spu60 6 0 W D e s k t o p S witching Power Supplies series Universal 85-265VAC Input IEC-320-C14 Input Receptacle Single Outputs from 3.3 to 48VDC 3000V Isolation Splash Proof Case 4.6” x 1.36” x 2.0” Model Number Output Watts Output Volts Output Amps Total Regulation SPU60-101 SPU60-102 SPU60-103 SPU60-104 SPU60-105 SPU60-106 SPU60-107 SPU60-108 SPU60-109 SPU60-110 SPU60-111 20 30 35 40 50 55 60 60 60 60 60 3.3V 5V 6V 10V 12V 15V 18V 24V 30V 36V 48V 6A 6A 5.8A 4A 4.16A 3.66A 3.33A 2.5A 2A 1.66A 1.25A 7% 5% 5% 5% 5% 5% 5% 5% 5% 3% 3% WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 ASTRODYNE EUROPE: 353 51 561060 spu60 6 0 W D e s k t o p S witching Power Supplies PHYSICAL SPECIFICATIONS INPUT SPECIFICATIONS Input Voltage Range Frequency Range Input Current Inrush Current, typ (Cold Start) Leakage Current 90-264 VAC 47-63 Hz Low Line (115VAC) High Line (230VAC) Low Line (115VAC) High Line (230VAC) 0.75mA MAX. @ 240 VAC, FL 1.6A 1.0A 15A max. 30A max. OUTPUT SPECIFICATIONS Voltage and Current Output Power Range Load Regulation (230Vin) Line Regulation Transient Response Temperature Coefficient Ripple/Noise Over Voltage Protection Over Current Protection Start Up / Hold Up Time series See Selection Charts 0 to FL Rating +/- 7%, max. +/- 1%, max. 100Vin, FL to 1/2L 4mS +/-0.04%/°C, typ FL, 90Vin 2% Pk-Pk, max. 112-132% * 110-150% * 100Vin, FL 2S max. / 16mS min. Size Construction Weight 4.64” x 1.36” x 2.0” Desktop Style 12oz (340g) ENVIRONMENTAL SPECIFICATIONS Oper. Temperature Storage Temperature Relative Humidity EMC MTBF 0 to +40°C (FL) * 50% Load @ 70°C (See Derate Curve) -40 to +85°C * 5% to 95%, non-cond * 110Vin: FCC Part 15 Class B 220Vin: CISPR-22 Class B 100,000 Hrs DERATE CURVE GENERAL SPECIFICATIONS Input-Out Isolation Input-Ground Isolation Isolation Resistance Efficiency (FL, 230Vin) Safety 3000 VAC 1500VAC 50 Mohm min. 75%, typ (c)UL60950-1, EN60950-1 NOTE: Low cost 3 Wire IEC320/C13 (Part Number ACCRD-C13) Input Power Cords are available for these products. Inquire to the Astrodyne Sales Depart. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted * These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. WWW.ASTRODYNE.COM Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 ASTRODYNE EUROPE: 353 51 561060 spu60 6 0 W D e s k t o p S witching Power Supplies series MECHANICAL DIMENSIONS Coaxial Plug: 5.5mm outer diameter 2.1mm inner diameter, female 11mm length, center “+” 118.0±1.0 -Vout +Vout 4-R 34.5±1.0 4.0 52.0±1.0 SWITCHING POWER 0.5 Output Cord Length 72” typ. AC INPUT IEC 320 INLET WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 ASTRODYNE EUROPE: 353 51 561060