XPPOWER SDS150PS15B

AC-DC
150 Watts
xppower.com
SDS150 Series
•
3” x 5” Footprint
•
Fits 1U Applications
•
Convection-cooled
•
Open Frame & U-Channel Versions
•
Optional Power Fail Detect Signal
•
Optional Low Temperature Operation
•
Up to 90% Efficiency
Specification
Input
General
Input Voltage
Input Frequency
Input Current
• 90-264 VAC (120-370 VDC)
• 47-63 Hz
• 2.0 A at 115 VAC
1.0 A at 230 VAC
Inrush Current
• 20 A at 115 VAC
63 A at 230 VAC
Power Factor
• >0.95
Earth Leakage Current • <0.40 mA at 115 VAC
<0.75 mA at 230 VAC
Input Protection
• 3.15 A on board fuse
Output
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Line Regulation
Load Regulation
Transient Response
•
•
•
•
•
•
•
•
•
•
Ripple & Noise
Overvoltage Protection
Overload Protection
Short Circuit Protection
•
•
•
•
Temperature
Coefficient
•
See table
±5%
±1%
No minimum load required
2 s max
2 ms typical
>16 ms
1% max, ±0.5% typical
5% max, ±3.0% typical
4% max deviation, recovery to within 1%
in 500 µs for a 50% load change
1% pk-pk max
112-132%, recycle input to reset
110-150% with auto recovery
Trip & restart (Hiccup mode),
auto recovery
0.04%/°C
Efficiency
Isolation
Switching Frequency
Power Density
Signals
MTBF
• 88% typical, 90% max
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VDC Output to Ground
• PWM 60 kHz typical, PFC 100 kHz typical
• 6.9 W/In3 for open frame version
• Power Fail Detect = TTL low (option)
• >100 kHrs per MIL-HDBK-217F
Environmental
Operating Temperature • 0 °C to +70 °C, derate linearly from 100%
load at +50 °C to 50% load at +70 °C,
low temperature option ‘-L’ -40 °C
Cooling
• Convection-cooled
Operating Humidity
• 5-95% RH, non-condensing
Storage Temperature
• -40 °C to +85 °C
Vibration
• 2 g on 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
•
•
•
•
•
•
•
•
•
EN55022, FCC Part 15, level B conducted
EN61000-3-2
EN61000-3-3
EN61000-4-2, level 2 Perf Criteria A
EN61000-4-3, 3 V/m Perf Criteria A
EN61000-4-4, level 2 Perf Criteria A
EN61000-4-5, level 3 Perf Criteria A
EN61000-4-6, level 2 Perf Criteria A
EN61000-4-11, 70% UT for 10 ms,
40% UT for 100 ms, <5% UT for 5000 ms
Perf Criteria A, B, B
• EN60950-1, UL60950-1, CSA60950-1
per cUL, CE Mark LVD
Maximum
Output Power
144 W
150 W
150 W
150 W
150 W
150 W
150 W
150 W
Output Current
Output
Voltage
9V
12 V
15 V
18 V
24 V
30 V
36 V
48 V
Minimum
0A
0A
0A
0A
0A
0A
0A
0A
Total
Regulation(1)
5%
5%
5%
4%
3%
2%
2%
2%
Maximum
16.00 A
12.50 A
10.00 A
8.33 A
6.25 A
5.00 A
4.17 A
3.13 A
Model Number(2,4,5,6)
SDS150PS09B†^
SDS150PS12B†^
SDS150PS15B†^
SDS150PS18B†^
SDS150PS24B†^
SDS150PS30B
SDS150PS36B
SDS150PS48B†^
Notes
1. Total regulation includes initial set accuracy, line regulation and load regulation.
2. For optional 2 pin Molex input, add suffix ‘-D’ to model number. Example SDS150PS12-D.
3. For non-standard voltages contact sales office.
4. For optional Power Fail Detect signal (PFD), add suffix ‘-P’ to model number . Example: SDS150PS48B-P.
5. For optional PCB only version, delete suffix ‘B’ from model number. Example SDS150PS48.
6. For optional low temperature operation, add suffix ‘-L’ to model number. Example: SDS150PS12-L
† Available from Farnell. See pages 204-206.
^ Available from Newark. See pages 207-208.
Mechanical Details
Open Frame
1.16 (29.6)
All dimensions are in inches (mm)
Tolerance: ±0.02 (±0.5)
Weight: 1.23 lbs (560 g) approx.
M3 x P0.5 (Mounting Holes) x 4
1.57 (40.0)
0.80 (20.3)
Pin
1
2
3
4
5
6
ø4.0 (Mounting Holes) x 4
0.56 (14.2)
0.22 (5.5)
5.00 (127.0)
0.22 (5.7)
4.55 (115.6)
1.40 (35.6)
AC
Input
3.00 (76.2)
0.32 (7.9)
2.57 (65.3)
3.00 (76.2)
P2
1
DC
Output
L
P2 - PIN CONNECTIONS
Function
Pin
V1
7
V1
8
V1
9
V1
10
V1
11
V1
12
13
Function
Return
Return
Return
Return
Return
Return
PFD(2)
Pitch = 3.96 mm
N
Notes:
13
G
P1
PFD
0.43 (10.9)
0.12 (3.0)
1.21 (30.7)
1.16 (29.6)
0.80 (20.3)
U Channel
M3* P0.5 (Mounting Holes) x 5
0.54 (13.6)
1.18 (30.0)
1. Dimensions in inches (mm), tolerance ±0.02 (±0.5).
2. Optional Power Fail Detect signal on ‘P’ versions only. Standard
models have no connection for pin 13.
3. Input connector P1 mates with Molex housing 09-50-3051 and
Molex 2478 series crimp terminal.
4. Output connector P2 mates with Molex housing 09-50-3131 and
Molex 2478 series crimp terminal.
5. For mating connector kit order part number SDS120 CON KIT.
6. For cable harness order part number SDS120S LOOM.
7. DIN clips are available for alternate mounting order 2 x ‘DIN CLIP’.
8. For optional cover kit order part number SDS150 COVER.
To receive unit with cover fitted add suffix ‘-C’ to model number.
Height increases by 0.18 (4.5).
1.18 (30.0)
AC Input
G N
L
P1
ADJ
Pin 13 PFD is <0.4 V for either
AC Fail (<90 VAC) or
DC Fail (<95% Vnom).
Sink current is 10 mA max.
45.0 (114.3)
DC Output
0.67 (16.9)
Pitch = 3.96 mm
1.62 (41.2)
0.55 (14.0)
M3* P0.5 (Mounting Holes) x 4
PFD
PFD is +5 V for normal operation.
Source current is 5 mA max.
1 P2
13
2.57 (65.3)
+5 V
0.25 (6.4)
0.25 (6.4)
3.90 (99.06)
4.00 (101.6)
4.50 (114.3)
5.00 (127.0)
Power Fail Detect
Internal
3.21 (81.5)
22-Jun-07
AC-DC
SDS150
Models and Ratings