTER
11.01.2008
Filter specification
TFS 90B
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
3000g shock, per MIL-STD 883, procedure 2002.4, condition C
5000g shock, per MIL-STD 883, procedure 2002.4, condition D
2. Vibration:
20g, per MIL-STD 883, procedure 2007.3, condition A
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: three times max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
3000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
Tape (all dimensions in mm)
W
: 16,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 7,50 ± 0,1
G(min)
: 0,60
P2
: 2,00 ± 0,1
P1
: 8,00 ± 0,1
D1(min)
: 1,50
Ao
: 5,50 ± 0,1
Bo
: 7,50 ± 0,1
Ct
: 13,5 ± 0,1
P1
Date Code
Po
Do
P2
W
G
Ct
Bo
F
G
E
t
Ko
Typ
PIN Marker
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 16,4 +2/-0
W2(max) : 22,4
N(min)
: 50
C
: 13,0 +0,5/-0,2
C
A
N
W 1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 90b.doc
Version 1.5
VI TELEFILTER
11.01.2008
Filter specification
TFS 90B
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 90b.doc
VI TELEFILTER
Version 1.5
Filter specification
11.01.2008
TFS 90B
5/5
History
Version
Reason of Changes
Name
Date
1.0
- generation of development specification
Strehl
12.05.2006
1.1
- extend of storage temperature range
Strehl
17.05.2006
1.2
- terminating impedances, typical values, filter characteristics and matching configuration added
- frequencies of input signals for intermodulation measurements corrected
Pfeiffer
29.08.2006
1.3
- temperature coefficient of frequency and typical values corrected
- change of relative attenuations
Pfeiffer
31.08.2006
1.4
- add plating in construction
Strehl
15.05.2007
1.5
- change stability characteristics
Strehl
11.01.2008
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.