AZETTLER SG-24F

SG-24F
THREE PHASE SOLID STATE RELAY
10 THRU 25 AMPS
36 TO 440 VRMS
FEATURES
•
•
•
•
•
•
•
•
Photo isolation
LED status indicator
Up to 800V blocking voltage
Both “Zero Voltage” and phase controllable
“Random” Switching versions
High surge capability
Built-in snubber
Triac Output Circuitry
UL, CUR approval pending
INPUT
Type
D38 X Z10
D38 X Z15
Control Voltage Range
3 to 32 VDC
Turn On Voltage
3 VDC max.
Turn Off Voltage
1 VDC min.
Max. Input Current
D38 X Z25
35 mA at 32 VDC
Max. Reverse Voltage
-32 VDC
OUTPUT
Operating Voltage Range
36 to 440 Vrms
Blocking Voltage
800 Vpk
Type
D38 X Z10
D38 X Z15
Load Current Range (A)
0.1 to 10
0.1 to 15
0.1 to 25
Max. Surge Current (1/2 Cycle)
100 Apk
150 Apk
250 Apk
3 mA
5 mA
10 mA
Max. Leakage Current
Voltage On-state Drop (max.)
1.5 Vrms
Max. Turn-on Time
1/2
cycle plus 1 ms
Max. Turn-off Time
1/2
cycle plus 1 ms
Min. Off-state Dv/Dt at Maximum Rated Voltage
Min. Power Factor Allowable
D38 X Z25
200 V/us
0.5
GENERAL
Dielectric Strength
Insulation Resistance
Max. Capacitance (in/out)
Ambient Temperature
Mounting
4000 Vrms min. (at 50/60 Hz, 1 min.)
1000 megohms min. (at 500 VDC)
8 pf
Operating: -30°C (-22°F) to 80°C (176°F)
Storage: -30°C (-22°F) to 100°C (212°F)
Panel Mount
Termination
Screw
Weight
315 g
7/16/08W
SG-24F
RELAY ORDERING DATA
SG-24F
MODEL
D
38
Z
25
P
INPUT
VOLTAGE
LOAD
VOLTAGE
ZERO CROSS
FUNCTION
LOAD
CURRENT
PHASE LOSS
PROTECTION
D: 3VDC TO 32VDC
36 TO 440 VAC
Z: Zero cross turn-on
P: Non-zero cross turn-on
10: 10 Amp
15: 15 Amp
25: 25 Amp
P- With
NIL- Without
MECHANICAL DATA
Outline Dimensions
1.181
[30] Max
SG-24F/
2-M3
.827
[21]
6-M4
Wiring Diagram
L1
L2
W
L3
Outline Dimensions
1.181
[30] Max
6-M4
P
4-R.104
[R2.65]
3-M3
2.953
[75]
Wiring Diagram
L1
L2
W
+
L3
INPUT
N
V
LOAD
4.134
[[105]] Max
LOAD
U
3.614
[[91.8]]
LOAD
1.874
[47.6]
2.126
[54]
-
.827
[21]
SG-24F/
+
INPUT
3.614
[[91.8]]
4.134
[105] Max
V
LOAD
LOAD
U
LOAD
1.874
[47.6]
2.126
[54]
2.953
[75] Max
4-R.104
[R2.65]
-
Dimensions in inches with metric equivalents in parentheses. Tolerance: ± .010"
INSTALLATION
PRECAUTIONS
1.
When mounting the relays side by side, provide a space equivalent to the width of a single SSR between two adjacent SSRs.
Otherwise, reduce the load current flow to 1/2 to 1/3 of the rated
current.
1.
Before connecting a load that generates a high surge current,
such as a lamp load to the SSR, make sure that the SSR can
withstand the surge current of the load.
2.
2.
When mounting relays on heat sink surface, first apply a heat
conductive grease to the metal back surface of the SSR. Press
the SSR firmly onto the heat sink to ensure a good seal. Screw
the SSR down to the heat sink.
The product data sheet shows the non-repetitive peak value of
the surge current that flows through the SSR. Normally, use 1/2
of the non-repetitive peak surge current as the standard value. If
a surge current exceeding that value is expected, connect a
quick-blowing fuse to protect the SSR.
3.
Next, wire the screw terminals and securely tighten the screws.
7/16/08W
SG-24F
HEAT SINK SF92B-150
.118
[ ]
[3]
5.157
[
[131]
]
3.614
[[91.8]]
1.874
[[47.6]]
4.72
[[120]]
3.15
[ ]
[80]
5.59
[[142]]
4-M5
.157
[ ]
[4]
2.165
[ ]
[55]
4.72
[[120]]
5.906
[
[150]
]
HARDWARE ORDERING DATA
DESCRIPTION
ORDER NUMBER
Heat Sink
SF92B-150
CHARACTERISTICS CURVE
7/16/08W