S−AU27AL,S−AU27AM,S−AU27AH TOSHIBA RF POWER AMPLIFIER MODULE S−AU27AL,S−AU27AM,S−AU27AH 25W FM RF POWER AMPLIFIER MODULE Unit in mm l S-AU27AL : f = 400~430MHz l S-AU27AM : f = 450~490MHz l S-AU27AH : f = 490~512MHz MAXIMUM RATINGS (Tc = 25°C) CHARACTERISTIC SYMBOL RATING UNIT DC Supply Voltage VCC1 16 V DC Supply Voltage VCC2 17 V DC Supply Voltage VCC3 17 V Total current IT 10 A Input Power Pi 600 mW Output Power Po 40 W Tc (opr) −30~100 °C Tstg −40~110 °C Operating Case Temperature Range Storage Temperature Range ELECTRICAL CHARACTERISTICS (Tc = 25°C) CHARACTERISTIC Frequency Range EIAJ TOSHIBA Weight: 35g — 5−53Q TEST CONDITION MIN. TYP. MAX. UNIT frange ― 400 — 512 MHz 32 — — W 22.0 — — dB 35 — — % — 1.5 2.5 — — −30 −25 dB Po Power Gain Gp Total Efficiency ηT Harmonics — SYMBOL Output Power Input VSWR JEDEC VSWRin VCC1 = VCC2 = VCC3 = 12.5V Pi = 200mW ZG = ZL= 50Ω HRM Load Mismatch — Po = 35W (VCC1 = adjust) VCC2 = VCC3 = 15V Pi = 200mW VSWR load 20: 1 all phase Stability — VCC2 = VCC3 = 12.5V VCC1 = 3~12.5V Pi = 200mW VSWR load 3: 1 all phase No Degradation ― All spurious output than 60dB below desired signal ― 000707EAA2 · TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of such TOSHIBA products could cause loss of human life, bodily injury or damage to property. In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability Handbook” etc.. 2001-02-02 1/3 S−AU27AL,S−AU27AM,S−AU27AH CAUTION · This product has intersetting cap. Please pay attention for exceeding stress and foreign matter in your application. And not to take away the cap. · Beryllia Ceramics is used in this product. The dust or vapor can be dangerous to humans. Do not break, cut, crush or dissolve chemically. Dispose of this product properly according to law. Do not intermingle with normal industrial or domestic waste. SCHEMATIC TEST FIXTURE 000707EAA2 · The TOSHIBA products listed in this document are intended for usage in general electronics applications (computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances, etc.). These TOSHIBA products are neither intended nor warranted for usage in equipment that requires extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments, medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this document shall be made at the customer’s own risk. · The information contained herein is presented only as a guide for the applications of our products. No responsibility is assumed by TOSHIBA CORPORATION for any infringements of intellectual property or other rights of the third parties which may result from its use. No license is granted by implication or otherwise under any intellectual property or other rights of TOSHIBA CORPORATION or others. · The information contained herein is subject to change without notice. 2001-02-02 2/3 S−AU27AL,S−AU27AM,S−AU27AH CAUTION These are only typical curves and devices are not necessarily guaranteed at these curves. 2001-02-02 3/3