MOTOROLA SN74LS76

SN54/74LS76A
DUAL JK FLIP-FLOP
WITH SET AND CLEAR
The SN54/ 74LS76A offers individual J, K, Clock Pulse, Direct Set and Direct Clear inputs. These dual flip-flops are designed so that when the clock
goes HIGH, the inputs are enabled and data will be accepted. The Logic Level
of the J and K inputs will perform according to the Truth Table as long as minimum set-up times are observed. Input data is transferred to the outputs on the
HIGH-to-LOW clock transitions.
DUAL JK FLIP-FLOP
WITH SET AND CLEAR
LOW POWER SCHOTTKY
J SUFFIX
CERAMIC
CASE 620-09
MODE SELECT — TRUTH TABLE
INPUTS
OUTPUTS
16
OPERATING MODE
Set
Reset (Clear)
*Undetermined
Toggle
Load “0” (Reset)
Load “1” (Set)
Hold
SD
CD
J
K
Q
Q
L
H
L
H
H
H
H
H
L
L
H
H
H
H
X
X
X
h
l
h
l
X
X
X
h
h
l
l
H
L
H
q
L
H
q
L
H
H
q
H
L
q
1
N SUFFIX
PLASTIC
CASE 648-08
16
1
*Both outputs will be HIGH while both SD and CD are LOW, but the output states are unpredictable
if SD and CD go HIGH simultaneously.
H,h = HIGH Voltage Level
L,l = LOW Voltage Level
X = Immaterial
l, h (q) = Lower case letters indicate the state of the referenced input (or output) one setup time prior
to the HIGH-to-LOW clock transition
D SUFFIX
SOIC
CASE 751B-03
16
1
ORDERING INFORMATION
SN54LSXXJ
SN74LSXXN
SN74LSXXD
Ceramic
Plastic
SOIC
LOGIC DIAGRAM
LOGIC SYMBOL
Q
2
Q
CLEAR (CD)
K
1
CP
4
J C Q
D
SET (SD)
K
J
SD
Q
16
7
15
14
SD
Q
11
6
CP
9
J C Q
D
10
12
K
3
8
VCC = PIN 5
GND = PIN 13
CLOCK (CP)
FAST AND LS TTL DATA
5-79
SN54/74LS76A
GUARANTEED OPERATING RANGES
Symbol
Parameter
Min
Typ
Max
Unit
VCC
Supply Voltage
54
74
4.5
4.75
5.0
5.0
5.5
5.25
V
TA
Operating Ambient Temperature Range
54
74
– 55
0
25
25
125
70
°C
IOH
Output Current — High
54, 74
– 0.4
mA
IOL
Output Current — Low
54
74
4.0
8.0
mA
DC CHARACTERISTICS OVER OPERATING TEMPERATURE RANGE (unless otherwise specified)
Limits
Symbol
VIH
Input HIGH Voltage
VIL
Input LOW Voltage
VIK
Input Clamp Diode Voltage
VOH
Output HIGH Voltage
VOL
Output LOW Voltage
IIH
Min
Parameter
Typ
Max
2.0
54
0.7
74
0.8
– 0.65
– 1.5
Unit
Test Conditions
V
Guaranteed Input HIGH Voltage for
All Inputs
V
Guaranteed Input LOW Voltage for
All Inputs
V
VCC = MIN, IIN = – 18 mA
54
2.5
3.5
V
74
2.7
3.5
V
VCC = MIN, IOH = MAX, VIN = VIH
or VIL per Truth Table
VCC = VCC MIN,
VIN = VIL or VIH
per Truth Table
54, 74
0.25
0.4
V
IOL = 4.0 mA
74
0.35
0.5
V
IOL = 8.0 mA
J, K
Clear
Clock
20
60
80
µA
VCC = MAX, VIN = 2.7 V
J, K
Clear
Clock
0.1
0.3
0.4
mA
VCC = MAX, VIN = 7.0 V
– 0.4
– 0.8
mA
VCC = MAX, VIN = 0.4 V
–100
mA
VCC = MAX
6.0
mA
VCC = MAX
Max
Unit
Input HIGH Current
IIL
Input LOW Current
IOS
Short Circuit Current (Note 1)
ICC
Power Supply Current
J, K
Clear, Clock
– 20
Note 1: Not more than one output should be shorted at a time, nor for more than 1 second.
AC CHARACTERISTICS (TA = 25°C, VCC = 5.0 V)
Limits
Symbol
Parameter
fMAX
Maximum Clock Frequency
tPLH
tPHL
Clock, Clear, Set to Output
Min
Typ
30
45
Test Conditions
MHz
15
20
ns
15
20
ns
Max
Unit
VCC = 5.0 V
CL = 15 pF
AC SETUP REQUIREMENTS (TA = 25°C)
Limits
Symbol
Parameter
Min
Typ
tW
Clock Pulse Width High
20
ns
tW
Clear Set Pulse Width
25
ns
ts
Setup Time
20
ns
th
Hold Time
0
ns
FAST AND LS TTL DATA
5-80
Test Conditions
VCC = 5.0 V