AC/DC POWER HiTESTER 3334 POWER HiTESTER 3333 Power Measuring Instruments By Popular Demand Ideal for Meeting Energy Efficiency Standards High Accuracy & Cost Performance All in One Device Choose the 3334 for DC and Current/Power Integration Applications 3334 ■ High Accuracy (±0.1% rdg. ±0.1% f.s. for 1 year) Exceeds the 0.5% accuracy benchmark stipulated by international standards. ■ Extended Period of Guaranteed Accuracy of 3 Years Calibration expenses are reduced by a calibration interval six times that of our former models. ■ Maximum Cost Performance All the necessary functions and accuracy requirements are provided in an easy-to-use, no-frills device. 3333 2 The HIOKI AC/DC POWER HiTESTER Solves All of 3334 AC/DC POWER All the Features for DC and Current/Power Integration Measurements ■ Complete Accuracy Over a Wide Input Range 1.00mA 0.150V 0.0000W ■ All Measurements Within this Range Fully Guaranteed for Accuracy Current: 1mA to 30A, Voltage: 0.15V to 300V, Apparent Power: 0W to 9kW Measure AC or DC Loads With a DC to 5kHz frequency bandwidth, all AC and DC measurement and AC/DC elements such as half-wave rectified values can be tested reliably and accurately [AC+DC Mode]: For half-wave rectified loads common in small household appliances such as hair dryers [DC Mode]: For pure DC loads in batteries [AC Mode]: For loads in commercial power lines powering common household appliances 30.00A 300.0V 9.000kW ■ Capture Inrush Current with the Peak Measurement Function Measure for the Peak Value of Voltage and Current for Each Polarity Indepedently. Also measure the inrush current or surge current of electrical equipment. Measure simply by pressing the SHIFT+HOLD keys. inrush current Switch modes simply by pressing the DC/AC button on the panel Measure the inrush current when copiers and similar equipment are started Half-wave rectified 0.0 A peak current All waves rectified 0.0 A Some hair dryers operate by switching the output by a half-wave rectified. Measure the peak current of the standby power of home entertainment devices 80% of Actual Size Shown ■ Intuitive Setting Procedures and Easy-to-Understand Displays Both the 3333 and 3334 offer simple operating procedures and quick and easy-to-understand readings and alarm displays. Settings can be made for obtaining the average of captured data (AVG), VT ratio (conversion ratio), CT ratio, GP-IB address, integration time (from 1 minute to 10,000 hours), and D/A Output Parameters. Information regarding the Power HiTESTER's currents status such as display hold, remote control settings, and key lock (to prevent unauthorized reconfigurations) can be viewed at a glance. *Easily test for over-consumption even when testing distorted waveforms that are commonly found in switching power supplies and similar devices by monitoring for the [PEAK OVER] alarm, simply by setting for the alarm to activate and the display to light up when the input exceeds the range. 3 your Energy Consumption Testing Needs ● Meet Industrial Standard Requirements for Test Accuracy ● Measure for Consumed Power Also ideal for measuring the standby power and power consumption level of household appliances ■ AC/DC Current and Power Integration Even measure the discharge level of each individual polarity of batteries ■ Accurate Even for Waveforms with Large Crest Factors Reliably test waveforms with large crest factors (peak value with respect to the RMS value) such as pulsed systems *Highest effective peak voltage and peak current values on the 3334 are 300% of the range. Accuracy is guaranteed for 1% to 100% of both ranges. 300mA peak to peak Measure the amount of solar generated power and how much is being sold back to the power company ■ Universal Devices that are highly vulnerable to power fluctuations such as copiers and cycle-controlled equipment can also be measured for integrated power 1mA rms For example, in the 100mA range where the RMS value= 1mA Peak value= 300mA, CF=300 Even waveforms such as this can be measured accurately with the 3334. Power Supply ■ Easy-to-connect Terminals Compatible to 100 - 240V AC Power Supplies Make a secure connection with the screw-type terminals *Use a No.3 Phillips screwdriver ■ Small Actual Size Footprint Leading edge technology and innovations helped to minimize the space required, while still enabling DC measurements. *Standard rack mount kits also available upon special order. Rear Panel Design of Model 3334-01 with built-in GP-IB Interface ■ Analog 210 Output on All 4 Channels •Simultaneously ouput the voltage, current and active power values (DC ±2 V f.s., data refreshed 5 times/second) •Output the apparent power, power factor, or integrated current/active power over an additional 1 channel ■ Waveform Voltage Active power 15 Integrated active power Output over 3 Channels Instantaneous waveforms of Waveform of a motor startup the measured voltage, current and active power can be simultaneously output •Output: 1 V f.s. •Sampling speed: 74.4kHz (at 50Hz: 1488 points/waveform) (at 60Hz: 1240 points/waveform) 100 Current Voltage Current Active power ■ Data management with PC Ask your distributor for more information regarding the freeware for processing your measurement data Make full use of these interfaces to increase efficiency •RS-232C (3334) •RS-232C, GP-IB (3334-01) 4 Fully Answering the Needs for a High Accuracy, Long-lasting, and User- 3333 AC POWER Accuracy That Can Only Be Realized with a Digital Display ■ Multifunctional - 3 Meters In One ■ Selectable simultaneous display of voltage, current, power (active or apparent) or power factor Display a: voltage, current or active power Display b: current, active power or apparent power Display c: active power, power factor, voltage or current Press the SET key to display settings Display a: AVG setting (number of samples to average) convenient for displaying severely fluctuating values Display b: VT (voltage transformer) ratio setting Display c: CT (current transformer) ratio setting To expand the measurement input level, VT and CT ratios can be set for transformer measurements. Primary winding input values can be read directly. Operation: Press the a, b or c key to switch between parameters ■ Quick and Simple Settings Easy-to-see display Bright emissive numeric and unit symbol display Operation: Press NEXT or the a, b or c key to select a setting item Actual Size ■ Clearly visible instrument status ■ Warning lights indicate out-of-range input to Model 3333 when measuring voltage and current of distorted waveforms, such as in power switching circuits. Display hold, remote control and key-lock states are indicated separately. ■ Easy range setting Select current range simply by pressing the button (accepts up to 30 AAC, including auto-ranging) No voltage range setting required (accepts up to 300 VAC) Check for Errors at a Glance ■ Convenient functions 1. Key Lock (SHIFT + KEY LOCK keys) Useful for avoiding inadvertent operations on production lines. 2. Data Print (SHIFT + DATA OUT keys) Obtain hard copies of measurement data using the optional Printer Model 9442. 5 Friendly Power Measuring Device for the Production and Inspection Lines Digital Display Data management on a PC Cost-Performance ■ 100 Easy Operation What are the advantages? Model 3333 fully exceeds the accuracy level of traditional analog meters that has an accuracy of only ±0.5% f.s. ±0.5% f.s is assured for a full three years, reducing calibration costs and production time losses Gone is the need to check for zero-position before measurement as210you would on traditional261analog meters 7 30 Quickly grasp the measurement data at a glance Facilitate reporting and data recording needs using your computer Take care of a multitude of measurement needs with a single low-cost instrument 15 Model 3333 Measurement accuracy: ±0.5% rdg. or better Period of guaranteed accuracy (Recommended calibration interval): 3 years Universal Power Supply ■ Easy-to-connect Terminals 210 7 261 34 Screw-in terminal block affixes wires securely. Because bad wiring connections can present a fire hazard, the screw-type terminal block has been incorporated to ensure secure wiring. 15 100 Compatible to 100 - 240V AC Power Supplies *Be sure to use a No. 3 Phillips screwdriver (available as an optional accessory) to loosen and secure the screws. Actual Size ■ Space-saving footprint Smaller installation space. The installed footprint of the POWER HiTESTER 3333 is about 34% smaller than that of former models. This size reduction makes the instrument especially easy to install. *Rack mounts for various installations also available on special order. Please inquire for details. Rear Panel Design of Model 3333-01 with built-in GP-IB Interface 160 ■ Three-channel analog output 100 Voltage, current and active power measurements are simultaneously output as +2 VDC f.s. levels (refreshed about five times per second). 15 ■ Connect to Printer Model 9442 Use the optional Printer Model 9442 to print without concern for troublesome settings. ■ PC measurement and data management ❍ RS-232C interface built-in ❍ Select Model 3333-01 for additional built-in GP-IB interface 6 ■ 3334 and 3333 Specifications 3334 (AC/DC) 3333 (AC) ● General Specifications Measurable lines Single-phase, 2-wire (AC/DC) Single-phase, 2-wire (AC) Voltage, current, active power, apparent power, power factor, Voltage, current, active power, apparent power, power factor Measurement parameters frequency, integrated current and active power, waveform peak (voltage and current) Measurement method Simultaneous digital sampling of voltage and current, True RMS Sampling Frequency Approximately 74.4kHz Measurement Range Switch between auto-range or manual Approximately 48kHz Voltage 15.000/ 30.00/ 150.00/ 300.0V 200.0V Current 100.00m/ 300.0m/ 1.0000/ 3.000/ 10.000/ 30.00A 50.00m/ 200.0m/ 500.0m/ 2.000/ 5.000/ 20.00A Power 1.5000W to 9.000kW (refer to range composition table below) 10.000W to 4.000kW (refer to range composition table below) Frequency bandwidth DC, 45Hz to 5kHz ● Accuracy Guaranteed at 23°C±5, max. 80%rh, sine wave input, power factor=1, in-phase voltage =0V (accuracy specifications differ depending on usage period of 1 or 3 years) 45Hz to 5kHz Warm-up time 3 minutes 10 minutes Period of guaranteed accuracy 3 years (better accuracy specifications available for 1-year period) Effective measurement range Voltage, current:1% to 100% (Power: 0% to 100%) Voltage, current, power: 10% to 150% Effect of power factor (at pf=0.5) Maximum ±0.4%±rdg. (45 to 66Hz) Temperature Coeffi cient Maximum ±0.03%f.s./ºC Values in the ( ) represent the effective measurement range Measurements below 0.5% of the voltage or current range will be zero suppressed. ●Measurement ranges - Model 3334 Current 100.00mA 300.0mA (1.00 to 100.00mA) Voltage 15.000V (0.150 to 15.000V) 30.00V (0.30 to 30.00V) 150.00V (1.50 to 150.00V) 300.0V (3.0 to 300.0V) 1.5000W (3.0 to 300.0mA) (0.0000 to 1.5000W) 3.000W (0.000 to 3.000W) 15.000W (0.000 to 15.000W) 30.00W (0.00 to 30.00W) 4.500W (0.000 to 4.500W) Current 50.00mA (5.00 to 75.00mA) 200.0V (20.0 to 300.0V) 10.000W (1.000 to 15.000W) 15.000W (0.000 to 15.000W) 9.000W 30.00W (0.000 to 9.000W) 45.00W (0.00 to 45.00W) (0.00 to 30.00W) 150.00W (0.00 to 150.00W) 90.00W 300.0W (0.00 to 90.00W) ●Measurement ranges - Model 3333 Voltage 1.0000A (0.0100 to 1.0000A) (0.0 to 300.0W) 3.000A (0.030 to 3.000A) 45.00W (0.00 to 45.00W) 90.00W (0.00 to 90.00W) 450.0W (0.0 to 450.0W) 900.0W (0.0 to 900.0W) 10.000A (0.100 to 10.000A) 150.00W (0.00 to 150.00W) 300.0W (0.0 to 300.0W) 1.5000kW (0.0000 to 1.5000kW) 3.000kW (0.000 to 3.000kW) 200.0mA (20.0 to 300.0mA) 40.00W (4.00 to 15.000W) 500.0mA (50.0 to 750.0mA) 100.00W (10.00 to 15.00W) 2.000A (0.200 to 3.000A) 400.0W (40.0 to 600.0W) 5.000A (0.500 to 7.500A) 1.0000kW (0.1000 to 1.5000kW) Guaranteed Voltage, current and active power Current and active power Period (at less than 50% of input range) (at 50% to 100% of input range) 1 year ±0.1%rdg.±0.2%f.s. 3 years ±0.1%rdg.±0.35%f.s. 1 year ±0.1%rdg.±0.1%f.s. ±0.2%rdg. 45 Hz ≤ f ≤ 66 Hz 3 years ±0.1%rdg.±0.2%f.s. ±0.3%rdg. 1 year ±0.1%rdg.±0.2%f.s. ±0.3%rdg. 66 Hz < f ≤ 1 kHz 3 years ±0.1%rdg.±0.35%f.s. ±0.45%rdg. 1 year ±3.0%f.s. ±3.0%rdg. 1 kHz < f ≤ 5 kHz 3 years ±4.5%f.s. ±4.5%rdg. *Add ±50µA to the accuracy when measuring DC current *Add (±50µA x voltage value) to the accuracy when measuring DC active power Notes DC Accuracy not defined for c u r re n t i n p u t exceeding 20A ●Measurement accuracy - Model 3333 Values in the ( ) indicate accuracy when input exceeds 100% of range. Frequency 45 Hz ≤ f ≤ 66 Hz 66 Hz < f ≤ 1 kHz 1 kHz < f ≤ 5 kHz Guaranteed Voltage, current and active power Current and active power Period (input current 20 A or less) (input current over 20 A) 1 year 3 years 1 year 3 years 1 year 3 years 450.0W (0.0 to 450.0W) 900.0W (0.0 to 900.0W) 4.500kW (0.000 to 4.500kW) 9.000kW (0.000 to 9.000kW) Values in the ( ) represent the effective measurement range Measurements below 0.5% of the voltage, current , or power range will be zero suppressed. ●Measurement accuracy - Model 3334 Frequency 30.00A (0.30 to 30.00A) ±0.1%rdg.±0.1%f.s. (±0.2%rdg.) ±0.1%rdg.±0.2%f.s. (±0.3%rdg.) ±0.1%rdg.±0.2%f.s. (±0.3%rdg.) ±0.1%rdg.±0.35%f.s. (±0.45%rdg.) ±3.0%f.s. (±3.0%rdg.) ±4.5%f.s. (±4.5%rdg.) Notes Accuracy not defined for c u r re n t i n p u t exceeding 20A 20.00 A (2.00 to 30.00A) 4.000kW (0.400 to 6.000kW) ●3334 and 3333 Arithmetic Expressions Measurement Formula Parameters Apparent Power S=U×I (S) Power Factor (λ) λ=⎥P/S⎥ (Sum of I from start of integration) Integrated Current (1 hour of data) Integrated Active (Sum of P from start of integration) Power (1 hour of data) *U=Tested Voltage Value, I=Tested Current Value, P=Tested Active Power Value Calculating precision is ±1dgt. against the results obtained from each measured value Current and active power integration available only on Model 3334. 7 3334 (AC/DC) 3333 (AC) ● Input Input impedance 2.4 MΩ for voltage, 10 mΩ or better (50/60 Hz) for current 2.4 MΩ for voltage, 7 mΩ or better (50/60 Hz) for current Maximum input voltage 300V, ±425Vpeak 300 Vrms, 425 Vpeak Maximum input current 30 A, ±42.5 Apeak 30 Arms, 42.5 Apeak Maximum effective peak voltage ±300% of each voltage range, Within ±425Vpeak Within 425Vpeak Maximum effective peak current ±300% of each current range, Within ±42.5Apeak ±300% of each current range, Within ±42.5Apeak Max. rated voltage to earth 300V (DC, 50/60Hz) 300V (50/60Hz) ● Display Display indication range voltage and current: 0.5% to 105% of range active power: 0% to 110.25% of range voltage and current: 1% to 152% of range active power: 0% to 231.04% of range Displacement power factor 0.000 to 1.000 (no polarity display) Display refresh rate approx. 5 times per second Response time within 0.5 s (time to rated accuracy after abrupt change in input [0 to 90% or 100 to 10% of range]) ● Functions Integration measurement Wave peak measurement Rectification method Analog output (D/A output) Waveform output Average function VT or CT ratio External Interfaces Miscellaneous No.of displayed digits: Six digits Current Integration: form 0.00000mAh, Polarity-independent integration and Sum value Active power Integration: form 0.00000mWh, Polarity-independent integration and Sum value Integration time: 1 min to 10000 h Measurement accuracy: measurement accuracy of active power ±1dgt. Maximum value of positive and negative waveform of voltage/ current (up to 300% of full scale range) Measurement accuracy: ±1.2%f.s. ("f.s." is 300% of each range) Switchable between AC+DC(True RMS), DC(simple average display) and AC(True RMS) Parameter output representation: voltage, current and active power (3 simultaneous channels) D/A select an item from current integration, active power integration, apparent power, power factor Voltage output: 1 VDC f.s. for each range Output accuracy: ±0.5% f.s. + individual measurement accuracy Parameter output representation: voltage, current and active power (3 simultaneous channels) Voltage output: 1 VDC f.s. for each range Output accuracy: ±1.0% f.s. + individual measurement accuracy AC(True RMS) Parameter output representation: voltage, current and active power (3 simultaneous channels) Voltage output: +2 VDC f.s. for each range Output accuracy: ±0.5% f.s. + individual measurement accuracy Simple averaging of specified number of samples: 1, 2, 5, 10, 25, 50 or 100 VT ratios: 1, 2, 4, 10, 20, 30, 60, 100 VT ratios: 1, 2, 4, 10, 20, 30, 60, 100 CT ratios: 1,2,3,4,5,6,8,10,12,15,16,20,24,25,30,40,50,60, CT ratios: 1,2,3,4,5,6,8,10,12,15,16,20,24,25,30,40,50,60, 75, 80,100,200,300,500,1000,2000,3000,5000, 75,80,100 10000 RS-232C interface: included as standard, Asynchronous communication method: full-duplex; Baud rate: 9600 bps (fixed) GP-IB interface: Model 3334-01 only GP-IB interface: Model 3333-01 only IEEE-488.1 1987 compliant, IEEE-488.2 1987 reference IEEE-488.1 1987 compliant, IEEE-488.2 1987 reference Display Hold (HOLD), Maximum value hold, Peak value hold, Display Hold (HOLD), Key Lock (KEYLOCK), Key Lock (KEYLOCK), Backup function (preserves settings, Settings backup (preserves settings) integration data) ● General Specifications EMC EN61010-1:2001 Pollution Factor 2, Measurement Category III (4000 V anticipated overvoltage) EN61326, EN61000-3-2, EN61000-3-3 Operating environment 0 to 40 ºC, 80% RH or less, non-condensating Safety Storage environment -10 to 50 ºC, 80% RH or less, non-condensating Rated supply voltage 100 to 240 VAC, 50/60 Hz Maximum rated power 20 VA Size and weigh 210W × 100H × 245D mm (excluding feet and projections), 160W × 100H × 227D mm (excluding feet and projections), 2.5 kg 1.9 kg 8 ■ Operate the Power HiTESTER from Your PC Data Management is as Easy as 1-2-3 ■ RS-232C (built-in with the 3334 and 3333) ■ RS-232C, GP-IB (built-in with the 3334-01 and 3333-01) Free RS-232C application for both models available from your authorized HIOKI distributor only. •Features and Functions 1. Operate the Power HiTESTER's keys on the PC as you would on the actual unit 2. Further process test data on spreadhseet software such as Excel Use of the software require a comprehensive understanding of the protocols and commands. Support for modifications to the software not available. 3334 3333 AC/DC POWER HiTESTER 3334 POWER HiTESTER (with GP-IB) 3334-01 (Accessories: Instruction Manual (1), Power cord (1)) POWER HiTESTER 3333 POWER HiTESTER (with GP-IB) 3333-01 (Accessories: Instruction Manual (1), Power cord (1)) ■ Options (Common to both Models 3334 and 3334-01) RS-232C CABLE (9-pin to 9-pin, crossed cable/1.8m(0.07ft)) 9637 RS-232C CABLE (9-pin to 25-pin, crossed cable/1.8m(0.07ft)) 9638 GP-IB CONNECTOR CABLE (2m) 9151-02 GP-IB CONNECTOR CABLE (4m) 9151-04 No. 3 Phillips screwdriver RS-232C CABLE 9637 CONNECTION CABLE 9444 HIOKI (Shanghai) Sales & Trading Co., Ltd. : HIOKI USA CORPORATION : 6 Corporate Drive, Cranbury, NJ 08512 USA TEL +1-609-409-9109 / FAX +1-609-409-9108 E-mail: [email protected] AC ADAPTER 9443-02 When purchasing the Printer 9442, make sure you also purchase the Connection cable 9444 and AC adapter 9443-02/03 so that you can connect it to the 3333/3333-01. 1904 Shanghai Times Square Office, 93 Huai Hai Zhong Road Shanghai, P.R.China POSTCODE: 200021 TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360 E-mail: [email protected] HEAD OFFICE : 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL +81-268-28-0562 / FAX +81-268-28-0568 E-mail: [email protected] No. 3 Phillips screwdriver Print method : Thermal serial dot printing Paper width : 112 mm(4.41ft) Power supply : 9443-02/03 AC adapter, or supplied nickel-metal hydride battery Dimensions and weight : 160W(6.30")× 66.5H(2.62") × 17D(0.67") mm, 580g(20.5oz.) ■ Option Printer (For the 3333 and 3333-01) PRINTER 9442 CONNECTION CABLE (for printer 9442) 9444 RECORDING PAPER 1196 AC ADAPTER (for printer 9442 operation in Europe, except Switzerland) 9443-02 AC ADAPTER (for printer 9442, for USA) 9443-03 GP-IB CONNECTOR CABLE 9151-02 DISTRIBUTED BY Beijing Office : A-2602 Freetown, 58 Dong San Huan Nan Road Beijing, P.R.China POSTCODE: 100022 TEL +86-10-5867-4080/4081 FAX +86-10-5867-4090 E-mail: [email protected] Guangzhou Office : Room 303, Profit Plaza, No.76, West Huangpu Road Guangzhou, P.R.China POSTCODE: 510623 TEL +86-20-38392673/2676 FAX +86-20-38392679 E-mail: [email protected] All information correct as of Dec. 14, 2007. All specifications are subject to change without notice. 3334E1-7ZM-07P Printed in Japan