VECTRON TFS140D

tfs 140 D.doc
Version 3.4
VI TELEFILTER
1. Measurement condition
Ambient temperature TA:
Input power level:
Terminating impedances in fc:
Filter Specification
06.01.02
TFS 140 D - 1/3
Package, pin connection and 50 Ω matching network
23 °C
0
dBm.
for input: :
88,6 Ω  -36,16 pF
for output:
50 Ω  0 pF,
(see page 2.)
2. Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 140 D is the minimum of the pass band attenuation amin. The minimum of the pass
band attenuation amin is defined as the insertion loss ae. The reference frequency fc is the arithmetic mean value of the upper and lower
frequencies at the 3 dB filter attenuation level relative to the insertion loss ae.
Data
typ. value
Insertion loss (Reference level) ae
Centre frequency
fc at ambient temperature ( fCAT )
Pass band (-3 dB)
Bandwidth at ambient temperature:
0,7 dB - band width
1 dB - band width
3 dB - band width
20 dB - band width
40 dB - band width
45 dB - band width
Amplitude ripple (p-p):
fc ... fc ± 3,25 MHz
Relative attenuation
arel
fc
fc ± 3,25 MHz
fc ± 3,25
MHz
fc ± 3,5
MHz
fc ± 4,6
MHz
fc ± 10
MHz
fc ± 10
MHz
fc ± 34
MHz
fc - 139
MHz
fc - 89
MHz
fc - 89
MHz
fc - 65
MHz
fc - 65
MHz
fc - 50
MHz
fc - 50
MHz
fc - 34
MHz
fc + 34
MHz
fc + 55
MHz
fc + 55
MHz
fc + 60
MHz
fc + 60
MHz
fc + 260
MHz
Average group delay in pass band:
Group delay ripple in pass band (p-p):
Deviation from linear phase (p-p)
fc ... fc ± 3,25 (±3,5) MHz
Crosstalk attenuation compared to main signal
Triple transit attenuation compared to main signal
Temperature coefficient of frequency ( Tcf )
Frequency deviation of fc over temperature
Operating temperature range
Storage temperature range
Input power level
-
Generated:
Checked/Approved:
22,5
140
dB
MHz
6,80
6,97
7,37
8,30
8,65
8,72
MHz
MHz
MHz
MHz
MHz
MHz
tolerance / limit
max. 25
dB
140 ± 0,1
MHz
fC- 3,5 MHz ... fC + 3,5 MHz
0,5
dB
max 0,7
dB
48
55
25
35
25
35
55
45
50...70
2,12
120
dB
dB
dB
dB
dB
dB
dB
dB
dB
µs
ns
max. 0,7
max. 3
min 40
min 45
min 22
min 33
min 22
min 33
min 45
min 40
min 45
max. 2,5
max. 160
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
µs
ns
4° ( 5,8°)
65
dB
44
dB
-18
ppm/K
∆fc(Hz) = Tcf(ppm/K) x (T - TA) x fCAT (MHz)
- 40 °C ... + 85 °C
- 55 °C ... + 85 °C
max. + 10
dBm
Wadim P. Dunzow
Dr. Bert Wall
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
tfs 140 D.doc
Version 3.4
VI TELEFILTER
Filter Specification
06.01.02
TFS 140 D - 2/3
3. Package
Pin 14
Pin 1
Pin 8
Pin 7
Pin 2,9
TFD140
125D
TFS
H9
tfttft L6
Input
Input RF Return
Output
Output RF Return
Package Ground
4. 50 Ω matching network:
14
9
8
L1
C1
1 2
7
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
tfs 140 D.doc
Version 3.4
VI TELEFILTER
Filter Specification
06.01.02
TFS 140 D - 3/3
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information